Tender For Construction Work Of Land Levelling, Boundary Wall, Security Room, And Approach Road For The Installation Of A Doppler Radar At The Indian Institute Of Sugarcane Research Located In Telibagh, Lucknow. (Building Work)
Tender Overview
Project Description
Tender for Construction Work Of Land Levelling, Boundary Wall, Security Room, And Approach Road For The Installation Of A Doppler Radar At The Indian Institute Of Sugarcane Research Located In Telibagh, Lucknow. (Building Work)
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in trenches for foundation for pipes.cable etc in oridinary soil incl. lift up to 1.5 m and lead upto50 m & dressing of dides & ramming the bottom & disposal of surplus earth as per direction of E/I |
| 2 | P.C.C. work with cement approved coarse sand and 40 mm gauge approved stone ballast in proportion of 1:4:8 incl. cost of form work in foundation & floor |
| 3 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 4 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 6 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 7 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. |
| 9 | Class-150 brick work in 1:6 cement and COARSE sand mortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. |
| 10 | Class-150 brick work in 1:6 cement and COARSE sand mortar in SUPERSTRUCTURE including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work |
| 11 | 12 mm cement plaster in single coat on smooth side of single or half brick wall for interior plastering upto floor two level including brick wall for interior plastering upto floor two level including internal rounded angles chamfers and/or rounded angles not exceeding 80mm in girth and finished evenand smooth no. extra for mixing and additive. (iii) 1cement :6 C. sand |
| 12 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering upto floor two level including internal rounded angles not exceeding 80mm in girth and finished even and smooth (i) 1 cement: (iii) 1 cement: 6 coarse sand |
| 13 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 14 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 15 | Painting two coats over priming coat on steel & other metal surfaces up to 10 cm width or sq,mt in areas with superior synthetic enamel such as Luxol-3 Hi-gloss apcolite superlac, Dulux specified finishing to give an even shade & incl. cleaning the surface of all dirt, dust & other foreighn matter sand preparing and knotting incl. cost of all etc. required for proper completion of work. |
| 16 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil |
| 17 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete for all lift. |
| 18 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8.00Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distsnce of 50m out side the periphery of area cleared. under floor Local Sand |
| 19 | Providing and laying Cement concrete 1:4:8 (1cement :4 C. sand :8 graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. |
| 20 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 21 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 22 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 24 | Suspended floors, roofs, landings, balconies and access platform |
| 25 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 26 | Under 20 cm wide |
| 27 | Class-150 brick work in 1:6 cement and COARSE sand mortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 29 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3)treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sq.m. |
| 30 | Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. |
| 31 | Providing and fixing SS sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm. |
| 32 | Providing and fixing SS tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm. |
| 33 | Providing and fixing SS handles ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm. |
| 34 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 150x10 mm. |
| 35 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm. |
| 36 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) ONE SIDE decorative type & OTHER SIDE BALANCING , core of block board construction with frame of 1st class hard wood and with decorative both side high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality of 1.0 mm thick including 32x5 mm teak wood lipping on edges of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 37 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 38 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 39 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 40 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 41 | Mild steel or iron work of small size and sections such as holding down bolts, hold fast, tie rods, grating etc, (when not included in an overall rates) wrought to required shape as necessary for bending etc including supply fo steel and its wastage including cost of bolts, nuts if required, welding, grinding and making holes as required for completion of work but Fabrication of Z-section Openable Steel windows, including necessary steel windows,including necessary steel fitting such as handles stay etc. |
| 42 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick |
| 43 | Mild steel or iron work of small size and sections such as holding down bolts, hold fast, tie rods, grating etc, (when not included in an overall rates) wrought to required shape as necessary for bending etc including supply fo steel and its wastage including cost of bolts, nuts if required, welding, grinding and making holes as required for completion of work butFabrication of Grill/Stairs case railing |
| 44 | 12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On smooth surface of wall. |
| 45 | 15 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On rough surface of wall. |
| 46 | 12 mm thick plaster with cement mortar in consisting of 1:3 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. In ceiling |
| 47 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) On plinth. |
| 48 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 49 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 50 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 51 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 52 | Providng and fixing Granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen plateforms, vanity counters, windows sills, facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4(1 cement : 4 coarse sand). |
| 53 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick |
| 54 | Distempering (two coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N Shalimar, Asian Paints after thoroughly brushing the sufface free from mortar dropping and other forein matter and also including prepairing the surface even with Plaster of Paris or approved synthetic material and sand papered smooth including cost of all material |
| 55 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 56 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 57 | Painting two coats over priming coat on steel & other metal surfaces up to 10 cm width or sq,mt in areas with superior synthetic enamel such as Luxol-3 Hi-gloss apcolite superlac, Dulux specified finishing to give an even shade & incl. cleaning the surface of all dirt, dust & other foreighn matter sand preparing and knotting incl. cost of all etc. required for proper completion of work. |
| 58 | Painting two coats over priming coat on wood surfaces up to 10 cm width or sq,mt in areas with superior synthetic enamel such as Luxol-3 Hi-gloss apcolite superlac, Dulux specified finishing to give an even shade & incl. cleaning the surface of all dirt, dust & other foreighn matter sand preparing and knotting incl. cost of all etc. required for proper completion of work. |
| 59 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 60 | Brick edging 7cm wide 11.4cm. deep to plinth protection with bricks of class designation 75 including grouting with cement mortar 1:4 (1 cement : 4 fine sand) |
| 61 | Supply & Filling of Cinder in sunken portion of building including breaking into required sizes including supply of all material, labour, T&P required sizes including supply of all material, labour, T&P required for proper completion of work. |
| 62 | APRON DRAIN |
| 63 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 64 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 65 | Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. 610x510 mm bowl depth 200 mm. |
| 66 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 67 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete32 mm dia |
| 68 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia. |
| 69 | Providing and laying of PVC (SWR) pipes with necessory fittings, single socketed in any length with rubber ring joints, laid in walls, trenches or in floors necessary accessories and solvent cement etc. complete. 110mm DIA |
| 70 | Providing and laying of PVC (SWR) pipes with necessory fittings, single socketed in any length with rubber ring joints, laid in walls, trenches or in floors necessary accessories and solvent cement etc. complete. 75mm DIA |
| 71 | Providing and fixing PVC (SWR) pipe Clip including fixing with nuts, etc and making good the walls complete. 100mm DIA |
| 72 | Providing and fixing PVC (SWR) Plain Bend including jointing with solvent cement etc. complete 100mm DIA |
| 73 | Providing and fixing PVC (SWR) Plain Bend including jointing with solvent cement etc. complete 75mm DIA |
| 74 | Providing and fixing PVC (SWR) Plain Bend 90 Degree including jointing with solvent cement etc. complete 100mm DIA |
| 75 | Providing and fixing PVC (SWR) Coupler including jointing with solvent cement etc. complete 100mm DIA |
| 76 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Sand cast iron S&S as per IS: 3989 |
| 77 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 78 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15mm nominal dia Pipes |
| 80 | 20mm nominal dia Pipes |
| 81 | 25mm nominal dia Pipes |
| 82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm nominal dia Pipes |
| 83 | 20 mm nominal dia Pipes |
| 84 | 25 mm nominal dia Pipes |
| 85 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 86 | 20 mm nominal bore |
| 87 | 32 mm nominal bore |
| 88 | Providing and fixing uplasticised PVC connection pipe with brass unions :20 mm nominal bore |
| 89 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter |
| 90 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 91 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 92 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 93 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 94 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 95 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 96 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm |
| 97 | 110 mm Shoe |
| 98 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 99 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 100 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 101 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 102 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 103 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 104 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X2.5 sq. mm + 1X2.5 sq. mm earth wire |
| 105 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 106 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 107 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 108 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 109 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 110 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 111 | 15/16 A switch |
| 112 | 3 pin 5/6 A socket outlet |
| 113 | 6 pin 15/16 A socket outlet |
| 114 | Telephone socket outlet |
| 115 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 116 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 117 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 118 | 3 Module (100mmX75mm) |
| 119 | 4 Module (125mmX75mm) |
| 120 | 6 Module (200mmX75mm) |
| 121 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep |
| 122 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 123 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 124 | Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 125 | Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 126 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A.30KA.FPMCCB |
| 127 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 4 way (4 + 12), Double door |
| 128 | 8 way (4 + 24), Double door |
| 129 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 130 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 131 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 132 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 133 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 134 | Supply & Fixing of AC 1400mm Sweep, 230/250 Volts, 50 Hz ceilling fan without regulator, standard down rod, blades etc. complete as required. (Standard - Plain Ceiling Fans) |
| 135 | Supply & Fixing of AC 300mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Heavy Duty) with blades,cover etc. complete as required |
| 136 | Supply & Fixing of AC 230mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Light Duty) with blades,cover etc. complete as required |
| 137 | Supply & Fixing of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including making connection.Complete in all respect. |
| 138 | Recessed LED Downlighter ,made up of pressure die cast aluminum housing with high efficiency Prismatic PS diffuser, LED Used shall be SMD type and fixture should have minimum efficacy at System level >=110 lumens/watt with Minimum system Lumens 1400 & max wattage 13.5W, Life of fixture : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<=5), CRI Ra >=80, PF >0.9, an Operating working temp range - 0°C < Ta < 45°C & operating Voltage Range of 130-320 V AC. Ceiling cut-out Min 150mm & Height of downlighter Min 40mm. Minimum Internal Surge Protection 2.5KV. The fixture design should be with flicker free operations ripple <5%, comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI/EMC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. (15 w) |
| 139 | Supply, Installation, Testing and Commissioning of LED 4ft Linear with a nominal system lumen output of 2000 lumens and a minimum system efficacy of >130 lm/w @6500K. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80,SDCM<=5. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The Luminaire should (Flicker Free Ripple < 5% ), Hi-low cutoff circuit with auto restart feature & 4KV surge for better protection against voltage fluctuation/spikesThe luminaire housing should made of CRCA with a PC glossy diffuser. The total power consumption should not exceed 16 W (including driver). Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Fixture and driver have to be BIS certified as per the govt rule. (22w) |
| 140 | Supply & Fixing of LAN socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 141 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core |
| 142 | 35 sq. mm 3-1/2 core |
| 143 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 16 sq. mm 4 core |
| 144 | 35 sq. mm 3-1/2 core |
| 145 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as perdirection of the Engineer-Incharge. 16 sq. mm |
| 146 | 35 sq. mm |
| 147 | K.S.B. make Submersible pumpset 5.0 H.P. discharge 600 L.P.M. |
| 148 | Control panel board with starter 32 amp. Main switch kit-kat Etc. |
| 149 | 80 mm dia M.S. Column Pipe \\"C\\" Class (3.0m) |
| 150 | 80 mm dia M.S. Column Pipe \\"C\\" Class (1.5m) |
| 151 | 80 mm dia M.S. Column Pipe \\"C\\" Class (1.0m) |
| 152 | 80 mm dia M.S. by pass arrangement (2.0m) |
| 153 | 80 mm dia C.I. D/F Sluice valve I.S.I |
| 154 | 80 mm dia C.I. D/F N.R.V. I.S.I |
| 155 | 80 mm dia C.I. D/F Tey Heavy Duty |
| 156 | 80 mm dia C.I. D/F Band |
| 157 | 80 mm dia M.S. Clamp |
| 158 | 80 mm dia Rubber Packing |
| 159 | Flat copper Cable 1x3x6.00 mm2 |
| 160 | Nut, Bolt, Washer |
| 161 | Motor safety clamp |
| 162 | Cartage up down |
| 163 | Pump Guard |
| 164 | Installation of Pump-set |
| 165 | Earth work in exacavation in trenches for foundations land for pipes cables etc. in ordinary soil (loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m For Septic Tank |
| 166 | Add extra for additional lift of 1.5m and additional lead 1.5m to 3.0m |
| 167 | Providing and laying Cement concrete 1:4:8 (1cement :4 fine sand :8 graded brick aggregate 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. |
| 168 | RCC M 20 in beam |
| 169 | R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 in slab, excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work. Binding wire cost being included in the item. Slab |
| 170 | Suspended floors, roofs, landings, balconies and access platform Slab |
| 171 | Lintels, beams, plinth beams, girders, bressumers and cantilevers RCC M 20 in beam |
| 172 | Thermo-Mechanically Treated bars work such as reinforced concrete or reinforced brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of work and including supply of all steel and wastage & over lapping and hooks. |
| 173 | M-150 brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour and tools and plants etc required for proper completion of work. |
| 174 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 175 | 15 mm cement plaster |
| 176 | Foot Step (5 kg/sqm.) (DSR 19.15.1) |
| 177 | C.I. Pipe (100 mm dia) (DSR 17.35.1.2) |
| 178 | C.I.cowel. |
| 179 | C.I. plain bend. |
| 180 | C.I. single equal plain junction. |
| 181 | 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender