Defence Statutory Bodies & Commissions/Committees Closing in 22 days TDR #57622621

Tender For Special Repair To Hanger Sub Station & Base Ops Sub Station Area, Fencing & Gate 11 Kv Switch Yards At Af Staton Car Nicobar.

Issued by Statutory Bodies & Commissions/Committees · nicobar, Andaman And Nicobar Islands
Tender Value
47.83 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
22 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
nicobar → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Hanger Sub Station & Base Ops Sub Station Area, Fencing & Gate 11 Kv Switch Yards At Af Staton Car Nicobar.

BOQ

Name of Work:- SPECIAL REPAIR TO HANGER SUB STATION & BASE OPS SUB STATION AREA, FENCING & GATE 11 KV SWITCH YARDS AT AF STATON CAR NICOBAR.
Sl. No. Item Description
1Dismantling of old UNSV HT 4 pole structure all as specified and as directed by Engr-in-Charge.
2Taking out of old UNSV HT/LT UG cables any size and type all as specified and as directed by Engr-in-Charge.
3Supply, installation, connecting, testing and commissioning in replacement of old conventional type 4 pole structures and fuse units outdoor type 11 KV, 630 Amps, Non Extensible type, outdoor fixed type (IP54), RMU (Ring Main Unit) 6 way comprising of 06 Nos 630 Amp Vaccum circuit breaker. Incomer 3 Nos & 03 Nos outgoing. Inside robotically/ manually/TIG welded sailnless steel 304 (Non ferrite Non magnetic Grade) filled with SF6 gas at suitable pressure in accordance with the IEC, IEC-62271-103, tank having min thickness 3 (+/-) 0.5 mm having IP 67 degree of protection. The RMU tank shall provide full insulation, making the switchgear insentive to the environment with degree of protection of IP67. The RMU shall be suitable for operations at a height 1000m above sea level and at 40 degree ambient temperature without any derating. RMU should be provided with internal busbar as well as earthing busbar should be copper, padlock provisions & complete all accessories. The RMU shall be type tested for internal arc test of 21KA/0.1 Sec as per IEC-62271-200. RMU shall be equipped with site replaceable bushing. The earthing busbar shall be provided inside the each cable compartment for solid earthing of cable sheilds. The outer enclosure main door should cover entire part of the switchgear including front cover and cable doors for providing complete IP54 protection including raised foundation of suitable size, minimum 50cm above and 01 meter below the natural ground level all as per manufacturers drawing. The unit shall include the following along with all necessary accessories and fittings as required at site all as speciffied & directed by Engr-in-Charge.
4Note :- (i) Contractor shall submit the drawing alongwith technical specifications prior to purchase order for approval of accepting Officer. (ii) RMU Shall suitable for the locations having max ambient temp upto 55 degree celsius max relative humidity upto 100% max annual rain fall 200mm, seismic zone No 5, Climatic condition hot and humid (Tropical). (iii) RMU shall comply with standards of IEC 62271-200/IEC 60 298/IS 12729 : 1998, IEC 60129/IEC 62271-102/IS 9921, IES 60056/IS 13118:1991. (iv) Switch gear shall be designed such that the position of the different devices shall be visible to the operator on the front of the switch board easy to operated and prevent acess to all live parts during operation without the use of tools. There shall be no access to exposed conductors. (v) The SF6 gas shall comply with IEC 376, 376A, & 376B and shall be suitable for use in RMU under stipulated conditions. (vi) The SF6 tank shall be robotically welded stainless steel sheet of min thickness 3 (+/-) 0.5 mm and shall be sealed and no handling of gas required for 20 years of life span. Degree of protection of inner tank shall be of IP-67 (vii) The circuit breaker unit fitted with 3 x protection CTs (tape wound) of ratio 100-50A/1A, 5P10 class having low burden and trip coil and trip coil auxiliary switch assembly allowing the use of a self powered non directional IDMT (Inverse Definite Minimum Time) over current and earth fault relay of micro processor based Over Current setting variable from 10% to 200% while Earth Fault elements setting shall be veriable from 10% to 40%. The protection curves and all parameters shall be adjustable from touch panel. (ix) Contractor shall impart training to MES operators through OEM recommended technicians for operations and maintenance till the satisfaction of Engineer-in-Charge without any extra cost.
5(a) Incommer:- SF6 insulated motorized Breaker module consisting of following accessories:-(i) 11 KV, 630 Amp fixed type Vaccum Circuit Breaker module for making and breaking of fault current along with disconnector + Earth switch and interlocking facility.(ii) Short time current-21KA/3 Sec, breaking capacity 52.5 KA.(iii) Auxiliary contacts-01 NO+ 2 NC & Auxiliary contact on earth switch is 1 NO + 1 NC.(iv) Stored energy machnism with manual / motorized spring charging. associated closing/ tripping coils, integrated non removable spring charging operating handle and ON/OFF push buttons mechnically latched to the mechanism.(v) Interlocked, arc prrof cable box for front termination of the cable suitable door arrangement (IP 54+ IP3X & IP2X) safety interlocked to prevent access to cable termination in live condition.(vi) Numarical based self powered OC + EF protection relay, providing over current (Min setting 20%). Earth fault (Min setting 10%).
6(vii) Resign cast, Ring core CTs of suitable capacity for protection (ACC.CI, 5P10). 2.5 VA, incoming100/1 & outgoing 50/1, insulatted away from bushing to prevent saturation of core -set of 3 No.(viii) Potential transformer with HT fuse on primary side and MCB on secondary side for protection and primary voltage 11000 V3v & secondary voltage 110 V3v with burden winding 5 VA, class of winding 1:10.(ix) Digital multi function meter with Rs-485 port (A,V, KW, KVA, KWH, PF) etc.(x) Suitable site replaceable cable busings suitable not beyond 300mm from cable cover to allow ease of access for installation/ testing/ replacement purpose.(xi) Self interlocking mechanism between door, earth swich, disconnector and VCB.(xii) Capacitive voltage indication fixed type system.(xiii) Mchnical indications for breaker ON, OFF, Earth, Spring charged- Discharged.(xiv) Mechanical interlock between incomers.(xv) Battery 24 Volt ,7AH along with battery chargers.
7(b) Outgoing:- SF6 insulated motorized Breaker module consisting of following accessories:-(i) 11 KV, 630 Amp fixed type Vaccum Circuit Breaker module for making and breaking of fault current along with disconnector + Earth switch and interlocking facility.(ii) Short time current-21KA/3 Sec, breaking capacity 52 KA.(iii) Auxiliary contacts-01 NO+ 1 NC.(iv) Stored energy mechanism with manual / motorized spring charging. associated closing/ tripping coils, integrated non removable spring charging operating handle and ON/OFF push buttons mechanically latched to the mechanism.(v) Interlocked, arc proof cable box for front termination of the cable suitable door arrangement (IP 54+ IP3X) safety interlocked to prevent access to cable termination in live condition.(vi) Emergency trip push button.
8M&L for laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm 3 core .
9Supply and laying in trenches HDPE double wall corrugated pipe (DWC) conforming to IS 16098-2 SN 4 Class of size 65 mm outer dia with sol fit pipe joint complete all as specified and as directed by Engr-in-Charge.
10M&L in replacement of cable jointing kit for or 3 core XLPE armoured aluminium conductor cable of size 95sqmm heat shrink type indoor end termination all as specified and directed by Engr-in-Charge.
11M&L sub base cement concrete of 100mm thick, type D-2 1:4:8 (40mm graded aggregate) including formwork, screed strips and to divide the area in panels etc all as specified and directed by Engr-in-Charge.
12M&L sub base cement concrete of 100mm thick, Cement concrete type B-1, 1:2:4 (20mm graded aggregate) including formwork, screed strips and to divide the area in panels etc all as specified and directed by Engr-in-Charge.
13M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface around the 4 pole structures, RMU switchgear, transformer basement etc all as specified and as directed by Engineer-in-Charge.
14Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft /loose complete all as specified and as directed by Engr-in-Charge.
15Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed by Engr-in-Charge.
16Removing excavated material from the site to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified by Engr-in-Charge.
17M&L for demolition of path/road in ground floors and pavings exc 15 cm thickness (below or above ground level) road cutting etc all as specified and directed by Engr-in-Charge.
18M&L for cement concrete PCC 1:3:6 type C-2 using 40mm graded stone aggregate in filling foundations and mass concrete including plastering and finishing & necessary formwork foundation of post complete all as specified and as directed by Engr-in-Charge.
19M&L for earthing complete with Copper earth plate electrode of size 600mmx600mmx3.15mm, buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtrs deep below normal ground level, connected to copper earth strip of size 20x3 mm by means of brazing and connected to earthing test point / distribution board/equipment's or any other indicated situation by means of brazing all as shown in electrical plate No.3 of SSR Part I (2009) and testing on completion including necessary excavation and earth work in any type of soil, returning filling, removing of soil, GI medium grade pipe 20 mm dia 1.5 mtr long with funnel and wire mesh as watering pipe, and GI medium grade pipe 32mm dia as earth lead protection pipe.Earth pit chamber made of PCC 1:2:4 type B1 using 20mm graded stone aggregate including 40mm thick chamber cover made of 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 100 c/c on both ways precast chamber cover with lifting handle 16mm dia round bars including charcoal and common salt in alternate layer of 15cm thick covering all faces of earth electrode plate, including taking down old one, complete all as specified and directed by Engr-in-Charge.(Note :- (i) The rates quoted for the complete earthing shall deemed to include the cost of 20X3 mm copper strip and GI medium grade protection pipe up to 7.5 Mtrs.(ii) Copper Strip and GI medium grade protection pipe beyond 7.5 Mtrs length shall be measured and paid separately.
20Excavating in post holes (or similar holes) in soft/loose soil each n. exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm. trenches n.exc. 1.5m wide and n.exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc. n exc. 10 Sqm on plan and n exc. 1.50m in depth and getting out soft/loose soil.
21M&L for plain cement concrete type C-2 1:3:6 (40 mm graded aggregate) in foundation filling and mass concrete all as specified and directed by Engr-in-Charge
22S&F in replacement of angle iron posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc, simmilar work conforming to Fe-290 Gde E-165 complete all as specified and directed. Note :- Size of angle shall be as per standard drgs complete all as specified and directed by Engr-in-Charge.
23Supply only in replacement of 3.15 mm dia chain link MS galvanised fencing of size 100 x 100mm complete all as specified and directed. Note : MS wire covered with PVC insulation to prevent corrosion.
24Fixing only chain link fencing including line wires, any mesh, size and type to any type of starandards, rails straining bolts, etc including provision of binding wire all as specified and directed by Engr-in-Charge.Note : MS wire covered with PVC insulation to prevent corrosion.
25S&F in replacement of Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long Diameter of shank in 5 to 10 mm all as specifed and directed by Engr-in-Charge.
26M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge
27S&F in replacement of Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for securing chainlink fenciing fixed to RCC fencining post as directed by Engr-in-Charge.
28S& F in replacement of Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 290 Gde E-195 all as specified and as directed by Engr-in-Charge.
29Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out soft and loose soil .
30M&L for Hardcore of guage n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified and as directed by Engr-in-Charge.
31M&L 100mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate in floors, laid in panels and finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
32M&L for Sand filling under floors or in foundations including watering and consolidation as required all as specified and directed by Engr-in-Charge.
33S&F Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and directed by Engr-in-Charge.
34M&L for Pre-cast cement concrete block masonry with solid blocks using type C1(1:3:6) (20mm graded aggregate) ,size exc 10cm in width and setting in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
35M&L for rendering 10mm thick over concrete surface by using cement plaster of ratio 1:4 in floor and walls including finishing the surface fair and even including curing after rendering complete all as specified and directed by Engr-in-Charge.
36M&L for distempering on wall with oil emulsion based paint and subsequent coat over first coat complete including preparation of new plastered surfaces all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57622621
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.83 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Hanger Sub Station & Base Ops Sub Station Area, Fencing & Gate 11 Kv Switch Yards At Af Staton Car Nicobar.
Basic Detail
Tender No 81008/E8
Bidding Type Tender
Location
City nicobar
State Andaman And Nicobar Islands
Key Dates
Publish Date 21 Sep 2026
Submission Date 14 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 47.83 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
2d593009-58e2-4781-be0c-679201414cdd.html
BOQ_885355.xls
Tender.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

2d593009-58e2-4781-be0c-679201414cdd.html

xls

BOQ_885355.xls

pdf

Tender.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders