Tender For Improvement To Bldg No.82 At Afs Bidar
Tender Value
43.50 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
16 days left
EMD
87000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bidar → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Improvement To Bldg No.82 At Afs Bidar
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm depth and average 15 cm deep in hard/dense soil, complete all as specified and as directed. |
| 2 | Excavation in post holes (or similar holes) in hard/dense soil each n exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exceeding 50m and making good surface, complete all as specified and as directed. |
| 3 | Material & Labour For Plain cement concrete type D-2, 1:4:8 ( 40 mm graded aggregate) in foundation, filling and mass concrete, complete all as specified and as directed. |
| 4 | M&L thick Plain cement concrete Type B-2, 1:2:4 (40 mm graded aggregate) in foundation, filling and mass concrete, complete all as specified and directed. |
| 5 | Material and labour, for Pre-cast cement concrete block masonry with grade ‘C’ solid blocks not exceeding 10 cm in width, having minimum compressive strength of 50 Kg / Sq cm as per IS 2185 (Part- I) 2005 and set in CM 1:6 complete all as specified and as directed. |
| 6 | S&F MS Roof trusses (framed),Vertical post, trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Square or Rectangular hollow sections) including distance pieces, cleats, screw bolt with washers and one hexagonal or square nuts etc. conforming to Fe-290 Gde-165 , complete all as specified and as directed. |
| 7 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing conforming to Fe-290 (Grade E 165), complete all as specified and as directed. |
| 8 | S&F Mild steel in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and as directed. |
| 9 | S&F Pre Painted Galvanized aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, in plane or curved shape, fixed with self tapping screws as specified, complete all as specified and as directed. |
| 10 | S&F, Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, rain water gutter / cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 11 | M&L Preparation of New or previously untreated steel surface or any description, over 10cm in width or girth, not otherwise described and applied two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 12 | M&L Preparation of New or previously untreated steel surface or any description n exc10cm in width or girth, when unconnected with other painting or when painted in a different tint and applied two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 13 | Supply and fix in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc, complete all as specified and as directed. |
| 14 | Supply and fix in repairs PVC (SWR) bends 110mm dia any radius with access door, complete all as specified and as directed. |
| 15 | Supply and fix in repairs PVC (SWR) bends 75 mm dia any radius with access door, complete all as specified and as directed. |
| 16 | Supply and fix in repairs PVC (SWR) junction single,(Single T) 75mm dia equal or unequal with access door, complete all as specified and as directed. |
| 17 | M&L for sand or stone dust filling and sand or stone dust cushioning under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 18 | M&L for hard core of broken stone broken to gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 19 | Material & labour for Machine pressed precast concrete interlocking paver blocks/tiles, any shape & size with grey cement and pigment confirming to IS-15658-2006 of 60 mm thickness, M-35 grade complete all as specified and directed. (Note: Sand cushion measured and paid separately) |
| 20 | M&L 75mm thick for cement concrete type D-2, 1:4:8 20 mm graded aggregate as in sub base of floor and path, complete all as specified and as directed. |
| 21 | M&L for rendering 15mm thick in cm 1:4 on brick masonry surfaces or concrete surfaces on other than fair face of wall surfaces with sponge finish, complete all as specified and directed. |
| 22 | M&L preparation of newly plastered surfaces of work and applying two coats of oil bound distemper and over a coat of chalk whitening all as specified and directed. |
| 23 | Taking down chowkats or frames exceeding 1.5 sqm and not exceeding 4.0 sqm each but with shutters (without taking off shutters from the frame), complete all as specified and as directed. |
| 24 | Taking down chowkats or frames not exceeding 1.5 sqm each with shutters (without taking off shutters from the frame), complete all as specified and as directed. |
| 25 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets |
| 26 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for sub base for floor tiles, roof /chajja padding including removal of debris outside MD land, complete all as specified and as directed. |
| 27 | Dismantling floor, hearth or wall tiling including cement mortar bedding and removal of debris out of premises complete all as specified and directed. |
| 28 | Demolition of brickwork or stone/ PCC block masonry, built in cement mortar or cement lime mortar complete all as specified and directed. |
| 29 | Material and labour 25 mm thick plain cement concrete Type B-0, 1:2:4 (12.5 mm graded aggregate) as in sub base for floor tiles, complete all as specified and as directed. |
| 30 | Supply and Fixing Anodised aluminium window and ventilator shutters powder coating (minimum thickness of powder coating not less than 15 micron), side hung/sliding type without sash bars, aluminium sections weighing not exceeding 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws anodised aluminium fittings and locking with suitable metal body concealed lock of any colours complete all as specified and as directed. (Note :- 5 mm thick tinted or frosted glass and wire cloth shall be measured separately and cost of labour charges deemed to be included in unit rate.) |
| 31 | Supply and Fixing Anodised aluminium frame powder coating (minimum thickness of powder coating not less than 15 micron), side hung/sliding type for doors, windows, ventilators, partitions with one or more rebates including jointing cleat for fixing etc., complete all as specified and as directed. |
| 32 | S&F of UPVC ( Unplasticized Poly-Vinyl Chloride ) 3 Track 2 Panel sliding windows multichambered and stiffened / reinforced framed windows using 112mm x 52mm x 2.3mm (±0.2mm) size sections alround as main frames and shutters made with the profile sections of size 68mm x 42mm, including the cost and fixing of 5mm thick clear Toughened glass in shutters and SS Mesh in mesh shutters of size 60mm x 35mm with necessary beadings, the corners of all the profiles of frames and shutters shall be homogeneously fusion heat welded without any gaps. The shutters shall have touch lock and handles, beadings and other associated fittings to facilitate smooth operation. Both the Frame and the Shutters shall be Reinforced with GI Profiles of thickness 1.25mm. Fixing the window unit to the existing masonry with anchor fasteners as required. The gaps between the window frames and masonry walls shall be filled with silicon(Dowsil) or with any other suitable filler materials by the installation team at site. |
| 33 | Material and labour for MS framed work such as window grill, guard bar etc similar work confirming to Fe 290 Grade -E - 165 complete all as specified and as directed. |
| 34 | M&L, two coat of synthetic enamel paint over a coat of red oxide primer on new steel surfaces including preparation, of any description, n exceeding 10 cm width or girth. |
| 35 | Material and Labour for tinted glass 5 mm thick of any colours and glazing with oil putty or glazing clips etc in square or rectangular fixed with aluminium window/ ventilator shutters complete all as specified and as directed. |
| 36 | Supply and Fixing Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples/beads to Aluminium or Steel frame, complete all as specified and as directed. |
| 37 | Material & Labour for Vitrified Ceramic Light Shade tiles 7-8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set with spacer, joints of more than 3mm are grouted with epoxy grout including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 38 | Material & Labour for Vitrified Ceramic Light Shade tiles 10 mm thick (square/ rectangular) polished, in vertical surfaces such as skirting, dado etc. set with spacer, joints of more than 3mm are grouted with epoxy grout including 10mm thick rendering in CM 1:4 complete all as specified and as directed. |
| 39 | Supply & Fixing of 18- 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms including edge moulding, machine polish to edge as required and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and as directed. |
| 40 | Taking down cement plaster on bricks or stone walls etc., including raking out joints, hacking for key scrubbing down with water etc., complete all as specified and as directed. |
| 41 | Material and Labour Rendering 15mm thick on brick work or concrete surface in CM 1:4, complete all as specified and as directed. |
| 42 | Material and labour for Preparation of New plastered surface of wall and applying two coats of oil bound distemper over one coat of priming paint, complete all as specified and as directed |
| 43 | Material and labour for Complete removal of existing treatment and preparation of surface, applying primer coat on old surface of walls and applying two coats of distemper oil bound, complete all as specified and as directed. |
| 44 | Material & Labour for Applying 2mm thick wall care putty on wall or ceiling at any height etc, complete all as specified and as directed. |
| 45 | Material and Labour for Complete removal of existing treatment on Wall or newly plastered surface, Chajja, Roof Projection and Roof Fascia surface and Finishing surface with Acrylic exterior paint of required shade by mechanical sprayer(Two or more coat applied @ 1.67 litre/10 sqm over and including Two or more coat priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. |
| 46 | Material and labour for Complete removal of existing treatment of ceilings and applying two coats of oil bound distemper over one coat of alkali resistant priming paint, complete all as specified and as directed. |
| 47 | Material & Labour for Rendering 5mm thick on fair faces of concrete surface of ceiling in CM 1:3, surface finished even and smooth surface without using extra cement complete all as specified and as directed. |
| 48 | Material and labour for Preparation of new plastered surface on ceiling in height and any description and applying two coat of oil bound distemper over a alkali resistant priming coat, complete all as specified and as directed. |
| 49 | Material and labour for Preparation of Old painted surface of Steel of any description and applying one coat of synthetic enamel paint over 10cm width or girth complete all as specified and as directed. |
| 50 | Material & Labour Plain cement concrete 75mm thick Type C2 1:3:6 (40 mm graded aggregate) in Plinth Protection complete all as specified and as directed. |
| 51 | Supply and fixing of Anodized aluminium False Ceiling frame work with 605mm x 605mm size snap grid fixed with screws /staples at any height, complete all as specified and directed. |
| 52 | Supply and fixing of 12mm thick, Mineral fibre board/tiles of any size, fixed in ceiling at any height, flat or sloping, complete all as specified and as directed |
| 53 | Taking down/Removing of existing water proofing felt on roof surfaces and wall surfaces complete all as specified and as directed. |
| 54 | Taking down cement plaster on bricks or stone walls, cement concrete floor etc., including raking out joints, hacking for key scrubbing down with water etc., complete all as specified and as directed. |
| 55 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for roof /chajja padding including removal of debris outside MD land complete all as specified and as directed. |
| 56 | Material & Labour for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in Padding over roof / chajja complete all as specified and as directed. |
| 57 | Material & Labour for Rendering 15mm thick on brick work or concrete surface in CM 1:4 including WPC (WPC measured and paid separately) complete all as specified and as directed. |
| 58 | Supply only Liquid water proofing compound. |
| 59 | Material & Labour for Water proofing treatment on horizontal or vertical surfaces with Applying oil bound bitumen primer @ 0.20 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing 4.0 kg/sqm reinforced with non woven polyester matt weighing not less than 160 gm /sqm and applying a coat of blown grade hot bitumen 85/25 or 90/15 @ 1.20 kg/sqm and finished with solar reflective bituminous aluminium paint @ 100 grams/sqm complete all as specified and as directed. |
| 60 | Material & Labour for cutting grooves in brick work wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 61 | Supply and fixing of Rotational moulded polyethene Water storage tanks 1000 lit capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including dismantling of existing water tank, including 20mm Ball Valves, 20mm Tank nipple two nos connecting with inlet and outlet, 20mm bore Gun-metal, globe or gate valves, with iron wheel head, complete all as specified and as directed. |
| 62 | Excavation in trench not exc. 1.5m wide and not exc. 1.5m in depth and getting out in hard /dense soil for laying of cable trenches all as specified as directed. |
| 63 | Returning filling in , including spreading ,levelling , watering and well ramming in layer not exc.25 cm all as specified as directed. |
| 64 | Removal of surplus soil (excavated soil )to distance not exceeding 50m and depositing where directed at a level not exc.1.5m above the starting point and all as specified. |
| 65 | Supply and spread dust sand in trenches for cable cushioning all as specified as directed. |
| 66 | Supply and lay pre cast cable cover protection of UG cable of size 250 mm x 150 mm x 40 mm laid in trench as specified as directed. |
| 67 | Supply and lay cable XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured , electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size as 95 sqmm 3.5 core. |
| 68 | S&F GI pipe of 40mm Dia ,ISI marked ,light grade complete all as specified. |
| 69 | Material and labour for Point wiring for one light point/fan point/bell point controlled by one switch of 5 Amp (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing PVC conduit 20mm dia (medium duty, ISI marked) including provision of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. Complete all as specified and as directed. Note :Switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ). |
| 70 | All as per Serial item No 69 here-in-before, but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator |
| 71 | All as per Serial item No 69 here-in-before, but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 72 | All as per Serial item No 69 here-in-before, but for one 5 pin 5 Amps switch socket outlet point controlled by one switch on independent board |
| 73 | All as per Serial item No 69 here-in-before, but for one light point controlled by one, two way switch 5 Amps |
| 74 | All as per Serial item No 2 here-in-before, but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant Low smoke (FRLSH) PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly including 2mm thick galvanised steel pressed sunken box suitable for modular switch, socket (Min 60mm deep ,suitable length). |
| 75 | Supply and fix Modular Switch , one way 6 amps, 230 volts, 1 module complete all as specified and directed. |
| 76 | Supply and fix Modular Switch , Two way 6 amps, 230 volts, 1 module complete all as specified and directed. |
| 77 | Supply and fix Modular Switch , one way 16 amps, 230 volts, 1 module complete all as specified and directed. |
| 78 | Supply and fix in Modular Socket,(White) 6A - 2/3 pin combined 2 module, 230 volts as per sample complete all as specified and directed. |
| 79 | Supply and fix in Modular Socket,(White) 16 A - 2/3 pin combined 2 module, 230 volts as per sample complete all as specified and directed. |
| 80 | Supply and fix , ceiling rose three terminal surface PVC/Polycarbonate, type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed. |
| 81 | Supply and fix in Modular White cover suitable with frame 12 module complete all as specified and directed. |
| 82 | Supply and fix in Modular White cover suitable with frame 4 module complete all as specified and directed. |
| 83 | Supply and fix in Modular White cover suitable with frame 3 module complete all as specified and directed. |
| 84 | Supply and fix in Modular metal flush box suitable with 12 module complete all as specified and directed. |
| 85 | Supply and fix in Modular metal flush box suitable with 4 module complete all as specified and directed. |
| 86 | Supply and fix in Modular metal flush box suitable with 3 module complete all as specified and directed. |
| 87 | M & L for submain wiring comprising single core, 2 runs of 6 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including appropriate dia. In surface/ recessed PVC conduit and its fittings complete including provision of 1 run of 6 Sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using colour code as per IS and specified and making good all disturbed work to match the existing complete all as specified and directed by Engr-In-charge. Note :- i) 3 runs of 6 sq mm cable and one run of PVC conduit and its accessories shall be considered as 1 for measurement and payment purpose.ii) Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly. |
| 88 | M & L for submain wiring comprising single core, 4 runs of 10 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including appropriate dia. In surface/ recessed PVC conduit and its fittings complete including provision of 1 run of 10 Sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using colour code as per IS and specified and making good all disturbed work to match the existing complete all as specified and directed by Engr-In-charge. Note :- i) 4 runs of 10 sq mm cable and one run of 10 sqmm copper cable earth wire and PVC conduit and its accessories shall be considered as 1 for measurement and payment purpose.ii) Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly. |
| 89 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 90 | M&L for LED Batten 20W with LED tube light integrated LED channel of capacity 20 Watts white colour complete all as specified as directed by Engg in charge. |
| 91 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with Silica filled driver for wet protection along with SPD Protection, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting in flexible conduit and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 metre long bend to required shape fitted with clamp complete including removal of old unserviceable fitting all as directed by Engineer-in-Charge. |
| 92 | M&L for street light bracket made out of 32 mm dia GI tubing medium grade up to 1.5 metre long including bending, welding ,drilling holes as required and fixing with flat iron clamps 32x 6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/wall complete all as specified and as directed. |
| 93 | S & F sheet metal enclosure MCB VTPN 8 way Double door Ready to use DBs - Provided with insulated vertical phase bus-bars, neutral bar/s with shroud/s , earth bar/s , sticking saddles , cement spill protector, color-coded interconnecting wire set, cable ties , blanking plates and circuit identification labels With provision for 4 Pole MCCB 160 A as incomer and SP/SPN MCBs as outgoing complete all as specified and directed. |
| 94 | S & F MCB DB TPN 4 way with 200A rated copper busbar with mild sheet enclosure vertical double door type suitable for fixing MCBs including connecting etc complete all as specified and directed |
| 95 | S&F MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed. |
| 96 | Supply and fixing MCCB ( 4 pole) 160 Amps 415 Volts of braking capacity 25 KA complete all as specified and directed. |
| 97 | Supply and fix MCB SPN 32 Amp 240 V 50 Hz, C - Curve AC Supply complete all as per specified and directed. |
| 98 | Supply and fix in replacement MCB SP 5 to 32 amp, C- Curve complete all as per specified and directed. |
| 99 | Supply and Fix single pole and neutral enclosing with a two pin and earth plug socket complete with one single pole MCB 20 A ,240 V complete all as specified |
| 100 | Supply and fix MCB TPN 63 Amp 415 V 50 Hz, C- Curve AC Supply complete all as per specified and directed. |
| 101 | Taking down carefully existing copper/aluminium point wiring (light/fan/sockets points ) complete with all accessories such as switch with sheet, ceiling rose including rusted/broken concealed sunken boxes etc but except concealed conduit and junction boxes and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed by Engineer-in-Charge. |
| 102 | Taking out unserviceable MCB DB any size complete by disconnecting all as directed. |
| 103 | Taking down carefully existing copper/aluminium submain of any type concealed conduit and junction boxes and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed by Engineer-in-Charge. |
| 104 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made out of GI and GI earth wire protected by 15 mm bore light grade GI pipe as well as 20 mm dia medium grade pipe 1.5 metre fixed with funnel and wire mesh as specified and connected all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1 : 2 : 4 type B - 1 in chamber and 40 mm thick RCC 1 : 2 : 4 type B - 1 cover slab with 6 mm dia mild steel bars at 100 mm centre to centre both ways with 6 mm dia M S hooks complete all as specified. Note : The GI Wire 4 mm dia &15 mm bore light grade GI pipe up to 7.5 M deemed to be included in the rate quoted by the contractor. Beyond 7.5mm GI wire 4mm dia and GI tubing light grade 15mm dia shall be measured and paid under the respective item of schedule |
| 105 | Removal of old U/S AC Plant duct from existing infra carefully from ceiling complete all as specified and directed. |
| 106 | Supply, installation, balancing and commissioning of factory fabricated galvanized steel sheet metal (G.S.S.) round / rectangular ducting of following sheet thickness having zinc coating of 120 g/m² total on both sides and complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, volume control dampers, hangers, supports, etc. as per approved drawings and conforming to the latest edition of IS 655: 2006 & HVAC Duct Construction Standards - Metal and Flexible of SMACNA along with required scaffolding work to install the ducts at site including necessary fixing accessories of MS angle iron rods ,clamps, bolts and nuts on wall/roof as applicable and leak testing complete of size 22 Guage complete all as specified and as directed. |
| 107 | Supply and installation, Testing and commissioning Acoustic insulation of supply air ducting with 19mm thick closed cell electrometric nitrile rubber with density minimum 43kg/m3, anti - microbial with EPA approved and fire performance to pass, class - 1 as per BS 476 part-7 and class O as per BS 476 part 6 and use recommended adhesives/SR 505 grade Fevicol and covered with 7mm thick chemically treated woven glass cloth having density 205+/- 10gram / sqm and affixed using synthetic contact adhesive of approved make and covered with 24G aluminium cladding for all exposed ducts complete all as specified and as directed. |
| 108 | S & F in replacement of supply / return / exhaust air diffusers / grilles / louvers for HVAC powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core complete all as specified and as directed. |
| 109 | Supply and fixing of Fire alarm control panel addressable, microprocessor based for 4 Zone each loop capable of handling 10 detectors including suitable battery backup 7AH 12 Volt, three battery. The panel must support gsm auto dialler for sending out recorded information complete all as specified and directed. |
| 110 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 2 core, 1100 Volts grade, with Required Accessories all as specified and as directed . |
| 111 | Supply, Installation ,Testing & Commissioning of addressable Multi Sensor (Smoke -Heat) which is fully compatible with removable high performance chamber with Twin fire LED's allow 360 degree viewing, User selectable sensitivity modes 0 to 88 degree Celsius, Incorporates Fixed Temperature and Rate Of Rise Heat and smoke elements, lock mechanism ( sensor to base), Electronically addressed, Pulsing/non-pulsing controlled from panel, rotary switches for addressing at base complete all as specified and directed. |
| 112 | Supply and fix Remote response indicators complete all as specified and directed. |
| 113 | Supply and fixing of addressable manual call point resettable type including transparent safety cover with back box complete all as specified and directed. |
| 114 | Supply and fixing of conventional electronic sounder cum strobe with back box,32 tone selction, EN 54 complete all as specified and directed. |
| 115 | S&F MS pipe 15 mm dia all specials like tees, bends, flanges, nuts, bolts and washers etc laid in open, suspended from roof/ laid in trenches etc including supporting fixtures of GI clamping as per following sizes complete all as specified and as directed . |
| 116 | Supply and fix Short circuit isolators complete all as specified and directed. |
| 117 | Supply and fix 6 Watt ceiling Speaker complete all as specified and directed |
| 118 | Supply and fix modular fire extinguisher CO2 Base ABC, dry chemical powder or clean gas having sprinkler technology complete all as specified and as directed. Make :Agni, Honeywell, Gst ,ravep Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender