Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57623130

Tender For Special Repair For Replacement Of 03 Nos Ber Distribution Transformer Alongwith Allied Works At Faridkot Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Faridkot, Punjab
Tender Value
69.97 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
20 days left
EMD
1.29 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Faridkot → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair For Replacement Of 03 Nos Ber Distribution Transformer Alongwith Allied Works At Faridkot Mil Stn

BOQ

Name of Work:- SPECIAL REPAIR FOR REPLACEMENT OF 03 NOS BER DISTRIBUTION TRANSFORMER ALONGWITH ALLIED WORKS AT FARIDKOT MIL STN
Sl. No. Item Description
1Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (Copper) distribution transformer, three phase, 250 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30 degree positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2, as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 including installation on existing outdoor Plinth/2/4 pole structure complete with all fittings, accessories and item as specified and as directed. Note: - (i) The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
2Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 400 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30 degree positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (As per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 incl installation on existing outdoor Plinth/2/4 pole structure complete with all fittings, accessories and item as specified and as directed. Note: - (i) The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
3S & F gang operated air break switch, three poles with fuse unit, outdoor type, nominal system voltage 11 kV, rated voltage 12 kV, rated normal current 200 Amps, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 28 kV (rms) (ii) across the isolating distance 32 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 75 kV (Peak) (ii) across the isolating distance 85 kV (Peak), Rated short-time withstand current 25 kA for 3 seconds, rated peak withstand current 63 kA for climatic conditions at the site, mechanically operated mounted on polymer insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
4Supply laying and testing cable XLPE insulated sceened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 11000 volts grade of size 95 Sqmm 3 core complete all as specified and directed.
5M& L for Earthing complete for transformer/ panel/Lighting conductor with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, connected with and including GI strip 32mm x 6mm (upto the body of equipment) by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles, earth plate surrounded by packed layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI light grade, with funnel and wire mesh for watering, excavation, earth work PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover complete all as shown in Electrical Plate No. 3 of MES Standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed by Engineer-in-Charge
6M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
7Supply and fix cable jointing kit for 11 KV grade cable for Outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 95 sqmm to 120 Sqmm complete all as specified and directed by Engr-in charge.
8Supplying and fixing Galvanised mild steel pipe / tubing, of size 100 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified of following bore and as directed.
9Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth in soft/loose soil for laying under ground cable and getting out soft/loose soil complete all as specified and directed.
10Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
11Removing the excavated soil to a distance n. exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
12Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor Multi standard cable 240 Sqmm 3.5 Core, 1100 volts grade in trenches ducts, pipe on walls, poles including lugs, thimble nuts & bolt complete all as specified and directed.
13Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 120 mm, minimum inside dia 103 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57623130
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 69.97 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair For Replacement Of 03 Nos Ber Distribution Transformer Alongwith Allied Works At Faridkot Mil Stn
Basic Detail
Tender No CA NO CWE SGNR/TOKEN-44 OF 2026-27
Bidding Type Tender
Location
City Faridkot
State Punjab
Key Dates
Publish Date 21 Sep 2026
Submission Date 12 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 69.97 Lakhs
Tender Fee 1000
EMD 1.29 Lakhs
Exemption Available
Document List
34b14926-3140-4d1b-81f6-f9a16ff99d7c.html
BOQ_886094.xls
Tendernotice_1 (10).pdf
Tender_44.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

34b14926-3140-4d1b-81f6-f9a16ff99d7c.html

xls

BOQ_886094.xls

pdf

Tendernotice_1 (10).pdf

pdf

Tender_44.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender