Public Administrative Department Local Bodies Closing in 4 days TDR #57631406

Tender For Provision Of 12M Shm Pole Along With Its Allied Accessories In Municipal Parks Near H. No. 7/30, H. No. 7/38, H. No. 7/20, H. No. 5B/35, H. No. 5B/9 Tilak Nagar In Ward No.-101 Tilak Nagar Under West Zone.

Issued by Local Bodies · Delhi, Delhi
Tender Value
19.25 Lakhs
Estimated cost
Bid Submission
28 Sep 2026
4 days left
EMD
38900
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of 12M Shm Pole Along With Its Allied Accessories In Municipal Parks Near H. No. 7/30, H. No. 7/38, H. No. 7/20, H. No. 5B/35, H. No. 5B/9 Tilak Nagar In Ward No.-101 Tilak Nagar Under West Zone.

BOQ

Name of Work:- Provision of 12m SHM Pole along with its allied accessories in Municipal parks near H. No. 7/30, H. No. 7/38, H. No. 7/20, H. No. 5B/35, H. No. 5B/9 Tilak Nagar in Ward No.-101 Tilak Nagar Under West Zone.
Sl. No. Item Description
1Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
2Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
3Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
5Supplying and erection of galvanised ‘D’ iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
6Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
7Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
8Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
9Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
10Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 45 Watt
11Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg, suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100 Watt
12Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos. and reinforcement of cold twisted bars of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts 16 mm dia, 600 mm long, J type i/c 2 nos. template anchor plates of size 225 mm x 225 mm x 3 mm and providing DCW HDPE for cable entry & exit as required for 3 m and 5 mtr pole.
13Fabrication, supply & erection of 5.0 mtr height, minimum 3mm thick, bottom dia of 130mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/c providing and fixing DIN channel of suitable length, 6 Amp. SPMCB ‘C’ curve characteristics, earth stud, cable support clamp suitable for Upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plate on the Pole. Galvanization as per relevant IS code etc. as required.
14Fabrication, Supplying, Installation, testing, commissioning, of 12 mts. semi high mast system with its accessories, Mast shaft shall be in one section, hot dip galvanized 4mm thick(single dip) inside and out sides & suitable for wind velocity as per IS 875 part3. There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories for High Mast head frame, 2 point suspension system, 5x2.5 sqmm Copper conductor with steel wire rope 5mm dia. (7/19 construction) single drum winch, galvanized lantern carriage arrangement suitable for 4/6 nos. flood light luminaries symmetrically and its control gear boxes and lighting finial, the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)x1m wide and 2m deep i/c excavation of earth , providing cutting, bending and placing in position, reinforcement of cold twisted bar of 12 mm dia-2100mm long (approx.)-16 nos. and reinforcement of cold twisted bar of 8 mm dia- 3700 mm (approx.)-13 nos. (with 150 mm spacing ) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the semi high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4 nos S.P MCB, 1 no. Double pole 16Amp. MCB etc. as reqd. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole. Galvanization as per relevant IS.
15Providing and fixing name board made of MS sheet 90x60cm, 1mm thickwith frame of MS angle 50x50x6mm, two diagonal braces at the vback of sheet of MS flat 40x6mm, total height of the board above ground level 2.40mtr, length of legs below ground level 0.30 mtr embedded in CC block 1:2:4 (1 cement: 2 coarse: 4 graded aggregate 20 mm nominal size) 30x30x45 cm excluding excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/ direction of Engineer-in-charge
16Supply and fabrication of pole protection system made up of 8 SWG steel wire mesh of size 25mm x 75mm rectangular with 50mmx 50mmx 6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc. as reqd.
17Fabrication, supplying and fixing Class B Galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 32 mm dia galvanized pipe with tightening bolts complete as required.
18Fabrication, supplying and fixing Class B Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 32 mm dia galvanized pipe with tightening bolts complete as required.
19Supply of XLPE insulated PVC sheathed Al.conductor Armoured Cable 1.1 KV grade conforming to IS-7098 of following Size:- 2 x 6 sqmm
20Providing and fixing of Stainless steel name plate of size 6x8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57631406
AUTHORITY Local Bodies
TENDER VALUE 19.25 Lakhs
LAST DATE 28-09-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of 12M Shm Pole Along With Its Allied Accessories In Municipal Parks Near H. No. 7/30, H. No. 7/38, H. No. 7/20, H. No. 5B/35, H. No. 5B/9 Tilak Nagar In Ward No.-101 Tilak Nagar Under West Zone.
Basic Detail
Tender No E.E(Elect.)/WZ/2026-27/NIT No.54
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 21 Sep 2026
Submission Date 28 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 19.25 Lakhs
Tender Fee 590
EMD 38900
Exemption Not Available
Document List
5402CoditionsandCircular.pdf
5402DNIT.pdf
5402GCC.pdf
5402Schedule.pdf
6f18e91c-98b0-43b4-af91-19c9a6b58be5.html
BOQ_340008.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

5402CoditionsandCircular.pdf

pdf

5402DNIT.pdf

pdf

5402GCC.pdf

pdf

5402Schedule.pdf

html

6f18e91c-98b0-43b4-af91-19c9a6b58be5.html

xls

BOQ_340008.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders