Public Administrative Department Local Bodies Closing in 7 days TDR #57622534

Tender For Provision Of 20 M Height 2 Hm Pole With Led Lights In Shaheed Bhaghat Stadium In Mangolpuri, Ward No.49 Under Rohini Zone.

Issued by Local Bodies · Delhi, Delhi
Tender Value
14.96 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
7 days left
EMD
29950
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of 20 M Height 2 Hm Pole With Led Lights In Shaheed Bhaghat Stadium In Mangolpuri, Ward No.49 Under Rohini Zone.

BOQ

Name of Work:- Provision of 20 M height 2 HM Pole with LED Lights in Shaheed Bhaghat stadium in Mangolpuri, Ward no.49 under Rohini Zone.
Sl. No. Item Description
1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2Providing and fixing 25mm x 5mm GI strip on surface or in recess for connections etc as req.
3Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required Upto 35 sq. mm
5Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
6Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
7Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm
8Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
9Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp
10Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required..100 A,36KA,FPMCCB
11Supply of 20 Mtr. high mast system with its accessories (as per IS:875 part-1-2015/BSEN10025 and IS:2062), Mast shall be in two section, hot dip galvanized inside and outsides as per IS 4759/BSEN 1461 and suitable for wind velocity as per IS 875 (part-3) 1987. lantern carriage suitable for up to 6 nos asymmetrical loaded luminaries with welded arm (excluding luminaries), mast head frame assembly with full cover, suitable for 1 No. LED aviation obstruction lights, double drum type self sustaining winch, integral power tool accessible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanized heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 construction 2 no. rope for lantern carrage & 2 no. rope for winch assembly ), torque limiter, reverse / forward motor operation. The mast cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc with 12 nos. foundation bolt, M30*850 mm long, i/c 2 nos. Anchor plate of size 670mm dia, 3 mm thick as required. 20 Mtr height, bottom thickness 4 mm & top thickness 3 mm, bottom dia. 460 mm & top dia. 150 mm with base plate dia. 670 mm & 30 mm thick. Logo/Name of manufacturer shall be embossed on the pole.
12Design and casting of shallow foundation with M20 grade concrete for erection of 20 Mtr highmast considering the safe soil bearing capacity at site as 10T/sqmtr in any type of soil area including placing foundation bolts. Straitening , cutting, bending and placing in position reinforcement base, column & rings strictly as per bar bending schedule and drawing complete as required by Engineer-in-charge with all material and labour etc. as reqd.
13Erection of 20 Mtr high mast with the help of suitable tools and plant, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sqmm, connections, joints, lugs, MCB, isolator and labour etc as required.
14LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 degto 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 250 Watt
15S/I/T/C of 12W LED single dome aviation obstruction light made of die-cast aluminum alloy housing with polycarbonate with following specification (a) Protection class-65 (b) Color- Red.
16Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size 25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd.
17Providing and fixing of Stainless steel name plate of size 6&8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
18Providing and fixing name board made of MS sheet 90*60 cm,1mm thick with frame of MS angle 50*50*6mm, two diagonal braces at bthe back of the sheet of MS flat 40*6mm ,total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4(1 cement:coarse sand:4 graded stoneaggegate 20mm nominal size) 30*30*45 cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer,painting with syntheic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in -charge.
19Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level, 1:3:6 (1 Cement: 3 coarse sand (zone-III) drived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources.
20SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection,erection of switchgears with depth 30 cm to 60cm and making provisions for termination ofincoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
21Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57622534
AUTHORITY Local Bodies
TENDER VALUE 14.96 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of 20 M Height 2 Hm Pole With Led Lights In Shaheed Bhaghat Stadium In Mangolpuri, Ward No.49 Under Rohini Zone.
Basic Detail
Tender No EEE-III/RZ/TC/2026-27/21.4
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 21 Sep 2026
Submission Date 29 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 14.96 Lakhs
Tender Fee 590
EMD 29950
Exemption Not Available
Document List
20MTRHM08LIGHTASYMM.pdf
20MTRHMFDN08LIGHTASYMM.pdf
20MTRHMTDS08LIGHTASYMM.pdf
BOQ_340046.xls
d67ec3f1-fbd1-4904-a1f1-0325927a0657.html
GeneralConditions2026.pdf
MCD_GCC_2026Latestcirculars.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

20MTRHM08LIGHTASYMM.pdf

pdf

20MTRHMFDN08LIGHTASYMM.pdf

pdf

20MTRHMTDS08LIGHTASYMM.pdf

xls

BOQ_340046.xls

html

d67ec3f1-fbd1-4904-a1f1-0325927a0657.html

pdf

GeneralConditions2026.pdf

pdf

MCD_GCC_2026Latestcirculars.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders