Tender For Electrical Installation Work For The Proposed Oxygen Plant And Manifold Room Of Tertiary Cancer Care Centre(Tccc), Under Burdwan Medical College And Hospital, Purba Bardhaman.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Oct 2026
5 days left
EMD
36255
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Installation Work For The Proposed Oxygen Plant And Manifold Room Of Tertiary Cancer Care Centre(Tccc), Under Burdwan Medical College And Hospital, Purba Bardhaman.
BOQ
| Sl. No. | Item Description |
| 1 | DISTRIBUTION WIRING :Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) |
| 2 | a)25mm dia 3mm thick Polythene Pipe |
| 3 | a)19mm dia 3mm thick Polythene Pipe |
| 4 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC |
| 5 | a)Average run 8 mtr |
| 6 | b)Average run 9 mtr |
| 7 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. |
| 8 | a) Average run 6 mtr |
| 9 | b) Average run 8 Mtr |
| 10 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 11 | a)Average run 9 mtr |
| 12 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish |
| 13 | a)On Board |
| 14 | b)Average run 7.5 mtr |
| 15 | S&drawing 1.1 kV single core stranded FR PVC insulated &unsheated single core stranded cupper wire (approved make)of the following sizes prelaid poly pipe. & by the Gifish wire & making necy connection as required. |
| 16 | a) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (From HTPN DB to SPN DB) |
| 17 | b) 2X 56/0.3( 4 sqmm) + 1 X 36/0.3( 2.5 sqmm) as ECC ( From HTPN DB to AC ) |
| 18 | c) 2X36/0.3(2.5 SQMM)+1*22/0.3(1.5SQMM) as ECC (For Power Plug & Computer Point) |
| 19 | d) 3 X 22/0.3( 1.5 sqmm) |
| 20 | e)4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 21 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 3 mm thick Polythene pipe (without earth continuity wire) by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles incl. S&F of following pipe |
| 22 | i. 19 mm dia pipe |
| 23 | ii. 25 mm dia pipe |
| 24 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make]on wall, ceiling with saddles and other accessories as requiredand mending good damages to building works |
| 25 | i. 19 mm dia pipe |
| 26 | ii. 25 mm dia pipe |
| 27 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 28 | i. 2.5 sq.mm. |
| 29 | ii. 4 sq.mm. |
| 30 | iii. 6 sq.mm. |
| 31 | PLUG & INDUSTRIAL SOCKETS :Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the 200 mm x 150 mm x 65 mm sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works along with Supply and fixing 2 no 16 A Piano Key type Switch and 2 no 16 A plug Socket. Brand approved by EIC |
| 32 | Supplying & Fixing Industrial Plug & Socket board with 415 V, 63A, TPN & Earth Metal Industrial Plug socket & 63A Industrial top incl. S&F 63 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. Make:- As per choice of EIC. |
| 33 | Supplying & Fixing Industrial Plug & Socket board with 415 V, 32A, SPN & Earth Metal Industrial Plug socket & 32A Industrial top incl. S&F 32 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. Make:- As per choice of EIC. |
| 34 | Power Distribution board :Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment upto Make:- Legrand/Schneider/Siemens |
| 35 | 4 way Enclosure (607913) upto 160 A |
| 36 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment |
| 37 | a) 6 way Enclosure (607716) |
| 38 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 39 | a) 2 + 14 way Enclosure (607712) |
| 40 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection |
| 41 | a) 125 A |
| 42 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection |
| 43 | 6-32 A SP MCB |
| 44 | 40 A SP MCB |
| 45 | 63 A TP MCB |
| 46 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. |
| 47 | a) DP 40 A |
| 48 | b) FP 63 A |
| 49 | Cable for Distribution Board and other Auxiliaries:Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) (Make : Polycab/RR/Havells/Gloaster)as per choice of EIC |
| 50 | ii. 4 core 150 sqmm |
| 51 | iii. 4 core 50 sqmm |
| 52 | iv. 4 core 25 sqmm |
| 53 | Laying of cable above on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 54 | ii. 4 core 150 sqmm |
| 55 | iii. 4 core 50 sqmm |
| 56 | iv. 4 core 25 sqmm |
| 57 | Laying of cable as below, after cutting wall and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish |
| 58 | ii. 4 core 50 sqmm |
| 59 | iii. 4 core 25 sqmm |
| 60 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. |
| 61 | i. 4 core 150sqmm |
| 62 | ii. 4 core 50 sqmm |
| 63 | iii. 4 core 25 sqmm |
| 64 | Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for |
| 65 | b) 4 Core 150 Sqmm |
| 66 | Laying of two cables above 35 sqmm and upto 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed |
| 67 | 4 core 150 sqmm |
| 68 | S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entryof XLPE/PVC armoured cableas & Finishing the end of the following XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: |
| 69 | i. 4 core 150 sqmm |
| 70 | ii. 4 core 50 sq. mm. |
| 71 | iii. 4 core 25 sq. mm. |
| 72 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. |
| 73 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 74 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. |
| 75 | Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With out iron support 200x50x1.25mm (18SWG) |
| 76 | Fittings and fixer :Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.(Make:- Usha Striker, Crompyon, Orient) |
| 77 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 78 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. |
| 79 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. |
| 80 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) |
| 81 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.Make:- EPC/Orient/Usha as per choice of EIC |
| 82 | Supply & delivery of 230 V, 50 Hz, single phase, 48 watts, 12\\" (300 mm) Sweep, speed 900 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 1145 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.Make:- EPC/Orient/Usha as per choice of EIC |
| 83 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 84 | a) 9\\"(23 cm) Exhaust Fan |
| 85 | b) 12\\" (30 cm) Exhaust Fan |
| 86 | Supply & Fixing GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for |
| 87 | a) 9\\"(23 cm) Exhaust Fan |
| 88 | b) 12\\" (30 cm) Exhaust Fan |
| 89 | Fixing of single LED tube light fitting attached with the wall with 2 No. “V” type MS clamp whose one side inserted within the wall and other side connected with the suitable size of bolts and nuts incl. S&F\\"V” type MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm unsheathed stranded 1.5 sqmm copper wire of 0.5mt. length. incl. 2nos mounting kit. |
| 90 | Fixing of single/double LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side inserted within the ceiling reinforcement and other side connected with the suitable size of bolts and nuts incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm flexible copper wire of 1.10 mt. length. incl. 2nos mounting kit. |
| 91 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0° to 40° C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt) |
| 92 | a)single fittings along with S/F of 1 no. 18-20 W LED lamp as perspecification (Make:- Phillips/Crompton/Bajaj) |
| 93 | b)Twin fittings along with S/F of 2 no. 18-20 W LED lamps as perspecification (Make:- Phillips/Crompton/Bajaj) |
| 94 | Panel work, Rising Main & Main switch/Change Over:Supplying and fixing 415V, 400 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.Make:- L & T /Siemens/ABB or as per choice of EIC. |
| 95 | Oxygen Room Electrical Panel:SITC of indoor type L.T. Panel Board with SFU as Incomer and SFU as outgoing feeders in a suitable transportable unit, ready for operation on being installed in a fixed position. The Panel board shall be Self-supporting, fully Compartmentalized, Incomming / Outgoing SFU Compartment Should be Seperate, floor mounted, indoor type, dust and vermin proof (IP 42), Incoming and outgoing cable entry from bottom / top end at rear side / side cable alley. Gland plate (2 mm thick) should be two part detachable type. The switch board shall be fabricated from 1.6 mm thick (16 SWG) CRCA sheet and base channel will be 50mm x 25mm x 5mm (painted with Black Japan after derusting). The doors shall be removable type mounted on hinge with key locking arrangement for each compartment. |
| 96 | Painting : Panel should be properly degreased, derusted before phospheting. Alkalyed melamine epoxy based powder coated paint to be done by using 7 tank process with minium thickness of 70 micron avg. Shade will be Pebble Grey No. RAL 7032 both inside and outside. Continious GI Earth bus of size 40 x 6 mm to be provided at a hight of 100 mm from the bottom and brought outside of the panel of 50 mm. Depth of the panel : As per direction of EIC. C P R I - Type Test Report for the Panel Board (similar type from Manufacturer) |
| 97 | Termination : Incoming cable termination Bus should be suitable for termination of requisite nos. Ar/Al XLPE/PVC cables. Outgoing feeder terminals should be as per rating. |
| 98 | System Voltage : 415V, 50Hz, RYBN. Control wiring cable size : 1.5 sqmm PVC FR Cu multistrand flexible wire with proper socketing with PVC sleeve & identification ferruling. CT Secondary wiring to be done with 2.5 sqmm PVC FR Cu multistrand flexible wire. (Make- RR Kabel / Havell's / Polycab/KEI). |
| 99 | Incoming :-415V, 400 A, TPN open execution type Change over, SDFU with 3 nos. HRC Din type fuse . Make: L&T/ ABB/ Siemens -- 1no. (Interconnecting Cu bar between SFU and main Bus Bar - 4 x 20 x 5 mm |
| 100 | Bus Bar Arrangement :-S & F 415V,630A current carrying capacity electrolytic grade tinned copper BBC 4 x 40 x 5mm in size for neutral & phases. The entire bars are insulated with PVC heat sinkable sleeve of suitable size & colour as per direction of E.I.C. -- 1 set. |
| 101 | Outgoing :- a) 415V, 250A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T-- 1 nos.b) a) 415V, 200A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T-- 1 nos. d) 415V, 125 A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T--2 nos. d) 415V, 63A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T--2 nos. |
| 102 | Metering. Control & Indication Arrangment :-a) 0-500V Analog Voltmeter, 96mm Dial, Accuracy Class- 1.0, Make-AE.- 1 No.b) 0-415A Analog Ammeter, 96mm Dial, Accuracy Class- 1.0, Make-AE.- 1 No.c) Volt meter selector switch, Make- Kaycee- 1 Nos.d)Ammeter selector switch, Make- Kaycee- 1 Nos.e) CT, 415/5A, 10VA, Accuracy Class- 1.0, Make-Kappaf) LED indicating lamp, make- ESBEE/L&T, (for R,Y,B indicating)g) 6A, TP MCB for volt meter protection-1 nos. Make- Legrand/L&T.h) 6A, TPN MCB for Indicator-1 nos. Make- Legrand/L&T. |
| 103 | Metering, Control or indication wires shall be nearly bunched separately and adequately supported so as to prevent stresses and strain on termination.Foundation for Panel :- Suitable placed and as per panel fabricationBrick Foundation with neat Cement Plastering with hollow for cable entry point. Design should be proper for adequate load capacity. (as directed by EIC) |
| 104 | Compound Lighting : Supplying, installation, Testing & Commissioning of Street light 72 Wt, LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0° to 50° C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage |
| 105 | should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy ≥135 lm/Watt. Make:- Philips, Cropmton, Bajaj |
| 106 | Fixing only outdoor / street light type LED light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 107 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 108 | Supply and Fixing of 240 V timer DB with suitable size sheet steel enclose double door, phosphatised powder coated, neutral bar , din rail with IP-43 protection comprised with 1 no. 32A DP MCB (‘C’ Curve, 10KA), 1 no. 24 hours programmable analog timer switch (min 15 min interval setting) and 1 no. 32A contactor, 1 no. 32A timer bypass switch, 1nos out going stud/ bar complete with internal wiring by 1.1kV grade 4 sq mm. FR PVC insulated copper wire incl. 1 no. auto manual by pass troggle switch and provision for earthing attachment incl. LED indicating light for running condition with locking arrangement. [Make:- L&T /Cabtree/Siemens] |
| 109 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) |
| 110 | 2 Core 10 sqmm |
| 111 | Laying of cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 112 | 2 Core 10 sqmm |
| 113 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 114 | 2 Core 10 sqmm |
| 115 | S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entryof XLPE/PVC armoured cableas & Finishing the end of the following XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: |
| 116 | 2 Core 10 sqmm |
| 117 | Earthing & GI pipe:Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as by ISI-Medium GI pipe |
| 118 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 119 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 120 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 121 | Supplying & fixing medium gauge 100 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required with necessary socketing/welding. |
| 122 | 100 mm dia |
| 123 | 50 mm dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender