Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57623151

Tender For Repair / Maintenance Of Water Supply System, Bore Well And Connected Works At Basant Nagar And Connected Area Under Ge Af Palam, Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
30 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
17 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Water Supply System, Bore Well And Connected Works At Basant Nagar And Connected Area Under Ge Af Palam, Delhi Cantt-10

BOQ

Name of Work:- REPAIR / MAINT OF WATER SUPPLY SYSTEM, BORE WELL AND CONNECTED WORKS AT BASANT NAGAR AND CONNECTED AREA UNDER GE AF PALAM, DELHI CANTT-10
Sl. No. Item Description
1Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth in loose/soft soil, getting out and leveling the bottom surface to required gradient for laying of water supply mains complete all as specified and directed by Engineer-in-Charge.
2Returning, filling in, including levelling watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
3Removal of surplus excavated soil to a distance not exc 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
4Taking up or down steel tubing and connections of size 15 mm bore dia including fittings complete all as specified and directed by Engineer-in-Charge.
5All as per srl item No 4 here-in-before but of size 20mm bore dia complete all as specified and directed by Engineer-in-Charge.
6All as per srl item No 4 here-in-before but of size 25mm bore dia complete all as specified and directed by Engineer-in-Charge.
7All as per srl item No 4 here-in-before but of size 40mm bore dia complete all as specified and directed by Engineer-in-Charge.
8All as per srl item No 4 here-in-before but of size 50mm bore dia complete all as specified and directed by Engineer-in-Charge.
9All as per srl item No 4 here-in-before but of size 80mm bore dia complete all as specified and directed by Engineer-in-Charge.
10Supply, laying & testing steel water tubing, medium grade, galvanised of size 15 mm bore dia, ISI marked with and including ISI marked GI fittings such as tees, bends, elbow, reducer, unions, clamps etc fixed on wall / laid in trench /roof (with proper clamping arrangements) complete all as specified and as directed by Engineer-in-Charge.
11All as per srl item No 10 here-in-before but size 20mm bore dia complete all as specified and directed by Engineer-in-Charge.
12All as per srl item No 10 here-in-before but size 25mm bore dia complete all as specified and directed by Engineer-in-Charge.
13All as per srl item No 10 here-in-before but size 40mm bore dia complete all as specified and directed by Engineer-in-Charge.
14All as per srl item No 10 here-in-before but size 50mm bore dia complete all as specified and directed by Engineer-in-Charge.
15All as per srl item No 10 here-in-before but size 80mm bore dia complete all as specified and directed by Engineer-in-Charge.
16Taking up or down cast iron/ ductile iron water mains, with spigot and socket ends including burning out lead joints and recovering lead of size 100mm bore dia complete all as specified and directed by Engineer-in-Charge.
17All as per item No 16 here-in-before but of size 150mm bore dia complete all as specified and directed by Engineer-in-Charge.
18Supplying, laying, jointing, testing cast iron pipe with spigot and socketed ends centrifugally cast, class LA, including rubber gasket/ tyton/ lead joints conforming to IS-1536-1976 laid in trenches of the 100mm bore pipe complete all as specified and directed by Engineer-in-Charge.
19All as per srl item No 18 here-in-before but of size 150mm bore dia complete all as specified and directed by Engineer-in-Charge.
20M&L for 100 mm ductile iron pipe with spigot and socketed ends, centrifugally cast, class k-9 (IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc complete all as specified and directed by Engineer-in-Charge.
21M&L for 150 mm ductile iron pipe with spigot and socketed ends, centrifugally cast, class k-9 (IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc complete all as specified and directed by Engineer-in-Charge.
22Material & labour for CI special fittings of any size, any type ISI marked as required at site such as bends (any type, radius and angle), Taper any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, \\"Y\\" junction, double branch, cross (all socket or socket and spigot), collar, caps and plugs upto 150mm bore etc. complete all as specified and directed by Engineer-in-Charge.
23M&L for DI specials such as tees, bends, collars of any sizes and radius, tapers, tail pieces caps and plug upto 200 mm bore dia complete all as specified and as directed by Engr-in-Charge.
24Supply and fixing in replacement of unserviceable GI fittings such as reducers, tee, elbow, socket, nipple, plug, reducer elbow, reducer socket, union and other connected accessories of size 15 mm to 80 mm bore dia complete all as specified and as directed by Engineer-in-charge.
25Supply only bib tap high prssure of PTMT with epoxy coated screwed for iron pipe and fixed of size 15mm complete all as specified and as directed by Engineer-in-charge.
26Supply only bib tap high prssure of PTMT with epoxy coated screwed for iron pipe and fixed of size 20mm complete all as specified and as directed by Engineer-in-charge.
27Cutting existing galvanised iron pipe 15mm bore in position for insertion of new pipe/tees, branches etc. complete all as specified and as directed by Engineer-in-charge.
28Cutting existing galvanised iron pipe 20mm bore in position for insertion of new pipe/tees, branches etc. complete all as specified and as directed by Engineer-in-charge.
29Cutting existing galvanised iron pipe 25mm bore in position for insertion of new pipe/tees, branches etc. complete all as specified and as directed by Engineer-in-charge.
30Cutting existing galvanised iron pipe 40mm bore in position for insertion of new pipe/tees, branches etc. complete all as specified and as directed by Engineer-in-charge.
31Cutting existing galvanised iron pipe 50mm bore in position for insertion of new pipe/tees, branches etc. complete all as specified and as directed by Engineer-in-charge.
32Fabricate, supply & fixing stainless steel spindle and nut suitable for 200mm dia sluice valve complete with stainless steel nut and threading as per sample complete all as specified and as directed by Engineer-in-charge.
33Fabricate, supply & fixing stainless steel spindle and nut suitable for 150mm dia sluice valve complete with stainless steel nut and threading as per sample complete all as specified and as directed by Engineer-in-charge.
34Fabricate, supply & fixing stainless steel spindle and nut suitable for 100mm dia sluice valve complete with stainless steel nut and threading as per sample complete all as specified and as directed by Engineer-in-charge.
35Fabricate, supply & fixing stainless steel spindle and nut suitable for 80mm dia sluice valve complete with stainless steel nut and threading as per sample complete all as specified and as directed by Engineer-in-charge.
36Dismantling PVC water tanks of 500 Ltrs capacity and removing from the site to store complete all as specified and as directed by Engineer-in-charge.
37Dismantling PVC water tanks of 1000 Ltrs capacity and removing from the site to store complete all as specified and as directed by Engineer-in-charge.
38Supply & fixing rotational moulded polythene water storage tank three layered of 500 litre capacity (cylindrical vertical with closed top) including all necessary GI fittings complete all as specified and as directed by Engineer-in-charge. Note- (1) The cost of GI pipe required to be measured & paid seperately
39Supply & fixing rotational moulded polythene water storage tank three layered of 1000 litre capacity (cylindrical vertical with closed top) including all necessary GI fittings complete all as specified and as directed by Engineer-in-charge. Note- (1) The cost of GI pipe required to be measured & paid seperately
40Supply of PTFE thread seal tape (Teflon Tape), 12mm wide × 10m long (minimum), suitable for sealing threaded joints of GI pipes, elbows, tees, sockets, unions, valves and other screwed fittings complete all as specified and as directed by the Engineer-in-Charge.
41M&L for replacement for run lead joints for CI/DI pipe 100mm bore dia spigot & soketed/CI fittings including all jointing material required at site complete all as specified and directed by Engineer-in-Charge.
42M&L for replacement for run lead joints for CI/DI pipe 150mm bore dia spigot & soketed/CI fittings including all jointing material required at site complete all as specified and directed by Engineer-in-Charge.
43S&F in replacement gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipe or for union and fixed complete for size 50mm bore dia complete including taking up or down old unserviceable gate valve of 50mm bore dia complete all as specified and as directed by Engineer-in-Charge.
44All as per item No 43 here-in-before but of size 40mm bore dia complete all as specified and directed by Engineer-in-Charge.
45All as per item No 43 here-in-before but of size 25mm bore dia complete all as specified and directed by Engineer-in-Charge.
46All as per item No 43 here-in-before but of size 20mm bore dia complete all as specified and directed by Engineer-in-Charge.
47All as per item No 43 here-in-before but of size 15 mm bore dia complete all as specified and directed by Engineer-in-Charge.
48S&F in replacement including jointing and testing of cast iron sluice valve, class PN-1.6, ISI marked, flanged ends drilled having stainless steel /brass spindle with cast iron wheel at top complete with nuts, bolts,washers and gaskets including taking out old unserviceable sluice valve for the 80mm bore size complete all as specified and directed by Engr-in-charge.
49All as per srl item No 48 here-in-before but of size 100mm bore dia complete all as specified and directed by Engineer-in-Charge.
50All as per srl item No 48 here-in-before but of size 150mm bore dia complete all as specified and directed by Engineer-in-Charge.
51All as per srl item No 48 here-in-before but of size 200mm bore dia complete all as specified and directed by Engineer-in-Charge.
52Labour only for servicing of 1.5 TR split type air conditioner by spray jet cleaning of indoor and outdoor units, including cleaning of air filters, evaporator coil, condenser coil, drain tray and condensate drain pipe, checking and tightening of electrical connections, checking of electronic controls, thermostat and overall functioning of the unit, testing and commissioning by a highly skilled technician with helper, complete all as recommended by the OEM and as specified and directed by the Engineer-in-Charge.
53Supply and fixing in replacement of dual capacitor of suitable rating (50+6 µF or 55+6 µF, as recommended by the OEM), suitable for 1.5 TR capacity split/window air conditioner, including disconnecting the existing capacitor, making all electrical connections, testing and commissioning to ensure satisfactory operation of the air conditioner complete all as specified and as directed by the Engineer-in-Charge. Make:- Usha / Asian / Tibcon / EPCOS.
54Supply and fixing in replacement of condenser fan blade (propeller type) of suitable size, material and pitch, compatible with the existing condenser fan motor of 1.5 TR split type air conditioner, including dismantling of the unserviceable fan blade, balancing, alignment, tightening of fasteners, testing and commissioning for smooth and vibration-free operation complete all as specified and as directed by the Engineer-in-Charge.
55Supply and fixing in replacement of indoor blower wheel (cross-flow fan) suitable for 1.5 TR split type air conditioner, including dismantling of the unserviceable blower wheel, fixing on the existing blower motor, alignment, balancing, testing and commissioning complete all as specified and as directed by the Engineer-in-Charge.
56Supply and fixing in replacement of indoor blower motor, suitable and compatible with the existing make, model and capacity of 1.5 TR split type air conditioner, complete with mounting brackets, rubber bushes, coupling and all connected accessories, including dismantling of the unserviceable motor, making all electrical and mechanical connections, testing and commissioning to ensure smooth and satisfactory operation of the air conditioner complete all as specified and as directed by the Engineer-in-Charge.
57Supply and fixing in replacement of outdoor condenser fan motor, suitable and compatible with the existing make, model and capacity of 1.5 TR split type air conditioner, complete with mounting hardware and all connected accessories, including dismantling of the unserviceable motor, making all electrical and mechanical connections, testing and commissioning to ensure smooth and satisfactory operation of the air conditioner complete all as specified and as directed by the Engineer-in-Charge.
58Supply and fixing in replacement of copper condenser coil suitable for 1.5 TR split air conditioner, complete with brazing/welding, replacement of filter drier (if required), pressure testing with dry nitrogen, leak testing, evacuation), making all necessary connections, testing and commissioning to ensure satisfactory operation of the air conditioner, complete all as specified and directed by the Engineer-in-Charge.
59Taking out old perished insulation and M&L for insulating the suction and discharge copper tubing from indoor unit to outdoor unit of split type ACs of capacity 1.5 TR capacity with neoprene foam sleeves including sealing by applying adhesive tape of brown or white colour to avoid minimum contact with atmosphere complete all as specified and as directed by Engr-in-Charge.
60Taking out unserviceable suction and discharge copper tubing and providing and laying replacement copper tubing of sizes 1/2 inch OD (suction line) and 1/4 inch OD (liquid/discharge line), suitable for 1.5 TR split type air conditioner, complete with brazing/silver soldering, necessary fittings, leak testing, pressure testing, evacuation of the system and making the refrigerant circuit ready for gas charging, complete all as specified and directed by the Engineer-in-Charge.Note:- The suction and liquid/discharge copper tubing shall be measured together as one running metre.
61Supply and fixing PVC flexible drain pipe of suitable size (10mm, 16mm, 28mm, 32 mm and 40mm) for condensate drainage of split/window air conditioners, complete with couplers, clamps, lock nuts, saddles, pipe clips, nylon cable ties (250mm and 300mm), supports and all other fixing accessories complete all as specified and as directed by the Engineer-in-Charge.
62Supply and fixing in replacement of indoor unit complete, suitable and compatible with the existing make, model, refrigerant and capacity of 1.5 TR split air conditioner, including evaporator coil, blower assembly, air filters, PCB/control unit, display panel, swing motor, remote receiver, electrical interconnections, testing and commissioning, ensuring satisfactory operation with the existing outdoor unit, complete all as specified and directed by the Engineer-in-Charge. Make: Voltas/LG/Hitachi
63Supply and fixing in replacement of outdoor unit complete, suitable and compatible with the existing make, model, refrigerant and capacity of 1.5 TR split air conditioner, complete with compressor, condenser coil, condenser fan motor with fan blade, electrical control box, refrigerant charge and all factory-fitted accessories, including dismantling of the existing outdoor unit, making all electrical and refrigerant pipe connections, testing, commissioning and ensuring satisfactory operation of the air conditioner, complete all as specified and directed by the Engineer-in-Charge. Make:- Voltas/LG/Hitachi
64Supply and filling of refrigerant gas (R-22/R-32/R-410A, as applicable and recommended by the OEM) in the existing 1.5 TR split air conditioner, including checking for leakage, pressure testing, evacuation of the refrigeration system, charging the required quantity of refrigerant gas, testing and commissioning to ensure satisfactory operation of the air conditioner, complete all as specified and directed by the Engineer-in-Charge.
65Supply and fixing in replacement original (OEM) wireless remote controller suitable for existing 1.5 TR split type air conditioner of the same make and compatible model, complete with batteries, programming, testing and commissioning, ensuring satisfactory operation of the air conditioner, complete all as specified and directed by the Engineer-in-Charge.
66Material and labour for construction of valve pit chamber having internal dimension 120cm x 120cm x 120 cm (internal height) using 15cm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundation, 15mm thick rendering with CM (1:4), all around, brick work in CM (1:6) and PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS sheet cover with locking arrangement with and including 50mm pad lock with double key arrangement, MS frame made out of 40mm x 40mm x 6mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of metal primer including necessary excavation in any type of soil, returning/ filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition / dismantling of existing valve chamber complete all as specified and directed by Engineer-in-Charge.
67Material and labour for construction of valve pit chamber having internal dimension 90cm x 90cm x 90cm (internal height) using 15cm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundation, 15mm thick rendering with CM (1:4), all around, brick work in CM (1:6) and PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS sheet cover with locking arrangement with and including 50 mm pad lock with double key arrangement, MS frame made out of 40mm x 40mm x 6 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of metal primer including necessary excavation in any type of soil, returning/ filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition / dismantling of existing valve chamber complete all as specified and as directed by Engineer-in-Charge.
68M&L for augering of holes in true horizontal position under road (by trench less method) by means of mechanical rig covering in route up to 1.5 mtr deep and not exceeding 30mtr long for passing the water pipe lines of up to 150mm bore complete all as specified and directed by Engineer-in-Charge.
69M&L for well cap in replacement with housing clamp for upto 300 mm dia bore pipe in two pieces having 80 mm dia hole in centre with external bracket of flat iron of size 100mm x 6mm thick complete with nuts, bolts and washers etc including welding and painting etc including taking down old unserviceable well cap and depositing to MES store yard complete all as specified and directed by Engineer-in-Charge.
70Material & Labour for cleaning internal portion of stone masonry/RCC underground/ Semi Underground water storage sump of capacity upto 50,000 gallons including following process:-(a) Mechanised removal of all remaining dirty water by high capacity submersible pump set(b) Removal of sludge by Vacuum operated German pump(c) Cleaning of walls, ceiling and bottom of tank by German made high pressure rotary jet 120 bar pressure(d) Removal of all dirty particles by industrial wet vacuum cleaner leaving the tank 99.9 % physically cleaned(e) Sterlization of tank by Eco-friendly bio-degradable and highly effective against all pathogens(f) Sterlization of tank atmosphere by industrial UV radiator leaving the tank completely sterlized by specilized method complete all as specified and as directed by Engr-in-Charge.Note:- The item rate includes the cost of weather proof painting of details on tank such as (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank.
71All as per srl item No 70 above here-in-before but for Over Head Tank upto 45 mtr staging (Height of OH Tank) of capacity 01 Lakh Gallons complete all as specified and as directed by Engr-in-charge.Note :- Rates for providing the scaffolding and necessary pumping equipment shall be deemed to be included in the unit item rate.
72All as per srl item No 70 above here-in-before but for Over Head Tank upto 45 mtr staging (Height of OH Tank) of capacity upto 50,000 Gallons complete all as specified and as directed by Engr-in-charge.Note :- Rates for providing the scaffolding and necessary pumping equipment shall be deemed to be included the unit item rate.
73Material and labour in replacement of insulated rubber chequered sheet of size 2.00 mtr x 1.00 mtr not less than 19mm thick complete all as specified and directed by Engr-in-charge.
74Supply and fixing in replacement of CI NRV of 100mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete all as specified and directed by Engr-in-charge.
75Supply and fixing in replacement of CI NRV of 150 mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete all as specified and directed by Engr-in-charge.
76Supply & fixing in replacement of valve pit cover/ Sump manhole cover/ pressure pump shade etc made out of MS frame 40mm x 40mm x 6mm thick angle iron with and including 6/8 mm thick MS top cover with locking arrangement and painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
77Supply only CDD 5000 (two components chlorine dioxide powder) (CAS No 10049-04-4 conforming to ISO9001-2015) white in colour highly soluble in water, 99.9% effective against water borne micro organisms disinfectant for chlorination of water complete all as specified and directed by Engr-in-Charge. Note:- Receipt Voucher of material shall be produced during the submission of RAR.
78Supply and fixing ceiling fans complete with blades, down rods, modular electronic regulator and accessories, 230 V, 1200mm sweep or 48\\" minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC), including connecting up with three core flexible copper conductor cable of suitable size from ceiling complete all as specified as directed. Make:- Havells/Usha/Cromption/Bajaj
79Disconnecting existing defective electric motor of any make upto 30 to 50 HP from electric mains by isolating the naked connections, removing from foundation by unscrewing the nuts, bolts etc, dis-couple from pump etc opening of motor for inspection in presence of Engr-in-Charge & carry out minor repairs at site re-assembling the motor and pump after repair, refixing in position re-connecting same as prior to removing from foundation including replacement of nuts, bolts, washers if necessiates of suitable size, testing and commissioning complete all as specified and directed. Note :- (a) Replacement of all parts of motor (minor and major) shall be deemed to be included in this item rate. (b) In case of repairs not possible at site, the motor and pump shall be shifted to workshop of authorised service centre and cost of shifting to wksp and back to site included in the item rates. (c) The cost of replacement of motor winding shall be measured and paid separately under respective item.
80All as per item No. 79 above but capacity 15 to 25HP of any type & size complete all as specified and directed by Engr-in-Charge.
81Taking out old unserviceable/burnt copper winding of motors capacity up to 30 to 50 HP and material and labour for rewinding of electric motor of capacity up to 30 to 50 HP, 3 Phase with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor slots, all winding/ insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge complete all as specified and as directed by Engr-in-Charge. Note:- Defective motor shall be obtained from ser item No. 79 here in above.
82All as per item No 81 here in before but capacity 15 to 25 HP, three phase, of any type & size complete all as specified and directed by Engr-in-Charge. Note:- Defective motor shall be obtained from ser item No. here in above.
83M&L for dismantling and taking out defective parts of centrifugal pump set coupled with motor of capacity 30 to 50 HP any type any stage and taken to authorised workshop and refixing the same to its original position after repair and making it serviceable completely by repairing/ replacement of unserviceable parts (major and minor) complete all as specified and as directed by Engineer-in-Charge.Note: (i) Cost of transport to civil workshop and back to site shall be included in the item rate.(ii) Cost for repair/ replacement of spare parts (minor and major) shall be included in the item rate.
84All as per item No 83 here in before but capacity of motor 15 to 25 HP, three phase, of any type & size complete all as specified and as directed by Engineer-in-Charge.
85Disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts and taking out the submersible pump set upto 10 HP (including motor) from the borewell including column pipes, and submersible cable, disconnecting the pump and motor opening the pump and motor to locate the faults in presence of Engineer-in-Charge, and carry out necessary repairs as directed including transporting to authorised workshop, re-assembling the same after repair, taking down to the well, including column pipe of any dia, 10 ft long, and submersible cable, which have been taken out, re-connecting all electrical and water connections as per existing complete testing and commissioning including new packing materials, nuts, bolts, washers of suitable size complete all as specified and as directed. Note :- (a) Replacement of all unserviceable parts of pump and motor shall be deemed to be included this item rate. (b) In case of repairs not possible at site, the motor and pump shall be shifted to authorised workshop and cost of shifting to workshop and back to site included in the item rates. (c) replacement of motor winding shall be measured and paid separately under respective item.
86Taking out old unserviceable/burnt winding from the submersible 3 phase motors up to 10 HP capacity and M& L for rewindinig with insulated winding wire as per existing gauge complete including transportation to and fro and as approved by Engr-in Charge and testing after repair complete all as specified and as directed.
87Supply and fixing in replacement column pipe 50mm dia bore made of meduim grade GI pipe, 10 feet length both ends flanged & drilled including cutting of grooves for submersible cable and fabrication etc. complete all as specified and as directed by Engineer-in-Charge.
88Supply and fixing in replacement column pipe 80mm dia bore made of meduim grade GI pipe, 10 feet length both ends flanged & drilled including cutting of grooves for submersible cable and fabrication etc. complete all as specified and as directed by Engineer-in-Charge.
89Supply and fixing 24-hour Analog Auto Timer Switch suitable for automatic operation of borewell pump, complete with minimum 16A, 240V AC rating, DIN rail/wall mounting type, manual ON/AUTO/OFF override, daily programmable switching, complete with all fixing accessories, internal connections, testing and commissioning, complete all as specified and directed by the Engineer-in-Charge.
90Supply and fixing of single phase preventor VSP-2 / VSP-1 complete all as specified and directed by Engr-in-Charge. Make:- Minilac/ L&T/ Lagrand
91Disconnecting electrically on load change over switch of any type as per site requirement and supply & fixing and connecting change over switch 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material complere all as specified and directed.
92Disconnecting electrically on load change over switch of any type as per site requirement and supply & fixing and connecting change over switch 4 pole 250 Amp 440 volts conforming to relevant IS including all connecting and jointing material complere all as specified and directed.
93Disconnecting electrically, isolating the existing unserviceable MCCB of any make and capacity and Supply, fixing, connecting, testing and commissioning MCCB, 440 volts fixed in existinig panel including necessary modification for new MCCB, 250 amp capacity 4 pole breaking capacity 36 kA conforming to relevant IS including all joining and connecting material complete all as specified and as directed. Make:- Schnider /L&T/ Havells.
94All as per item No. 93 here in before but 200 Amps breaking capacity 36 kA, 4 pole complete all as specified and as directed by Engineer-in-Charge.
95All as per item No. 93 here in before but 125 Amps breaking capacity 25 kA, 3 pole complete all as specified and as directed by Engineer-in-Charge.
96All as per item No. 93 here in before but 125 Amps breaking capacity 16 kA, 4 pole complete all as specified and as directed by Engineer-in-Charge.
97All as per item No. 93 here in before but 100 Amps breaking capacity 25 kA, 3 pole complete all as specified and as directed by Engineer-in-Charge.
98All as per item No. 93 here in before but 25 to 100 Amps breaking capacity 16 KA, 3 pole complete all as specified and as directed by Engineer-in-Charge.
99Supply, connecting, testing and commissioning submersible cable with copper conductor, stranded of size 4 sqmm 3 core complete including taking out old unserviceable cable complete all as specified and as directed.
100All as per item No 99 here in before but 6 sqmm, 3 core complete all as specified and as directed by Engineer-in-Charge.
101Supply and fixing PVC copper conductor wire unsheathed FRLSH of size 4.00 sqmm single core multistranded complete all as specified and as directed by Engineer-in-Charge.
102Supply and fixing PVC copper conductor wire unsheathed FRLSH of size 2.50 sqmm single core multistranded complete all as specified and as directed by Engineer-in-Charge.
103Supply and fixing PVC copper conductor wire unsheathed FRLSH of size 1.50 sqmm single core multistranded complete all as specified and as directed by Engineer-in-Charge.
104Disconnecting and lifting out of existing submersible pump set of capacity up to 10 HP from borewell, along with column pipes of any diameter and submersible cable from any depth, for technical inspection in case of abnormal noise, vibration or operational malfunction, and lowering the same after inspection/repair, including reconnection of electrical and water connections, complete all as specified and directed by the Engineer-in-Charge.Note:- This item shall be applicable only where the comprehensive repair item is not applicable. No separate payment shall be admissible under this item where lifting and lowering operations are included in the rates of any repair item.
105Material & Labour for painting to existing centrifugal motor & pumping set complete including base frame with super enameled paint of existing colour coat by spray painting and writing of SM/MES No with white paint, 30 to 50 HP capacity complete all as specified and as directed by Engineer-in-Charge.
106All as per item No 105 above but 15 to 25 HP capacity complete all as specified and directed.
107M&L for repairs, servicing of liquid chlorine dosing system, any make, any type/capacity complete including replacement of chlorine dosing pipe upto 2.5 mtr length for each plant including servicing of motor, washing of chlorine tank with descaling agent and re-commissioning, testing of plant complete all as specified and directed.
108Supply and fixing in replacement sealed maintenance-free (SMF) / lead-acid battery, 12 Volts, 180 AH, of existing type and size, suitable for DG sets of capacities 15 KVA to 125 KVA, including initial charging (where applicable), supply and fixing of copper terminal connectors with petroleum jelly, testing and commissioning, complete all as specified and directed by the Engineer-in-Charge. Make:- Exide/Amaron.
109Material & Labour for painting to existing LT panels, indoor type installed at various pump houses with super enameled paint of approved colour on exposed surface including preparation of surfaces and applying primer coat complete all as specified and directed by Engineer-in-charge.
110All as per item No 109 above but borewell panels (out door type) complete all as specified and directed by Engineer-in-charge.
111Supply and fixing in replacement BI metallic (Bimettalic) over load relay of suitable current rating range (9-23 Amps, 24-42 Amps or 45-75 amp rating) compatable with the existing automatic motor starter including dismantling of defective relay, reconnection, adjustment of overload settings, testing and commissioning complete all as specified and directed by Engineer-in-charge. Make: Legrand/LT
112Supply and fixing for Amps meters 0 to 200 Amps, Digital type with selector switches, CTs etc complete all as specified and directed by Engineer-in-charge.
113Supply and fixing for volt meters 0 to 500 Volt, Digital type 415 volts with selector switches, CTs etc complete all as specified and directed by Engineer-in-charge.
114M&L for painting of water supply header of size 250mm dia with two coats of synthetic enamel paint with a suitable colour complete all as specified and as directed by Engineer-in-charge.
115M&L for chemical and bacteriological analysis and potability of water obtained from Delhi Jal Board & borewells from Sriram Test House/ MCD approved/ NABL approved micro engineering and testing lab and submitting the report in duplicate complete all as specified and as directed by Engineer-in-charge. Note:- The testing of water shall be carried out quarterly.
116M&L for cutting of road for laying of UG CI/DI/GI pipe after laying pipe making good damaged surfaces of road to match the adjoing existing surfaces using paste premix bituminous 50mm thick polymer based material over WBM 75mm thick including rolling work etc complete all as specified and as directed by Engineer-in-charge.
117Supply and fixing in replacement of unserviceable display board for showing details of pump houses with location as provided by Engineer -in-charge made out of PVC sheet Box of size 1.5mtr x 1mtr x 0.20 mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 nos LED tube light fittings 20 watts, connecting electrical supply to the frame with copper wire two core 1.5 Sqmm from nearby electric source including round steel pole minimum 12 feet long of suitable dia for erection on ground with PCC complete all as specified and as directed by Engineer-in-charge.
118M&L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in foundation, filling in mass concrete etc including necessary use and waste of form work and finishing the exposed surfaces fair and even complete all as specified and as directed by Engineer-in-charge.
119Supply and fixing in replacement power contactor of suitable rating (32 Amps, 40 Amps, 50–70 Amps or 70 Amps), 415 Volts AC, 3 Phase, compatible with the existing motor starter/control panel, equivalent to ML-1.5, ML-3, ML-4, MNX or HGS series as applicable, including taking down the unserviceable contactor, disconnecting and reconnecting all control and power wiring, tightening of terminals, testing, commissioning and satisfactory operation, complete all as specified and directed by the Engineer-in-Charge. Make:- L&T/ Legrand /Siemens /Schneider.
120Material and Labour in replacement CI foot valve flanged type including nuts, bolts, washers and rubber upto 150 mm dia conforming to IS-4038 complete all as specified and as directed by Engineer-in-Charge.
121Material and Labour in replacement CI foot valve flanged type including nuts, bolts, washers and rubber 100 mm dia conforming to IS-4038 complete all as specified and directed by Engineer-in-Charge.
122Supply and fixing in replacement fully automatic Star-Delta Starter, 415 Volts, 3 Phase, 50 Hz, with suitably rated contactors, timer, thermal overload relay matching the motor full-load current, MCCB/MCB, single phasing preventer, phase reversal protection, short-circuit protection, under-voltage protection, Auto/Manual selector switch, indicating lamps, housed in CRCA sheet steel enclosure, suitable for operation of 15 HP, 25 HP, 40 HP and 50 HP borewell motors, including disconnecting the existing starter, making all electrical connections, testing and commissioning complete all as specified and directed by the Engineer-in-Charge.
123Supply and fixing in replacement fully automatic Star-Delta Starter, 415 Volts, 3 Phase, 50 Hz, complete with suitably rated AC-3 duty main, star and delta contactors, electronic star-delta timer, thermal overload relay matching the motor full-load current, MCCB, single phasing preventer, phase reversal protection, short-circuit protection, under-voltage protection, Auto/Manual selector switch, ON/OFF push buttons, RYB phase indicating lamps, housed in CRCA sheet steel enclosure with powder-coated finish, suitable for operation of 415 Volts, 3 Phase submersible pump motors of capacity up to 10 HP having Star-Delta starting arrangement, including disconnecting the existing starter, making all incoming and outgoing electrical connections, testing, commissioning and ensuring satisfactory operation of the pump set, complete all as specified and directed by the Engineer-in-Charge.
124M&L for flushing of existing borewells of size upto 300mm dia, depth upto 200 mtr with drilling compressor including surging and flushing the bore at a pressure of 7 kg/ sqcm minimum 10 hrs, complete with compressed air and flushing the sand, mud etc from the bore well complete all as specified and directed by Engr-in-Charge. Note:- Disconnecting and lifting out of existing submersible pump set from borewell upto 10 HP capacity along with their column pipe and submerssible cable from borewell from any depth and lowering after flushing existing borewell shall be deemed to be included in the item rate. Note:- Log Book shall be maintained with location and machine number. Log Book shall be attached with RAR.
125S&F tyton joint (Mechanical Repair Coupling) suitable for existing 100mm dia pipe complete with stainless steel/MS body, EPDM rubber gasket, nuts, bolts and washers, including excavation as necessary, cutting and preparation of pipe ends, fixing, tightening, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
126All as per item No 125 here-in-before but of size 150 mm bore dia complete all as specified and as directed.
127M&L for fabrication of common base frame for centrifugal pump set up to 50 HP comprising pump and motor, fabricated from MS channel, angle iron, flat iron and MS plate conforming to Fe-290 Grade E165, including cutting, drilling, welding, gusset plates, stiffeners, foundation bolt holes, surface preparation, one coat of red oxide primer and two coats of synthetic enamel paint, complete including fixing in position and alignment, complete all as specified and directed by Engineer-in-Charge.
128Locate the any kind of fault in water pipe line of any size and any type by digging only with JCB along the length of any type of water pipe line and upto the depth from 1.5 to 3 mtr as required at site in any type of soil of water pipe line bottom to locate the exact pin point location of fault including rectification of fault with the help of plumber, returning and filling of same by tightening the union, replacing elbows, sockets, tees, nipple, checknut, lead jonits, flanged joints etc complete all as specified and as directed by Engg-in-charge. Note:- (a) Items required to replace shall be measured and paid seperately.
129Supply and fixing of wall mounting bracket for 1.5 TR Split Type Air Conditioner Outdoor Unit, fabricated from heavy-duty MS angle not less than (40mm × 40mm × 5mm), suitable to support outdoor unit up to 1.5 TR capacity, complete with epoxy/powder coated finish, anti-vibration rubber pads, GI/MS foundation bolts, anchor fasteners, nuts, bolts, washers and all necessary accessories for securely fixing the outdoor unit to brick/RCC wall, including drilling, making good disturbed surfaces, testing for stability and satisfactory performance, complete all as specified and as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57623151
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Water Supply System, Bore Well And Connected Works At Basant Nagar And Connected Area Under Ge Af Palam, Delhi Cantt-10
Basic Detail
Tender No 8026/A/T-68/E8
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 21 Sep 2026
Submission Date 12 Oct 2026
Open Date 19 Oct 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
8acce519-5c7b-44fc-bb48-d9fe934ab122.html
BOQ_885979.xls
tender.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

8acce519-5c7b-44fc-bb48-d9fe934ab122.html

xls

BOQ_885979.xls

pdf

tender.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders