Project Description

Tender for Construction Of Glass Pods In Nac 2 Atrium

BOQ

Name of Work:- Construction of Glass Pods in NAC 2 Atrium
Sl. No. Item Description
1PART A – CIVIL WORKS
2Supplying, fabricating, assembling, hoisting / erecting and fixing in position, structural steel works using MS rolled built-up sections and plates of E-250 BR Grade conforming to IS 2062 and of approved brand / make and in required size (as indicated in the drawings), length, surface finish and end finish, including profile cutting of components using water jet 3-D cutting system with special plate connector, pinion joints, plates to required lengths/widths and bent to required architectural shapes/profiles as per drawings, threading, smooth grinding / machining of edges / faces / all welding joints, preparing the surface to ensure complete removal of mill scale by using wire brushes & sand papering, necessary welding (electric arc welding using SAW/MMAW/MIG process) for required weld lengths and sizes and bolting with special shaped washers, hoisting and fixing in position to all leads, heights and levels, all accessories such as plate connectors, pinion joints, nuts, bolts, welding, necessary scaffolding / staging, etc. complete all as per approved shop drawings, technical specifications and as directed by the Engineer-in-charge.
3Structural Steel frame works welded in built up sections/ framed work, including cutting, hoisting, fixing in position for primary / secondary structural supporting system at Floor level.
4Structural Steel frame works welded in built up sections/ framed work, including cutting, hoisting, fixing in position for primary / secondary structural system for columns.
5Structural Steel frame works welded in built up sections/ framed work, including cutting, hoisting, fixing in position for primary / secondary structural supporting system for Roofing.
6Surface Preparation for Painting to Steel Surfaces: Preparing the steel surfaces by Abrasive blast cleaning to ensure complete removal of mill scale by grit / sand blasting confirming to SA 2.5 standard as per ISO 8501-1, to achieve the blast cleaned surface near to White Metal Cleanliness, until at least 95% of each element of surface area shall be free of all visible residues & rust free. The surface should be free of all visible oil, grease, dust, dirt, mill scale, rust, oxides, corrosion products and other foreign matter. The entire work shall be carried out as per directions and to the satisfaction of the Engineer-in-charge.
7Providing and applying approved anti-corrosive protective paint comprising of all labour, materials, equipment, scaffolding, and supervision for surface preparation and application of a complete anti-corrosive protective coating system to exposed steel structures as per the following:The item includes surface cleaning, edge rounding, and stripe coating on edges, welds, bolts, and hard-to-reach areas, carry-out DFT and adhesion tests using calibrated instruments and submitting Method Statement, Manufacturer’s Data Sheet etc. prior to commencement. All the coating shall be applied by airless spray methods only. Brushes shall be used only for touch-up work. The undercoat, intermediate coat and finish-coat materials shall be compatible with one another and substrates.Total dry film thickness (DFT) of the coating system shall be Minimum 90 µm and the coating system shall be certified for corrosivity category C2 - Low Environment as per ISO 12944 standard (Interior use, dry conditions). The entire work shall be carried out as per directions and to the satisfaction of the Engineer-in-Charge.
8Primer:Providing and applying approved priming coat of two component high solid, zinc phosphate amine cured epoxy primer of approved brand, shade & quality with minimum dry film thickness (DFT) of 50 µm and volatile organic compound (VOC) less than 250 gm / litres.
9Topcoat:Providing and applying approved topcoat of two component, glossy finish, high solid acrylic aliphatic polyurethane coat of approved brand, shade and quality with minimum dry film thickness (DFT) of 40 µm and volatile organic compound (VOC) less than 150 gm / litres.
10Providing and fixing a complete mezzanine roofing system comprising 12 mm thick high-impact, weather-resistant, compressed fibre cement boards conforming to IS 14862 (Type A, Category 4), with minimum density of 1450 kg/m³ (as per ASTM C1185), modulus of rupture not less than 14 MPa (as per IS 14862 / ASTM C1185), and thermal conductivity not exceeding 0.0862 W/m·K (as per ASTM C518), suitable for roofing applications.The boards shall be fixed over mild steel (MS) purlins and joists/trusses forming the primary structural framework, conforming to IS 2062 and designed as per IS 800. (The primary structural steel (purlins, joists, trusses) shall be measured and paid under a separate item and is excluded from this scope.)Necessary cleats, brackets, and interface connections required for fixing of boards and associated systems to the primary steel shall be included in this item. All welding and bolting shall conform to IS 816 / IS 9595 and IS 1367 (relevant parts) respectively.Fibre cement boards shall be fixed using stainless steel self-drilling/self-tapping countersunk screws at spacing not exceeding 200 mm c/c, ensuring firm anchorage capable of resisting design loads including wind uplift. Board joints shall be sealed with approved polymer-based jointing compound, reinforced with minimum 48 mm wide fibre mesh/jointing tape, finished flush and made watertight.The system shall include under-deck thermal and acoustic insulation using non-combustible stone wool/rock wool conforming to IS 8183, of suitable thickness and density (typically 48–64 kg/m³ or as specified), supported on GI wire mesh/chicken mesh or proprietary insulation support system. It shall also include providing and fixing non-woven glass fibre acoustic tissue (25–50 gsm) in conjunction with mineral wool insulation, serving as a fibre migration barrier and acoustic facing, compatible with insulation conforming to IS 8183 / IS 15498. The tissue shall comply with ASTM C1136 (facing requirements), exhibit adequate air permeability as per EN ISO 9053, and achieve non-combustible / Class A1–A2 fire performance as per EN 13501-1 / NBC 2016 Part 4. The tissue shall be properly wrapped/fixed to insulation with minimum 50 mm overlaps, ensuring continuous coverage, durability, and performance, complete as specified.A continuous vapour control layer (VCL) using polyethylene sheet conforming to IS 2508 or approved equivalent shall be provided at the appropriate location in the assembly, with minimum 100 mm overlaps, sealed with compatible adhesive tapes to ensure airtightness and condensation control.The complete roofing system shall meet the following performance criteria:i). Fire Performance: All components shall be non-combustible and conform to relevant provisions of IS 3809 and NBC 2016 (Part 4 – Fire & Life Safety), achieving Class A / Class 1 surface spread of flame rating.The complete roofing system shall meet the following performance criteria:i). Fire Performance: All components shall be non-combustible and conform to relevant provisions of IS 3809 and NBC 2016 (Part 4 – Fire & Life Safety), achieving Class A / Class 1 surface spread of flame rating.ii). Thermal Performance: The assembly shall be designed to achieve an overall U-value not exceeding 0.5–0.6 W/m²·K (or as specified), depending on project requirements and insulation thickness.iii). Deflection Criteria: The supporting system shall be designed such that maximum deflection does not exceed L/240 for roof members or stricter criteria as specified, ensuring no cracking or failure of board joints.iv). Wind Uplift Resistance: The fixing system (screws, fasteners, and board anchorage) shall be designed to withstand design wind loads as per IS 875 (Part 3), including uplift forces, with adequate factor of safety.The scope shall include design, supply, installation, and fixing of fibre cement boards, insulation system, vapour barrier, acoustic layers, and all accessories such as SS fasteners, cleats, brackets, anchors, binding wires, insulation supports, sealants, tapes, jointing materials, edge closures, and flashing interfaces. The item shall also include making necessary cut-outs, provisions, and sealing for services, penetrations, and fixtures, scaffolding / staging as required, ensuring complete integration with adjoining works.All work shall be executed in accordance with approved shop drawings, manufacturer’s specifications, relevant Indian Standards, and directions of the Engineer-in-Charge, ensuring structural integrity, fire safety, thermal efficiency, acoustic performance, and durability, complete in all respects.ii). Thermal Performance: The assembly shall be designed to achieve an overall U-value not exceeding 0.5–0.6 W/m²·K (or as specified), depending on project requirements and insulation thickness.iii). Deflection Criteria: The supporting system shall be designed such that maximum deflection does not exceed L/240 for roof members or stricter criteria as specified, ensuring no cracking or failure of board joints.iv). Wind Uplift Resistance: The fixing system (screws, fasteners, and board anchorage) shall be designed to withstand design wind loads as per IS 875 (Part 3), including uplift forces, with adequate factor of safety.
11Providing, fabricating, and installing Laminated Glass Partition System of 3600 mm overall height from finished floor level (FFL), designed for Glass Pods, comprising 13.52 mm thick laminated safety glass panels fixed between aluminium bottom and top rails, with structural mild-steel framing support, complete in all respects as per approved shop drawings, manufacturer’s recommendations, and the direction of the Engineer-in-Charge & comprising of: ((a) to (h) - Refer Technical Specifications for detailly explained )a). Glass Panels (Laminated Safety Glass) :b).Supporting Framework:c). Structural Framing (MS Support System):d). Guard Rail Assembly: e). Accessories & Fixings:f). Manifestation Film:g). Stainless-Steel Components:h). Installation and Finishing:
12Designing, supplying, fabricating, assembling and installing frameless openable side hung glazed doors in required sizes in internal glazed partitions or any other required location using 12mm thick fully tempered clear float glass including providing and fixing top & bottom pivot & spring type fixing arrangement in the form of patch fittings and making necessary holes etc. for fixing wherever required, providing & fixing necessary imported stainless steel (Grade 304) hardware fittings (of approved make & quality) including 2 Nos 600mm long, 32mm dia. back to back satin finished S.S Pull Handles per shutter, External series patch fittings (PT Series), US10 Door lock at bottom of each shutter & BTS 75 V 90deg with EN 1-4 spring capacity floor spring, SS satin finished floor spring covers, locking arrangements with master & grand master keys etc. which are BMS compatible, all as per approved shop drawings, specifications and as directed by the Engineer.The double action hydraulic floor spring shall be of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and with stainless steel cover plate of minimum 1.25 mm thickness with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete.Note : Lacquered glass shall be made (via curtain coating process, opaque (if viewed against a support wall), coated with PU lacquer; of uniform color consistency, environmentally friendly (no lead, no arsenic, no copper, no formaldehyde)
13In single / double leaved glazed doors
14Design, Supply and installing 132 mm thick four layered Fire Resist Dry Wall partition consist of approved Metal framework partition having maximum reachable height of 5030 mm satisfying L/240 criterion at 200Pa, possessing fire rating of 120 minutes, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw) as specified, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having U-value of 0.39W/m2K & Severe duty rating as per BS 5234 part 2.The Dry Wall Partitions shall consists of minimum four layers of fire resistant plasterboard as specified (\\"Gyproc Fireline\\" manufactured by Saint Gobain or approved equivalent) conforming to IS : 2095 / EN520:2004- TYPE-F, ASTM C1396-TYPE X, having flexural strength – {Longitudinal > 650N & transverse > 250N} on either side of the framing.The Metal frame work shall be designed in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500 hours of salt spray test as per ASTM B117, having moment of inertia of 82259 mm4 about major axis, positioned at 610mm c/c in Floor Channel & Ceiling Channel with flanges bend at 5° acute angle. Floor & Ceiling Channel shall be anchored with Rawl plugs of approved sizes having minimum Pull Out strength of 6.8KN or Nail, fixed at 600mm c/c in zig zag manner. Provide closed Stud with galvanised L Angle of adequate size, placed between the studs, behind the horizontal board joint and plaster Board strip shall be placed between Ceiling Channel and soffit.Two layers of 15 mm thick Fire resist plaster Boards fixed with drywall screws of 25mm & 50mm at minimum spacing of 300mm at Centre and 150mm at periphery of wall to either side of GI steel metal C stud frame of approved size using floor and ceiling channels of having equal flanges with approved GI stud and other side placed @ every 610 mm c/c in vertical direction up to soffit and horizontally at board joints. The board are fixed in staggered joints to avoid leakage through joints. The stud and floor channel shall be crimped together with crimping tool. 15mm thick fire rated plastrer board strip of approved width is placed between ceiling channel and ceiling slab to improve fire performance of the system. A steel noggin channel of approved size shall be provided at the horizontal joints of outer layer boards screw fixed to the studs using metal to metal flat head screws. Insulation of minimum 50 mm thick Glass wool slab of density 20 kg/m³ or Rockwool of minimum density of 60Kg/m3.shall be placed in metal framework. Glasswool / Rockwool holding clip shall be used to hold the insulation slab in its position. The boards shall be fixed vertically to the framework with joints staggered. 25x25x0.5mm angle bead shall be used at all L-Junctions of the partitions.The G.I. material for the studs, angles etc. shall conform to IS : 513, Yield Strength of 300 Mpa, Finish of AZ150 as per IS 15961. All square and tapered edges of the boards shall be jointed and finished so as to have a flush look which includes filling and finishing with approved jointing compound, paper tape & a coat of approved primer. The junctions of the partition with masonry & all penetration through the partition, Periphery & cut-outs of the partition etc. to be treated with approved Fire & Acoustic Sealant. All the performance test are carried out at NABL accredited/ government approved lab. The rate shall include for necessary scaffolding / staging for all leads, levels & heights, all accessories such as self drilling screws, nuts, bolts, provision of any additional supports for fixing to the main structure etc.all as per the manufacturer's specifications and guidelines, approved shop drawings and as directed by the Engineer-in-Charge.Note:• Control Joint to be provided at every 10m c/c along the length of wall.• For heights between 4.2m to 8m, use Deep Ceiling Channel at head (subject to deflection criterion). • Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film.• Provide Floor channel capping of 600mm for For joining two studs.• Approved CT corner bead to be applied at all corners.• Capacity of Nails shall be as per the approved shop drawing.* Provide steel studs of minimum 1mm thick or as specified in the Technical Specifications at all doors openings. *Provide extra strenthening metal frame work / studs of approved size behind electrical outlets and other Work which penetrates plasterboard dry lining system. *Apply sealant around sides and backs of electrical boxes to completely seal openings and joints to make it sound proof.
15132mm thick Fire Resist double skin (total four layered) Dry Wall Partition with Metal Frame work and minimum STC of 60 dB having outer skin with Two layers of Exterior Grade Gypsum Board of 15mm thick each and inner skin with Two layers of Sound proof Gypsum Board of 15mm thick each as per approved shop drawings..
16Dry wall partition on the staircase wall face
17Providing and applying two coats of premium first quality interior water based washable Acrylic Emulsion paint (DFT: Minimum 40–50 microns per coat, with an overall system DFT of 80–100 microns, measured as per ASTM D7091 / ISO 2808;) conforming to IS 15489 (of approved brand and shade) having anti-fungal resistant properties conforming to ASTM D3273, anti-bacterial resistant properties conforming to JIS Z 2801:2010 and having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, including applying additional coats wherever required, to internal wall, column, partition, ceiling surfaces, to give an even shade, including thoroughly brushing the surface free from foreign matter, sandpapering smooth, filling in all holes and cracks, applying lambi / palti and rubbing down the surface, lambi/palti sandwiched with two coats of approved water thinnable priming coat with cement primer having VOC content less than 50 grams/litre, including all tools, labour, scaffolding, staging, necessary primer coat as required, complete as directed by the Engineer-in-Charge. Note : Flat area in horizontal / vertical plane will be measured for payment. No additional payment will be made for grooves, cornices, vatta, mouldings etc.
18Providing and installing Acoustical Wall Paneling (\\"Ecophon Akusto Wall Panel A System\\" manufactured by Saint Gobain or approved equivalent) using Akutex FT of 1200 mm x 2700 mm size with 40 mm natural square edge, with standard approved inherent fire retardant fabric wrapped around in concealed system with grippers. The system shall include for plywood battens of 28mm thickness and 38 mm width, 12mm PVC grippers, hook on / Impaling clips & approved fabric. The wooden battens shall be fixed on the wall with the help of SS Screws at 300mm c/c. 12mm PVC grippers shall be fixed on wooden battens with drywall screws. The wall panels shall be pasted with SR998 / Moccsudal SF 200 between grippers also shall be flush inside gripper level followed by stretching and tucking-in fabric inside gripper as per approved design. The panels shall be manufactured from high density glass wool and tiles classified under absorption class A with \\"alpha w\\" value of 1 at minimum 50mm O.D.S. Classification according to EN ISO 11654, & single value ratings for NRC value 0.9 according to ASTM C 423 & Articulation class 230 as per ASTM E1111, ASTM E1110. The panels shall be recyclable and be designed to withstand a permanent ambient RH up to 95% at 300C & RH upto 75% at 300C without sagging, warping or delaminating (as per EN 13964), The glass wool core of the tiles shall be tested and classified as noncombustible according to EN ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501 - 1.The rate shall include for necessary scaffolding / staging for all leads, levels & heights, all accessories such as SS screws, heavy duty PVC rawl plugs, counter sunk flush bolts etc. & allied joinery work including cutting, planing, making rebates, jointing as directed, adhesives, making grooves as per design if required, making provision for fixing light fittings, allowance for wastage & tucking of fabric etc. all complete as per approved shop drawings, manufacturer's specifications & guidelines and as directed by the Engineer.
19Providing and fixing acoustic false ceiling at all heights using “Anutone Subtex Nubby” (or approved equivalent) square edge, glass fibre core tiles, fully encapsulated, of size 595 × 1195 × 15 mm, having density of 120 kg/m³, laid in a 600 × 1200 mm module, including all materials, labour, tools, and accessories complete as per approved drawings and direction of Engineer-in-Charge and comprising of the following: ((a) to (f) - refer technical specification for other details).a). Suspension Systemb). Ceiling Tiles: c). Performance & Compliance: d). Workmanship & Installation: e). Mode of Measurement: f). Rate to Include:
20Providing and fixing 15 mm thick high-density, compressed fibre cement floor boards conforming to IS 14862 (Type A, Category 4), suitable for structural flooring applications. The boards shall have a minimum density of 1450 kg/m³ (as per ASTM C1185), modulus of rupture not less than 14 MPa (as per IS 14862 / ASTM C1185), and thermal conductivity not exceeding 0.0862 W/m·K (as per ASTM C518).The boards shall be installed over a secondary framing system consisting of lightweight GI members, manufactured from galvanized steel sheets conforming to IS 277 / IS 513 (as applicable), which shall be adequately supported, fixed, welded and/or bolted to the primary structural steel framework (main frame/joists). (The primary structural steel framework shall be measured and paid under a separate item, and is not included in the scope of this item). The GI secondary framing shall be aligned, leveled, and installed at spacing not exceeding 300–400 mm c/c or as per approved shop drawings, ensuring adequate stiffness and load transfer to the primary steel structure.Fibre cement boards shall be fixed to the GI secondary framing using stainless steel (SS) self-drilling / self-tapping countersunk screws at spacing not exceeding 200 mm c/c, ensuring firm, level, and secure installation.All board joints shall be treated with approved polymer-based jointing compound, reinforced with minimum 48 mm wide fibre mesh / jointing tape, and finished flush to achieve a smooth and even surface suitable for subsequent floor finishes.The scope of work shall include design, supply, fabrication, and installation of fibre cement boards and GI secondary framing system, along with all associated accessories such as SS screws, bolts, nuts, washers, cleats, brackets, anchors, heavy-duty PVC/nylon rawl plugs, adhesives, sealants, joint fillers, and necessary edge treatments/grooves. The item shall also include making necessary cut-outs, provisions, and reinforcements for services, fixtures, and inserts, wherever required.All work shall be executed strictly in accordance with approved shop drawings, manufacturer’s specifications, relevant Indian Standards, and directions of the Engineer-in-Charge, ensuring proper alignment, structural performance, durability, and readiness for final floor finishes, complete in all respects.
21Providing and laying matt finished solid Engineered wooden flooring (as per EN: 13489) of approved make, shade type & size as specified below & in first quality using 3 strip configuration with Engineered wood planks of specified size in approved design/ pattern with micro beveled shaped edges in required finish including installing the planks as per floating / Glue down method with four side buckled patented Click system with tongue and groove mechanism, fixing specially manufactured underlay of 2 -3 mm thick foam layer, 0.2mm thick polyethylene sheet vapour retarder as per ASTM D4397, preparing the surface prior to installation, treating the wooden surfaces in contact with concrete / masonry with approved wood preservative, polishing, all accessories for fixing, cleaning the base of the floor etc. for all materials and measures to complete the job, including approved shop drawings, manufacturer's recommendations & as directed by the Engineer-in-charge.The dimensional tolerance for Engineered Wooden Flooring - i) The length and width shall not vary by more than ±0.25 mm, and the thickness shall not vary by more than ±0.13 mm.ii). Flatness: Lift from flat surface should not exceed maximum 1.5% of the piece’s length for Products less than 19.05 mm thick
22Three layered Engineered Wooden flooring composed of Real Hard Wood wearing layer of 3.0mm thick sliced veneer, Stabilizing Core of 10mm thick Sawn timber, and Balancing Layer of 2mm thick sliced veneer, (1200 - 2420)mm x (120 - 195)mm x 15mm sized wooden planks of approved make, shade & type, installed as per floating / Glue down method including laying of Foam underlayment, polyethylene sheet vapour retarder, preparing the subtrate etc. complete.
23Providing and fixing 4 mm thick Fire Retardant (FR) Grade Aluminium Composite Panel (ACP) wall cladding in straight, curved and profiled sections, comprising minimum 0.5 mm thick aluminium skins on both faces with FR mineral core, conforming to fire performance requirements of ASTM E84 (Surface Burning Characteristics of Building Materials) and classified in accordance with EN 13501-1 for reaction to fire, and where applicable complying with NFPA 285 for multi-storey façade assemblies. Panels shall be factory coil-coated with PVDF finish containing minimum 70% Kynar 500 / Hylar 5000 resin, with minimum 25 microns coating thickness for exterior grade applications, meeting AAMA 2605 performance requirements for high-performance architectural coatings, in approved colour and shade.Panels shall be fabricated by routing, grooving, bending, and forming to required architectural shapes and profiles with folded edges and return flanges as per approved shop drawings.The aluminium supporting subframe system shall consist of extruded aluminium alloy sections conforming to IS 733 and IS 1285 or ASTM B221 (Alloy 6063-T5 / T6), designed to withstand dead load and wind load in accordance with IS 875 (Part 3). Where steel inserts are used, design and fabrication shall comply with IS 800. Aluminium members shall be finished with minimum 20–25 micron anodizing in accordance with IS 1868 or alternatively polyester powder coating of minimum 60–80 microns DFT. The subframe shall include brackets, cleats, vertical and horizontal members, stiffeners, and necessary accessories to form a rigid and durable support system.Anchoring to RCC or structural substrate shall be by stainless steel anchor bolts of Grade 304 (interior) or Grade 316 (exterior/coastal), conforming to ASTM F593 and ASTM A240, and installed in accordance with ETAG 001 / relevant European Assessment Document (EAD) or ICC-ES guidelines for mechanical anchors. All fasteners shall be corrosion-resistant and compatible to prevent galvanic action.Prior to commencement of bulk installation, on-site anchor pull-out tests shall be conducted in accordance with manufacturer’s recommendations and ETAG / ICC-ES evaluation procedures, with a minimum safety factor of 2.5 against working load, and test reports shall be submitted for approval.The work shall include providing EPDM gaskets, isolation pads, non-staining silicone sealants, expansion gaps to accommodate thermal movement, cut-outs for services, scaffolding, lifting, protection, and final cleaning. Installation shall ensure true line, level, plumb, and proper alignment, complete in all respects as per approved shop drawings, specifications, and Engineer-in-Charge approval.
24Providing and fixing 4mm thick, 25 micron PVDF coated, FR grade, Aluminium Composite Panels (ACP) cladding to internal wall /RCC / plastered surfaces of approved dimensions / size in the openings / cutouts, edges or as specified locations at all heights, levels, as per required profile including subframe work, sealing the grooves using silicone sealents, etc. complete all as per approved design / shop drawings and as directed by the Engineer-in-Charge.
25PART B – SUPPLY AND INSTALLATION OF ELECTRICAL
26EARTHING Supply, laying/fixing of earthing conductor of CU flat /wires jointing as per IS; 3043/87 in trench/ wall/pulling through pipes using bolts, nuts, washer, welding etc. as required
27Copper wire No.10 SWG
28Copper wire No.8 SWG
2925 x 3 mm CU strips
30Supply and fixing of 150x50x 6 mm Cu. Earth bus. All accessories as required- inside the panel room
31CABLE LAYING & END TERMINATION
32Supplying and laying the following XLPE insulated PVC sheathed 1.1KV grade Aluminium armoured conductor cable conforming IS: 1554 (Part-I) in masonry cable trenches or on concrete wall /Cable trays or through pipes as per specifications. Necessary clamping should be provided while laying cables in RCC trenches, Walls etc. as instructed by the Consultant (Buried cable excavation and back filling shall be a separate line item)
33Armoured Aluminium Cables : 3.5C x25Sq.mm cable
34Armoured Aluminium Cables : 4C x16Sq.mm cable
35Armoured Copper Cables
36Armoured Copper Cables: 4C x 16sq.mm Cu. cable
37Armoured Copper Cables: 4C x 10sq.mm Cu. cable
38Armoured Copper Cables: 4C x 6sq.mm Cu. cable
39Armoured Copper Cables: 4C x 4sq.mm Cu. cable
40Unarmoured Copper Cables
41Unarmoured Copper Cables : 4R x 1C x 4sq.mm Cu. cable
42Unarmoured Copper Cables : 4R x 1C x 6sq.mm Cu. cable
43Cable End Termination supplying and terminating For 1.1KV cables with Double compression type brass cable gland and heavy duty tinned Cu. Socket for copper cable and Al. sockets for Aluminium cable. Rate shall be inclusive of all sundry materials like adhesive tape, PVC sleeves, bolts and nuts, washers etc. The cost shall include suitable size Gland Earth Clip for earthing of Cable Gland through 8SWG GI wire , end terminations suitable for 2/3/3.5/4 core cables of the following sizes as required
44Armoured Aluminium Cables :3.5C x25Sq.mm cable
45Armoured Aluminium Cables: 4C x16Sq.mm cable
46Supplying and terminating Siemens type / tropdoor compression gland, earth clamps for XLPE insulated and PVC sheathed conductor cable 1.1kv grade and making end terminations and gland earthing suitable for 2/3/3.5/4 core cables of the following sizes as required
47Armoured Copper Cables: 4C x 16sq.mm Cu. cable
48Armoured Copper Cables : 4C x 10sq.mm Cu. cable
49Armoured Copper Cables : 4C x 6sq.mm Cu. cable
50Armoured Copper Cables : 4C x 4sq.mm Cu. cable
51Unarmoured Copper Cables
52Unarmoured Copper Cables : 4R x 1C x 4sq.mm Cu. cable
53Unarmoured Copper Cables: 4R x 1C x 6sq.mm Cu. cable
54Cable tray Supply and fixing of Profile design Perforated Cable tray with horizontal & vertical bends, reducers, Tee's, cross over , suitable supports and brackets and other accessories as required confirming to IS/ IEC-61537. The Tray shall be galvanized for corrosion protection as per ISO 1461. .The trays should be tested for a safe working load as per the standard with a span distance of 1.5 meters and the deflection should be within the limits as per NEMA standards. The tray covers shall be snap fitted. The perforated tray shall be supplied with the standard length of 3 Mtr . The Bottom tray thickness shall be minimum 1.6 mm & Cover thickness shall be 1.6mm. The trays should have special hole for precise mounting & round hole for fixing supports at regular intervals .The trays shall include necessary couplers.-
55150mm x 50mm cable tray (perforated)
56300mm x 50mm cable tray (perforated)
57DISTRIBUTION BOARDSDistribution Board - IP 43 (The rate for board shall include supply and installation of all components, with MS doors such that MCB's are not visible, hardware, etc. including all connected civil works, equipped with the following. Suitable size MS adaptor box shall be provided above the DB location to terminate the incoming conduits to DB. )Supplying and fixing of the following way factory made single/three pole and neutral, sheet steel, 8 Module incomer MCB distribution board enclosure, double shuttered on surface /recess complete with tinned copper bus bar,2nos neutral link, 2nos earth bar, din bar, detachable gland plate, interconnections, cable end box, including painting, earthing ,junction box to be provided above the DB's etc. as required. (IP 43) in recess/in surface including cutting holes, rough plastering on the wall making good the damage colour washing etc. as required. The rate should include cost of materials required for DB dressing like cable mount, cable ties, black tape, blanking plate,MCB legs, black buttons, end ferrules, stickers etc., complete.. The board shall be made out of 1.6mm thick sheet steel suitably reinforced. The distribution board shall be equipped with incoming and outgoing MCB's & Circuit identification tags/cable markers etc. The distribution board shall be as per relevant IS & CEIG requirements. A common extra link shall be provided inside the DB for earthing purpose. An over all cover made out of 1.6mm thick sheet steel with flush type screws / lockable arrangement.
588WAY 7 segment TPN DBSupply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCB DB (PPI) comprising of the following :i) 63A 4P MCB 10kA (B & C-Curve) – 1No. as incomer.ii) 40A DP RCBO 100mA (B & C-Curve) – 3Nos. as sub incomer.iii) Each 40A DP RCBO phase incomer consist of 8Nos.10/16/20A 10kA SP MCB (B & C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.iv) With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. Vacant outlets shall be fitted with blanking plates. The rate shall include necessary connected civil works like chipping, rough plastering etc.
596WAY 7 segment TPN DB (UPS)Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 6way MCB DB (PPI) comprising of the following :i) 40A 4P MCB 10kA D-Curve) – 1No. as incomer.ii) 32A DP RCBO 100mA (D-Curve) – 3Nos. as sub incomer.iii) Each 20A DP MCB phase incomer consist of 6Nos.10/16/20A 10kA SP MCB (D-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.iv) With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. Vacant outlets shall be fitted with blanking plates. The rate shall include necessary connected civil works like chipping, rough plastering etc.
60TAP-OFF BOXES Supply, installation, testing and commissioning (SITC) of tap-off box suitable for connection to the busbar trunking system, complete with factory-fitted TPN/DP MCCB of specified current rating and breaking capacity, insulated enclosure with IP protection as specified, copper busbar contacts, shrouds, mechanical interlock, incoming plug-in arrangement, outgoing cable termination, earthing terminals, gland plate, phase barriers, danger labels, all internal wiring, mounting accessories and hardware, complete in all respects as per specifications and manufacturer's recommendations. The tap-off box shall be compatible with the existing/proposed busbar trunking system and suitable for safe operation under the specified electrical parameters.
6163A 16kA MCCB
6240A 16kA MCCB
63WIRING SYSTEM
64Wiring Light / exhaust fan pointSupplying all materials and wiring for light points/exhaust fan using 3 runs of 1.5 mm² 1.1kV grade PVC insulated FRLS copper conductor single core stranded wires run continously as per IS through ISI grade medium gauge rigid PVC conduits concealed in wall / slab etc, complete with necessary accessories, including supplying and fixing 6A modular type switch housed in a suitable factory made M.S box with moulded front plate including earthing the box, 3 plate ceiling rose etc. complete as required including rough plastering. (Colour coding to be followed Phase (Red, Yellow, Blue), Neutral- Black & Earth - Green) (length of circuit upto 5m length)
65Circuit length upto 5m
66Circuit length upto 10m
67Circuit length upto 15m
68Wiring Light Point without control switch Wiring for light point with 3 runs of 1.5 mm² 1.1kV grade PVC insulated FRLS copper conductor single core stranded wires, run as per IS through ISI grade medium gauge rigid PVC conduits concealed in wall / slab etc, complete with necessary accessories, in surface/recessed, 3 plate ceiling rose etc. complete as requiredJunction box to be provided below the beam bottom.(without control switch)(for group controlled light points)( Colour coding to be followed Phase(Red, Yellow, Blue), Neutral- Black & Earth - Green)Circuit length upto 5m
69Double controlled light pointSupply, installation, testing and commissioning of double-controlled light point wiring using 3 runs of 1.5 sq.mm, 1.1 kV grade FRLSH PVC insulated copper conductor single-core stranded wires in ISI-marked rigid PVC concealed conduits and MS conduits in exposed areas, complete with all accessories. The item includes 2 nos. 6A two-way modular switches in earthed MS box with front plate, plate ceiling rose, proper looping/termination, colour coding (Phase–Red/Yellow/Blue, Neutral–Black, Earth–Green), and making good all civil works, complete as per IS standards.Circuit length upto 5m
70Wiring Fan pointSupply, installation, testing and commissioning of fan point wiring using 3 runs of 1.5 sq.mm, 1.1 kV grade FRLSH PVC insulated, copper conductor, single-core stranded wires drawn through ISI-marked medium-duty rigid PVC conduits concealed in walls/slabs and MS conduits in exposed areas, complete with all conduit accessories, junction boxes, bends, couplers, saddles, inspection boxes and fixing accessories. The item shall include heavy-duty fan hook box with fan hook (fan hook box for open ceiling areas & anchor bolt for false ceiling areas as per the drawing)., 2-module step-type electronic fan regulator mounted in an earthed MS flush box with modular front plate, one 6A modular 1-way switch, wiring from switch box to fan outlet, proper looping, ferruling, colour coding of conductors (Phase – Red/Yellow/Blue, Neutral – Black, Earth – Green), termination, testing, commissioning, and making good all civil damages. The work shall be carried out complete in all respects in accordance with the relevant IS standards
71Wiring Wall Fan pointSupplying all materials and wiring for wall fan points 2 runs of 1.5sq.mm and one run of 1.5mm² PVC insulated FRLSH copper conductor single core stranded wires continuously run as per IS through ISI medium grade rigid PVC conduits concealed in wall/slab etc and MS conduits in open area, complete with necessary accessories, including supplying and fixing 6A modular type switch and socket housed in a suitable factory made M. S. box with moduled front plate including earthing the box etc. complete as required.( Colour coding to be followed Phase(Red, Yellow, Blue), Neutral- Black & Earth - Green)
726A Plug points - independent positionSupply, installation, testing and commissioning of 5A plug point wiring (independent position) including 3 runs of 1.5 sq.mm,(for internal wiring) 650V grade FRLSH PVC insulated copper conductor single-core stranded wires in ISI-marked rigid PVC concealed conduits and MS conduits in exposed areas, complete with all accessories. The item includes 6A modular 3-pin shuttered socket (2-in-1) controlled by 6A switch in earthed MS box with front plate, proper termination, earthing, looping to circuit, and making good all civil works, complete as per IS standards.
73Circuit length upto 5m
74Circuit length upto 10m
75Circuit length upto 15m
766A Plug points - combined position Supply, installation, testing and commissioning of 5A combined plug point including 3 Run of 1.5 sq.mm, FRLSH PVC insulated copper conductor single-core stranded wire in ISI-marked for internal wiring through rigid PVC concealed conduits and MS conduits in exposed areas, complete with all accessories. The item includes 6A modular 3-pin shuttered socket (2-in-1) controlled by 6A modular switch in factory-made earthed MS box with front plate, complete with proper termination, earthing, looping to circuit, and making good all civil works including plastering (as required).
7716A Power plug pointsSupply and installation of 16A combined modular type shuttered power socket outlet controlled by 20A modular switch, mounted on factory-fabricated MS box with front plate and integral earthing provision. The work includes internal interconnections, proper termination, looping, and earthing of the box, complete with all necessary accessories and as required for safe operation as per relevant IS standards.
7820A DP switchSupply and installation of 20A double pole (DP) switch, housed in a factory-fabricated recessed MS box with frame and front plate, complete with internal connections, proper termination, and earthing of the enclosure. The work includes fixing, testing, commissioning, and all necessary accessories, complete in all respects as per relevant IS standards
7920A SocketSupply and installation of 20A heavy-duty power socket outlet suitable for indoor AC unit, housed in a factory-fabricated recessed MS box with frame and front plate, complete with internal wiring, proper termination, and earthing of the enclosure. The work includes fixing, testing, commissioning, and all necessary accessories, complete in all respects as per relevant IS standards.
80WIRING & ALLIED WORKS
81Supply and wiring of following runs of FRLSH PVC insulated, 1.1kV grade, copper conductor, stranded wires and copper bare earth wire drawn through existing suitable size ISI grade heavy duty PVC conduit/MS Conduit including rough plastering with all accessories as required. The earth wire shall be of green colour. (conduit separate item )
822 Runs 6sq.mm copper wire and 1 run of 6 sq.mm copper wire
832 Runs 4 sq.mm and 1 run of 4 sq.mm copper wire
842 Runs 2.5 sq.mm. and 1 run 2.5mm² Cu wire
853 Runs 1.5 sq.mm. Cu wire
86PVC Conduit and accessories Supply and providing of the following size electrical grade ISI heavy duty PVC pipe through wall, floor, ceiling, trays etc. including rough plastering and the supply of all accessories as required. Junction/ pull boxes should be provided at every 6 meters and also to be provided below the beam bottom.
8720mm PVC Conduit
8825mm PVC Conduit
8932mm PVC Conduit
90MS Conduit and accessories Supply and providing of the following size electrical grade ISI medium grade MS pipe through wall or along the lift shaft/. .including rough plastering and the supply of all accessories as required. Junction/ pull boxes should be provided at every 6 metres.
9120mm MS Conduit
9225mm MS Conduit
9325mm MS flexible Conduit
94GI Flexible conduitsSupply and providing of the following size electrical grade ISI medium grade GI flexible pipe suspended from ceiling junction boxes/ ceiling roses to the points or above the false ceiling/ exposed , including the supply of flexible glands and all other accessories as required.
9520mm GI flexible conduit
9625mm GI flexible conduit
97Casing & Caping Supply, installation, testing and commissioning of heavy-duty PVC casing and capping of approved make, suitable for surface mounting of power, lighting and ELV (data/voice) cables to workstations, complete with all accessories such as tees, bends, couplers, end caps, junctions, screws, rawl plugs and fixing hardware, including cutting, drilling, making good the disturbed surfaces and providing proper support, complete as required.
9825 mm x 20 mm
9932 mm x 20 mm
100LIGHT FIXTURES : Supply of Light fixtures shall be part of scope .INSTALLATION OF FITTINGS Installation, testing and commissioning of the following light fittings complete with internal wiring, fixed directly in Wall / directly in Ceiling / Suspended from ceiling using down rods / suspended from ceiling using angles & fixed in channels / mounted in False ceiling with all necessary accessories like down rods, chains with hooks, angles, channels, ceiling rose, suitable screws etc. Rate shall be inclusive of all the accessories, drivers, power supply unit, starters, LED lamps as mentioned, control gear/ controller as required, drivers and allied items for LED fittings, and all the impaled items for LED fittings, and all the impaled items required for proper functioning of light fixtures. All light fixtures model will be as per Architect/ Lighting consultant
101Recess Mounted Back-Lit Luminare with strecthed fabric, barrisol or equivalent, design and dimensions as per drawing, 3500K, 11000Lm Delivered, L90/B10>50,000Hrs, CRI>90, flicker-free & long life drivers, DALI Dimmable, 5year warranty, Minimal trim width as per manufacturer recommendations, white powder coated finish, supplied complete with all necessary installation accessories and Drivers etc, IP44, installation to be supervised by manufacturer trained representative. Specifications shall be strictly as per Product catalogue attached for reference.
102ILC - Lineao, 36W/PM, Suspended direct-indirect modular linear light, design and dimension as per drawing, 3500K, 1000Lm/mtr downward and 2000Lm/mtr upward Delivered Lumens, L90/B10>50,000hrs, CRI>90, clear prismatic diffuser for indirect lighting and UGR<19 diffuser for downward lighting. Provide separate DALI Dimmable ckts for downward lighting and upward lighting, flicker-free, 5 year warranty, to be with no visible joint lines for both body and diffuser, custom ral shade powder coated finish as per architect request, supplied complete with all necessary installation accessories and suspension kit, IP44. Specifications shall be strictly as per Product catalogue attached for reference.
103ILC- LONG SPOT Recesse low-glare deep-recessed downlight with medium flood of Quantum R or equivalent. 15W, 1200Lm. Delivered, 3000K, CRI>90, UGR<19, 40° symmetrical soft beam, DALI Dimmable flicker-free, IP65 rated optical compartment and IP44 from behind.
104ILC-LED Strip light with Ribbion pro or equivalent, 9.6W/Mtr, 1500Lm/Mtr Delivered, 3000K, CRI>90, IP20, Remote group DALI Dimmable drivers 24V/50Hz as per Site requirement to be provided to Engineer's approval, Flicker-free. Extruded Aluminium profiles with 45° light throw and frosted UV stabilized diffusers to be included as per site requirements and dimensions. Specifications shall be strictly as per Product catalogue attached for reference.
105ILC-LED Strip light with Ribbion pro or equivalent, 9.6W/Mtr, 1500Lm/Mtr Delivered, 3000K, CRI>90, IP20, Remote group DALI Dimmable drivers 24V/50Hz as per Site requirement to be provided to Engineer's approval, Flicker-free. Extruded Aluminium profiles with 45° light throw and frosted UV stabilized diffusers to be included as per site requirements and dimensions. Specifications shall be strictly as per Product catalogue attached for reference.
106ILC-LED Strip light with Ribbion pro or equivalent, 9.6W/Mtr, 1500Lm/Mtr Delivered, 3000K, CRI>90, IP20, Remote group DALI Dimmable drivers 24V/50Hz as per Site requirement to be provided to Engineer's approval, Flicker-free. Extruded Aluminium profiles with 45° light throw and frosted UV stabilized diffusers to be included as per site requirements and dimensions. Specifications shall be strictly as per Product catalogue attached for reference.
107Driver 150W, For strip DALI DIMMABLE, DT6
108LED Strip light with Ribbion pro or equivalent, 14.4W/Mtr, BLUE LEDs, 260Lm/Mtr @ BLUE (1935Lm/Mtr @ 3000K) Delivered, IP65, Remote group DALI Dimmable drivers 24V/50Hz as per Site requirement to be provided to Engineer's approval, Flicker-free. Extruded Aluminium profiles with downward light throw and frosted UV stabilized diffusers to be included as per site requirements and dimensions. Specifications shall be strictly as per Product catalogue attached for reference.
109LED Strip light with Ribbion pro or equivalent, 14.4W/Mtr, BLUE LEDs, 260Lm/Mtr @ BLUE (1935Lm/Mtr @ 3000K) Delivered, IP65, Remote group DALI Dimmable drivers 24V/50Hz as per Site requirement to be provided to Engineer's approval, Flicker-free. Extruded Aluminium profiles with downward light throw and frosted UV stabilized diffusers to be included as per site requirements and dimensions. Specifications shall be strictly as per Product catalogue attached for reference.
110Driver 150W, For strip DALI dimmable, DT6
111Recesse assymetrical wall-washer Downlight of Modoc RWw or equivalent. 10W, CRI>90, 3000K, flicker free DALI Dimmable, IP 20. Specifications shall be strictly as per Product catalogue attached for reference
112PART C – SUPPLY AND INSTALLATION OF ELV WORKS
113DATA, NETWORKING & VOICE
114Supply, fixing, testing and commissioning of Cat 6A UTP Data Outlet comprising shuttered RJ45 information outlet mounted on a modular faceplate with mounting frame and minimum 1.6 mm thick factory-fabricated recessed MS back box, complete with fixing hardware, identification labels, cable management accessories, termination of data cable, connections, testing and commissioning, and all other accessories and incidental works required for satisfactory operation, complete in all respects
115Supply, installation, testing and commissioning of Telephone Socket (Single Line RJ11) comprising modular RJ11 shuttered telephone jack mounted on a suitable modular faceplate with mounting frame and factory-fabricated recessed MS back box of minimum 1.6 mm thick factory-fabricated recessed MS back box, complete with fixing hardware, identification labels, cable management accessories, termination of data cable, connections, testing and commissioning, and all other accessories and incidental works required for satisfactory operation, complete in all respects
116Supply and fixing TV socket (Coaxial jack) mounted on a suitable modular faceplate with mounting frame and factory-fabricated recessed MS back box of minimum 1.6 mm thick factory-fabricated recessed MS back box, complete with fixing hardware, identification labels, cable management accessories, termination of data cable, connections, testing and commissioning, and all other accessories and incidental works required for satisfactory operation, complete in all respects
117Supply, laying, drawing, dressing, testing and commissioning of Cat 6A UTP LAN Cable as per standards, suitable for applications, drawn through existing surface or recessed MS/PVC conduits, trunking, raceways, cable trays, or partitions as required. The item shall include cable pulling, routing, dressing, identification, fastening, cable ties, markers, ferrules, sleeves, and all incidental materials and accessories required for complete installation. The work shall also include termination at both ends, continuity testing, certification/testing of the installed link, commissioning, and handing over complete in all respects1 run of Cat 6A cable
118Supplying, laying, drawing, dressing, testing and commissioning of 0.5 mm² multi-pair telephone cable (as required number of pairs, copper conductor, PVC insulated and sheathed, suitable for voice communication), drawn through existing surface or recessed MS/PVC conduit, trunking, raceways or cable trays as required. The work shall include proper routing, pulling, dressing, identification tagging, cable ties, ferrules, markers, and all necessary accessories and incidental materials required for complete installation. The item also includes termination of all pairs at both ends on terminal blocks/punching frames as required, continuity testing, proper identification, and commissioning of the complete system 2 pair 0.5 mm²
119Supply and drawing of following pair RG6 cable for television in the existing surface/ recessed MS/ PVC conduit as required.
120Supplying and fixing of heavy duty PVC conduit of following sizes, conforming to IS standards, along with all standard accessories such as bends, couplers, junction boxes, inspection bends, tee, elbows, reducers, saddles, spacers, clamps, and fixing hardware, suitable for surface or recessed installation as required. The work shall include laying of conduit on wall/ceiling with proper alignment and spacing, fixing with suitable clamps/saddles/screws at regular intervals, and in case of recessed installation, cutting/chasing of walls, making grooves, embedding conduit, and finishing with cement plaster and making good the surface to match the existing finish. The item shall also include, proper alignment, cleaning of conduits, and ensuring smooth passage for cables, complete in all respects
12120 mm PVC conduit
12225 mm PVC conduit
123Supplying and providing of electrical grade ISI marked medium grade MS conduit pipe of following sizes, including all necessary accessories such as bends, couplers, sockets, reducers, inspection/pull junction boxes, clamps, nuts, bolts, washers, hangers, saddles, and fixing hardware, suitable for installation through walls or along lift shafts as required. The work shall include cutting/chasing of walls where required, proper alignment and fixing of conduits, welding/fastening of supports in lift shafts, and providing junction/pull boxes at intervals not exceeding 6 metres or at bends/changes in direction, complete with covers and suitable provisions for cable pulling
12420mm MS Conduit
12525mm MS Conduit
126Casing & CapingSupply, installation, testing and commissioning of heavy-duty PVC casing and capping of approved make, suitable for surface mounting of power, lighting and ELV (data/voice) cables to workstations, complete with all accessories such as tees, bends, couplers, end caps, junctions, screws, rawl plugs and fixing hardware, including cutting, drilling, making good the disturbed surfaces and providing proper support, complete as required.
12725 mm x 20 mm
12832 mm x 20 mm
129Supply, installation, testing and commissioning of Wireless Access Points (APs) with integrated antennas, supporting restricted regulatory domain compliance and dual-band operation as required, suitable for enterprise-grade Wi-Fi network deployment. The item shall include ceiling/wall mounting accessories, manufacturer-approved access point mount kit, power supply arrangement through PoE injector or PoE switch (as applicable), patch cords, RJ45 connectors, labeling, and all necessary hardware and accessories required for complete installation.Wifi coverage 30 M
130Supply, Store , Installation, Testing and Commissioning of Cat-6A U/UTP patch panels shall ganged adapter style patch panel will utilize increments of six RJ-45 style jacks in a common molded component 24 port per 1Rack unit, Straight and angled option shall be available as per the site requirement. patch panel type shall be compliant with IEC 60603-7-4, panel must be capable of supporting an Shall permit future migration to intelligent infrastructure management systems without any interruption to service due to patch cord removal or terminal block re-termination, panel should support the strain relief bar in the back of the panel. Bar should have the cable holders with Velcro to hold the cables in place.
131Rack Supply and installation of 2U Floor Mounted Network Rack suitable for housing networking, fabricated from Fabricated from minimum 1.2–1.5 mm thick CRCA steel with epoxy powder-coated finish, complete with front tinted toughened glass door with lock and key arrangement for secure access and visibility. Rack should have wheels and brakes on all 4 corners as required. The rack shall be provided with 2 pairs of 19-inch mounting rails with U-marking, welded side walls, proper ventilation slots, and provision for cable entry from top and bottom. The item shall include standard accessories such as 1U cable manager (1 No.), hardware installation packet, and all necessary fixing accessories.The rack shall be supplied complete with 6 socket, 5 Amp Power Distribution Unit (1 No.), and roof-mounted fan unit (1 No.) rated approximately 90 CFM, 230V AC for proper ventilation and heat dissipation of active network equipment.The scope includes mounting of rack at location, proper leveling and fixing, cable dressing with wire manager, termination support, labeling, earthing provision (if required), testing of PDU and fan unit, and commissioning of complete rack system
132CABLE TRAY FOR ELV SERVICES
133Fabricating, supplying and erecting MS ladder type cable tray, powder coated and enamel painted, suitable for laying power, lighting, telephone, data and TV cables, including all bends, fittings, accessories, supports, hangers, and MS brackets fixed to wall/ceiling with anchor fasteners.Rate includes all civil works such as drilling, grouting, making good surfaces, alignment, leveling, earthing continuity (if required), and all incidental works complete
134150mm x 50mm cable tray
135300mm x 50mm cable tray
136Supply and installation of MS supports for cable tray system including clamps, hangers, support angles, cleats, and expansion/anchor bolts, fixed to wall/ceiling/structure as required. Work includes fabrication, drilling, erection, and finishing with one coat red oxide primer and enamel paint, complete in all respects for proper supporting of cable trays as approved
137PART D – SUPPLY AND INSTALLATION OF FIRE ALARM SYSTEM (FAS) & FIRE PROTECTION SYSTEM (FPS)
138FIRE ALARM SYSTEM (FAS)
139SITC of Automatic Analogue Addressable Smoke Detector, suitable for installation below false ceiling, complete with mounting base (Including MS box), integral LED indicator, rotary address switches for detector addressing, automatic drift compensation, and floating sensitivity adjustment. Detector shall be suitable for operation in an ambient temperature range of 0°C to 50°C and compatible with the addressable fire alarm system. The detector shall be UL Listed (7th Edition) and/or EN 54 certified, complying with the latest applicable NFPA standards. The item shall include all accessories, fixing hardware, testing, commissioning, and satisfactory operation, complete as required
140SITC of Automatic Analogue Addressable Multi Detectors below ceiling/false ceiling as required, each complete with mounting base (Including MS box), integral LED indicator, and rotary address switches for programming. Smoke detectors shall have intelligent analogue sensing with automatic drift compensation and floating sensitivity; heat detectors shall be fixed temperature and rate-of-rise type. Suitable for 0°C to 50°C ambient conditions and compatible with addressable fire alarm system. UL Listed (Smoke: 7th/9th Edition, Heat: 9th Edition), EN 54 certified and NFPA compliant with latest amendments. Includes all accessories, wiring, testing, commissioning, and integration complete as required
141Supply, laying, Testing & Commissioning of ISI Marked 2 Core x 1.5 Sq.mm Multistrand Copper Shielded Twisted Pair FRLS PVC Insulated Armoured Cable, laid on wall/slab/structure with GI saddles and spacers at 0.5 m intervals, complete with lugs, compression glands, cable tags, ferruling, and end terminations. Cable shall be red in colour. Includes testing, checking of continuity and insulation resistance, and commissioning complete as required-Colour - Red
142Supply, installation, testing, and commissioning of UL Listed and FM Approved Line Isolator Module. Device must automatically isolate wire-to-wire short circuits on the addressable Signaling Line Circuit (SLC) loop and automatically restore the loop upon fault correction. Complete with backbox and mounting accessories. (e.g., Honeywell HM-DISO-UL / Notifier ISO-X / Equivalent)
143Supply, Installation, Testing & Commissioning of Addressable type Manual call (Pull down type) Station complete with, all accessories as per specifications. (UL 9th Edition Approved/ EN54 and NFPA compliant or latest amended upto date) complete as required.
144Supply, Installation, Testing & Commissioning of loop addressable hooter cum Xenon type Strobe with 177 cd Intensity with control module (colourless transperant lense indoor type) as per specifications. complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling as specified in NFPA 72 ‐ 2019 edition. (UL Listed/ EN54 or latest amended upto date)
145Supply, Installation, Testing & Commissioning of Addressable monitor modules for Sprinkler Tamper proof switch and Flow Switch as required. (UL 7th Edition Approved and NFPA compliant/ EN54 or latest amended upto date) complete as required
146Supply, Installation, Testing & Commissioning of addressable Relay/Control Module with relay etc. for Sounder, AHU, Fire Dampers, Smoke Ventilation complete as required and as per specifications. (UL 7th Edition Approved and NFPA compliant/ EN54 or latest amended upto date) complete as required.
147Supply and fixing MS box for fixing detectors
148FIRE PROTECTION SYSTEM (FPS)
149AUTOMATIC SPRINKLER SYSTEM
150Supply, installation, testing, and commissioning (SITC) of standard-response sprinkler heads, quartzoid glass bulb type, pendant/upright, 15 mm threaded connection, 68°C (155°F) rated, K-factor 80 (K5.6), minimum 6 mm orifice.Sprinklers shall be brass body with chrome-plated finish, frangible glass bulb thermal element, hydraulically designed deflector for uniform discharge, as per manufacturer’s listed data. Concealed type (if applicable) shall include factory cover plate with finish/color subject to Client/Consultant approval.Complete with accessories.
151Upright Sprinkler
152Pendant Sprinkler(Concealed)
153Side Wall Sprinkler (Extended Type)
154Above Ground:Supply, installation, testing, and commissioning of MS pipework Class ‘C’ conforming to IS 1239 (Part 1), heavy grade, including surface preparation with 2 coats Zinc Chromate primer and 2 coats approved low-VOC paint. Pipe supports shall include channel/Hi-tech supports (for shafts), anchor fasteners, bolts, nuts, clamps, and U-bolts, installed as per approved drawings. Pipe tapping/ drilling shall be carried out using drilling machine or hole saw cutter only, ensuring controlled fabrication and compliance with FM practice requirements. Scope includes cutting, threading/ grooving, erection on walls/ ceilings /shafts, and all wall/floor penetrations including chasing, drilling, core cutting, and reinstatement with cement mortar finish to match existing surfaces.Rate shall be inclusive of all materials, labour, tools, tackles, consumables, and equipment including threading machine, grooving machine, drilling machine, hole saw cutter, and cutting tools, complete in all respectsng, erection on walls/ ceilings/shafts, and all wall/floor penetrations including chasing, drilling, core cutting, and reinstatement with cement mortar finish to match existing surfaces System shall include complete piping with all fittings and accessories: 25–50 mm size in forged socket/threaded type and 65 mm and above in ERW butt-welded type, including reducers, tees, elbows, flanges, malleable iron specials, and all required jointing materials.Fittings: (25mm to 50mm forged socket / Threaded type. 65mm and above ERW butt welded fitting)Pipe drilling : Drilling onto pipes to be done using Drilling machine or Hole saw cutter only. Per FM standards.Note: The approved paint shall be of Low VOC value.
15525mm nominal dia
15632mm nominal dia
15740mm nominal dia
15850mm nominal dia
15965mm nominal dia
160Supply, installation, testing, and commissioning of stainless steel corrugated braided flexible hose for sprinkler drops in false ceiling, 25 mm dia, 1500 mm length, 16 bar rated, Assembly shall be stainless steel construction with braided outer layer, complete with factory-fitted union/reducer ends and mounting clamps for rigid, leak-free connection between branch pipe and sprinkler head.Installation shall ensure proper alignment, secure support, and, complete as per approved drawings.
161Supply, installation, testing, and commissioning (SITC) of gun metal/chrome-finished forged brass ball valves, PN-16 rated, full bore, quarter-turn operation, with screwed (BSP/NPT) end connections.Valves shall be heavy-duty, corrosion-resistant construction with PTFE seats/seals, blow-out proof stem, and positive shut-off suitable for fire protection/water service applications. Each valve shall be factory tested for shell and seat leakage and provided with locking arrangement/handle as applicable. Installation shall include proper alignment with piping system, leak-tight threaded joints, and complete commissioning with functional testing under operating pressure.25 mm dia
162Supply, installation, testing, and commissioning of Stainless Steel (S S) butterfly valves, PN-16 rating, wafer type, conforming to BS 5155, with resilient seat (slim seal), suitable for fire protection/water service.Valves shall be lever-operated up to 150 mm size and gear-operated for sizes above 150 mm, with epoxy-coated body, stainless steel disc/shaft, and replaceable seat.Each valve shall be complete with matching flanges, gasket, bolts, nuts, washers, and all required accessories for leak-proof installation.Provision shall include tamper-proof supervisory switch assembly for open/closed position monitoring, compatible with fire alarm system requirements.Installation shall be complete in all respects including alignment, torque tightening, functional testing, and commissioning under operating pressure.65 mm dia
163Supply, installation, testing, and commissioning Zone Control Assembly comprising PN-16 C.I. butterfly valve, pressure gauge with isolation cock, and drain/test valve assembly.Unit shall be complete with matching flanges, gaskets, bolts, nuts, and washers, suitable for fire protection zoning for isolation, pressure monitoring, and system drainage. Assembly shall be approved as per standards , factory/manufacturer compatible, and installed complete as per approved drawings, including alignment, leak testing, and commissioning.65 mm dia
164Supply, installation, testing, and commissioning of paddle-type flow switch for fire protection sprinkler system.Flow switch shall be suitable for installation on MS/GI piping, with adjustable paddle assembly, tamper-proof housing, SPDT micro-switch contacts, and weather/dust resistant enclosure (IP65 or higher), compatible with fire alarm interface.Unit shall be installed on approved pipe sizes as per manufacturer’s recommendations, complete with all accessories, wiring termination, alignment, and functional testing for alarm actuation at specified flow conditions.65mm dia
165Supplying, installing, testing and commissioning of 25mm dia Sight glass unit for sprinkler drain, drain valves, ball valves, check valves, Union etc. complete.Set shall be UL Listed
166EXTINGUISHERS & FIRE SUPPRESSIONSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.
167Supplying, installing, testing and commissioning of ISI marked (IS:15222, IS : 15683 and IS : 2190) Fire Extinguisher, Carbon-di-oxide type capacity 2 Kg, >=99.5% pure CO2. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. (Lift Machine Room)
168Supplying, installing, testing and commissioning of 4 kg capacity ABC type stored pressure Fire extinguishers as per IS : 15683 and IS : 2190 of following type & capacity. Portable, fire extinguisher charged with MAP 90% Dry Powder, ISI marked, complete with bracket, hose, and pressure gauge Dry chemical powder fire extinguisher filling in brand new cylinder with powder coated finish, fitted with Gun metal union, discharge nozzle, wall mounting bracket, average discharge time is 14 Sec etc. complete.
169FIRE SIGNAGES
170The following descriptive photo luminescent Green or Red colour safety signages in different sizes / graphics /colours / texts can be made according to the standards accepted by the local Fire service department. The intensity of glow in dark should last not less than 2 hours and the strongest glow shall be produced in the first 30 minutes
171Fire extinguisher - with symbolSize 150 x 400 mm
172In case of fire - with Manual call point symbolSize 150 mm X 200 mm
173Arrow + Running man +Emergency exit - with symbol.Size 150 x 400 mm
174Providing and fixing in position the signages \\" FIRE ORDER\\" it should contain the following matter on 3mm thick \\"Opaque\\" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyl painted foam board of 3' x 4'.
175A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POINTS.C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM.
176ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.A) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: 101 / -------- / -------- / --------.B) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE.C) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE.D) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER……..FIRE FIGHTING AGNECY -------------------------------PHONE : -----------------------FAX-----------------------
177PART E – SUPPLY AND INSTALLATION OF HVAC WORKS
178HIGH SIDE
179AC EQUIPMENTS
180Supply, installation, testing and commissioning of ceiling concealed one-way corner cassette type chilled water fan coil unit (FCU), suitable for connection to a central chilled water system, complete with copper tube aluminium fin cooling coil, EC/direct drive fan motor, washable air filter, insulated condensate drain pan, factory-fitted 2-way/3-way modulating control valve, balancing valve, air vent, drain valve, flexible connections, insulated condensate drain piping, decorative panel, wired wall-mounted controller, all mounting accessories, interconnecting control wiring and accessories, complete as specified. Unit shall be suitable for operating with chilled water temperatures of 7°C/12°C or as specified2 TR nominal capacity 800 cfm
181Supply, installation, testing and commissioning (SITC) of high wall mounted split type chilled water fan coil unit (FCU), suitable for connection to a central chilled water system, complete with copper tube aluminium fin cooling coil, low-noise direct drive fan motor, washable air filter, insulated drain tray, motorized control valve, balancing valve, air vent, drain valve, wired wall-mounted thermostat/controller, insulated chilled water piping connections, condensate drain piping, supports, interconnecting control wiring and all accessories required for satisfactory operation, complete as specified. Unit shall be suitable for chilled water temperatures of 7°C/12°C or as specified.1 TR nominal capacity 400 cfm
182LOW SIDE
183UPVC DRAIN PIPES:Supply, Installation, testing & commissioning of Rigid UPVC condensate drain pipes of following size duly insulated with 9 mm thick closed cell nitrile with factory laminated black treatd woven cloth surface insulation in the form of pre-formed pipe sections and along with necessary clamps, fittings such as bends, tees etc.
18432 mm dia
18525 mm dia
186CHILLED WATER PIPING:Supply & laying of piping of heavy duty seamless mild steel tubes with weld-able socket type fittings. All tubes shall conform to IS 1239-79 (upto 250mm dia) Includes fittings tees, bends,couplings, collars, crosses, reducers etc. and making good the walls etc. for concealed pipes and clamping the pipes at regular intervals , supporting before and after change of directions for suspended pipes, etc.
18725 mm Dia nominal bore.
18832 mm Dia nominal bore.
18940 mm Dia nominal bore.
19050 mm Dia nominal bore.
19165 mm Dia nominal bore.
192Supply, Installation and fixing of following thickness of Extruded polystyrene insulation. The surface of the pipe shall be rendered dry and clean. Hot bitumen applied uniformly at the rate of 1.5 kg/sqm. A similar layer of bitumen is applied on the inside surface and on the edge of the pipe section. All joints shall be staggered and sealed with sealant. Polythene faced hessian shall be wrapped and fixed in hot bitumen with an over lap of 75mm. The finish shall consist of treated woven glass cloth and 12mm sand cement plaster (1:3) with a mixture of water proof compound finished smooth over 20 mesh 0.63mm thick galvanized chicken wire mesh.From 32 to 250mm dia - 50mm thickness one layer Insulation as per the specification over pipe of the following NB including valves extra as specified complete with finish specified indoor
19325 mm Dia nominal bore.
19432 mm Dia nominal bore.
19540 mm Dia nominal bore.
19650 mm Dia nominal bore.
19765 mm Dia nominal bore.
198Supplying , Installing, Testing and Commisioning of pipe supports using MS powder coated Electro plated / Electro galvanised Zinc coated steel brackets, supports, collar clamps, U clamp, split clamp with EPDM rubber lining wherever applicable with necessary drilling holes to suit the insertion of pipe clamps, deburring etc. all complete, as per detailed drawing for supporting Chilled water pipe line.
199Supply & Installation only of Pressure Independent type balancing cum control valve with flanges, unions as required.
20050 dia Nominal Bore
20125 dia Nominal Bore
202Control CableSupply, laying, connecting, testing and commissioning of low and medium voltage power and control cabling.4C,1.5 sq mm control cable. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57623115
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 12-10-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Construction Of Glass Pods In Nac 2 Atrium
Basic Detail
Tender No ICSR/8265/071/2026/GLASSPODS
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 21 Sep 2026
Submission Date 12 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 2.31 Lakhs
Exemption Not Available
Document List
BOQ_1157264.xls
e4cdfd43-2701-4d45-8180-cc4bcc783049.html
tenderdocument.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days