BOQ
| Sl. No. | Item Description |
| 1 | Renewal by Supply, Erection, testing and Commissioning of 1.5 TR (6000 K.cal/hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Non CFL compressor operating on refrigerant suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with three Star rating as per BEE specification Five Star Rated and capable of performing the following functions.(A) Cooling (B) Dehumidifing (C) Air Circulating (D) Filtering. The installation work for the above split type AC units includes the following. 1. Mounting / fixing indoor and outdoor units at their respective locations.2. Laying refrigerent pipe line of 6 mtrs. Length, both units after drilling hole/holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. 3. Installing the suction pipe with expanded polyurthelene foam 5mm thick tubing.4. Laying 25mm dia flexible PVC drain pipe of 6mtrs. Length to drawn out the condensate water being formed in the indoor unit.5. Leakage testing the entire gas unit.6. Charging refrigerant gas in the unit.7. Suitable electric wiring to be provided 3 core with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units upto 4 mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (Make : Carrier/Voltas/Blue Star make only) |
| 2 | Renewal by Supply, Erection, testing and Commissioning of 2.0 TR (6000 K.cal/hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Non CFL compressor operating on refrigerant suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with three Star rating as per BEE specification Five Star Rated and capable of performing the following functions.(A) Cooling (B) Dehumidifing (C) Air Circulating (D) Filtering. The installation work for the above split type AC units includes the following. 1. Mounting / fixing indoor and outdoor units at their respective locations.2. Laying refrigerent pipe line of 6 mtrs. Length, both units after drilling hole/holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. 3. Installing the suction pipe with expanded polyurthelene foam 5mm thick tubing.4. Laying 25mm dia flexible PVC drain pipe of 6mtrs. Length to drawn out the condensate water being formed in the indoor unit.5. Leakage testing the entire gas unit.6. Charging refrigerant gas in the unit.7. Suitable electric wiring to be provided 3 core with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units upto 4 mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (Make : Carrier/Voltas/Blue Star make only) |
| 3 | Renewal by supply and erection of 5 KVA electronic automatic Voltage stabilizer with input range of 170V-270V and output range of 200-240V with high/low cut off 3 minutes time delay relay with demonstration suitable for operation on 230V/50Hz single phase AC supply. (V-Guard/Syscom/Equivalent) |
| 4 | Renewal by supply and erection of 4 KVA electronic automatic Voltage stabilizer with input range of 170V-270V and output range of 200-240V with high/low cut off 3 minutes time delay relay with demonstration suitable for operation on 230V/50Hz single phase AC supply. (V-Guard/Syscom/Equivalent) |
| 5 | Renewal by supply and fixing of MS stand for fixing outdoor unit. |
| 6 | Renewal by supply and laying of 5/8\\" and 3/8\\" copper pipe. |
| 7 | Renewal by Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) |
| 8 | Rewiring with 2x1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (5 points per coil) |
| 9 | Renewal by supply and fixing of 1x1 18W LED surface mounted Luminaries fitting with PVC unsheathed copper leads from terminal to the fitting with necessary connection. |
| 10 | Renewal by Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. |
| 11 | Renewal by Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 12 | Less credit |
| 13 | GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender