Tender For Special Repairs To Toilet, Water Supply, Painting And Other Civil Works In Dro C Office At Thiruvallur.
Tender Value
9.30 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
3 days left
EMD
9300
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repairs To Toilet, Water Supply, Painting And Other Civil Works In Dro C Office At Thiruvallur.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and clearing away and carefully stacking the materials useful for reuse of Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs. |
| 2 | Relaying of Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by mechanical means |
| 3 | Reconstruction of Brick work in Cement Mortar 1:5 (one cement five sand) using best quality Burnt Clay Brick of size 9\\" x 4 3/8\\" x 2 3/4\\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. |
| 4 | For Foundation and Basement |
| 5 | Reconstruction of Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9\\" x 4 3/8\\" x 2 3/4\\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. |
| 6 | In Ground Floor |
| 7 | Renewing and refixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers. |
| 8 | 110mm dia PVC Pipe for One Floor |
| 9 | Renewing and refixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. |
| 10 | 50mm thick slab (using 20mm HBGS Jelly) |
| 11 | Renewing the damaged floor with best approved quality fine polished Granite Stone Slabs of Size : 1200 x 600 of 18 / 20mm thick and Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with matching colouring pigments etc., complete complying with standard specification and as directed by the departmental officers. (The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work). |
| 12 | Fine Polished Granite Slab of Size : 1200 x 600 of 18 / 20mm thick |
| 13 | Renewing the damaged flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works). |
| 14 | Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm |
| 15 | Renewing the damaged Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 16 | Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm |
| 17 | Replastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 18 | Renewing and refixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/Cub.Mt. & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the Aluminium “G” type channel with Wheel and the door shall have 2 Hooks in SS, 2 Handles 4” in SS (Sliding door) etc., complete and as directed by the departmental officers. |
| 19 | Renewing the damaged Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work. |
| 20 | Repainting Old Plastered Wall Surface with Two finishing coats of ready mixed Interior (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 21 | Repainting Old Plastered Wall Surface with Two finishing coats of ready mixed Exterior (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 22 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 23 | Renewing the damaged UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Below ground level. |
| 24 | 25mm dia (AGL) EWS |
| 25 | 20mm dia (AGL) EWS |
| 26 | Renewing the damaged UPVC Specials in water supply arrangements (both in internal and external water supply arrangements. |
| 27 | 25mm dia UPVC Elbow |
| 28 | 20mm dia UPVC Elbow |
| 29 | 25mm dia UPVC Tee |
| 30 | 20mm dia UPVC Tee |
| 31 | Renewing and refixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 32 | Renewing the damaged in position white / colour glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works). |
| 33 | White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall |
| 34 | Renewing and refixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). White Glazed Wash Hand Basin. Without Pedestal. |
| 35 | Renewing the damaged Stainless Steel Sink of following sizes with 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works] |
| 36 | Stainless Steel sink of 600 x450 x 200mm |
| 37 | Renewing and refixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works). |
| 38 | Renewing and refixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. |
| 39 | 110mm Dia |
| 40 | Renewing the damaged in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 41 | 25mm dia Gate Valve |
| 42 | Renewing the damaged cylindrical vertical notational polythene water storage tank of 2000 litres capacity confirming to I S. 12701 / 96. the tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simply pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., and the tank should be fixed firmly as directed. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., (The water tank should be got approved by the Executive Engineer before use on works by the dept., Officers. |
| 43 | Renewing the damaged Leach pit reconstruction of new leach pit with necessary excavation, well rings 6 numbers of 90cm dia and RCC covering slab 50mm thick including cost of all materials, labour charges etc., complete as per standard specification. |
| 44 | Renewing the damaged Main Table of size 2400mm x 1200mm x 750mm (H) side table size 900mm x 400mm x 750mm(H) - Top & leg 25mm thick particle board duly post formed edge with 0.6mm thick flex laminate. Modestry panel 18mm thick prelaminated particle board duly edge banded. with 3 drawer fixed to top main table & side table. Please Enable Macros to View BoQ information |
| 45 | Renewing the damaged Main Table of size 2400mm x 1200mm x 750mm (H) side table size 900mm x 400mm x 750mm(H) - Top & leg 25mm thick particle board duly post formed edge with 0.6mm thick flex laminate. Modestry panel 18mm thick prelaminated particle board duly edge banded. with 3 drawer fixed to top main table & side table. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender