Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57627058

Tender For Special Repair To Hanger Number P-39(Annexe)

Issued by Statutory Bodies & Commissions/Committees · Patiala, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Oct 2026
19 days left
EMD
66800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Hanger Number P-39(Annexe)

BOQ

Name of Work:- SPECIAL REPAIR TO HANGER NUMBER P-39(ANNEXE)
Sl. No. Item Description
1Dismantling of brick tiles or terracing tiles single layers laid bedded and pointed in any mortar on roofs complete all as specified and directed.
2Removing of Mud in roofs, any thickness, including plastering and leeping (whether full thicknes removed or only a part thereof)
3M&L for wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc. complete all as specified and directed.
4M&L for cement concrete 1:3:6 type C1 using 20 mm graded aggregate as in padding over roof complete all as specified and directed.
5M&L for 10 mm thick rendering on top of roof in CM 1:4 incl mixed with WPC(WPC shall be paid separately)
6Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 3.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including on a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm thick 5 layered APP membrane shall be laid using butane torch and sealing all joints etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength in longitudinal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147
7M&L for two coats of aluminium paint over APP water proofing membrane complete all as specified and directed.
8Taking down chowkhats or frames (without taking off shutters from the frame) not exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
9Taking down chowkhats or frames of any description exc 1.5 Sqm but n. exc. 4 sqm each (without taking off shutters from the frame) including cutting hole to size for receive fresh PCC of hold fast and making good the disturbed surface complete all as specified and directed.
10S&F 2nd class hard wood factory made plain framed panelled door shutters 35mm thick (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both sides. The size of rail and stiles as per IS:1003 (Part I), Klin seasoned and chemically pressure treated complete all as specified and directed.
11S&F factory made solid PVC door, cup board shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded both side prelaminated PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & prelaminated PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail, lock rail & bottom rail panelling of prelaminated PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specification & diagram/product drawing shown on ser page No 156 of SSR Part II complete all as specified and directed.
12S&F factory made solid PVC door, cup board frame size 50mmx47mm made out of 5mm Prelaminated PVC sheet reinforced with MS square tube all as per specification and as per drawing shown on ser page No 150 of SSR Part II (for item 884) complete all as specified and directed.
13M&L Steel Window Box type factory made frame using ERW comprising 'P' Section(outer) and T section(Mulions), Double Frame for Gauged and Glazed Shutter jointed internally with Flat Iron 40x3mm. Gauged and Glazed shutter comprising 'P' section of 40x20mm complete including welding of Mild Steel Tower Bolts, Hinges, Handle, Stops, Lugs including Stainless steel wire cloth, Glazing, gaurd bars etc. incluiding painting with two coat synthetic enamel paint over a coat of primer complete all as directed. Outer Section of Frame shall be 50x25mm complete all as specified and as directed.NOTE :-(a) For the purpose of Measurement & Payment Double Shutter with Frame shall be considered as One Unit.(b) Cost of Iron Mongery as ordered/required at Site, will deem to be included in the Quoted Unit Rate.(c) Guard Bars are included in the Quoted Unit Rate,10mm Square Bar will be 10 Cm Centre to Centre.(d) Glazing and Stainless steel wire cloth 0.36mm normal dia of wire and average width of aparture 1.40mm are included in the Quoted Unit Rate.
14M&L fixed Steel ventilator Box type factory made frame using ERW comprising 'P' Section(outer) and T section(Mulions), single Frame partially glazed and partially gauged with mild steel welded mesh incluiding gaurd bars and painting with two coat synthetic enamel paint over a coat of primer complete all as directed . Outer Section of Frame shall be 50x25mm complete all as specified and as directed.NOTE :-(a) Guard Bars are included in the Quoted Unit Rate,10mm Square Bar will be 10 Cm Centre to Centre.(b) Glazing and mild steel welded mesh are included in the Quoted Unit Rate.
15M&L for repair of rolling shutter of hangers without taking down of existing shutter including replacement of roller/slider/any parts(roller/slider/any parts will be measured and paid separately) of shutter as well as greasing/oilin of shutter to make it function smooth, area of hangers exc 20Sqm complete all as specified and directed.Note: (i) Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. (ii) Rate quoted by the tenderer deemed to be inclussive of all arrangements required for repairing, such as provision of cranes/scaffolding and any other T&P required; nothing extra will be payable on this account.
16S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming Fe-290(Gde E 165) complete all as specified and directed.
17M&L Preparation of New surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying Two coat of synthetic enamel paint,incl one coat Primer complete all as specified and directed.
18M&L complete removal of existing treatment and preparation of old painted steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
19M&L for New or previously untreated steel surfaces over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide cinc chrome primer complete all as specified and directed.
20S&F for 4mm thick sheet glass, selected quality and glazing with oil putty in square n exc. 0.5 sq. m each pane complete all as specified and directed.
21S & F factory made pressed steel frames size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed.
22M & L for providing PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in filling pressed steel frame complete all as specified and directed.
23M&L for 150mm long mild steel handles, oval type complete all as specified and directed.
24S&F 150mm mild steel barrel tower bolt complete all as specified and directed.
25S&F mild steel sliding door bolt, plate type stove enamelled blac, with bright bolt 300mm length & dia not less than 12mm with & including a minimum 6 Nos of bolts and nuts, four on bolt plate and two on stapple plate complete all as specified and directed.
26M & L providing, cement concrete type C-I 1:3:6 (using 20 mm graded aggregate) as in bed plates (for hold fast block) etc. complete all as specified & directed.
27M&L plain cement concrete type C-1 1:3:6 using 20 mm graded aggregate as in sub base for raising the exiting floor finish complete all as specified and directed.
28M&L for 25mm thick PCC (1:2:4) type B0using 12.5mm graded stone agg as in Top surfaces finished even and fair complete all as specified and directed.
29M&L machine cut Kota stone slab 18 to 20 mm thick as in flooring or treads of step incl half round moulding over and including screed bed 15 mm thick in CM (1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified.
30M&L machine cut Kota stone slab 18 to 20 mm thick as in riser to step including 10 mm thick rendring in CM (1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified.
31Grinding and Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high glossy finish complete.
32Demilition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
33M&L PCC type C-2 Mix 1:3:6 (40mm graded stone aggregate), 75mm thick in plinth protection/path finishing the surface even and smooth without using extra cement with joints filled with bitumen grade 85/ 25 and sand in equal proportions by weight complete all as specified and directed.
34Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
35M&L for 75mm thhick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in Sub base finished even and rough complete all as specified and directed.
36Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
37Demolition of Brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
38M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggt in foundation, filling, mass concrete complet all as specified and directed.
39M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan & exc 6 m mean radius with old size bricks including scaffolding wherever required complete all as specified and directed.
40M&L for PCC (1:2:4) type B-0 using 20mm graded crushed stone agg as in coping /benching in man hole etc,finished even and smooth using extra cement incl necessary form work
41Taking down cement or lime plaster of any description from stone or brick walls etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish complete all as specified or directed .
42Material & labour for 15mm thick rendering on surfaces other than fair faces of brick/concrete surfaces in CM (1:6) and finished even and smooth without using extra cement.
43Material & labour for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM (1:4) finished even and smooth without using extra cement mixed with water proofing compound.( Note- Water proofing compound should be mesured and paid separately )
44Supply only liquid water proofing compound
45M&L 5mm thick cement plastering in CM 1:3 on fair faces of concrete ceiling surfaces finished even & smooth without using extra cement complete all as specified and directed.
46M&L for preparation of new plastered surfaces on walls and applying two coats of oil bound distemper with 1mm thick white wall care putty and a coat of primer complete all as specified and directed.
47M&L for prepartion of new plastered surfaces on walls and applying two coats cement base paint over one coat of Primer on walls complete all as specified and directed.
48Preparation of surfaces of plastered or unplastered new surfaces of ceiling/wall applying three coats of white wash incl Preparation of surfaces complete all as specified and directed.
49Dismantling timber scantling 40Sqcm and over in section in any position in framed work as in rafters,
50S & F rolled mild steel in joist, angle ,channel as in purlins, rafters cleats etc conforming to Fe-410- W (Gde-E-250)quality A, all as directed.
51S& F mild steel welded fabric of any size of aperature and dia of wire fixed to steel members with welding as in hangers up to height of 9 mtr including scaffolding wherever required complete all as specified.
52Preparation of old treated surfaces of steel/asbestos sheet (wall/roof) and applying one coat of synthetic enamel paint as in camouflaging pattern having percentage of colour as 40% olive green, 40% dark brown and 20% sand stone at height n.exc 15mtr as per sample/pattern approved by GE complete all as specified and directed by Engr-in-Charge. Note : 1. The %age of the three colours may change without any financial effect by the approval of GE. 2. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account.
53Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
54M&L for Non Skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.06 Sqm but n. exc 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6 all as specified.
55M&L for Glazed ceramic tiles coloured (300x450mm) x 7mm thick, in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick backing coat of tiles in CM (1:4) complete all as spd
56Taking up or down of 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
57Taking up or down of 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
58S&F 15mm bore tubes, `medium grade', galvanised, with all fittings and fixed complete concealed to walls and ceilings or laid in floors complete all as specified and directed.
59Cutting chase, pinning in making good to facing where required and pointing in CM 1:3 to end or edges of landing steps, cills, sunshades, shelves, lintels etc. and cutting chase for conceled water pipe etc. and making good cutting not exc 10Cm girth on Brick walls.
60S&F 20mm bore tubes, `medium grade', galvanised, with all fittings and fixed complete concealed to walls and ceilings or laid in floors complete all as specified and directed.
61Dismantling of water tanks exc 500 & n exc 1000 ltr capacity & removing to store all as directed.
62S&F rotational moulded PVC water storage tank cylinderical, vertical with closed top of 750 ltrs capacity, hoisted and fixed in position with and including PTMT float valve 20mm dia and making connections for inlet and outlet complete all as specified and directed.
63S&F in repair 15mm bore CP angle cock with flage complete all as specified and directed (Cat part No 8310 of Make-Prayag or its equivalent make)
64S&F in repair bib taps (long body) 15mm bore of fancy type cast copper alloy chromium plated fancy type, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
65S&F vitreous china wash basin, white flat back size 550x400 mm including waste pipe, brackets and cutting for and pinning in ends of brackets or errecting stand but excl taps, chain and plug complete all as specified and directed.
66Supply and fixed pillar taps cast copper alloy with capstan head, chroumim plated fancy type. Screwed down high pressure with or w/o lettered \\"Hot\\" or \\"cold\\" with long screwed shanks and flynuts of 15mm bore complete.
67S&F vitreous china urinal bowl type ( back or corner wall type and fixing plugs bedding urinal against wall in cement mortar 1:2 securing with plugs and 60mm long brass screws, pointing arroud urinal backing cement and with grating and union for discharge pipe complete all as specified and directed..
68S&F in repair PVC connection 600mm long of dia 15mm complete all as specified and directed.
69S&F in repair soap dish of 1mm thick stainless steel box type fixed with screws of size 150mmX150mmX100mm complete all as specified and directed.
70S&F decorative type Mirror of 5 to 6 mm thick with beveled /grind and fixed with studs including 8 to 9 mm thick PVC solid sheet backing and PVC beading/border all around of size as specified and all as directed by Engineer-In-Chagre
71M&L 18-20mm thick Granite (of any type) work (tablee rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed.
72S&F in repair tubular towel rail 20mm dia D type and 60cm long including brackets fancy type brass chromium plated complete all as specified and directed.
73S&F PVC floor trap with grating including jointing waste pipe in 100mm dia fixed in jointing with solvent cement complete as per direction by Engrin-Charge.
74M & L in repair PVC ( SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed.
75S&F 40mm dia PVC waste pipe flexible 750mm long including nut washer cup bracket complete all as specified and directed by Engr-in-Charge
76S&F in repair PVC flusing cistern low level 10 Ltr capacity of approved make including fixing of brackets connection to WC with CI brackets and making good disturbed area complete all as directed.
77Demolition and breaking up drain pipes (salt glazed ware,AC or Reinforced concrete) set in cement mortar internal dia of pipe upto 100mm complete all as specified and directed.
78S&F 75 mm bore PVC (SWR ) pipe in any length fixed to walls and floor with and including rubber ring joint and MS clamps ..
79S&F 110 mm bore PVC (SWR ) pipe in any length fixed to walls and floor with and including rubber ring joint and MS clamps ..
80S & F PVC(SWR) bends 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors
81S & F PVC(SWR) bends 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors
82Taking down carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc removing materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of credit and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
83M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor for one light/fan/bell point in and including NEW PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with PVC modular top cover plates of suitable size for mounting of modular type switches/sockets/regulators including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engr-in-charge.Notes: (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth.(iii) -Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item.
84All as per Sl item No 83.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
85All as per Sl item No 83.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
86All as per item No.83.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH copper earth wire for switch socket combination 3 pin 15 amps on independent board.
87S & F in replacement of Modular switch 1 way, 6 Amps, 1 module, 230 volts complete all as specified.
88S & F in replacement of Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified.
89S & F in replacement of Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified.
90S & F in replacement of Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified.
91S & F in replacement of Modular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified.
92S & F in replacement of ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed
93S & F in replacement of New generation energy saving and environmental friendly long life LED building security light 1x35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge.
94S&F incl taking down 20 watt wall mounted, new generation LED batten fitting length ~ 4 feet with polycarbonate diffuser andextruded thermoplastic body > 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500/3000 K with CRI of LED >90 . including all fixing accessories & connecting up with PVC insulated twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge.
95Supply and fix mirror light with linear & compact 12 W mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser of capacity 9 watt complete all as specified and directed by Engr-in-charge.
96Supply and Fix Lamp holder PVC/polycarbonate type with back plate suitable for batten fitting including LED bulb 9 W including flexible wire 0.5 Sqmm copper cable all as specified & directed by Engr-in-charge.
97S & F MCCB, 4 Pole, 125 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
98Supply and fix in replacement of epoxy power coated MCCB distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size complete all as specified and directed by Engr-in-charge.
99Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
100S & F in replacement of MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge.
101Supply and fix in replacement of MCB , SPN, 240 Volts ,40-63 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge.
102M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring.
103M & L for Sub main wiring with two single core 2.5 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 2.50 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 2.5 Sqm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
104M & L in replacement of UNSV Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497.
105XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core supplied & laid in replacement complete all as specified& directed by Engineer-in-Charge.
106Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
107Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm thick each layer of any kind of soil.
108Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
109Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm above with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
110Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete 1:2:4 type B-0 all as specified and directed.
111Supplying & laying factory made unreinforced Precast concrete cable covers class LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables complete all as directed by Engr-in-Charge
112Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
113Supply and fix Exhaust fan AC single phase 230/240 v of size 250 mm sweep 900 rpm Engineering thermoplastic body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver complete all as specified and directed by Engineer-in-Charge.
114Material and labour for making hole of suitable size for exhaust fan 250 mm/ 300mm sweep in wall for grouting and making good the surface complete all as specified and directed by Engr-in-charge.
115Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with MCB SPN 32 Amps, complete all as specified and as directed by Engineer-in-charge.
116Supply and installing of water heater storage type of capacity 25 liters with electrical heating back up of 2 KW including all necessary required acessiories like pvc / cp connections, necessary nut bolts, washers, screws etc and make up water tank complete all as specefied and directed.
117S & F gun metal gate valve, suitable for 15mm bore GI pipe with iron wheel head, screwed both end for GI pipe with all necessary fittings complte all as specefied and directed.
118Supply and Fixing Bib tap cast copper alloy with butter fly handle fancy type suitable for 15mm GI pipe with necessary fittings complete all as specefied and directed.
119S & F gun metal non return valve, suitable for 15mm bore GI pipe with screwed both end for GI pipe with all necessary fittings complte all as specefied and directed.
120S & f industrial high Bay LED Light of capacity 120 W, The LED Make must be of minimum 100 lumen/Watt. The driver must be of power factor>0.95 with short circuit protection, high voltage protection, the luminaire must have secondary optics with perfectly matched lens for better light control with CMRI approved correlated colour temperature (CCT) of emitting light 5700K with die cast aluminium housing with heat resistant toughened glass IP 66 protection complete withcontrol gear box and all accessories required to fix the light on wall/structure/pole with clamps, nuts, bolts etc with suitable size and including connecting upto with twin core twisted flexible copper conductor cable 1.5x2 sqmm with proper clamps complete all as specified and directed by Engr in Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57627058
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 13-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Hanger Number P-39(Annexe)
Basic Detail
Tender No GE (N)/TOKEN-83/2026-2027
Bidding Type Tender
Location
City Patiala
State Punjab
Key Dates
Publish Date 21 Sep 2026
Submission Date 13 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 66800
Exemption Available
Document List
752f6588-1de6-4004-bc38-63c0b58d4796.html
BOQ_886002.xls
TENDERDOCUMENTS.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

752f6588-1de6-4004-bc38-63c0b58d4796.html

xls

BOQ_886002.xls

pdf

TENDERDOCUMENTS.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders