Tender For Special Repair To Bldg No P-7 Of 4 Inf Div Hq At Old Cantt, Prayagraj.
Tender Value
38.08 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
22 days left
EMD
76200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Bldg No P-7 Of 4 Inf Div Hq At Old Cantt, Prayagraj.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of 6 mm thick AC corrugated sheets in roof covering including ridges, hips, valleys and flashings etc complete all as specified and directed. |
| 2 | S & F Mild steel joist channel or angle or tee section, MS tube and fixed with ms flat iron cut into shape drilled and fixed with screw conforming to Fe-410-W (Gde-E-250) quality-A incl applying two coats of synthetic enamel paint over a coat of primer (Red oxide Zinc chrome) incl preparation of surfaces on new steel surface exc 10 cm width or girth complete. |
| 3 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long of dia 11 to 15mm complete all as directed |
| 4 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as directed |
| 5 | S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long & dia 20mm complete all as specified and directed |
| 6 | S&F pre-painted galvanized aluminium zinc coating GI based corrugated steel sheeting 0.50 thick (TCT) of any colour having tensile strength 550Mpa with resin coating on both side surfaces @ 150 gm/Sqm of coating (Total both side) as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed |
| 7 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 8 | Excavation in trenches in soft/loose soil n.exc 1.5 m wide and n.exc 1.5m deep and getting out i all as specified . |
| 9 | Returning , filling in of excavated soil, including spreading , levelling , watering and well ramming in layers not exc 25 cm thick complete all as specified. |
| 10 | Removing excavated material (Soils) to a distance exc 250m but n exc 500m and depositing at a level n exc 1.5m above the starting point complete all as specified and diercted. |
| 11 | M&L cement concrete Type-D2, 1:4:8 (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc incl necessary formwork complete all as specified and directed |
| 12 | M/L hard core of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed |
| 13 | M&L 100mm thick cement concrete (using 40mm graded stone aggregate) type D-2 (1:4:8) as in sub base complete all as specified and directed |
| 14 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) incl chequered tiling and Paver blocks |
| 15 | Demolition of brick work built in cement mortar complete all as specified and directed |
| 16 | M&L brick work with subclass 'B' brickwork straight or curved on plan exc 6 m mean radius built in CM 1: 6 complete all as specified. |
| 17 | M&L brick work with sub class B brick straight or curved on plan exc 6 m mean radius built in CM 1: 6 complete all as specified.(Except brick) Note : Old bricks obtained from demolition shall be reused after cleaning all as directed by Eng-in-Charge |
| 18 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises complete all as specified and directed |
| 19 | M&L Vitrified tiles Dark shade/marbonite double charged/Parcelano GBT 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified. |
| 20 | M&L Vitrified tiles Dark shade/marbonite double charged/Parcelano GBT 8-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 sqm, in skirting/dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 10 mm thick screed bed in cement mortar 1:3 complete all as specified. |
| 21 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar |
| 22 | M&L for 14-18 mm thick Granite slab work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including rounding to edges/half rounded edge and hole for gas pipe in pre-cast slab as well as stone slab in cooking platform complete all as specified and directed by Engr-in-charge |
| 23 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc. |
| 24 | M&L for rendering 15 mm thick on fair faces of brick work in CM in 1:4 finished even and fair and mixing with water proofing liquid as per manufacturer instruction (but excluding the cost of water proofing liquid ) external surface complete all as specified and directed |
| 25 | Supply only Liquid water proofing compound of approved make complete all as specified and directed |
| 26 | M&L for rendering 10mm thick in CM (1:6) on Brick/ Concrete surface finished even and fair on internal surfaces of wall complete all as specified and directed. |
| 27 | M&L for 75 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection or as in tank base finishing cement concrete surface finished even and fair complete all as directed |
| 28 | M/L 50mm thick PCC(1:2:4) type B1 ( using 20mm graded stone aggregate) finishing surface even and fair complete all as directed |
| 29 | Dismantling of ceiling boards /wall panelling of any type and any thickness including cover fillets and timber frame work complete. |
| 30 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre reinforced gypsum) Size 595 x 595 mm of approved texture, 12mm thick fully perforated micro tegular design and patterns having moisture micro tegular edged or 1 0 mm content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 31 | Providing and fixing 6mm thick High Pressure interior/exterior compact Laminate of Greenlam, Century, Marino or equivalent made out of thermosetting resign treated Kraft as core material and design paper as a finish surface. Compact laminates should have the characteristic of flame retardant fulfilled the criteria of under BS-476/97 and EN438-6 with classification of BS1D0 standard property, Anti bacterial and anti-termite property under JIS Z2801:2000, Chemical resistance, Scratch resistant fire resistance, weather & climatic shock resistance(The manufacturer should provide 10 years warranty certification on any manufacturing and moisture related defects.) The compact laminates should be resistance to water immersion through permissible increase on thickness and mass <0.60% and board should have density >1.35kg/cm3 and fulfilled the criteria of FSCand Green Guard Gold certification and manufactured under EN438-2&3:2005 standard Finish and colour of compact laminates should be finalised under direction of Engineer-in-charge. Compact laminates should be installed on 25x50mm aluminium tube or approved tube size at 600mm c/c under desirable height and fixed through same compact colour rivets or compact adhesive as per recommended by compact supplied agency. Finish and colour of interior clade shall be as approved by Engineer-in-charge complete all as specified and directed |
| 32 | S&F 15mm thick toughned glass as in hinged door , partition, automatic doors and simillar works including SS clamps, SS handles of size 300mm - 450mm, locking system, floor door spring, cuttig to shape, drilling holes as requiredand all fittings required to make door functional complete all as specified and as directed by Engr-in-charge |
| 33 | M&L for Complete removal of existing treatment on exterior surface of wall/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vacuum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour, complete all as specified and directed. |
| 34 | Material and labour for two coats of water based premium acrylic smooth exterior emulsion of approved coulur with silicon addictive & color stay technology excellent dirt pick up resistance with low VOC less than 50 gram/ltr as per the LEEDS specification anti algal propertiess in two coats @ 1.79 ltrs (undiluted)/10sq mtrs diluted with water as per manufacturer instruction, complete all as specified and directed. Mame of Manufacturer : ASIAN/BERGER/NEROLAC or equivalent make as mentioned in Appx D to PSNote- The contractor shall obtain approval of the agency from GE and shall enter a memorandum of understanding (MOU) with the manufacturer duly approved by GE. The execution of work shall be commenced after the submission of MOU and necessary approval from the Engineer-in-charge. MOU shall be valid during currency of work. However during defect liability period, if any defect is noticed, the contractor shall only be responsible for the rectification of same. |
| 35 | Material and labour for 1mm thick wall care putty with one coat of acrylic water based exterior grade primer @0.9 ltrs (undiluted)/10sq mtrs diluted with water 1:1 ratio. Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed. Manufacturer : ASIAN/BERGER/NEROLAC or equivalent make as mentioned in Appx D |
| 36 | M&L for complete removal of existing old treated surfaces of wall ceiling by scrapping with wire brush/sanding paper/metal patty/paint scrapping machine, removing nails etc and make surface clean free from dustloose paints etc filling depressions with wall care putty to receive decorative coat/ painting coat complete all as specified and directed. |
| 37 | M&L for preparation of new/old plastered surface and applying two coats of oil bound distemper on walls/ceiling complete all as specified and directed. |
| 38 | M&L for applying 1mm thich birla wall care putty over a coat of primer on wall/ceiling surfaces complete all as directed by Engr-in-charge |
| 39 | Dismantling boarding any desccription fixed in any position with nails or any other means complete all as specified and directed |
| 40 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for. |
| 41 | Demolition of reinforced cement Concrete Concrete of any description and in any position not otherwise specifically provided for complete all as directed |
| 42 | M&L RCC M-25 (Design Mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 43 | M&L RCC M-25 (Design Mix) as in Columns, pillars, piers, posts and struts |
| 44 | Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter as flat rough finished surfaces as directed |
| 45 | Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions as square or rectengular rough finished surfaces as directed |
| 46 | M&L for mild steel TMT bars 10 mm dia and over in reinforcement cut to length bent to shape required incl cranking bending, spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia all as specified and as directed. |
| 47 | M&L for mild steel TMT bars 5-10 mm dia as in stirrups reinforcement cut to length bent to shape required incl cranking bending, spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia all as specified and as directed. |
| 48 | Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, socket, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfaces of walls, floors, etc. all as specified and as directed. |
| 49 | M&L for point wiring one light/fan point with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 1.5 sqmm as phase & neutral drawn in and including PVC conduit medium grade not less than 20 mm dia, ISI marked, duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated FRLS unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly for one light/fan point in electrogalvanised modular steel terminal switch box for mounting modular switch etc. incl making good to surface with CM(1:4) plaster and paint to match the surface complete all as specified and directed.Note :- Modular flush box, Cover plate, switches/ socket/ regulators etc. shall be measured and paid separetly under respective item of this BOQ. |
| 50 | Ditto All as per item No 49 above but for One 5 pin 5 amps socket outlet on same board |
| 51 | Ditto All as per item No 49 above but for One 6 pin 5/6 amps socket outlet on independent board |
| 52 | Ditto All as per item No 49 above but for One 6 pin 5/6 amps socket outlet on independent board with cable of size 1.5sqmm for phase, neutral and earth |
| 53 | Ditto All as per item No 49 above but for One 6 pin 15/16 amps socket outlet on independent board with cable of size 4sqmm for phase, neutral and earth |
| 54 | S&F modular Switch Piano Flush button single pole one way 5/6 Amps 230V AC complete all as specified and directed. |
| 55 | S&F modular socket outlet flush type 3/5 pin 5/6 Amps 230V AC complete all as specified and directed. |
| 56 | S&F modular switch piano flush single pole one way 15/16 Amps 230V AC complete all as specified and directed. |
| 57 | S & F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 58 | S&F modular ceiling fan 5 step regulator 2 module complete all as specified and directed |
| 59 | S&F electrogalvanised steel modular flush box 1/2 module complete all as specified and directed |
| 60 | S&F electrogalvanised steel modular flush box 3 module complete all as specified and directed |
| 61 | S&F electrogalvanised steel modular flush box 6 module complete all as specified and directed |
| 62 | S&F electrogalvanised steel modular flush box 8 module complete all as specified and directed |
| 63 | S&F modular white cover plate 1 module complete all as specified and directed |
| 64 | S&F modular white cover plate 3 module complete all as specified and directed |
| 65 | S&F modular white cover plate 6 module complete all as specified and directed |
| 66 | S&F modular white cover plate 8 module complete all as specified and directed |
| 67 | S&F Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and directed. (For AC and Geysers) |
| 68 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed |
| 69 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 9/10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 70 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 71 | S&F MCB DB TPN 4 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed. |
| 72 | S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed. |
| 73 | Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 74 | Supply & fixing MCB, SPN, AC, 240 volts of 32 Amps capacity 10KA, 'B' series complete all as specified & directed. |
| 75 | Supply and fix MCB TPN 40 to 100 Amp ,10 KA , \\" C\\" curve 415V as directed by engr- in- charge. |
| 76 | S&F ceiling light with recessed mounted LED light luminaries of size 600 mm x 600 mm CDL/WW an independent isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage- 36 watt maximum, Colour Temp - 3000 to 6500 K, Lumen output- 4200-4400 Lm, THD < 10%, PF > 0.95, having short circuit and surge protection upto 4 KVA with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. |
| 77 | Disconnecting and taking out old unserviceable submain wiring and S&F sub main wiring with two single core PVC insulated FRLS-H,unsheathed, multistranded copper conductor cable 6 Sqmm with one single core 6 Sqmm PVC insulated FRLS-H, unsheathed, stranded copper conductor cable as earth wire in and including PVC conduit(HMS), duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling and earth wire connected to common earth point complete all as specified & directed.Note:- Two run of 6 sqmm copper wire as phase and neutral and one run of 6 sqmm copper cable green in color as earth wire and one run of PVC rigid conduit will be measured as one unit |
| 78 | M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below NGL and top edge of the plate not less than 1.5 Mtr deep below NGL, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in , removal of surplus soil to a distance in n.exc. 50 mtr incl GI wire 4mm dia nut bolts etc to earth plate one end connected to continuous earth wire incl GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed. |
| 79 | Disconnecting and taking out old unserviceable XLPE cable of any size supply and laying XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables as service cable(heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 50 sqmm 3.5 core incl earth work, sand cushioning, brick or PCC covering, light grade GI tubing where necessary and testing complete all as specified and directed |
| 80 | M&L Sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed.NOTE : Punned thickness only shall be measured. |
| 81 | Supply and laying dry well burnt locally available brick sub class'B' modular bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as spcified and directed . |
| 82 | S&F 50 mm dia Galvanised steel tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road/ floor etc for cable protection, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
TodayOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender