Tender For annual maintenance contract For Staff Quarters Of Iip( Elecrtical Works) 2026-27.
Tender Value
11.76 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
5 days left
EMD
23530
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for annual maintenance contract For Staff Quarters Of Iip( Elecrtical Works) 2026-27.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Sep-2026 | Requirement of additional document | Technical Bid | 01-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 2 | 2x1.5 sq mm + 1x1.5 sq mm earth wire |
| 3 | 2x2.5 sq mm + 1x2.5 sq mm earth wire |
| 4 | 2x4 sq mm +1x4 sq mm earth wire |
| 5 | 2x6 sq mm + 1x6 sq mm earth wire |
| 6 | Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 7 | 3 X 1.5 sq mm |
| 8 | 3 x2.5 sq mm |
| 9 | 3 x 4 sq mm |
| 10 | 3 x 6 sq m |
| 11 | Supplying and replacement of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | 20 mm |
| 13 | 25 mm |
| 14 | Supplying and replacement metal box of following size (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 15 | 100 mmx 100 mmx 60 mm deep |
| 16 | 180 mmx 100 mmx 60 mm deep |
| 17 | 200 mmx 125 mmx 60 mm deep |
| 18 | Supplying and replacement following piano type switch/ socket on the existing switch box/ cover including connections etc as required. |
| 19 | 5/6 amps switch |
| 20 | 2 way 5/6 amps switch |
| 21 | 15/ 16 amps switch |
| 22 | 3 pin 5/6 amps socket oulet |
| 23 | 6 pin 15/ 16 amps socket oulet |
| 24 | bell push 5 A |
| 25 | Supplying and rplacement of following modular switch/ socket on the existing modular plate and switch box/ cover including connections etc as required. |
| 26 | 5/6 amps switch |
| 27 | 15/ 16 amps switch |
| 28 | 3 pin 5/6 amps socket oulet |
| 29 | 6 pin 15/ 16 amps socket oulet |
| 30 | Supplying and replacement of two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding plate etc as required. |
| 31 | Supplying and replacement of following size/ modules, GI box along with modular base & cover plate for modular switch in recess etc as required |
| 32 | 3 module (100 mm x 75 mm) |
| 33 | 6 module (200 mm x 75 mm) |
| 34 | 8 module (125 mm x 125 mm) |
| 35 | 12 module (200 mm x 150 mm) |
| 36 | Supplying and replacement of suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As required |
| 37 | Supplying and replacement of 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 38 | Supplying and replacement of call bell/ buzzer suitable for single phase, 230 volt complete as required |
| 39 | Extra for fixing the louvers/ Shutters completee with frame for a exhaust fan of all sizes. |
| 40 | Supplying and replacement of PVC batten/ angle holder including connection etc. as required |
| 41 | Supplying and replaement of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 42 | 12 way , Double door |
| 43 | Supplying and replacement 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 44 | single pole |
| 45 | Single pole and neutral |
| 46 | Double pole |
| 47 | Tripple pole and neutral |
| 48 | Supplying and replacement of following rating, double pole, (single phase and neutral) 240 V , residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc as reqired. |
| 49 | Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/ Lighitng DBs for automatic switching On & OFF of street lights at sun set & sun reise or twilight (Auto ON,OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 50 | 1 out put per phase suitable for single phase supply |
| 51 | Supplying and fixing cable route marker with 10 cm X10 cm X 5 mm thick G.I. plate with inscription there on,bolted /welded to 35 mm X 35 mm X 6 mm angle iron,60 cm long and fixing the same in ground as required. |
| 52 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 53 | Above 4.5 Meter and upto 6.5 Meter |
| 54 | Providing and laying cement concrete for pedestal of electric pole including shuttering along with demolishing of exisiting cement concrete base with complete as per directions of Engineer-in-Charge [Each Pedestal size: 0.3 X 0.3 X 0.45 mtr) Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 55 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix)[50 Pedestals of 0.04 Cum each] |
| 56 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 57 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) [50 Pedestals of 0.04 Cum each] |
| 58 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 59 | Foundations, footings, bases of columns, etc. for mass concrete [50 Pedestals of 0.54 sqm each] |
| 60 | Supplying and embedding following dia G.I Pipe (medium class) in pole collar/ foundation during casting for cable entry including bending the pipe to the rquired shape complete as required. |
| 61 | 32 mm dia |
| 62 | Supplying and fixing 32/40 mm dia x 2.00 meters long G.I pipe (meidum class) bracket for mounting of fiuorscent/ HPMV/ HPSV street light fitting on pole including bending shape, 2 nos. 40 mmx 3mm flat iron clamps with nuts, bolts andthe pipe to the require washer, painting the flat iron primer and finish piant etc as required. |
| 63 | Supply of Electrician (Skilled) & Helper (Unskilled) on per day basis throught out the year for Operation and maintenance (Routine/ Preventive/ Breakdown) and day to day maintenance of IIP Staff quarter area with necessary tools and associated of entire electrical installation including tube wells maintenance with repairing/servicing of motors, Pumps,distribution baords, LT Panels Internal & outer electrification system of staff quarters area of IIP Building Note:- The Rate is inclusive of EPF, ESI and all other taxes as applicable and required for the works, no any additional payment will be made in this regard.Rates shall not be qouted less than applicable minmum wages including all charges, else tender wil be rejected.) ( Scope of work and term and conditions for deployment of manpower is including as per Annexure- 1). |
| 64 | Electrician (Skilled Mandays) |
| 65 | Helper (Unskilled Mandays) |
| 66 | Supply and replacemant of capacitor of ceiling fans/ exhaust fan/ wall fan/ padestal fan of size of 2.5 to 4 mfd etc as required |
| 67 | Supplying and laying folowing size of PVC insulated Aluminium flat twin core weather proof cabe in existing pipe or surface etc as required. |
| 68 | 3x6 sq mm |
| 69 | Supply & replacement of Pole mounted SMC/PVC/FRP junction box for street lighting for 1 phase/3 phase high wattage HPSV/HPMV/MH based lighting system including terminal blocks suitable for 16Sqmm Size , 2 Amps MCB SP , Cable entry from bottom ,Weatherproof and shall be suitable for Pole mounting arrangement etc. as required.minimum size 200 X 140 X 95 |
| 70 | Repair and replacement of defective (Inclusive cost of buy back old celing fan) ceiling fan with 1200 mm sweep blades, high speed 400 RPM including supply making connections and accessories etc. complete as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Oct 01, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender