Water Resources and Irrigation Government Departments Closing in 8 days TDR #57635642

Tender For Lwss Dehra Barpat Intehsil Sundernagar Distt. Mandi (Hp) (Sh:- Providing , Fixing And Installation Of New Centrifugal Pump For Lwss Dehra Barpat).

Issued by Government Departments · Mandi, Himachal Pradesh
Tender Value
3.31 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
8 days left
EMD
6650
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mandi → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Lwss Dehra Barpat Intehsil Sundernagar Distt. Mandi (Hp) (Sh:- Providing , Fixing And Installation Of New Centrifugal Pump For Lwss Dehra Barpat).

BOQ

Name of Work:- LWSS Dehra Barpat inTehsil Sundernagar Distt. Mandi (HP) (SH:- Providing , fixing and installation of new centrifugal pump for LWSS Dehra Barpat).
Sl. No. Item Description
1Providing horizontal spindle, horizontal/redial split cashing/ end suction (Back-pull out arrangements) single/double/multi stage cetrifugal pump or combiantion of pumps, in series/parallel of recommended make such as Mather and Platt/KSB/ Beason Weir/Kirloskar/BE/Jyoti as per BIS 1520-1980 with upto date ammmendments, read with IS:91371978 or latet edition suitable for lifting water for under mentioned characterestics with bronze, impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel gade 4508 FN8 with cast iron casing coupled directly throgh a flexible couppling on a comon MS/cast steel base plate (base plate to be from the manufactur of the pumping unit only) to squireel cage scren protected drip proof induction motor /motors of standered make such as Kirloskar/BHEL/Crompton/NGEF/GEC/Siemens/Jyoti/ABB of IE2 or above rating and suitable for operation on 400 (+/-)10% voldts, 50 cycles/ second 3 phae AC electric supply The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor/motors as per ISI :325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing uts, bolts and painting etc. and should meet the following requiremtns. Discharge (Q) = 1.3 LPS, Static Head =200 Mtr.
2Providing and fixing of oil immersed star delta starter MEI/Jyoti/L&T make conforming to BIS-8544-1979 latest with upto date ammendments for 25 HP squireel cage motor mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling.
3Providing and fixing MS sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 50x50x6mm duly powder coated comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge. (a) Supply of 100mm VAF meter for Digital display of Amp., Volt and freq. standard make such as Sunvij/Schneider/Enercon/L&T/Indoasian make with selector switches conforming to ISO specifications BIS-1248-1983 latest with uptodate ammendments. (b ) Main MCCB of standard make such as Indoasian/Siemen/Standard/ Havells/ABB/L&T make and having capacity 30% extra of the operational rating of motor as per BIS- 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. (c) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments. (d) ICTP switch with HRC fuses of suitable capacity of L&T/Standard/Havells/ ABB/ Indoasian make on for indivisual motors offered by the tendrerer conforming to BIS 4064-1985 latest with upto date ammendments with neutral linked under voltage release. (e) 3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS-3452 part-I & II latest with upto date ammendments. (f) Earth fault relay with shunt trip of standard make such as Indoasian/L&T/Standard/Havells/ Schneider with upto date ammendments and of suitable range. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/off breaker load side. (g) Hour run meter of Digital display conforming to BIS-722 (latest edition) recommendations. (h) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage, high voltage & over loading & phase voltage differenece. (i)Change over switch of reputed make and suitable capacity (j) Single phase preventor of reputed make & suitable capacity
4Providing and fixing of Kilburn/KSB/Leader/Pelican make of suitable size cast steel Class ASA 600 double flanged sluice valve minimum one size higher than outlet size of pump capable of withstanding nominal seat pressure of 104 kg/cm^2 conforming to BS 1414 (API 600) latest with upto date ammendments.
5Providing and fixing of Kilburn/ Fouress/Leader/KSB/Pelican make of suitable size Cast Steel class-ASA 300 double flanged swing check type reflux valve minimum one size higher than outlet size of pump withstanding nominal seat pressure 104kg/cm^2 conforming to BS 1868 (API 600) latest with upto date ammendments.
6Providing and fixing of Kirloskar/Kilburn/Fouress/Gled/Leader/KSB/Pelican make of 150mm dia cast steel class-ASA 300 double flanged swing check type reflux valve size equal to dia of R/Main for withstanding nominal seat pressure of 104 kg/cm^2 conforming to BS 1868 (API 600) latest with upto date ammendments.
7Providing and fixing of Kirloskar/Kilburn/IVC/Fouress/Gled/Leader/KSB/Pelican/Kartar make suitable size cast iron PN-1.6 double flanged sluice valve size having conforming to IS: 14846/IS 780 having min one size higher than suction size of pump and capable of withstanding nominal seat pressure of 10 kg/cm^2
8Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part I) 1988 or latest with upto date ammendments Siemen/Gloster/L&T/ Standard/Finolex make from meter of HPSEB to MCCB & from MCCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
9Providing and laying jointless three core copper PVC insulated suitable size cable as per BIS 694-1990(latest with upto date ammendments) Gloster/Havells/Standard/L&T/Finolex make suitable for the pump set offered from MCCB to starter, starter to motor including all other electrical equipments such as Thimbles, flexible pipes, solder, nuts & bolts cable glands etc. laid in pipes or trenches. The type, size & make will be subject to approval of HPSEB authorities. In case of non-acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
10Providing and laying double loop earthing with GI plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, 25x5mm GI strips of required capacity conforming to BIS 3043-1987 latest with upto date ammendments for above motors & other electrical equipment.
11Supply & erection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834- 1986 latest with upto date ammendments L&T/Havells make to raise the prevailing power factor at site to 0.95 for direct connection to inductiion motor individually of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses. Range to be specified by the tenderer
12Providing and fixing of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision/H Guru make with all accessories such as stop cock, copper tubing etc. conforming to BIS-3624-1987 latest with upto date ammendments
13Providing and laying delivery pipe, suction pipe considering site requirements, NPSH required and available & common header having area equal to two times the area of delivery branch of pump including tappers, flanges, rubber gaskets, less than 3mm thick as per BIS-2712-1978, nuts and bolts as per 1364-1983 & special upto 5 mtrs. away from the outer wall of pump house as per layout drawings approved by the Engineer-in-charge. The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item No. 1 E(ii) The detail of pipes and flanges shall be as under:-Suction :- GI pipe 65mm dia Flange Table-5Delivery pipe:- GI pipe 40mm dia with flange Table-28Note Actural laying to be done as per final drawings to be approved by the Engineer-in-charge.
14Errection of all equipments from Sr. No. 1 to 4, & 6 including cost of tees, bends, tapers & any other fittings required as per site conditions & as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57635642
AUTHORITY Government Departments
TENDER VALUE 3.31 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Irrigation And Public Health Department
Work Description Tender for Lwss Dehra Barpat Intehsil Sundernagar Distt. Mandi (Hp) (Sh:- Providing , Fixing And Installation Of New Centrifugal Pump For Lwss Dehra Barpat).
Basic Detail
Tender No EE JSD SNR TA etender 2026-14592-14615 dt. 21.09.2026
Bidding Type Tender
Location
City Mandi
State Himachal Pradesh
Key Dates
Publish Date 22 Sep 2026
Submission Date 01 Oct 2026
Open Date 03 Oct 2026
Finance
Tender Value 3.31 Lakhs
Tender Fee 350
EMD 6650
Exemption Not Available
Document List
920c9b47-7bbf-4391-b0e5-102147630414.html
BOQ_214048.xls
Form6.pdf
Form8.pdf
Tendernotice_1 (20).pdf
Termsandconditions.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

920c9b47-7bbf-4391-b0e5-102147630414.html

xls

BOQ_214048.xls

pdf

Form6.pdf

pdf

Form8.pdf

pdf

Tendernotice_1 (20).pdf

pdf

Termsandconditions.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders