Housing Urban and Rular Development Government Departments Closing in 2 days TDR #57628651

Tender For Rewiring And Renewal Of Fittings, Fans, Street Lights And Powermains To The Health Sub Center At Elamanam In Trichy District

Issued by Government Departments · Tiruchirappalli, Tamil Nadu
Tender Value
2.96 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
2 days left
EMD
3000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tiruchirappalli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Rewiring And Renewal Of Fittings, Fans, Street Lights And Powermains To The Health Sub Center At Elamanam In Trichy District

BOQ

Name of Work:- Rewiring and Renewal of fittings, fans, street lights and powermains to the Health Sub Center at Elamanam in Trichy District
Sl. No. Item Description
1Rewiring with 2x1.5sq.mm. PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light/fan point(for electronic regulator)(5 points per coil)
2Rewiring with 2x1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (6 points per coil)
3Renewal by Supply and fixing of 4Feet LED 20W Fitting with LED 20W tube (HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting.
4Renewal by Supply and fixing of fancy glass shade and 7W / 9W LED bulb.
5Renewal by Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32 mm dia. GI pipe (class B) with 1 no. 32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting.
6Renewal by Supply and fixing of LED Flood light 150W with Integrated Driver (Higher End) complete with MS angle with PVC unsheathed Copper leads from terminals to the fitting.
7Renewal by Supply and fixing of 1200mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp.
8Renewal by Supply and fixing of 5A / 15 A 3 Pin combined flush type wall socket with 15A flush type switch concealed in suitable TW box of size 8\\" X 6\\" X 3\\" in flush with wall and covered with 3 mm thick hylum sheet with painting.
9Renewal by Supply and fixing of 3Nos. 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket)
10Renewal by Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour.
11Renewal by Supply and fixing of 32 A DP MCB in 2 way sheet steel enclosure in flush with wall and making good of the concealed portion and earth connection. (Higher end)
12Renewal by Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
13Renewal by Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour.
14Renewal by Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 MA Double Pole RCD / RCCB (Higher End) with suitable necessary connection.
15Renewal by Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains.
16Renewal by Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains.
17Renewal by Supply and erection, testing, commissioning uninterrupted power supply OFFLINE (sinewave) with copper wound transformer of 2000VA with input supply of 230V, 50Hz AC supply with 150AH Tubular battery to work at full load capacity including transportation with following specification. 1.Input voltage: 230, 50Hz single phase AC Supply2.Output voltage: 220V to 240V 50Hz AC Supply3.Battery charging device of suitable rating4.Circuit board of suitable capacity5.Over load and short circuit protection6.Visual Indication for ON/OFF/Trip/battery charging/mains failure/low battery etc.,7.Mode setting for By pass/Reset8.12V 150AH battery - 2 Nos.9.Trolly for heavy UPS & Battery(make: Exide/Microteck/Amron/Equivalent)
18Renewal by Supply and fixing of Automatic Electrical Water Heater with copper container, with Glass wool/Puf insulation with MS powder coated shell suitable for 25 litres capacity 230V/1000w 50 c/s AC supply (Venus/Racold) on suitable MS clamps with 3 core flex wire, but without plumping work.
19Renewal of Earthing as per PWD standard with an earth electrode of 2metre Class'B' GI pipe of dia not less than 32mm complete with necessary masonry work.
20Renewal by Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
21GST @ 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57628651
AUTHORITY Government Departments
TENDER VALUE 2.96 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Rewiring And Renewal Of Fittings, Fans, Street Lights And Powermains To The Health Sub Center At Elamanam In Trichy District
Basic Detail
Tender No TN.No. 3 2026-27 Dt 17.09.2026
Bidding Type Tender
Location
City Tiruchirappalli
State Tamil Nadu
Key Dates
Publish Date 21 Sep 2026
Submission Date 05 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 2.96 Lakhs
Tender Fee Ref. Documents
EMD 3000
Exemption Not Available
Document List
BOQ_849227.xls
d2b3a0d0-f70e-40d6-87e6-f9b7cdf4a0cc.html
Elamanam.pdf
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_849227.xls

html

d2b3a0d0-f70e-40d6-87e6-f9b7cdf4a0cc.html

pdf

Elamanam.pdf

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders