Tender For Special Repair For Conversion Of Acsr Conductor To Lt Ug Cable At Ncc, Aro And Uav Kumbhigram Alongwith Associated Work Services Under Masimpur Mil Stn
Tender Value
46.10 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
17 days left
EMD
92200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair For Conversion Of Acsr Conductor To Lt Ug Cable At Ncc, Aro And Uav Kumbhigram Alongwith Associated Work Services Under Masimpur Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | E & M Division Items |
| 2 | Dismantling of old unserviceable/damaged ACSR or AAC conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed. |
| 3 | Dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of PCC and removing unserviceable meterials from site of work complete all as specified and directed. |
| 4 | Dismantling of cross-arms of MS channel or angle of any sections complete all as specified and directed. |
| 5 | Dismantling of insulators of any size/type complete all as specified and directed. |
| 6 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 7 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 8 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 35 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 9 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 50 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 10 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 70 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 11 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 95 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 12 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 120 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 13 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 150 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 14 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed. |
| 15 | Returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 16 | Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed. |
| 17 | Supply and laying burnt bricks of sub-class 'B' of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 18 | Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note: Thickness of sand cushioning after punning down will be measured and paid separately. |
| 19 | M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified |
| 20 | Supply and fix HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP -65 protection of size 205x210x112 with 60 Amp 4 way heavy duty terminal block with 10 Amps MCB SP with two steel bracket to fix with pole complete all as specified and directed by Engr - in - charge. |
| 21 | Supply and laid Pipes galvanized 'medium grade for cable protection complete of 40mm dia complete including taking down old unserviceable pipe all as specified and directed by Engineer-in-Charge. Make :- TATA/ Zindal/Zeenith |
| 22 | Supply and laid Pipes galvanized 'medium grade for cable protection complete of 50mm dia complete including taking down old unserviceable pipe all as specified and directed by Engineer-in-Charge. Make :- TATA/ Zindal/Zeenith |
| 23 | Supply and laid Pipes galvanized 'medium grade for cable protection complete of 80mm dia complete including taking down old unserviceable pipe all as specified and directed by Engineer-in-Charge. Make :- TATA/ Zindal/Zeenith |
| 24 | S&F GI bracket fixing in repairs suitable for street light fitting made out of 40mm dia GI tubing of light grade bent to shape of 1.5m length complete including taking out old one complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F PVC non-metallic conduit pipe 20mm bore complete all as specified and directed. |
| 26 | S&F in replacement LED street light 60 watt (incl 10 KV SPD), pressure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP-66 protection having efficiency > 110 LPW /125LPW, mounting on existing/new bracket incl all fixing arrangement on any size of pole complete all as specified and directed. Please Enable Macros to View BoQ information |
| 27 | S&F in replacement LED street light 60 watt (incl 10 KV SPD), pressure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP-66 protection having efficiency > 110 LPW /125LPW, mounting on existing/new bracket incl all fixing arrangement on any size of pole complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysOct 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender