Tender For Construction Of Boundrywall And Guard Room Of Kasturba Gandhi Balika Vidyalaya At Tanda And Construction Of Guard Room At Bheeti District-Ambedkar Nagar.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Oct 2026
11 days left
EMD
1.12 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ambedkar Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Boundrywall And Guard Room Of Kasturba Gandhi Balika Vidyalaya At Tanda And Construction Of Guard Room At Bheeti District-Ambedkar Nagar.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. |
| 2 | Providing and laying in cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). excluding the cost of centering and shuttering . |
| 3 | Providing and laying in position specfied grade of reinforcement cement concrete, excluding the cost of centering,shuttering,finishing & reinforcement. All work up to plinth level.1:1.5:3 (1 cement,1.5 coarse sand zone-iii,3 graded stone aggregate 20mm. (Nominal size) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : in 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in an over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 7 | Brick work with common burnt clay (non-modular) bricks of class-150 in foundation & plinth in. Cement morter 1:6 (1cement:6 coarse sand) |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-15 in superstructure above plinth level up to floor V level in all shapes and sizes in : cement mortor 1:6 |
| 9 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation M-15 in superstructure above plinth level up to floor V level. |
| 10 | External Plastering 15mm thick plaster with cement mortar in proportion of 1:6 cement & coarse sand of 1.5-2.00 FM for external walls |
| 11 | 12 mm th. cement plaster inner surface |
| 12 | Finishing walls with water proofing cement paint of required shade |
| 13 | Colour washing such as green, blue or buff to give an even shade :New work (two or more coats) with a base coat of white washingwith lime |
| 14 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40MM THICK WITH 20 MM NOMINAL AGGREGATE |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 16 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete 250x10 mm |
| 17 | Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm |
| 18 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. 250X16 MM |
| 19 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 21 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 22 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 4 mm thick glass panes |
| 23 | Centering and shuttering including strutting, propping etc. and removal ofform for :Foundations, footings, bases of columns, etc. for mass concrete |
| 24 | Suspended floors, roofs, landings, balconies and access platform |
| 25 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 26 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 27 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 28 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 29 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 30 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. |
| 31 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.a) 32mm dia |
| 32 | Supply and fixing of UPVC SWR Pipe type B conforming to IS-13592n including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar conforming to IS -14735. Also including excavation of trenches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, Tee and Y-Tee including supply of all ,material labour and T&P required for proper completion of work.a) 110mm dia OD. |
| 33 | b) 90mm dia OD. |
| 34 | Supply and fixing of UPVC SWR Nahani trap size 100/75, 110/90mm conforming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty C.P. brass jali. |
| 35 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm diameter |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(internal work)Exposed on walla) 25mm dia nominal bore |
| 37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.Concealed work, including cutting chases and making good the walls etc.b) 20mm dia nominal bore |
| 38 | b) 25mm dia nominal bore |
| 39 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.a) 15mm nominal bore |
| 40 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore |
| 41 | Providing and fixing gun metal gate valve with wheel of approved quality.b) 25mm dia nominal bore |
| 42 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W.R Pipes including bed concrete as per standard design.110mm diameter S.W.R. Pipe a) 110mm diameter S.W.R. Pipe |
| 43 | Providing and fixing UPVC S.W.R. Gully trap conforming to IS 14735 size 150x110 mm dia of self cleaning design including fixed with brick massonary chamber 250 x 250 x 250mm size I/C supply and fixing of C.I. cover with frame weight not less than 4.5 kg and C.I. grating 150x150mm coplete in all respect. |
| 44 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 45 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. GROUP-B |
| 46 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 47 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 48 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA) C Curve 5 - 32 amps.Cat. A |
| 49 | Supply and fixing of 40/63 Amp MCCB(10KA)C Curve 40 Amp. 4 Pole MCB Cat. A |
| 50 | Supply and erection of AC 1200 mm Sweep, 230/250 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required |
| 51 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 52 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (Butwithout MCB/RCCB/Isolator) 4 way double door |
| 53 | Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect |
| 54 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum powerconsumption should not more than the specified rating and Fixture shallbe confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. System lumen efficacy ≥105and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for alltesting required for LED fixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LEDjunction temperature shall not rise above 90°C)8-10 WATT Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender