Tender For Special Repair To Building No P-39 And P-40 (Old Cook House And Dining Hall) And Rewiring In Unit C Ing Area At 810 Cetc Purkazi
Tender Overview
Project Description
Tender for Special Repair To Building No P-39 And P-40 (Old Cook House And Dining Hall) And Rewiring In Unit C Ing Area At 810 Cetc Purkazi
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Sep-2026 | Revised BOQ Corrigendum | BOQ | 12-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness (below or above ground level) including removal of rubbish out side complex (MoD land), complete all as specified and directed. |
| 2 | Demolition of reinforced concrete any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | M&L for 75mm thick PCC 1:3:6 type C-1 (using 20 mm graded aggregate) as in plinth protection, floor etc, laid in panels not exc 1.80 sqm each and filled with mastic fillig of bituman and sand all specified, finished even and smooth without using extra cement complete all as specified and directed. |
| 4 | M&L 75mm thick plain cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base floor complete all as specified and directed. |
| 5 | M&L PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation of manholes, filling and mass concrete etc complete all as specified and directed |
| 6 | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in cills, coping, bed plates, bed blocks for hold fasts, apex stones and the like with plain fair faces including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed. |
| 7 | Demolition of Brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 8 | M&L for brick work in CM 1:6 using Sub class ‘B’ Bricks straight or curved on plan exc 6 m mean radius complete all as specified and directed. |
| 9 | M&L for brick work in CM 1:4 using Sub class ‘B’ Bricks straight or curved on plan any radius in half brick complete all as specified and directed. |
| 10 | M&L for precast reinforced cement concrete (1:2:4), type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs for manholes, kitchen platform etc and similar articles with plain faces, with plain fair faces, including chamfers, weathering, throating etc and setting in mortar complete with joints to match set in CM 1:6 complete all as specified and directed. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 12 | M&L for pre polished machine cut kota stone slab flooring 16-18mm thick with and including 100mm wide 16 to 18mm thick white marble border, laid over and including 15mm thick screed bed in cement mortar (1:6), set in neat grey cement slurry and jointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing with mirror finish complete all as specified and directed. |
| 13 | M&L pre polished kota stone slab with uniform texture of 16-18 mm thick in trader of steps (to be flushed and provided with three Nos of grooves at the end on each step), riser of steps, skirting, dado and pillars in one single piece (size decided by Engineer-in-Charge) laid over and including cement screed 10mm thick in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, bevelled edge of corner etc complete all as specified and directed. |
| 14 | M&L for mirror polishing to existing marble/granite/Kota stone/stone work where ever required including to give high gloss finish complete all as specified and directed. |
| 15 | M&L for glazed ceramic colour joint free tiles in vertical surface size 450x 350x7mm/450x 300 x7mm/ 600x300mmx7mm thick as required set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM 1:4 complete all as specified and directed. |
| 16 | M&L for Non-skid Ceramic joint free colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 17 | M&L Udaipur green (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms over and incl 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding of edges where required all as specified and directed. |
| 18 | M&L 16-18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms over and incl 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl molding of edges where required complete all as specified and directed. |
| 19 | S&F mild steel TMT reinforcement bars for stirupps etc 6 mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 20 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 21 | Taking down Shutters of any description exc 1 sq. m but not exc 2 Sqm each complete all as specified and directed. |
| 22 | Taking down chowkhat or frames with shutters (without taking off shutter from the frame) not exc 1.5 Sqm each including necessary cutting holes and making good using PCC (1:2:4) Ty B-0. complete all as specified and directed. |
| 23 | Taking down chowkhat or frames with shutters (without taking off shutter from the frame) exc 1.5 Sqm but n exc 4 Sqm each including necessary cutting holes and making good using PCC (1:2:4) Ty B-0 complete all as specified and directed. |
| 24 | S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, grill, gating, holdfast, guard bar, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe-290 (Gde E 165) complete all as specified and directed. |
| 25 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 26 | S&F 30 mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 27 | S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 28 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 29 | S&F factory made Steel windows with side hung shutters incl box type hinges with steel handles and steel peg stay complete with glazing bars dovetailed or welded complete all as specified and directed. |
| 30 | Ditto all as above but without glazing bar |
| 31 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 32 | S&F 3.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 33 | S&F Stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tack/galvanised wire staple complete all as specified and directed. |
| 34 | M&L for preparation of newly surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 35 | M&L for preparation of old painted surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 36 | S&F 150 mm Mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed. |
| 37 | S&F for 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 38 | S&F 200mmMild steel, semi-barrel tower bolt, open cover, with sheet pressed barrel, stove enamelled black with bright bolt and fixed complete all as specified and directed. |
| 39 | S&F 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed. |
| 40 | S&F in repairs MS ordinary rat tail rod pattern springs including roller and roller plate,300mm long complete all as specified and as directed. |
| 41 | Taking down cement plaster (including tiles, if necessary) of any description on Brick walls including racking out Joints, hacking for key scrubbing down with water etc. |
| 42 | M&L for rendering 15 mm Thick in CM (1:6) on Brick surfaces, rendering is to be finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 43 | M&L for rendering 15mm thick consisting of two coats, top layer 5 mm thick in CM 1:4 (mixed with WPC) over 10mm thick layer in CM 1:6, on fair faces of brick work finished even & fair complete all as specified and directed. Note:- WPC shall be measured & paid separately. |
| 44 | M&L for rendering 5 mm Thick in CM (1:3) on Brick or concrete surfaces, rendering is to be finished even and smooth (without using extra lime or cement) all as specified and directed. |
| 45 | Supply only liquid water proofing compound complete all as specified and directed. |
| 46 | M&L for complete removal of existing treatment on surfaces of walls by scrapping down with mechanical grinder on old walls as per the specification of manufacturers instructions of paints/OBD complete all as specified and directed. |
| 47 | M&L for complete removal of existing treatment on surfaces of ceilings by scrapping down with mechanical grinder on old ceilings as per the specification of manufacturers instructions of white washing/paints/OBD complete all as specified and directed. |
| 48 | M&L for preparation of newly or old treated plastered surfaces of walls applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 49 | M&L preparation of newly or old treated plastered surfaces of walls applying with 2 coat of oil bound distemper over a coat of 1mm thick putty on wall, complete all as specified and directed. |
| 50 | M&L preparation of old treated plastered surfaces of walls applying with two coat of white washing on walls, complete all as specified and directed. |
| 51 | M&L preparation of newly treated plastered surfaces of ceilings applying with three coat of white washing on ceilings, complete all as specified and directed. |
| 52 | M&L preparation new steel surface over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 53 | M&L preparation old steel surface over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 54 | S&F in repairs of 25 mm dia steel complete fancy type CP curtain rod with and including steel type brackets, stops, of suitable size & side caps etc. complete all as specified and directed. Make: Locally available Ist class quality duly approved by Engr-in-Charge and GE. |
| 55 | Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 56 | Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 57 | S&F 15mm bore GI steel tubing medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 58 | S&F 20mm bore GI steel tubing medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 59 | Cutting chases in brick walls, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 60 | S&F vitreous china squatting pan (Orissa pattern) long pan including connection to trap, and to flushing pipe, anti-syphonage pipe etc incl making good to floor fixed in repair size 580x440mm white with integral footrest with 'P' or 'S' trap complete (excluding flushing cistern and flush) complete all as specified and directed. |
| 61 | S&F in repair PVC valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float, handle and PVC. 32 mm dia flush pipe including brackets of 10 Ltr capacity complete all as specified and directed. |
| 62 | S&F in repair vitreous china wash hand basin, white, flat back type, size 550x400mm, excluding taps, chain and plug and porcelain stopper but including waste coupling, exclusive of fixing of supply and waste pipe fixing complete all as specified and directed. |
| 63 | S&F in repairs, 15mm dia bore brass CP fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 64 | S&F in repair for stop/angle cock, fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15mm bore pipe complete all as specified and directed. |
| 65 | S&F in repair for fancy type,chromium plated stop/Angle cock, with long shank and cup (concealed type) chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15mm bore pipe. |
| 66 | S&F in repair PVC connection 450mm long with 2 Nos brass check nuts suitable for 15mm bore of pipe with washer complete all as specified and directed. |
| 67 | M&L for Flush pipe of polyethylene of high density or PVC 32 mm dia complete all as specified and directed. |
| 68 | S&F in repair looking mirror 600x450x5mm thick with aluminium channel frame, selected quality mounted on 6 mm thick commercial ply wood back and fixed with chromium plated brass screws and cup washers complete all as specified and directed. |
| 69 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed |
| 70 | S&F chromium plated fancy type 15mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 71 | S&F for Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) complete all as specified and directed. |
| 72 | S&F for 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 73 | S&F for 110mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 74 | S&F for 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 75 | S&F for 75mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 76 | S&F PVC (SWR) floor trap, plain with grating cover including jointing with solvent cement complete all as specified and directed. |
| 77 | Dismantling of PVC/RCC water tanks of 2000 Ltr capacity and removing complete all as specified and directed. |
| 78 | M&L 2000 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl 20mm PTMT ball valve (Ball valve make:- Prayag) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed. |
| 79 | Dismantling of PVC/RCC water tanks of 500 Ltr capacity and removing complete all as specified and directed. |
| 80 | M&L 500 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl 20mm PTMT ball valve (Ball valve make : Prayag) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 81 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 82 | M&L rendering 15mm thick in CM 1:4 mixed with WPC on roof surfaces finished even & smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid separately. |
| 83 | M&L 25mm thick PCC type B-0, 1:2:4 (12.5mm graded stone aggregates) as in floor/roof surface as levelling course complete all as specified and directed. |
| 84 | M&L for roof treatment with polymeric membrane (APP based) with non woven polyester mat as reinforcement with following:-(a) M&L for providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface.(b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight of 3.5 Kg/Sqm with non woven polyster fiber as reinforcement on primed surface by torch application with side over laps & joints over laps etc as per manufacturers instruction.(c) M&L for finishing of top surface by two coat of aluminium paint over a coat of blown bitumen 85/25 grade @ 1.2 Kg/Sqm grouted all as specified and as per manufacturers instruction. |
| 85 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregrate) as in bed to 150mm internal dia RCC/ SGSW drain pipes including packing under and haunching against sides of pipes after they are laid and tested complete all as specified and directed. |
| 86 | M&L for brick work with old size sub class ‘B’ bricks in cement mortar (1:4), straight or curved on plan exc 6m mean radius built complete all as specified and directed |
| 87 | M&L for rendering 15mm thick in cement mortar (1:3) mixed with water proofing liquid on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 88 | M&L for Reinforced concrete pipes, class NP2, with collars laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed. |
| 89 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying/taking up/taking down of UG cable/ water pipes of any size and typeetc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as specified and directed |
| 90 | Returning filling in with excavated soil including spreading, leveling, watering & well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 91 | Removing excavated surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 92 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60, with grey cement and pigment, complete all as specified and directed. |
| 93 | Supply and laying sand (25 mm thickness) for cushioning to interlocking paver block complete all as specified and directed. |
| 94 | M&L Cement concrete type B-1 (1:2:4) (using 20 mm graded crushed stone agg) in roof kerbs or mud stop rounded or chamfered on edge, coping etc complete all as specified and directed |
| 95 | Dismantling and taking down carefully U/S copper/aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified & directed. |
| 96 | Dismantling and taking down carefully sub-main wiring/ service wire of any size including wooden batten etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed. |
| 97 | Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed. |
| 98 | M&L for point wiring with 1.5 sq mm PVC insulated, unsheathed, stranded copper conductor (FRLS-H) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked concealed conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface,provision of GI/Pressed steel terminal switch box with plastic laminated sheet 3 mm thick fixed with brass screw and washers along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS-H) as earth wire connected with main common earth dolly complete all as specified and directed for the following :-One light/fan/bell/exhaust fan point controlled by one, one-way non modular switch 5/6 Amp complete all specified and directed. |
| 99 | One 3pin/5pin 5/6 Amps socket out let on same board controlled by one, one-way non modular switch complete all specified and directed. |
| 100 | One 3pin/5pin 5/6 Amps socket out let on independent board controlled by one, one-way non modular switch complete all specified and directed. |
| 101 | All as per item No 98 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLS but unsheathed single core for16 Amps power point on independent board and 2.5 sqmm FRLS cable as earthwire complete all specified and directed. |
| 102 | S&F switch piano flush type white finish 5/6 Amps, single pole one way, 230 volts, 50 hz complete all as specified & directed. |
| 103 | S &F socket out let 2 pin 5/6 Amps & 3 pin 5/6 Amps flush type, 230 volts, 50 hz complete all specified and directed |
| 104 | S&F switch piano flush type white finish 15/16 Amps single pole one way, 230 volts, 50 hz complete all specified and directed |
| 105 | S &F socket out let 5 pin 15/16 Amps & 3 pin 5/6 Amps flush type, 230 volts, 50 hz complete all specified and directed |
| 106 | S&F fan regulator, stepped type, electronic (socket type),100 watt compatible with BLDC FAN complete all as specified and directed. |
| 107 | S&F lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed. |
| 108 | S&F LED Bulb 9 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for \\"B-22 type to fix on batten holder complete all as specified and directed. |
| 109 | M&L ceiling rose 3 terminal/PVC/polycarbonate, isolated body complete all specified and directed |
| 110 | S&F sheet metal enclosures with metal socket and plug top Single pole and neutral enclosure with a two pin and earth plug and socket complete ISI marked, 230/240 volts, 50 hz with one single pole MCB SP 25 Amps complete all specified and directed |
| 111 | S&F MCCB/MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with 200 Amps rated busbar minimum IP 43 degree of protection with built in copper bus bar of suitable size, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB/MCBs shall be measured and paid separately. |
| 112 | S&F sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 100 Amps rated busbar, minimum ingress protection of IP40 complete all specified and directed. |
| 113 | S&F MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.Note: MCBs should be of same make as of DB 8 way. |
| 114 | S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.Note: MCBs should be of same make as of VTPN 4 way and DB 8 way. |
| 115 | S&F MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz, Ics = 100% Icu with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed.Note: MCCB should be of same make as of VTPN 4 way. |
| 116 | S&F in replacement of old unserviceable LED T5 tube light fitting 20 watts full white and warm white dual with polycarbonate housing and polycarbonate diffuser with integrated electronic driver with all accessories including connecting up with PVC insulated and PVC sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. |
| 117 | S&F LED 25 watt Building security light fitting mounting type made out of one piece in pressure die-cast aluminium housing with high efficient LED as lighting source and PC Cover separate compartment for driver,including bracket clamp and fixing accessories complete with electronic driver and all accessories. The fitting shall IP 66 protection, duly prewired complete all as specified and directed. |
| 118 | S&F sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLS ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all specified and directed. (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length). |
| 119 | Ditto all as above but for 4 sqmm |
| 120 | S&F ceiling fans copper wounded with blades, down rods 230 V, 1200 mm sweep with remote control. Min air delivery 210 CFM with rating 6.00 BEE, star with brushless direct current motor (BLDC) complete all as specified and directed.Note: Old Ceiling fan to be deposited in MES store Yard. |
| 121 | S&F in repair Exhaust fan Steel body AC single phase 230/240 Volt of size 450 mm sweep, complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed sufaces of wall complete all specified and directed.Note: Old Exhaust fan to be deposited in MES store Yard. |
| 122 | S&F in replacement electric water heater with temp regulator, storage type steel body with stainless steel inner tank and heating element upto 1.5/ 2 KW capacity 25 litre, BEE 5 Star rated, ISI Marked, 240 V, 50 Hz complete with all accessories such as safety valve, thermostate, NRV, Hot and cold water connection pipe complete all specified and directedNote: Old Water heater to be deposited in MES store Yard. |
| 123 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 50kg/pit (resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7. The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including light grade GI pipe of size 15 mm upto 7 mtr incl cutting and chases on wall and floor and aking good using PCC complete all as specified and directed.Note :- On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 124 | Dismantling & taking out old unserviceable LT UG cable & Supplying & laying in replacement of LT UG cable (Conforming to IS 1554) ISI marked1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor in trenches/ducts/through HDPE pipe under roads of size 25 sqmm 4 core complete all as specifed and directed. |
| 125 | M&L for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/ floors/ duct or fixed on walls/pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed. |
| 126 | S&F GI tubing light grade ISI marked of 50 mm bore dia complete all as specified and directed. |
| 127 | M&L for feeder pillar bus bar box of size 600x450x550mm outdoor type, double door, both side openable with lockingg arrangement, kiosk type, powder coated, 300 mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of capacity 200 Amp duly colour coaded mounted on porcelaininsulators with provn of 04 nos outgoing including MCCB 160 Amp 25 KA, Ics=100% Icu=01 Nos, LED phase indicator (RYB), holes on bottom for cable entry and exit with suitable size cable gland and mild steel stand for mounting of panel board made of angle iron of size 50 x50x6 mm, 1.0 meter high (450 mm below ground level and 600 mm above ground level) along with necessary cement concrete for grouting of panel stand, foundation and connecting the panel with earthing complete all as specified and directed. |
| 128 | Taking up or down 25mm bore galvanised steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 129 | S&F or lay in trenches 25m bore galvanised steel water tubing medium grade including all fittings such as bends, elbows, tees, reducers, sockets, union etc and laid in trenches complete all as specified and directed. |
| 130 | S&F 25mm bore galvanised steel water tubing medium grade including all fittings such as bends, elbows, tees, reducers, sockets, union etc and laid in floor fixed on wall and ceiling complete all as specified and drected |
| 131 | Drilling and tapping GI water mains 50mm bore (in position) for branch connections of the internal dia 25mm, complete all as specified and directed. |
| 132 | S&F straight plain brass ferrules (or connecting screws) screwed both ends and fixed to water mains for tapping branch connection of 25 mm bore pipe, complete all as specified and directed. |
| 133 | Taking down existing unserviceable gate valve & Supply and Fix Gun metal gate valve, ISI marked, with iron wheel head screwed both ends for iron pipe, fixed in repairs complete of size 25 mm bore Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender