Shipping Boards / Undertakings / PSU Closing in 3 days TDR #57622814

Tender For Main Switch Board Works On Orv Samudra Ratnakar

Issued by Boards / Undertakings / PSU · Visakhapatanam, Andhra Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Sep 2026
3 days left
EMD
50000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Main Switch Board Works On Orv Samudra Ratnakar

BOQ

Name of Work:- Main Switch Board Works on ORV SAMUDRA RATNAKAR
Sl. No. Item Description
1Main Switch Board Works on ORV SAMUDRA RATNAKAR
2440 V MAIN SWITCH BOARD TO BE CLEANED WITH DRY COMPRESSED AIR AND ELECTRIC CLEANER. ALL BUS BAR CONNECTIONS AND ALL CABLE CONNECTIONS TO BE CHECKED FOR TIGHTNESS. TO CARRY OUT MEGGER TEST OF MAIN SWITCH BOARD. AUTOMATION SYSTEM IN PANEL NEEDS TO BE CHECKED & SERVICED FOR PROPER OPERATON. 13 Nos of AIR CIRCUIT BREAKERS MAKE HYUNDAI HiAN (1600 Amps -1 No, 2500 Amps - 1 No, 3200 Amps - 2 No. 4000 Amps - 1 No, 800 Amps - 8 Nos) OVERHAULING. Make: ABB SCAE Emax E3, Amps: 2500 Amps, 440 V, 60 Hz. ALL BREAKERS TO BE TESTED FOR OVER CURRENT TRIP, REVERSE CURRENT TRIP, UNDER VOLTAGE TRIP, PREFRENTIAL AND SHORT CIRCUIT TRIPS IN PRESENCE OF SURVEYORS. AFTER OVERHAULING AND CALIBRATION. SATISFACTORY TRIALS TO BE SHOWN TO SHIP STAFF AND REPORTS TO BE SUBMITTED.
3690V AC MAIN SWITCH BOARD TO BE CLEANED WITH DRY COMPRESSED AIR AND ELECTRIC CLEANER. ALL BUS BAR CONNECTIONS AND ALL CABLE CONNECTIONS TO BE CHECKED FOR TIGHTNESS. TO CARRY OUT MEGGER TEST OF MAIN SWITCH BOARD. AUTOMATION SYSTEM IN PANEL NEEDS TO BE CHECKED & SERVICED FOR PROPER OPERATON. AIR CIRCUIT BREAKER OF 690V SWITCHBOARD TO DISMANTLE AND TO CLEAN WITH COMPRESSED AIR. AUTOMATION SYSTEM IN PANEL NEEDS TO BE CHECKED & SERVICED FOR PROPER OPERATON. 11 NOS OF AIR CIRCUIT BREAKERS MAKE - ABB SACE Emax E3 TTL TO TEST FOR OVER CURRENT TRIP, REVERSE CURRENT TRIP, UNDER VOLTAGE TRIP, PREFRENTIAL AND SHORT CIRCUIT TRIP IN PRESENCE OF SURVEYORS. AFTER OVERHAUL/SERVICE & CALIBRATION SATISFACTORY TRIAL TO BE SHOWN AND REPORTS TO BE SUBMITTED.
4EMERGENCY SWITCHBOARD 440 V SITUATED ON DECK - A TO BE THOROUGHLY CLEANED BY DRY AIR AND ELECTRIC CLEANER. ALL BUS BAR CONNECTIONS AND ALL CABLE CONNECTIONS TO BE CHECKED FOR TIGHTNESS. MEGER TEST TO BE CARRIED OUT. AUTOMATION SYSTEM IN PANEL NEEDS TO BE CHECKED & SERVICED FOR PROPER OPERATON. 03 NOS OF AIR CIRCUIT BREAKERS OVERHAULING MAKE: HYUNDAI HiAN 08, AMPS: 800 TO BE TESTED FOR OVER CURRENT TRIP, REVERSE CURRENT TRIP, UNDER VOLTAGE TRIP, PREFRENTIAL AND SHORT CIRCUIT TRIPS IN PRESENCE OF SURVEYORS. AFTER OVERHAULING AND CALIBRATION. SATISFACTORY TRIALS TO BE SHOWN TO SHIP STAFF AND REPORTS TO BE SUBMITTED.
5440V AC MAIN SWITCH BOARD CLEANED BY DRY AIR AND ELECTRIC CLEANER. ALL BUS BAR CONNECTIONS AND ALL CABLE CONNECTIONS TO BE CHECKED FOR TIGHTNESS. MEGER TEST TO BE CARRIED OUT. AUTOMATION SYSTEM IN PANEL NEEDS TO BE CHECKED & SERVICED FOR PROPER OPERATON. 05 NOS ACB OVERHAUL MAKE: HYUNDAI HiAN 16 AMPS: 1600 NO. OF ACB: 1 NO. MAKE: HYUNDAI HiAN 32 AMPS: 3200 NO. OF ACB: 2 NO. MAKE: HYUNDAI HiAN 40 AMPS: 4000 NO. OF ACB: 1 NO. MAKE: HYUNDAI HiAN 08 AMPS: 800 NO. OF ACB: 1 NO TO BE TESTED FOR OVER CURRENT TRIP, REVERSE CURRENT TRIP, UNDER VOLTAGE TRIP, PREFRENTIAL AND SHORT CIRCUIT TRIPS IN PRESENCE OF SURVEYORS. AFTER OVERHAULING AND CALIBRATION. SATISFACTORY TRIALS TO BE SHOWN TO SHIP STAFF AND REPORTS TO BE SUBMITTED.
6230V AC MAIN SWITCH BOARDS & SCIENTIFIC SWITCH BOARDS TO BE CLEANED BY DRY AIR AND ELECTRIC CLEANER. ALL BUS BAR CONNECTIONS AND ALL CABLE CONNECTIONS TO BE CHECKED FOR TIGHTNESS. MEGER TEST TO BE CARRIED OUT. ALL INDICATION LAMPS TO BE CHECKED & ENSURE ALL REQUIRED GLOWLY PROPERLY. AUTOMATION SYSTEM IN PANEL NEEDS TO BE CHECKED & SERVICED FOR PROPER OPERATON. 03 NOS ACB OVERHAUL: MAKE: HYUNDAI HiAN 08 AMPS: 800 NO TO BE TESTED FOR OVER CURRENT TRIP, REVERSE CURRENT TRIP, UNDER VOLTAGE TRIP, PREFRENTIAL AND SHORT CIRCUIT TRIPS IN PRESENCE OF SURVEYORS. AFTER OVERHAULING AND CALIBRATION. SATISFACTORY TRIALS TO BE SHOWN TO SHIP STAFF AND REPORTS TO BE SUBMITTED.
74 NO. AIR CIRCUIT BREAKER FOR 690V AC MDG ON MAIN SWITCH BOARD 1NO. AIR CIRCUIT BREAKER FOR EMERGENCY GENERATOR ON EMCY' SWITCH BOARD AND 1 NO. AIR CIRCUIT BREAKER FOR HARBOUR GENERATOR TO BE TESTED FOR OVER CURRENT TRIP REVERSE CURRENT TRIP UNDER VOLTAGE TRIP PREFRENTIAL AND SHORT CIRCUIT TRIP IN PRESENCEOF CLASS SURVEYORS. AFTER OVERHAUL SATISFACTORY TRIAL TO BE SHOWN AND REPORT TO BE SUBMITTED.
8SWITCH BOARD ROOM PANEL SHOULD BE CLEANED AND SERVICED. HYUNDAI BREAKERS AUTO CLOSE/OPEN FUNCTION TO BE REPAIRED ABB ACB AND OTHER BREAKERS NEED TO CHECK THE SAME. AUTOMATION SYSTEM IN PANEL NEED TO REPAIR.ABB ACB-400/140A 110….125V 50/60HZ. SATISFACTORY TRIAL TO BE SHOWN TO SHIP STAFF AND REPORT TO BE SUBMITTED.
9BATTERY CHARGING AND DISTRIBUTION BOARD SHOULD BE CHECKED FOR GROUND FAULT AND SERVICING TO BE CONDUCTED AC230V/3PH/60HZ DC24V/60A. SATISFACTORY TRIAL TO BE SHOWN TO SHIP STAFF.
10HYUNDAI HiAN 08; In=800A Ui=1000V 50/60HZ 3POLES Uimp=12kv AIR CIRCUIT BREAKER SERVICING TO BE DONE AND REPORT TO BE SUBMITTED.
11Note:1. All the tools, special tools, tackles are required for the above job shall be covered in contractor scope.2. All Consumables covered in Contractors Scope. Cost quoted in service scope of work only.3. Period of Completion: 24 Days.4. Any Increase / Decrease in the quantity shall be paid on pro-rata basis as per the rate. 5. On completion of work, offer for final survey, satisfactory completion of works in position to be shown to HSL are covered in contractor's scope. 6. All in way jobs/associated jobs required for the scope of work to be considered in the quotation. Hence additional quotation shall not be entertained. 7. The quote shall be exclusive of Applicable Taxes and the same to be shown against the above column.8. Besides the above, all HSL Standard terms & Conditions shall apply. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57622814
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 25-09-2026
Authority
Authority Name Hindustan Shipyard Limited
Work Description Tender for Main Switch Board Works On Orv Samudra Ratnakar
Basic Detail
Tender No SR COMPLEX/PRODUCTION/OUT SOURCE REQUISITION/2026/367
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 21 Sep 2026
Submission Date 25 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 50000
Exemption Available
Document List
53f54b8d-19ba-4ace-9683-09cdf4d06d57.html
BOQ_109737.xls
Tender-doc_367_1.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

53f54b8d-19ba-4ace-9683-09cdf4d06d57.html

xls

BOQ_109737.xls

rar

Tender-doc_367_1.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders