Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57631373

Tender For Repair And Maintenance Of Leakage/ Seepage In Md/Otm Accn At Mil Station Subathu Under Ge Kasauli.

Issued by Statutory Bodies & Commissions/Committees · Solan, Himachal Pradesh
Tender Value
48 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
17 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Leakage/ Seepage In Md/Otm Accn At Mil Station Subathu Under Ge Kasauli.

BOQ

Name of Work:- REPAIR AND MAINT OF LEAKAGE/ SEEPAGE IN MD/OTM ACCN AT MIL STATION SUBATHU UNDER GE KASAULI.
Sl. No. Item Description
1Schedule 'A' Section - I
2Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar incl all quoins, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles etc complete all as specified and directed.
3Material and labour for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radious built in CM 1:6 etc complete all as specified and directed.
4Same as above but except bricks all as specified.
5Material and labour for Brick work with sub class 'B' bricks straight or curved on plan in any radius in half brick thick wall built in CM (1:4) incl demolition etc complete all as specified and directed.
6Demolition of Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed.
7Material and labour for 15 mm thick rendering in cement mortar 1:4 in side and out side wall of manhole of brick work/concrete surfaces finished even and smooth ( With out using extra cement) complete all as specified and directed.
8Material and labour for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth with out using extra cement (Internal surfaces) and taking down old plaster, complete all as specified and directed by Engr-In- Charge.
9Material and labour for taking down cement or cement lime plaster from brick or stone walls etc incl. racking out joints, hacking for keys, scrubbing down with water etc and providing 15 mm thick rendering with cement mortar 1 : 4 finished even and smooth (without using extra cement) complete all as specified and directed.
10Material and labour for non skid joint free coloured ceramic tiles 7-8 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15 mm thick screed bed in CM 1:6 including Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
11Material and labour for joint free coloured glazed ceramic tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4 including Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
12Supply and fixing in repair 15 MM bore concealed stop valves long shank and cup cast copper allow chromium plated fancy type screwed down high pressure, with capstan handle long shank screwed both ends all as specified.
13Material and labour for 500 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl 20mm PTMT ball valve hoisted and fixed in position all as specified in SSR Part I. and Dismantling of water tanks 500 ltrs of capacity and removing to store complete all as specified and directed.
14Supply and fixing for 15mm Fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
15Supply and fixing in repairs brass chromium plated bib tap (short body) for iron pipe of 15 mm bore fancy type with crutch or butterfly handle, screwed down high pressure complete all as specified and directed.
16Supply and fixing in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, Aluminium brackets for bottom support fixing with gitties embedded in wall with drilling machine etc complete all as specified and directed
17Supply and fixing in repairs stop/ Angle cock ISI marked fancy type, chromium plated, screw down high pressure with crutch or butterfly handle screwed both ends suitable for iron pipe of 15 mm bore complete all as specified and directed.
18Supply and fixing in repairs vitreous china wash hand basin, white flat back size 550x400mm including porcelain stopper and a pair of MS bracket etc complete all as specified.
19Material and labour for PVC floor trap ,plain with grating including jointing to waste pipe with solvent cement dia of outlet 75mm in repairs all as specified and directed.
20Supply and fixing in repairs CP brass shower rose 125mm size shower with 300mm arm suitable for 15mm bore pipe complete all as specified.
21Supply and fixing in repairs PVC connection 600 mm long with 2 Nos brass check nuts suitable for 15 mm bore of pipe with washer complete all as specified and directed.
22Supply and fixing for Waste fittings of PTMT full threaded 32 mm, in repair.all as specified and directed.
23Demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) etc complete all as specified and directed
24Material and labour for PCC 1:4:8 type D-2 as in foundation, sub base of floor and mass concrete using 40 mm graded stone aggregate complete all as specified and directed.
25Material and labour for rendering 20 mm thick cement plaster in CM (1:3) finished even and smooth w/o using extra cement and using waterproofing compound on fair faces of brick work or concrete surfaces complete all as specified and directed.NOTE: WPC will be measured and paid for separately.)
26Material and labour for applying water proofing treatment to sunken slab comprising of the following specifications complete all as specified. (i) Cleaning of roof surface with mechanical means i.e. wire brush/air blower etc. and remove all loose /unsound material,dirt,dust etc.(ii) Providing and laying water proofing treatment of sunken portion of WCs, bathroom etc by applying cement slurry mixed with acrylic based polymer modified cementitous composit compound coating of make as approved in Technical Instruction 5/2003(iii) First layer of cement slurry @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm of approved make and allowed layer to air cure for 04 hours.(iv) Second layer of cement slurry @ 0.244 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.126 Kg/Sqm and allowed layer to air cure for 04 hours followed with water curing for 48 hrs .(v) 200 micron thick polythene film pasted with the hepl of adhesive shall be provided over treatment .
27Material and labour for Bituminous water proofing treatment by applying bitumen coat @ 3.00 Kg per Sqm for receiving APP Membrane complete all as directed by Engr-in-Charge
28Material and labour for laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not lessthan150gms/sqm) landonprimedsurface by forced application complete all as specified
29Material and labour for 75 mm thick Cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate) as in plinth protection/ path incl finishing the surface even and smooth w/o using extra cement all as specified and directed.
30Supply and fixing in repair 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as rain water pipe and similar work including taking down old existing pipe complete all as specified.
31Supply and fixing in repair 110mm PVC (SWR) bends any radius complete all as specified and directed.
32Supply and fixing in repairs PVC (SWR) pipes single socketed (ISI Mark) in any length with rubber ring joints fixed to wall (75 mm bore) including taking down complete all as specified and directed.
33Supply and fixing in repairs PVC (SWR) bends / elbow 75 mm (ISI Mark) complete all as specified and directed.
34Material and labour for GI tubing ISI marked medium grade 15 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor including connection etc, incl cutting chasing in wall for concealing of pipe if required and including taking down complete all as specified complete all as specified and directed.
35Material and labour for GI tubing ISI marked medium grade 20mm bore with all fittings and fixed complete to walls and ceiling or laid under floor including connection etc, complete all as specified incl taking down complete all as specified and directed.
36Refixing old steel 15mm dia steel tubing and connections in new or old position (Walls, ceiling floors, etc) and including Taking up or down 15mm dia steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
37Refixing old steel 20mm dia steel tubing and connections in new or old position (Walls, ceiling floors, etc) and including Taking up or down 20mm dia steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
38Cutting chases, pinning in brick wall , making good to facing where required and pointing in CM 1:3 to ends or edges of slabs and making good cutting exc. 10 cm but n.exc 20 cm girth. Etc complete all as specified and directed
39Material and labour for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement including removing of existing roof treatment with following:-(a) Material and labour for preparation of surface by removal of existing treatment of tarfelt including mud phuska and taking down plaster to ensure or clean smooth and dry surface.(b) Providing and laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Itr/sqm on dry and clean surface.(c) Material and labour for providing and laying APP based polymeric membrance of 3 mm thinkness of weight of 150 gm / sqm with non woven polyster mat as reinforcement on primed surface by torch application with side laps & joints over laps etc as per manufacturer instruction.(d) Material and labour for applying a coat of blown bitumen grade 85/25 @ 1.20 Kg/Sqm on top of APP memberane and finally finishing the top surface by applying a coat of aluminium paint as per manufacturer's instructions. Make : STP Ltd/Dr Fixit or equivalent make.Note:- (i) All the water proofing treatment works shall be got carried out through authorised applicator of the firm. In this regard prior written approval from GE shall be obtained.
40Supply only liquid water proofing compound of approved quality complete all as specified and directed.
41Material and labour for plastering on wall or on floor 15mm thick in CM 1 : 4 mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed.Note :- WPC shall be measured and paid separately.
42Disconnecting existing water tanks exc 250 lts n.exc 500 ltrs capacity ,setting aside (or lowering if required) for repair,cleaning etc and hoisting if required reconnecting and refixing in position (cleaning, repairing etc measured separately) complete all as directed.
43Disconnecting existing water tanks exc 500 lts n.exc 1000 ltrs capacity ,setting aside (or lowering if required ) for repair, cleaning etc and hoisting if required reconnecting and refixing in position (cleaning, repairing etc measured separately) complete all as directed.
44Cleaning and removing all scale and dirt, etc, from water storage tanks 500 Ltr capacity existing tanks and from mouths of circulating pipes, etc complete all as specified and directed.
45Cleaning and removing all scale and dirt, etc, from water storage tanks 1000 Ltr capacity existing tanks and from mouths of circulating pipes, etc complete all as specified and directed.
46Supply and fixing in repair Ball valves 15mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms) including taking down old one complete all as specified and directed.
47Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
48Supply and fix 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275. if fixed with L-type or J-type or cranked hook bolts in lieu of screws complete all as specified and directed.
49Supply and fix 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
50Supply and fixing for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
51Supply and fixing for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
52Supply and fixing for Mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') purlin, rafter all as per specified and directed .
53Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
54Laying of waterproofing membrane: Providing and laying 1.5mm thk Proofex Org, a loosely laid reinforced TPO membrane on the well cleaned and undulation free surface. The TPO membrane individual roll shall be laid over 300GSM, geotextile laid over the prepaired surface. All additional membranes shall then be laid with its overlaps of 50mm fixed using hot air welding machine. In case of mechanically fixed TPO membrane, the side overlaps shall be minimum 100mm. Entire terrace area shall then be covered using Proofex Org in a similar manner. Item includes termination, sealing of earthing post and other ancilliaries proposed as per fosroc's methodology. The termination details shall be discussed at site , once before membrane fixing. Termination and membrane laying shall be done as per fosroc's approved methodology.
55Contd... Srl Item No. 53.00:-The waterproofing TPO membrane shall be BBA certified and shall have:1. Tensile strength (ASTM D412)Longitudinal : > 10N/mm2Transversal : > 10N/mm22. Elongation at break (ASTM D412 and EN 12311-2)Longitudinal : >900%Transversal : >750%3. Puncture resistance : Pass test > 800mm (EN 12691 dynamic)4. Water impermeability : Pass test (EN 1298)5. Water impermeability : Passout (EN 12691 dynamic)6. Water vapour transmission : Nil (ASTM 96)7. Tear resistance (EN 12310-1) Longitudinal : 530 N Transversal: 1.5mm - 600 N8. Root resistance : Pass test - no penetration9. Lap joint strength : Pass test-broken out joint (EN 12317 and UEATc), Duarability : Pass test 2500hrs -ResistanceUV(EN1297) no crack10. Hail resistance : >26m/s (EN 13583)
56Supply and fixing for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks stagging and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
57Demolition Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
58Material and labour for providing PCC (1:2:4) type B0 (using 12.5mm graded stone agg) as in roof kerbs and mud stope rounded or chamfered on edges complete all as directed.
59Material and labour for 40mm thick brick tiles bedded 15mm thick in cement mortar (1:6) and joints grouted flush in Cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as directed.
60Material and labour for laying 8mm thick HDF (High Density Fibreboard) direct pressure laminated flooring with abrasion resistance of Class 33/AC-5 conforming to EN13329, density 900 kg/m3, overlay paper of 65 GSM consisting of aluminium oxide coated tissue, Flame resistance CFL-S1 conforming to EN13501 of approved colour/ shade/ texture with wax sealed locking (tongue and groove interlocking) with necessary backing materials required as per manufacturer instructions and laid on existing wooden planks flooring/ PCC flooring complete all as specified and directedNote : Work shall be done by authorised applicator of the manufacturer.
61Providing and applying self-adhesive waterproofing membrane, 1.5 mm thick, comprising a high-performance bituminous/polymer modified membrane with a reinforced carrier film and peel-off release liner, specifically designed to arrest leakage and seepage through laps, joints, screw fixings, penetrations, and localized defects in pre-engineered galvanized roofing sheets. The membrane shall possess excellent adhesion to galvanized steel surfaces, be UV and weather resistant, flexible, and capable of accommodating thermal movement without cracking or delamination. The work shall include thorough surface preparation by cleaning and drying the substrate, application of primer wherever recommended by the manufacturer, cutting, positioning, and firmly rolling the membrane to achieve full adhesion without air pockets, with minimum 50 mm side and end overlaps, complete sealing of all joints, edges, and penetrations, and all labour, materials, tools, equipment, scaffolding, wastage, and incidental works required to complete the waterproofing treatment in accordance with the manufacturer's specifications and as directed by the Engineer-in-Charge.
62Supply and fixing for Elephant shield liquid rubber for long lasting ready to use wateroroofing for sheet joints & bolt holes, gutter joint, roof & wall crack, solar panel, cut out, damp wall all as specified and manufacturer's specifications and as directed by the Engineer-in-Charge.
63Supply and fixing for Hasthip anti - birds spike strips, pigeon spike 50cm long stainless steel spike strips with 2 cable ties, dual row spike design, anti-animal or anti-climb deterrent spike for birds, cat etc all as specified and manufacturer's specifications and as directed by the Engineer-in-Charge.
64Supply and fixing for plastic water tank cover lid, available in size 17 inch and 18 inch inner diameter monkey protector nail on the lid surface all as specified and manufacturer's specifications and as directed by the Engineer-in-Charge.
65Material and labour for Providing and fixing tiled false ceiling of designer tiles(high pressure steam Cured) of 4mm thickness (as per IS:14862) of size 595x595mm and any one of the design ( Cascade or Electra or equivalent) in true horizontal level, suspended on inner locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grms, both side inclusive and black painted groove on all T webs) consisting of main “T” runner with suitably spaced joints to get required length and 15x32mm made from 0.3mm thick sheet, 1200mm long spaced between main “T” at 600mm C/C to form a grid of 1200x600mm and secondly cross “T” of length 600mm and size 15x32mm made of 0.30mm thick sheet to be interlocked at middle of 1200x600mm panel to form grids of 600x600mm and wall angle 15x20x0.36mm and laying false ceiling tiles in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanized butterfly level clips, spaced at 1200mm c/c along main “T”, bottom exposed width of 15mm of all “T” sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5 mm width, and Dismantling wall and ceiling board (fibre, pulp , insulation etc) or insulation boards/ slabs any thickness all complete at all heights as per directions of Engineer-in-Charge.
66Amount of credit of Rs. 318954.80 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57631373
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Leakage/ Seepage In Md/Otm Accn At Mil Station Subathu Under Ge Kasauli.
Basic Detail
Tender No GEK-60/2026-27
Bidding Type Tender
Location
City Solan
State Himachal Pradesh
Key Dates
Publish Date 22 Sep 2026
Submission Date 12 Oct 2026
Open Date 14 Oct 2026
Finance
Tender Value 48 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
BOQ_886142.xls
fba2259b-a0d2-4aab-947f-8559a7469897.html
Tender602627.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_886142.xls

html

fba2259b-a0d2-4aab-947f-8559a7469897.html

pdf

Tender602627.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender