Housing Urban and Rular Development Government Departments Closing in 10 days TDR #57631021

Tender For Construction Of Additional Class Room And Boundary Wall At Jyoti Vikash Degree College, Bhainsa Under Deposit Fund

Issued by Government Departments · Balangir, Odisha
Tender Value
45.84 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
10 days left
EMD
45900
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Additional Class Room And Boundary Wall At Jyoti Vikash Degree College, Bhainsa Under Deposit Fund

BOQ

Name of Work:- Construction of Additional Class Room and Boundary Wall at Jyoti Vikash Degree College, Bhainsa under Deposit fund
Sl. No. Item Description
1CIVIL PORTION OF WORK:-Earth work in excavation in hard soil with all leads and lifts including rough dressing and levelling bed and depositing the excavated materials away from the working site as directed by the Eigineer-in-charge.(A) Additional Class Room
2(B) Boundary Wall
3Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not Exceeding 23 cm .in depth with all lead and lift including cost, Conveyance, Loading, unloading, Royalties and taxes of all materials, cost of all labour. labour cess, sundries, T&P required for work etc .complete in all respect as per direction by the Engineer in charge.(A) Additional Class Room
4(B) Boundary Wall
5Cement Concrete of prop.(1:3:6) in foundation up to lowest bed level using crusher broken hard black granite metal of size 4cm down graded of approved quality from approved quarry as per approved design including hosting, lowering, laying compacting concrete in layers not exceeding 6\\"thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty & taxes of all materials, with labour T&P required for the work etc. complete in all respects including dewatering if required as per direction of engineer-in -charge.(A) Additional Class Room
6(B) Boundary Wall
7First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. (with dimensional tolerance of +85%) having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement (PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.(A) Additional Class Room
8(B) Boundary Wall
9Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.(A) Boundary Pillar
10(B) Boundary Wall
11Providing lifting, hoisting and laying R.C.C. of M-20 Grade with 20mm and down grade C.B. chips to base of columns and footing, columns, beams, plinth band, lintels, chajja, shaft, fins, roof slabs, balconies, stair cases, parapets, window sills, lofts, railing, jally, copping or in places as shown in the drawing for all floors with 20mm and down graded size black hard crusher broken ships of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth (if required providing plaster with cement mortar (1:4) wherever necessary without any extra cost) including rigid smooth centering and shuttering, scafolding, watering (excluding reinforcement bars) and curing for required period including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge.(A) Additional Class Room(i) RCC Roof Slab
12(ii) Column base & footimng
13(iii) Column in Super Structure
14(iv) Wall Beam
15(v) RCC Lintel
16(vi) RCC Plinth Band
17(vii) RCC Chajja
18(B) Boundary Wall(i) Column base & footimng
19(ii) Plinth Beam
20(iii) Column in Super Structure
21(iv) Coping
22Supplying, cutting, straightening of steel HYSD (Fe- 415) conforming to (IS- 1786) with bending, binding, cranking, hooking, welding or jointing if necessary & tying the grills and placing in position as required for the Rod work in all floors and & for providing fan hooks hosting lowering & laying steels including cost conveyance, taxes & royalties of all materials and binding wires of 18 to 20 gauge & cost of all labour T&P required for the work etc. Complete in all respect as per the direction of Engineer in charges (payment will be made on weight of MS rod or tor steel only basing on the co- efficient of MS rod or tor steel bars approved by SAIL / TATA / competent authority and (No separate payment will be made towards the cost of binding wires over lapping, wastage, coupling, welded, joints , spacer bars, chairs stays, hangers and annealed steel wires or other methods for binding and placing etc.).(A) Additional Class Room
23(B) Boundary Wall
24Providing 12 mm thick cement plaster (1:6) (1 cement : 6 sand) to outside plastered surface / plumped surface of masonar, racking out joints, cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing as shown in the drawing including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalities, scaffolding, watering, curring, sundries, tools and plans etc complete as per direction of E.I.C.(A) Additional Class Room
25(B) Boundary Wall
26Primering one coat with any approved shade of primer of approved make over the plastered surface of walls including cost, conveyance and taxes of all labour with T&P required for the work etc. complete as directed by the Engineer-in-charge. (A) Additional Class Room
27Wall painting two coats with plastic emulsion paints of approved shade on new work by means of brush including watering and curing etc. complete including cost of paint with taxes and cost of all labour with T & P required for the work etc. complete.(A) Additional Class Room
2825mm thick grading concrete (1:2:2) on roof slab with 6.7 mm size hard granite on new work after chipping and chiselling the same and cleaning the surface by wire brushes watering and curring etc. complete including cost, conveyance, royalties and taxes of all materials and labour with T&P required for the work etc. complete in all respect.(A) Additional Class Room
29Supplying, fitting and fixing Vitrified tile in floors of approved make conformaing to IS:13755 laid on 25 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C. (A) Additional Class Room
30Supplying of M.S. Grill Gate, Door, Window Chowkath with Shutter made out of M.S. Angle and G.R. sheet etc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete(A) Additional Class Room(i) Door
31(ii) Window
32(B) Boundary Wall
33Painting three coats in all floors (Two coats with paints of approved shade and base coat with primer) to new wood/iron work including sand papering, polishing the surface including cost conveyance taxes and royalties of all materials and with T & P required for the work including cost of paints and primer complete in all respect as per direction of Engg-in-charge. (A) Additional Class Room
34Wall painting two coats with weather coat of approved shade on new work by means of brush including watering and curing etc. complete including cost of paint with taxes and cost of all labour with T & P required for the work etc. complete.(A) Additional Class Room
35(B) Boundary Wall
366 mm thick C.P. (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment , watering, curing cost, carriage & royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C.(A) Boundary Wall
3716mm (5/8\\") thick cement plaster (1:6) in finishing smooth to inside rough surface of 10\\" thick brick walls after racking out the joints including watering and curring, with cost conveyance royalty and cost of all labour T & P required for the work etc. complete.(A) Additional Class Room
38(B) Boundary Wall
39Providing enamel painting two coat over a coat of primer with any approved enamel paint on New wood / iron work after cleaning the surface, sand paparing etc. complete as directed by the Engineer-in-charge using paint including cost and conveyance taxes of all materials including cost of paint with taxes and cost of all labour with T&P required for the work etc. complete in all respect.(A) Boundary Wall
40EI PORTION OF WORK:A) Sub-Head I (modular Wiring Items)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells / Polycab / Finolex / RR Kable) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit (Make-AKG / Polycab / precision / norpack / sudhakar) with 6A modular type switch (Make-Legrand (Myrius), Schneider (Zencelo), Panasonic (Vision) ISI marked, and ceiling rose ISI marked of modular type G.I box with cover, of suitable size, modular box with 1.5 sq. mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection. Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point.GROUP-A
41GROUP-B
42GROUP-C
43Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) (Make-Legrand (Myrius), Schneider (Zencelo), Panasonic (Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge.
44Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket (modular type) (Make-Legrand (Myrius), Schneider (Zencelo), Panasonic (Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.
45Supplying, fixing of 3 x 6A + 1 x 16A Plug on the separate board with complete fitting by 01 no of 16A + 3 nos 6A switch & socket (modular type) (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side) (anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of Engg-in-charge. Make-Schneider (Zencelo) / legrand (Myrius-NEXT GEN) / Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
46Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG / BEC / Precision / Norpak / Anchor / Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5)
47Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG / BEC / Precision / Norpak / Anchor / Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
48Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG / BEC / Precision / Norpak / Anchor / Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (2X6+1X2.5) (ICTDP Main switch to DB)
49Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG / BEC / Precision / Norpak / Anchor / Kinjal as required as per direction of Engg.-in-Charge. 1 nos single core 2.5 sq. mm copper wire for phase in existing conduit (invertor point)
50S/F of Bakelite angle holder/batten holder (make - Anchor / Havells of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .
519 Watt Bulb (Philips/ Crompton/ Havells)
52B) Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Technix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years .
53S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge. (Make - Schneider (Zencelo) / legrand (Myrius) / Panasonic (vision)
54S/F of Street light- 45W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover (Make: Panasonic / LT / Havells / Philips / Wipro / Crompton / Bajaj) (5Years Warranty).
55C) BDBS, DB, AC DB, FLOOR PANELS, MCBSSupply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years. (For AC DB)
56Supply and fixing of 4 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years. (For AC DB)
57S/F of 63A ICDP Main Switch with enclosure box of Havells/Anchor/Legrand/L&T/Equivalent make. Including all coneections and accessories as required.
58Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, 10KA breaking capacity, single poles MCB of Make - LEGRAND - DX3 / Siemens - Betaguard / Schneider - Acti 9/ABB SB 200 Model of ABB / LK / Hager / C&S / Havells / Panasonic the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 year.
59Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, DOUBLE POLE MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Model in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. (For AC)
60D) (Earthing) INSTALLATIONSupplying,installation,testing & commissioning of Standard earthing with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
61Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57631021
AUTHORITY Government Departments
TENDER VALUE 45.84 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Construction Of Additional Class Room And Boundary Wall At Jyoti Vikash Degree College, Bhainsa Under Deposit Fund
Basic Detail
Tender No 03/KBJ/2026-2027
Bidding Type Tender
Location
City Balangir
State Odisha
Key Dates
Publish Date 21 Sep 2026
Submission Date 03 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 45.84 Lakhs
Tender Fee 6000
EMD 45900
Exemption Available
Document List
BOQ_610211.xls
f46c8a01-4304-48bb-9887-c029c1a8a76e.html
Tendernotice_1 (20).pdf
Tendernotice_2.pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_610211.xls

html

f46c8a01-4304-48bb-9887-c029c1a8a76e.html

pdf

Tendernotice_1 (20).pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail