Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #57623163

Tender For Repair/Maint Of Lt Cable & Switchgears And Lt Panels At East Gate, Mes Ib, Ecom, Aoi, Manekshaw House And Other Central Institutes Inside Vijay Durg Under Ge(Vd) Kolkata

Issued by Statutory Bodies & Commissions/Committees · Kolkata, West Bengal
Tender Value
35.50 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
8 days left
EMD
71000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Lt Cable & Switchgears And Lt Panels At East Gate, Mes Ib, Ecom, Aoi, Manekshaw House And Other Central Institutes Inside Vijay Durg Under Ge(Vd) Kolkata

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 30-Sep-2026 CORRIGENDUM Other 12-Oct-2026

BOQ

Name of Work:- REPAIR/MAINT OF LT CABLE & SWITCHGEARS AND LT PANELS AT EAST GATE, MES IB, ECOM, AOI, MANEKSHAW HOUSE AND OTHER CENTRAL INSTITUTES INSIDE VIJAY DURG UNDER GE(VD) KOLKATA
Sl. No. Item Description
1Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
2Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed.
3Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
4Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
5M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180Cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
6Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed.
7Laying in Trenches Bricks (Serviceable Bricks obtained from Item No. 9.00 here-in-after), for Cable Protection, complete all as specified and as directed.
8Taking out of interlocking paver block, any shape or size and Re-laying the same after laying of LT cable of any size and also removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed.NOTE : Sand, if required for connection of cushioning level will be measured and paid seperately.
9Supply and Laying of Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 60 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed.
10Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench/pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- Note :- Necessary earth work to be measured and paid separately.
11(a) 10 Sqmm 2/3.5/4 core to 16 Sqmm, 4 core
12(b) 25 Sqmm to 50 Sqmm, 3.5 Core
13(c) 70 Sqmm to 150 Sqmm, 3.5 Core
14(d) 185 Sqmm to 240 Sqmm, 3.5 Core
15(e) 300 Sqmm to 400 Sqmm, 3.5 Core
16Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :-Note :- Necessary earth work to be measured and paid separately.
17(a) 25 Sqmm, 3.5 Core
18(b) 35 Sqmm, 3.5 Core
19(c) 50 Sqmm, 3.5 Core
20(d) 95 Sqmm, 3.5 Core
21(e) 185 Sqmm, 3.5 Core
22(f) 240 Sqmm, 3.5 Core
23M&L for Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No. 9.00 here-in-before) 1100 Volt grade, after fault rectification including necessary aluminium thimbles, jointing and testing, complete all as specified and as directed of the following cross sectional area :-
24(a) 10 Sqmm to 16 Sqmm 2/3½/4 Core
25(b) 25 Sqmm to 50 Sqmm 3½/4 Core
26(c) 70 Sqmm to 150 Sqmm 3½ Core
27(d) 185 Sqmm to 240 Sqmm 3½ Core
28(e) 300 Sqmm to 400 Sqmm 3½ Core
29S&F in repairs of MCCB, 630 Amps, 4 pole, 50 KA, with microprocessor based release with electronic Sg (LSIg) protection unit, ICS=100% of Icu with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1 , internal battery, communication port, inbuilt USB port for software diagnosis, all accessories incl taking down existing MCCB complete all as specified and directed.
30S&F in repairs of MCCB, 400 Amps, 4 pole, 50 KA, with microprocessor based release with electronic Sg (LSIg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1 , internal battery, communication port, inbuilt USB port for software diagnosis, all accessories incl taking down existing MCCB complete all as specified and directed.
31S&F in repairs of MCCB 4 Pole, 415 V, 320 Amps with adjustable type, breaking capacity 36 KA, Ics=100% of Icu with Copper spreader incl taking down existing MCCB complete all as specified and directed
32S&F in repairs of MCCB 4 Pole, 415 V, 250 Amps with adjustable type, breaking capacity 36 KA, Ics=100% of Icu with Copper spreader incl taking down existing MCCB complete all as specified and directed
33S&F in repairs of MCCB 4 Pole, 415 V, 200 Amps with adjustable type, breaking capacity 36 KA, Ics=100% of Icu with Copper spreader incl taking down existing MCCB complete all as specified and directed
34S&F in repairs of MCCB 4 Pole, 415 V, 160 Amps with adjustable type, breaking capacity 36 KA, Ics=100% of Icu with Copper spreader incl taking down existing MCCB complete all as specified and directed
35S&F in repairs of MCCB 4 Pole, 415 V, 125 Amps with adjustable type, breaking capacity 25 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
36S&F in repairs of MCCB 4 Pole, 415 V, 100 Amps with adjustable type, breaking capacity 25 KA, ICS=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
37S&F in repairs of MCCB 4 Pole, 415 V, 63 Amps with adjustable type, breaking capacity 18 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
38Note for item No. 13 to 21 :-(i) MCCB Should be calibrated at 50°C for accurate performance in higher ambient.(ii) Over load Protection of MCCB should be adjustable 63-100% of nominal Current.(iii) Short Circuit Protection of MCCB shall be adjustable 6 to 10 times in nominal current.(iv) Neutral Protection of MCCB Shall be adjustable to OFF/50% & 100%.
39Supply and fixing 80 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor incl taking down of old unserviceable GI pipe complete all as specified and as directed by the Engineer-in-Charge.
40Supply and fixing 100 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor incl taking down of old unserviceable GI pipe complete all as specified and as directed by the Engineer-in-Charge.
41S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
42(a) 10 Sqmm to 16 Sqmm, 4 core
43(b) 25 Sqmm to 50 sqmm 3.5/4 core
44(c) 70 sqmm to 150 sqmm, 3.5 core
45(d) 185 sqmm to 240 sqmm, 3.5 core
46(d) 300 sqmm to 400 sqmm, 3.5 core
47S&F Cable Route Indicator made out of Cast Iron plate 80 mm dia fixed with MS angle iron 40x40x6mm having 60 Cm long showing MES LT Cable Size with voltage with two coats of synthetic enamel paint in blue colour over one coat of primer necessary Earth Work and Cement Concrete 1:2:4 (20mm graded crushed stone aggregates) Block of size 20x20x20 Cm including Taking out Unserviceable Cable Route Indicator, complete all as specified and as directed.
48Material & Labour for PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
49Dismantling/ Disconnecting electric connection of underground LT, XLPE Cable, 1100 volts upto 35 to 400 Sqmm from both sides and locating the fault in LT cable with fault locating machine in the entire length complete testing after reconnecting and commissioning of cable complete all as specified and as directed. Note : The work will be executed after obtaining proper shutdown from main power house liase with JE E/M.
50Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1500mm x 1500mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 500 Amps of adequuate size for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 600mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories:- Make : Star Electric & Engg Co/ CPRI approved.
51(a) Manual change over switch 315 Amps, 4 pole, 415 volts,opern execution type - 01 Nos.
52(b) MCCB adjustable type with thermal-magnetic releases of capacity 320 A, 4P, 360 KA with spreader terminals - 02 Nos(I/C)
53(c) MCCB adjustable type with thermal-magnetic releases of capacity 100 A, 4P, 25 KA with spreader terminals - 02 Nos(O/G)
54(d) MCCB adjustable type with thermal-magnetic releases of capacity 80 A, 4P, 25 KA with spreader terminals - 02 Nos(O/G)
55(e) MCCB adjustable type with thermal-magnetic releases of capacity 63 A, 4P, 18 KA with spreader terminals - 04 Nos(O/G)
56(f) Surge Protection Device 3P+N, 50 KA, 415 Volts, 50 Hz - 01 Nos.
57(g) Digital Ammeter with Selector Switch - 01 Nos.
58(h) Digital Voltmeter with Selector Switch - 01 Nos.
59(j) MCB SP 6 Amps, 10 KA - 3 Nos.
60(k) LED type indication lamp R Y B - 01 set.
61(l) Current Transformer Ratio 400/5A - 03 Nos
62Note :-(i) All incoming and outgoing cables, duly thimbled along with suitable size of brass cable glands, to be connected with accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of aluminium/copper strip.(iii) MCCB Should be calibrated at 50°C for accurate performance in higher ambient.(iv) Over load Protection of MCCB should be adjustable 63-100% of nominal Current.(v) Short Circuit Protection of MCCB shall be adjustable 6 to 10 times in nominal current.(vi) Neutral Protection of MCCB Shall be adjustable to OFF/50% & 100%.
63Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1400mm x 1400mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 500 Amps of adequuate size for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 600mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories:- Make : Star Electric & Engg Co/ CPRI approved.
64(a) Manual change over switch 315 Amps, 4 pole, 415 volts,opern execution type - 01 Nos.
65(b) MCCB adjustable type with thermal-magnetic releases of capacity 320 A, 4P, 36 KA with spreader terminals - 02 Nos(I/C)
66(c) MCCB adjustable type with thermal-magnetic releases of capacity 200A, 4P, 25 KA with spreader terminals - 02 Nos(O/G)
67(d) MCCB adjustable type with thermal-magnetic releases of capacity 100A, 4P, 25 KA with spreader terminals - 03 Nos(O/G)
68(e) MCCB adjustable type with thermal-magnetic releases of capacity 63A, TPN, 10 KA with spreader terminals - 02 Nos(O/G)
69(f) Surge Protection Device 3P+N, 50 KA, 415 Volts, 50 Hz - 01 Nos.
70(g) Digital Ammeter with Selector Switch - 01 Nos.
71(h) Digital Voltmeter with Selector Switch - 01 Nos.
72(j) MCB SP 6 Amps, 10 KA - 3 Nos.
73(k) LED type indication lamp R Y B - 01 set.
74(l) Current Transformer Ratio 400/5A - 03 Nos
75Note :-(i) All incoming and outgoing cables, duly thimbled along with suitable size of brass cable glands, to be connected with accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of aluminium/copper strip.(iii) MCCB Should be calibrated at 50°C for accurate performance in higher ambient.(iv) Over load Protection of MCCB should be adjustable 63-100% of nominal Current.(v) Short Circuit Protection of MCCB shall be adjustable 6 to 10 times in nominal current.(vi) Neutral Protection of MCCB Shall be adjustable to OFF/50% & 100%.
76Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
77Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57623163
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35.50 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Lt Cable & Switchgears And Lt Panels At East Gate, Mes Ib, Ecom, Aoi, Manekshaw House And Other Central Institutes Inside Vijay Durg Under Ge(Vd) Kolkata
Basic Detail
Tender No 8624/E8
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 30 Sep 2026
Submission Date 12 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 35.50 Lakhs
Tender Fee 500
EMD 71000
Exemption Not Available
Document List
9c0d61c9-2e39-43a6-9a97-c8cf1d693a36.html
BOQ_886092.xls
TENDERDOCUMENTS8624.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

9c0d61c9-2e39-43a6-9a97-c8cf1d693a36.html

xls

BOQ_886092.xls

pdf

TENDERDOCUMENTS8624.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer