Housing Urban and Rular Development Government Departments Closing in 20 days TDR #57637708

Tender For Construction Of Residential Accomodation Of District Development Council /Pris At Samba District Samba (Under Ut Capex Budget).

Issued by Government Departments · Kathua, Jammu and Kashmir
Tender Value
7.89 Crore
Estimated cost
Bid Submission
12 Oct 2026
20 days left
EMD
15.79 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kathua → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Residential Accomodation Of District Development Council /Pris At Samba District Samba (Under Ut Capex Budget).

BOQ

Name of Work:- Construction of Residential Accomodation of District Development Council /PRIs at Samba District Samba (under UT Capex Budget).
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil
2Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
3Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
4Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
5Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
6Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
7Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
8Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
9Making plinth protection with common burnt clay bricks of class designation 7.5 laid on edge in cement mortar 1:6 (1 cement : 6 coarse sand) with 12 mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) over 75 mm bed of dry brick aggregate 40mm nominal size rammed, consolidated and grouted with fine sand. The top of bricks pointed with cement mortar 1:3 (1cement: 3 fine sand) and curing complete.
10Supplying and filling in plinth with fine sand under floors including, watering, ramming. consolidating and dressing complete.
11Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
12Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
13Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
14Centering and shuttering including strutting, propping etc. and removal of form for:
15Columns, pillars, piers, abutments, posts and struts.
16Chimney and shafts
17Suspended floors, roofs, landings, balconies and access platforms.
18Lintel, beams, plinth beams, girders, bressumers and cantilevers.
19Edges of slabs and breaks in floors and walls Under 20 cm wide
20Foundations, footings, bases of columns etc. for mass concrete.
21Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood
22Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
2312mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
2415mm Cement plaster on the rough side of single or half brick wall of mix: 1: 4 ( 1 cement : 4 fine sand)
256 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
26Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 35 mm thick
27Extra for providing and fixing flush doors with decorative veneering instead of non-decorative ISI marked flush door shutters conforming to ISI: 2202 (Part-I) On one side only
28Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood 35 mm thick
29Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class deodar wood 35 mm thick
30Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
31Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green. black of any size as approved by Engineer• in-Charge,skirting, risers of steps and dados over 12 mm thick bed of cernent mortar 113 ( I cement 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
32Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
33Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm
34Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
35200x10 mm
36150x10 mm
37Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete
38125 mm
39100 mm
40Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Twin rubber stopper
41Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
42Supply and laying of River Bed Materials including leveling, dressing, watering & consolidation in layer 20cm in depth each layer consolidated with power road roller of minimum 8 tonne capacity incl. carriages complete
43Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
44Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
45Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
46Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
47Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand)
48Extra for half Brick masonry in superstructure above plinth level upto floor V level.
49Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
50Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
51Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter
52Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compoundconsisting of applying(a) after surface preparation, first layer of slurry of cement @ 0.488kg/sqm mixed with water proofing cement compound@ 0253 kg/sqm(b) laying second layer of Fibre glass cloth when the first layer is stillgreen. Overlavxs of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cernent @1.289 kg/sqm mixed with water proofing cement compound @ 0_670kg]sqm_ and coarse sand kg/sqm. This will be allowed to aircure for 4 hours followed by water curing for 48 hours.The entire treatment will be taken upto 30cm on paravwt wall and tuckedinto groove in parapet all around.(d) fourth and final layer of brick tiling with cenwnt mortar (which will bepaid for separately)For the purpose of measurement the entire treated surface will be measured.
53Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness 8z size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and provn'r embeddingflaying of inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cutting of paver blcüs as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M 30 grade with approved color design and pattern.
54Carriage of Stone aggregate for an avg. Lead of 5 Km.
55Carriage of Sand for an avg. Lead of 2 Km.
56Carriage of Bricks for an avg. Lead of 5 Km.
57Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlleddevice (handle lever), conforming to IS:7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
58Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
59Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the wallswherever required :Kitchen sink with drain board510x1040mm bowl depth 250mm
60Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
61Providing and fixing toilet paper holder C.P. brass
62Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
63Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
64Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
65Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
66Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
67Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia
68Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mmCP Brass single hole basin mixer
69Providing and fixing PTMT swivelling shower, 15mm nominal bore, weighing not less than 40gms.
70Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 100 mm diameter
71Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
72Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes
73110 mm diametre
7475 mm diametre
75Providing 32 mm dia. C.P. brass trap.
76Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
77Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 100 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
78Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.
7915mm nominal outer dia pipes.
8020mm nominal outer dia pipes.
8125mm nominal outer dia pipes.
8232mm nominal outer dia pipes.
83Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing
8425mm nominal outer dia pipes.
8532mm nominal outer dia pipes.
86Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc.
8740mm nominal outer dia pipes.
88Providing and fixing uplasticized PVC connection pipe with brass unions 45 cm length 15 mm nominal bore
89Providing and fixing PTMT urinal cock of approved quality and colour : 18.76.1 15 mm nominal bore, 80 mm long, 42mm high and 30 mm wide with BSP female threads weighing not less than 48 gms
90Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
91Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
92Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
9325 mm nominal bore
94Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required. (Group A)
95Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
96Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.(1 x 1.5 sq. mm)
97Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
982 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
992 X 4 sq. mm + 1 X 4 sq. mm earth wire
1004 X 6 sq. mm + 2 X 6 sq. mm earth wire
101Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required
1023 pin 5/6 A socket outlet
1035/6 A switch
104Bell push
105Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
106Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providng andfixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required.
107Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
108Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
109Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required.
110Supplying & fixing suitable size GI box wih modular plate andcover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\"curve including connections, painting etc. as required.
111Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required.
112Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)
11312 way , Double door
1146 way , Double door
115Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator) (8 way (4 + 24), Double door)
116Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.
117Single Pole
118Single pole and neutral
119Triple pole and neutral
120Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required.
121Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required.
122Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm)
123Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
124Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
12540 watt
126Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim
12712 -15 watt
128Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., uitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
129180 watt
130Supply installation testing and commissioning of Chrome Finished Bracket Light with Standard Height of 300 mm and Opal Glass.
131Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.
1321200 MM
133Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.
1341400 MM
135Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of Metal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required .
136300 mm
137Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Meter Panel-1) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
138INCOMER
139MCCB 125 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
140MCCB 16 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
141Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set and other necessary relays Required to make it Functional as mentioned in the SLD
142150 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
14330 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
144OUTGOINGS
145MCB 32 A F.P 10 Ka with \\"C\\" Curve
1463Ph 4 W kWh Dir base mtg 240V 10- 60 A Acc 1 Energy Meter
147D.P M.C.B 10 A 10 Ka
148Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm, Types of wires:-PVC insulated 1100V grade , Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc., Gland Plates to be 3.0 mm Thick.
149Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Meter Panel-2) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
150INCOMER
151MCCB 125 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
152MCCB 16 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
153Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set and other necessary relays Required to make it Functional as mentioned in the SLD
154150 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
15530 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
156OUTGOINGS
157MCB 32 A F.P 10 Ka with \\"C\\" Curve
1583Ph 4 W kWh Dir base mtg 240V 10- 60 A Acc 1 Energy Meter
159D.P M.C.B 10 A 10 Ka
160Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm, Types of wires:-PVC insulated 1100V grade , Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc., Gland Plates to be 3.0 mm Thick.
161Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Meter Panel-3) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
162INCOMER
163MCCB 125 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
164MCCB 16 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
165Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set and other necessary relays Required to make it Functional as mentioned in the SLD
166150 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
16730 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
168OUTGOINGS
169MCB 32 A F.P 10 Ka with \\"C\\" Curve
1703Ph 4 W kWh Dir base mtg 240V 10- 60 A Acc 1 Energy Meter
171D.P M.C.B 10 A 10 Ka
172Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm, Types of wires:-PVC insulated 1100V grade , Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc., Gland Plates to be 3.0 mm Thick.
173Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55)Street Light Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
174INCOMER
175MCCB 63 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
176Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set and other necessary relays Required to make it Functional as mentioned in the SLD
177100 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
178Power Contactor 80A AC-1 Duty
179OUTGOINGS
180F.P M.C.B 16 A 10 KA \\"C\\" Curve
181Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm, Types of wires:-PVC insulated 1100V grade , Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc., Gland Plates to be 3.0 mm Thick.
182Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55)(Main L.T Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
183INCOMER
184MCCB 630 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
185MCCB 125 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
186125 A F.P Manual Changeover AC-23 Duty
187Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set and other necessary relays Required to make it Functional as mentioned in the SLD
188800 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
189200 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
190OUTGOINGS
191MCCB 125 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
192MCCB 63 A F.P 36 Ka with Adj.T.M.R With Icu=Ics=100%
193D.P M.C.B 16 A 10 KA \\"C\\" Curve
194MCB 16 A F.P 10 Ka with \\"C\\" Curve
195Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm, Types of wires:-PVC insulated 1100V grade , Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc., Gland Plates to be 3.0 mm Thick.
196Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.
1973.5 C X 300 Sq.mm A2XFY
1983.5 C X 70 Sq.mm A2XFY
1993.5 C X 25 Sq.mm A2XFY
2004.0 C X 10 Sq.mm A2XFY
201Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)
2023½ X 300 sq. mm (70mm)
2033½ X 70 sq. mm (38mm)
2043½ X 25 sq. mm (28mm)
2054 X 10 sq. mm (25mm)
206SITC of IP: 66/IP:67 PVC Junction Box having the Facility to house 4 way Bakellite strip for connection to the spike light.(Make:- Hensel)
207Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required.
208Supplying and Laying of Sheathed 3 C x 2.5 Sq.mm Copper Conductor Multistrand Wire IS:694.
209Supply,Installation of 3 Mtr 80 mm G.I Pole with Bracket for Housing 45 Watt Street Light Fixture with Foundation in concerete mix of 1:2:4.
210Supply installation testing and commissioning of 40W,Pole mounted IP65 Post Top with System efficacy of 100 lm/W.L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.
211Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required.
21263 mm dia (OD-63 mm & ID-51 mm nominal)
213200 mm dia (OD-200 mm & ID-175 mm nominal)
214Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
2151 or 2 Module (75mmX75mm)
216Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
217Telephone socket outlet
218TV antenna socket outlet
219Computer Socket RJ45 Modular type
220Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.
22125mm PVC Conduit
222Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit asrequired.
2232 Pair
224Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mmsolid copper conductor PE insulated, shielded with fine tinnedcopper braid and protected with PVC sheath in the existingsurface/ recessed steel/ PVC conduit as required.
225Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in theexisting surface/ recessed Steel/ PVC conduit as required.
2261 run of cable
227Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U' Marking, Minimum 2 cable entry / exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
2286U Rack
229Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc :-1)Type of Camera: Dome Camera 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night. 9) Video Compression (Minimum): H.265 or better,v Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 10) Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Water Marking 17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) ecording Management: Format SD, overwrite, storage management, video to NAS device,
2305MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as persite requirement) Dome Camera.
231Supply & Erection of CAT 6, 16 port Jack panel for termination of CAT6 cable,Testing & certification of the network with Omni/Penta Scanner of each Cable.
232Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
233Copper Patch Cords of length 1m (3ft)
234Supplying and drawing of 12 Pair Single Mode Optical Fibre Cables in the existing surface/ recessed Steel/ PVC conduit as required.
235Supply & Erection of Media Convertor complete as per specification and as desired by EIC.
236Supply & Erection of Termination Box complete as per specification and as desired by EIC.
237Supplying,Installation,Testing and Commissioning of 55 Inches Ultra H.D LED Display Monitor as per the Specifications attached.
238Supply , Installation , Testing and commissioning of 16 Channel NVR (Network Vedio Recorder) Embadded Linux based for recording upto 16CH @ D1 with 02 nos. SATA HDDs minimum 20TB storage or more (recording requirement all cameras recording at D1, 25fps for 30 days), H.265 HEVC/H.264/MJPEG codec decoding, Front Control Pannel with LEDs Indication, 2 nos. USB, ONVIF S, Time Sync with NTP, Encrypted Streaming & Control, 2-Way Audio Line & Out, PTZ Operation Pan, Tilt, Zoom, Support, Pre & Post Alarm Recording Support, Recording/Evidance Clip Export to USB, 16 Channel Syncronous Playback, Playback control i.e Play, Pause, Stop, Fast Forward, Backward, Timeline & Zoom; Snapshot, Web Client, Central Monitoring Softawre, iPhone; iPad; Android based Mobile clients, 01HDMI & 01VGA Output, 02 On Board HDDS each up to 10TB, Alarm Input (1 nos.), Alarm Output (01 nos.), NDAA Section 889 Compliant, Operating Temperature –10°C to 55°C, Certification : Certifications: ONVIF compliant, UL/CSA, CE, FCC, EN, NDAA & RoHS compliant.including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge.
239SITC of 6TB 7200 rpm SATA 6 Gb/s 3.5\\" Internal Enterprise Hard Drive
240Supply, Installation, Testing and Commissioning of 10/100/1000 Mbps Unmanaged Switches with Provision of 16 10/100/1000 Mbps ports as per specification and as desired by the Engineer Incharge.
241Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC
242Supply installation testing and commissioning of 2.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery.
243Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
24425 mm dia
24580 mm dia
246100 mm dia
247Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
248Single headed Gunmetal
249Supplying and fixing orifice plate made out of 6 mm thick Stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
250Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
251Gun Metal
252Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
253Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2542way - 100 mm dia M.S. Pipe
255Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
256Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
257Gun metal
258Providing and fixing Weather proof hose cabinets for yard hydrant fabricated from 16 g MS sheet with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 nos.15m long hose, 1 No branch pipe and one fireman's axe. The cabinet shall be painted with one coat of primer and finished stove enamelled \\"Fire Red\\", \\"Fire Hose\\" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 mx 0.25 m).
259Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
260Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure,horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plasteredand with anti vibration pads. 450 lpm at 35 m Head
261Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
262INCOMER
263MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%
264Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required.
265OUTGOINGS
266MPCB 19-25 A With STD. Magnetic Release
267Power Contactor 40 A415 Volts, AC-3 Duty
268Start/Stop Push Button
269Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm, Types of wires:-PVC insulated 1100V grade , Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc. Gland Plates to be 3.0 mm Thick.
270Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
271INCOMER
272MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%
273Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required.
274OUTGOINGS
275MPCB 19-25 A With STD. Magnetic Release
276Power Contactor 40 A415 Volts, AC-3 Duty
277Start/Stop Push Button
278Size of wiring for CTS:- 2.5 sqmm Size of wiring for voltage sensing Metering :-4.0 Sq.mm Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc. Gland Plates to be 3.0 mm Thick.
279Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD
280INCOMER
281MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%
282Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required.
283OUTGOINGS
284MPCB 19-25 A With STD. Magnetic Release
285Power Contactor 40 A415 Volts, AC-3 Duty
286Start/Stop Push Button
287Size of wiring for CTS:- 2.5 sqm Size of wiring for voltage sensing Metering :-4.0 Sq.mm Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc. Gland Plates to be 3.0 mm Thick.
288Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
289100 mm dia
290Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
291100mm dia
292Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
293100mm dia
294Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
295Providing, installation, testing and commissioning of Pressure Guages
296Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of eration/communication suitable for 20 Nos.talk back unit -1 set. Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector,ON/OFF switch, fuse, visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set.
297Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
298Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
299Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
300Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.
301Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3022 x 1.5 sq. mm
303Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
30425 mm
305Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683)suitable for Class A/B/C Type Fires . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57637708
AUTHORITY Government Departments
TENDER VALUE 7.89 Crore
LAST DATE 12-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Residential Accomodation Of District Development Council /Pris At Samba District Samba (Under Ut Capex Budget).
Basic Detail
Tender No e-NIT No.PWD/SE/KS/43 of 2026-27 Dated 21-09-2026
Bidding Type Tender
Location
City Kathua
State Jammu and Kashmir
Key Dates
Publish Date 22 Sep 2026
Submission Date 12 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 7.89 Crore
Tender Fee 6000
EMD 15.79 Lakhs
Exemption Not Available
Document List
9264ea39-ecbf-4f81-aae6-24c9d23bbfaf.html
BOQ_1100505.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

9264ea39-ecbf-4f81-aae6-24c9d23bbfaf.html

xls

BOQ_1100505.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders