Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #57638427

Tender For Provisioning Of Indoor Badminton Court With Associated Infrastructure At Officers Mess, Caw Under Ge (Af) Hakimpet

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
42.60 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
8 days left
EMD
85200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provisioning Of Indoor Badminton Court With Associated Infrastructure At Officers Mess, Caw Under Ge (Af) Hakimpet

BOQ

Name of Work:- PROVISIONING OF INDOOR BADMINTON COURT WITH ASSOCIATED INFRASTRUCTURE AT OFFICERS MESS, CAW UNDER GE (AF) HAKIMPET
Sl. No. Item Description
1NOTES :- In case description of any two or more items of the schedule ‘A’ is same and the tenderer quotes different rates for such items, only lowest rate of such items will be considered for acceptance and subsequently payment will be made upon execution of the items accordingly.
2Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out Soft/loose soil complete all as specified and as directed.
3Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5 m deep; in hard/dense ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sq.m on plan and n. exceeding 1.5m in depth and getting out hard/dense soil complete all as specified and as directed.
4Excavation in trenches n. exc. 1.5m wide and exc 1.5 m, n exc. 3.00 m deep; in hard/dense ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sq.m on plan and exceeding 1.5m in depth and getting out hard/dense soil complete all as specified and as directed.
5M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
6Spreading and levelling earth in layers n exc. 25 cm thick well ramming including watering as required complete all as specified and as directed.
7Returning and filling in including spreading levelling watering and well ramming in layer n.exc 25 cm as in hard / dence soil complete all as specified and as directed.
8Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
9M&L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
10M&L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
11M&L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
12M&L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed.
13M&L Plain Cement Concrete in foundations 1:4:8 type D2 using 40 mm graded aggregate in foundation filling and mass cconcrete all as directed.
14M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finshed flat surfaces complete all as specified and as directed.
15M&L Formwork to sides of pillars, posts, struts, piers, columns of square,rectangular fair finished surfaces and stanchions complete all as specified and as directed.
16M&L Mild steel TMT CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
17All as per item 15 above but 5mm dia TMT CRS and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
18Reinforced cement concrete M 25 (20 mm graded aggregate) (design mix)in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
19Reinforced cement concrete M 25 (20 mm graded aggregate) (design mix)in Columns, pillars, piers, posts and struts complete all as specified and as directed.
20M&L Damp proof course to horizontal or verticalsurfaces including necessary formwork in cement concrete1:2:4, type B-0 40 mm thick Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified and as directed.
21Reinforced cement concrete (design mix) M-25 in Chajjas complete all as specified and as directed.
22Reinforced cement concrete (design mix) M-25 in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
23M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels,chajja cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc flat fair finished surfaces complete all as specified and as directed.
24M & L for Pre-cast cement concrete block masonry with solid blocks, Type C1 1:3:6 (20mm graded aggregate) exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and as directed.
25M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 , finished even and smooth without using extra cement complete all as specified and as directed.
26M&L for 15 mm thick plastering on fair faces of brick work or concrete surfaces in two layer with 10 mm thick in CM 1:6 and top 5 mm thick in CM 1:4, mixing water proofing compound at 3% by weight of cement (but excluding the cost of WPC) finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
27Supply only integral water proofing compound as per manufactures instruction complete all as specified and as directed.
28M&L for preparing new plastered surface of wall and applying 2mm thick putty finish to obtain smooth finish wall surface and applying two coat of distemper over a coat of alkali resistant primer complete all as specified and as directed.
29M&L for preparing new plastered surface of wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by the Engineer-in-charge and as per manufacturers instructions complete all as specified and as directed.
30Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc e 410-W (Gde E- 250) quality A complete all as specified and as directed.
31Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment e 410-W (Gde E- 250) quality A complete all as specified and as directed.
32Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 complete all as specified and as directed.
33M&L Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30 cm long of dia of neck 25 mm complete all as specified and as directed.
34S&F Toughned glass of thickness 12 mm as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required including cleats frame brackets complete all as specified and as directed.
35S&F Stainless steel double cylindar floor spring for toughned glass door with weight upto 120 Kg complete all as specified and as directed.
36S&F Premium stainless steel glass to 10-12 mm thick toughned glass door lock central lock with3 keys complete all as specified and as directed.
37S&F plantex handle for glass door /stainless steel main door pull and push handle 12 inch for toughen glass complete all as specified and as directed.
38M & L for Plain Cement concrete type C-1 1:3:6 using 20mm graded crushed stone aggregates 75mm thick as in plinth protection, hard standing, sub base, floor finish complete all as specified and directed.
39M&L hardcore of broken stones or boulders of guage n exc. 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
40M&L for 75 mm thick PCC 1:3:6 type C-2 (40 mm graded aggregate) as in sub base all as specified and directed
41M&L Cement concrete type B-1,1:2:4 (20mm graded aggregate) 75 mm thick Finishing cement concrete with out using extra cement surface even and smooth surfaces complete all as specified and as directed.
42M&L Hard wood first class 20- 25 mm thick as in boarding in floors and skirting Planed one side & edges tongued and grooved or rebated complete all as specified and as directed.
43M&L 2nd class hard wood Clean sawn battens for wooden boarding at 25 cm center/center of sectional area exc 15 Sqcm but bot exc 25 sq cm complete all as specified and as directed.
44M&L Preparing surfaces of wood and wood based materials, new surfcaes of any description and girth, not otherwise described and treated with Creosote complete all as specified and as directed.
45M&L Shock absorber pads (Elastomeric /rubber) of dimensions 50 mmx50 mm to 100mmx100 mm shock pad / absorbing rubber material Indoor badminton court surface for with necessary fixing material wooden flooring finishes complete all as specified and as directed.
46M&l Polysterene insulation memberane(XPS) placed below wooden flooring to prevent moisture protection complete all as specified and as directed.
47Bees-wax polishing on WOODEN surfaces of any description, width or girth including cleaning and preparing the surface complete all as specified and as directed.
48M&L, 9 to 10mm thick light coloured vitrified tiles in skirting set and jointed in neat cement slurry and pointed in coloured cement to match shade of tile over and including 10mm thick backing coat in CM 1:3 complete all as specified and as directed.
49S&F Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.
50S & F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
51M&L Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete
52S&F in stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stain less steel wire staples
53S&F frosted Sheet glass, ordinary quality 4.8 mm thick and glazing with rubber to UPVC frame in square/rectangle n exc 0.5 sq. m in each pane all as specified and as directed
54S&F 110 mm bore PVC (SWR) bends any radiuis all as specified and as directed
55S&F PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed to walls bore of the pipe 110 mm with clamps and etc as dircetd bt Engr In Charge.
56S&F Compact UPVC square rain water gutter of 140 mm fixed with clamps all as direcetd by Engr In Charge
57S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instruction and as directed.
58S&F Pre-painted galvalume aluminum zinc coating GI based Plain corrugated/steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified
59S&F Fibre glass reinforced translucent Plain sheeting 2 mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc.
60Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ 100 mm thickness
61M& L for point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including non- metallic rigid PVC conduit medium grade and conduit accessories ISI marked concealed in wall / ceiling/ fixed to roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor, fabricated steel sunken Modular terminal box duly painted made out of 1.60mm thick MS sheet concealed in walls, with modular cover plate for housing modular switches, socket outlets, fan regulators etc, all as specified and as directed for One LED tube light/LED Lamp/Bldg security light controlled by one way switch
62All as per Ser item No 60 above but for One Ceiling /Exhaust Fan Point controlled by one one way switch.
63All as per Ser item No 60 above but for 5 amps socket point on Same board with other switches.
64All as per Ser item No 60 above but for 5 amps socket point on independent board.
65All as per Ser item No 60 above but with 2.5 sqmm cable for 15 amps socket outlet on independent board with 2.5 Sqmm earth continuty wire complete all as specified and directed.
66All as per Ser item No 60 above but with 4 sqmm cable for 20/25 amps Power Unit on independent board with 4 Sqmm earth continuty wire complete all as specified and directed.
67Supply and fix Switch modular type, 6 Amps 240 volts single pole one way.
68Supply and fix socket outlet, 5 pin 6 Amps, Modular type.
69Supply and fix socket outlet 6/16 Amps, 6 in 1, Modular type.
70Supply and fix switch modular type,15/16 Amps 240 volts single pole one way.
71Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body.
72Supply and fix in repair surface mounting LED 2ft x2ft luminaire of capacity 36W with white powder coated CRCA housing with LEDs and full window acrylic diffuser etc.complete with all acessories internally prewired suitable for sigle phase 230volts 50Hz AC supply including connecting up with flexible copper conductor cable of size 0.5 Sqmm (nominal area) complete all as specified.
73Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 63 Amp capacity in the DB complete with connection testing and commissioning as specified and directed.
74M&L for MCB single pole, 240 volts, 6 - 32 Amps, 10 KA C Curve
75M&L for sub main wiring comprising single core , 2 Runs of 6 sqmm nominal cross sectional area,FRLS multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC casing capping/conduit and its fittings complete surface/concealed including provision of 1X6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire including taking out old submain wiring complete all as specified. Note: Two runs of 6.0 Sqmm copper cable, 1 run of copper earth wire and one run of PVC conduit shall be measured as one unit length.
76All as per item No. 74 but two run of single core 4 sqmm and one run of single core 4sqmm as earth wire complete all as specified and directed. Note: Two runs of 4.0 Sqmm copper cable, 1 run of copper earth wire and one run of PVC conduit shall be measured as one unit length.
77Supply and fix TP&N DBs, double door, 415 volt, 4 way complete all as specified and directed.
78Supply & fix exhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed.
79M&L for earthing with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to GI strip 25 x 4 as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe \\"light grade\\" for protection of earth lead and connected to test point or as directed including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and RCC Cover of size 450X450X50mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Soil upto a distance of 50.00 mtr and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and Testing on completion , including taking down unserviceable earthing complete all as specified and as directed Engr-in-charge.
80M&L for cable in trenches/passing through pipe/on wall , XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 4 core.
81Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in Soft / Loose Soil, complete all as specified and as directed.
82Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
83Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
84M&L Sand Cushioning (dry) in Trenches for protec-tion of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).
85S&F Sub-Class B brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
86Supply and fix wall mounted busbar chamber of capacity 200 Amps, 4 way made out of high quality materials and is rated for 200 amps 415 volts including busbar of make Havells or equivallent in selvo/powerline complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57638427
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.60 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provisioning Of Indoor Badminton Court With Associated Infrastructure At Officers Mess, Caw Under Ge (Af) Hakimpet
Basic Detail
Tender No 8971/E8
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 22 Sep 2026
Submission Date 30 Sep 2026
Open Date 02 Oct 2026
Finance
Tender Value 42.60 Lakhs
Tender Fee 500
EMD 85200
Exemption Available
Document List
8971psrevs.pdf
BOQ_886210.xls
c64c1a05-7ce5-4c36-9aa4-c4c0c3d59d02.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

8971psrevs.pdf

xls

BOQ_886210.xls

html

c64c1a05-7ce5-4c36-9aa4-c4c0c3d59d02.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders