Tender For Lac-Ads-2024-25- Kallyasseri Lac - Sri.M Vijin Mla -Installation Of Lights At Cherukunnu Town-Sitc Of Decorative Led Lights-General Electrical Work
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Sep 2026
6 days left
EMD
42267
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kannur → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Lac-Ads-2024-25- Kallyasseri Lac - Sri.M Vijin Mla -Installation Of Lights At Cherukunnu Town-Sitc Of Decorative Led Lights-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Footpath Lighting |
| 2 | OD249497/2025-2026:Supply installation testing commissioning of Decorative Pole 3.2/3 meter height above theground level made out of GI, tubular pole having two section section, bottom section ofminimum 900/1000mm with base dia of 114mm and upper section of minimum 2300/2000mmwith dia of 76mm. The pole shaft shall be as per IS 1161. The pole shall have base plate ofdimension 200x200x12mm including minimum16mm diameter 4 numbers foundation bolts of450mm bolt length, 200mm pitch circle diameter manufactured from special steel along withnuts, washers, The pole shall be with inbuilt control gear tray at bottom section. The controlgear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 wayterminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector and provisionfor earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Designcomply EN40 standard and basic wind speed 169kmph. Pole should hot dip galvanized to 65microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coatsof epoxy primer and above that it should be given marine coating. The complete system shouldbe hot dipped Galvanised. (K lite COLOMBIA/Kesslec RILA/CHATSWORTH). |
| 3 | OD146917/2026-2027:SITC of LED Decorative Classic luminaire of system wattage 50W, with minimum dimension315mm width and 545mm height, BIS certified with a bodyand frame of high pressure die cast aluminium, a frosted PMMA protector (IK06) fixed on tothe optical unit, separate optical and control gear compartment accessed by opening fourscrews at the top of the luminaire, a vent pressure equalization unit and pre-cabled asrequired. The luminaire shall have ingress protection of IP65. Highly efficient temperatureresistant lenses for light distribution with several optical options providing excellentphotometry to optimally cater to different applications. Overall system efficiency of120lm/W at correlated colour temperature (CCT) 3000K, colour rendering index (CRI) >70and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor > 0.95, with BIS certified potted driver having internal surge protection of 4 kV .(KESSLEC RILA 50W WW/ Klite DYNASTY MIDI 50W WW) |
| 4 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 5 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 6 | OD249498/2025-2026:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 8 | 90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 9 | 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 10 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 11 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 12 | OD249492/2025-2026:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 32/40 mm or nearest size |
| 13 | OD249501/2025-2026:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 32/40 mm or nearest size |
| 14 | 90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class) |
| 15 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 16 | 90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) |
| 17 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 18 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 19 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 20 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 21 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 22 | OD249496/2025-2026:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required- |
| 23 | OD249502/2025-2026:Supply and fixing Digital Time switch 240V AC DIN/BASE mounting in the existing enclosureand giving connection as required- (L&T110-240 V Digital Time Switch 67DDTO) |
| 24 | OD249499/2025-2026:Supply and fixing 32A HRC fuse base with HRC fuse link- |
| 25 | OD249494/2025-2026:Supply and fixing of Neutral link 32 A, 2 Way neutral links mounted on DMC/SMC base- |
| 26 | 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 27 | 90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 28 | 5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 29 | OD249493/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25x6 mm brass nut and bolt |
| 30 | OD249504/2025-2026:Supply and fixing 32mm dia 6Kgff/cm2 PVC Pipe including fixing the pipe withclamp/clips atetc. as required (for service pipe) |
| 31 | OD249495/2025-2026:Hire and Labour charges for Conreate core cutting |
| 32 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 33 | OD343627/2025-2026:Fabrication, supply, conveyance and installation of Granite name board with table rubbed,edges rounded and polished, of size 75x50 cm or nearest size deep and 1.8 cm thick , withinscription there on indicating name of project the cost involved, the dates of commencement,completion, inauguration etc , fixing it on suitable place including fixing charge etc as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
TodaySep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender