Tender For Special Repair To Toilet Of Building Number P-276 (Sm Barrack) Of Armed Regt At Jalipa Mil Stn Under Ge (A) Barmer[Job No. (I)- 07/Bldg/Jlp/2025-26
Tender Value
36.65 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
15 days left
EMD
73300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Toilet Of Building Number P-276 (Sm Barrack) Of Armed Regt At Jalipa Mil Stn Under Ge (A) Barmer[Job No. (I)- 07/Bldg/Jlp/2025-26
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work of stone/boulder/PCC block masonry, build in cement mortar including all for ashlars facings, dressed stonework, precast concrete articles and precast concrete block walling |
| 2 | M&L for Type C1 1:3:6 (20 mm graded aggregate) Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engineer-in-charge. |
| 3 | Taking down cement plaster of any description, any thickness from surfaces of walls/soffits of roof projections & chajjas /ceilings etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed. |
| 4 | M&L for Ready mix plaster in cement mortar ( 1:6) , 15mm thick on wall surface of brick or PCC block or stone surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M & L for Ready mix plaster ,5 mm thick in CM (1:3) on ceiling surfaces finished even and smooth without using extra cement, complete, all as specified and directed. |
| 6 | M&L for preparing new plastered or unplastered surfaces of walls, and applying three coats of white wash complete all as specified and directed. |
| 7 | M&L for complete removal of existing treatment, plastered or unplastered old surfaces of walls, including filling of cracks/holes by crack filler, removing unnecessary nails and applying three coats of white wash complete all as specified and directed. |
| 8 | M&L for complete removal of existing treatment, plastered or unplastered old surfaces of ceiling, including filling of cracks by crack filler, removing unnecessary nails and applying three coats of white wash complete all as specified and directed. |
| 9 | M&L for preparing new plastered or unplastered surfaces of ceiling, and applying three coats of white wash complete all as specified and directed. |
| 10 | M&L for special treatment to floor/slab/wall sunken portion with demolition of PCC with plaster of entire sunken area (bottom, sides & top upto dado level), removal of floor trap and soil pipes including removal of demolished material exc 500m and n exc 1000m, fix the soil pipe, 20mm dia 200mm projected GI spout pipe through wall fill the gap between pipe and left out opening with PCC Type B0, 1:2:4 with using WPC cleaning to remove loose particles, dust, latance with brush etc of entire surface properly, applying 10mm thick plaster in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, on the bottom/slab and sides/beams/walls upto dado level of sunken area, prepration of surface and applying one coat each of Nitoproof 100 priming coat @1Ltr/4Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2Sqm, after drying of surface fill the sunken area with water for 24 hrs for the testing of leakage/seepage if leakage/seepage not observed, filling the sunken floor/area with PCC (1:5:10) using brick bat mixed with WPC liquid Conplast 421 as per manufacurer's instructions,, including placing of 75mm new CI floor trap, rendering again 40mm thick in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, over PCC/ top area, applying 10mm thick plaster in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, on the 40mm thick rendering, and applying one coat each of Nitoproof 100 priming coat @1Ltr/4Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2Sqm over 10mm thick rendering/top surface, area of floor exc 1.20Sqm but n exc 2.00Sqm complete all as specified and as directed.Note : Nitoproof 100/120 and WPC Conplast - 421 will be used of Fosroc or Equivalent make. |
| 11 | M&L for special treatment to floor/slab/wall sunken portion with demolition of PCC with plaster of entire sunken area (bottom, sides & top upto dado level), removal of floor trap and soil pipes including removal of demolished material exc 500m and n exc 1000m, fix the soil pipe, 20mm dia 200mm projected GI spout pipe through wall fill the gap between pipe and left out opening with PCC Type B0, 1:2:4 with using WPC cleaning to remove loose particles, dust, latance with brush etc of entire surface properly, applying 10mm thick plaster in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, on the bottom/slab and sides/beams/walls upto dado level of sunken area, prepration of surface and applying one coat each of Nitoproof 100 priming coat @1Ltr/4Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2Sqm, after drying of surface fill the sunken area with water for 24 hrs for the testing of leakage/seepage if leakage/seepage not observed, filling the sunken floor/area with PCC (1:5:10) using brick bat mixed with WPC liquid Conplast 421 as per manufacurer's instructions,, including placing of 75mm new CI floor trap, rendering again 40mm thick in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, over PCC/ top area, applying 10mm thick plaster in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, on the 40mm thick rendering, and applying one coat each of Nitoproof 100 priming coat @1Ltr/4Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2Sqm over 10mm thick rendering/top surface, area upto 0.25Sqm complete all as specified and as directed.Note : Nitoproof 100/120 and WPC Conplast - 421 will be used of Fosroc or Equivalent make. |
| 12 | M&L for special treatment to floor/slab/wall sunken portion with demolition of PCC with plaster of entire sunken area (bottom, sides & top upto dado level), removal of floor trap and soil pipes including removal of demolished material exc 500m and n exc 1000m, fix the soil pipe, 20mm dia 200mm projected GI spout pipe through wall fill the gap between pipe and left out opening with PCC Type B0, 1:2:4 with using WPC cleaning to remove loose particles, dust, latance with brush etc of entire surface properly, applying 10mm thick plaster in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, on the bottom/slab and sides/beams/walls upto dado level of sunken area, prepration of surface and applying one coat each of Nitoproof 100 priming coat @1Ltr/4Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2Sqm, after drying of surface fill the sunken area with water for 24 hrs for the testing of leakage/seepage if leakage/seepage not observed, filling the sunken floor/area with PCC (1:5:10) using brick bat mixed with WPC liquid Conplast 421 as per manufacurer's instructions,, including placing of 75mm new CI floor trap, rendering again 40mm thick in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, over PCC/ top area, applying 10mm thick plaster in CM (1:4) mixed with WPC liquid Conplast 421 as per manufacurer's instructions, on the 40mm thick rendering, and applying one coat each of Nitoproof 100 priming coat @1Ltr/4Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2Sqm over 10mm thick rendering/top surface, area exc 2.00Sqm complete all as specified and as directed.Note : Nitoproof 100/120 and WPC Conplast - 421 will be used of Fosroc or Equivalent make. |
| 13 | Demolition of cement concrete(unreinforced ) in ground floors and pavings not exceedidng 15cm thickness (below ;or aboved ground level), removal of debris outside MOD land, complete all as specified and directed. |
| 14 | M&L For 25 mm thick, type B-1, 1:2:4 (20mm graded aggregate) as in sub base etc complete all as specified and as directed. |
| 15 | Demolition of stone slabs and tiles, ceramic tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and as as directed. |
| 16 | M&L for Glazed ceramic tiles (coloured tiles) in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in CM (1:4) and pointed in coloured cement to match complete all as specified and directed. |
| 17 | M&L for non skid ceramic tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.06 but n exc 0.11 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:4) complete all as specified and directed. |
| 18 | M&L for Machine cut kota stone slab flooring 20-25mm thick over 15mm thick screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing to give high gloss finish complete complete all as specified |
| 19 | M&L for Kota stone slab 20-25mm thick Mirror polishing to give high gloss finish in riser of steps, skirting, dado and pillar laid over 10mm thick backing coat in CM (1:4) and jointed complete all as specified. |
| 20 | M&L for Kota stone slab 20-25mm thick (in single piece as vertical support and horizointal base for granite top) in cooking platform, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and as directed. |
| 21 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms,wash basin base,urinal partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and as directed. |
| 22 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified. |
| 23 | Taking down chowkats or frames (without taking of shutters from the frames) area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed . |
| 24 | Taking down chowkats or frames (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified and as directed . |
| 25 | S&F of WPC [Wood Polymer Composite] Door Frame of 100 x 65 single extruded comprising of vingin PVC polymer ofK value 58-60 [suspension grade] Calcium Carbonate and mmn section natural Fibers [wood powder ice huskwheat husk] and non toxic additives (maximum toxicity index 12 for 100 gms fabricated with meter joints atter applving PVC solvent cement and screwed wvith full screws having mìnimum franme density of 750 kg/cum screw withdrawal strength 2200 N [face] & 1100 headed Ss N[edge).minimum compressive strenght of 58 N/mm2 modulus of elasticity 900N/mm2 and resistance to spread of iflame of Class A Category with properties of being termite borer proof, water/moisture proof and fire retardant and fxed in /mm2, position with MS hold fast fasteners of required dia and length complete as per direction of engr-in-charge. |
| 26 | S&F of single extruded WPC(wood Polymer Composite]) Plain 30 mm Thick door shutter of size 6.5 x 2.5 fect comprising of virgin polymer of K value 58-60 [suspension gradel. CalciumCarbonate Saural Fibers [wood powder/rice husk/wheat husk] and non toxic additives (maximum toxicity index 12 for 100gms) having density 600 kg/cum and screw withdrawal strength of 1800 N[ face] & 900 N [edgel. minimum nssive strength 50 N/mm2, modulus of clasticity 850 N/mm2 and resistance to spread of flame of Class A Cry with property of bcing termite/borer proof, water /moisture proof and fire retardant and fixing with tainless stecl but hinges of required size with necessary full body threaded star headed counter Sunk S.S serews all as per specification and direction of Engineer-in-Charge. |
| 27 | S&F for solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specifications complete all as specified and as directed . |
| 28 | S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of framemade out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and as directed. |
| 29 | S&F of Aluminium powder coated ventilators partly fix and partly lowered of aluminium section designed DG-2762 (40 mm x 32 mm x1.5 mm thick) (wt 0.668 kg/mtr) frame and DG-2763 and middle section of designed DG-2763 (40 mm x 32 mm x 1.5 mm thick) (wt 0.654 kg/mtr), middle section DG-2546 (17.27 mm x 17.15 mm x 1.22 mm thick) (wt 0.124 kg/mtr) including 5 mm thick pinheaded figured glass louvers with blades of 100 mm heavy duty including with aluminium lever handle fixed panel shall be provided with 5 mm thick pin headed figured glass including all necessary rubber packing, anodized aluminium snap beading fixed with minimum 6 Nos of suitable size galvanised screws with PVC plug etc including taking down old ventilator etc. complete all as specified and directed. |
| 30 | S&F for 100mm size SS butt hinges, medium weight, complete all as specified and as directed. |
| 31 | S&F for 150mm size SS barrel tower bolts of extruded section complete all as specified and as directed. |
| 32 | S&F for 150mm size SS handle complete all as specified and as directed. |
| 33 | M&L for 300mm size SS sliding door bolts with Hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or Stainless steel complete all as specified and as directed. |
| 34 | S&F for 140mm length aluminium floor door stoppers double legged with hard drawn steel spring fitted in floor complete all as specified and as directed. |
| 35 | Dismantling of water tanks (RCC hume Pipe/PVC) including disconnecting all connections etc. complete for following capacity of tanks Exc 500 and n exc 1000 ltrs. |
| 36 | S&F for new rotational moulded polythylene water storage tank 1000 ltr capacity (cylindrical/vertical with closte top) hoisted and fixed in position all as specified in SSR Part-I including providing and fixing ball brass valve high pressure with polythene float and fly nut, 20mm bore complete all as specified and directed. |
| 37 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and as directed. |
| 38 | Taking up or down 20mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and as directed. |
| 39 | Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed. |
| 40 | S&F for 16mm bore of CPVC of food grade pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 41 | S&F for 20mm bore of CPVC of food grade pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 42 | S&F for 25mm bore of CPVC of food grade pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 43 | Fixing only 15mm bore tubes, any grade, to walls and ceilings or laying in floors |
| 44 | Fixing only 20mm bore tubes, any grade, to walls and ceilings or laying in floors |
| 45 | Fixing only 25mm bore tubes, any grade, to walls and ceilings or laying in floors |
| 46 | S&F in repair 15mm bore CP fancy type stop valves/angle cock, cast copper alloy, screwed both ends for iron pipe or for union complete all as specified and as directed. |
| 47 | S&F in repair two way 15mm bore CP fancy type angle cock, cast copper alloy, screwed both ends for iron pipe or for union complete all as specified and as directed. |
| 48 | S&F in repairs 15mm bore stop valves, angle cock, cast copper alloy, chromium plated with long shank and cup (concealed type) complete all as specified and as directed. |
| 49 | S&F in repair 15mm bore Bib taps CP fancy type, cast copper, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 50 | S&F in repair 15mm bore two way Bib taps (for health faucet/jet spray) fancy type, chromium plated, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 51 | S&F in repairs 15mm bore pillar taps long body, cast copper alloy with capstan heads, chromium plated,fancy type screwed down high pressure with or without lettered “HOT” or “COLD” with long screwed shanks and fly nuts complete all as specified and as directed. |
| 52 | S&F in repair Brass chromium plated shower rose 125mm size complete all as specified and as directed. |
| 53 | S&F in repair Jet Spray (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.00 metre long flexible tube including making connections and fixed in position complete in all respect complete all as specified and directed. |
| 54 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect complete all as specified and as directed. |
| 55 | S&F in repair brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and as directed. |
| 56 | S&F in Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified. |
| 57 | S&F in repair SS soap dish, approximate size 150x 150x80mm, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 58 | S&F in repairs Liquid soap container of PTMT fixed with and including Chromium plated brassscrews and wooden/plastic cleats. (Minimum weight 105gms) complete all as specified and directed. |
| 59 | S&F in repair PVC valveless flushing cistern, low level white with inlet ball valve float and handle including brackets complete fixed capacity of flush 10 ltrs complete all as specified and as directed. |
| 60 | S&F in repair 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends as fixed in repairs complete all as specified and as directed.. |
| 61 | S&F in repair bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers with aluminiumn frame, complete all as specified and as directed. |
| 62 | S&F in repair sheet glass corner wall mounted shelf assembly consisting of 5.50 mm thick sheet glass 220mmX220mm size with chromium plated bracket guard and railing 50mm high complete all as specified and as directed. |
| 63 | S&F in repairs sheet glass shelf aasembly consisting of 5.50 mm thick sheet glass shelf 120 mm wide with chromium plated bracket guard and railing of 600 mm long complete all as specified and as directed. |
| 64 | S&F in rep vitreous china wash down water closet pan (pedestal pattern), white including P or S trap, connection to drain (or outgoing pipe) and to flushing pipe 32mm PVC with and including plastic water closet seat, white closed pattern with flat bottom, cover and mild steel hinges device complete all as specified. |
| 65 | S&F in repairs table top wash hand basins, vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand inclusive of fixing of supply and 32mm PVC waste pipe etc complete all as specified and as directed. |
| 66 | S&F in repair Vitreous China Urinal, Half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement;urinal water spreader, flush pipe, grating and coupling for waste pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) including waste pipe complete all as specified and as directed. |
| 67 | S&F PVC (SWR) bend any radius 110mm complete all as specified and directed. |
| 68 | S&F PVC (SWR) bend any radius 75mm complete all as specified and directed. |
| 69 | S&F PVC (SWR) bend any radius 110mm provided with access door complete all as specified and directed. |
| 70 | S&F PVC (SWR) bend any radius 75mm provided with access door complete all as specified and directed. |
| 71 | S&F in repairs 110 mm bore PVC [SWR] Junction single [single \\"T\\"] equal or unequal with access door complete all as specified and as directed. |
| 72 | S&F in repairs 75 mm bore PVC [SWR] Junction single [single \\"T\\"] equal or unequal with access door complete all as specified and as directed. |
| 73 | S&F in repair 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall with wall seperator clamps complete all as specified and as directed. |
| 74 | S&F in repair 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall with wall seperator clampscomplete all as specified and as directed. |
| 75 | S&F in repairs 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 76 | Cutting chases, holes in Brick walls, Stone walls, concrete block or slab walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth all as specified and as directed. |
| 77 | Formwork to sides of flat rough finished surfaces of concrete foundations, footings, bases of columns, columns, beams, slabs, roof slab, lintel, chajjas and similar work; (leak proof type) vertical, horizointal or to batter complete all as specified. |
| 78 | S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 79 | S&F for Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 80 | S&F for Mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 81 | M&L for Chipping of 50mm average thickness unsound/weak concrete material from slabs, beams, columns, footings etc. and plaster with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts complete. |
| 82 | M&L for Cleaning & applying rust remover on in two coats over rusted reinforcement surface of RCC members and providing anti corrosive coating with two component epoxy based zinc rich primer/Rust passivation Inhibitor coat at the rate of 2-3 sq. mtr/ltr not less than 50 microns dft to reinforcement surface as per manufacturer’s instructions including all machinery, tools tackles and clearing of debris.(Note : Entire Exposed Surface of RCC members after chipping shall be measured and paid.) |
| 83 | S&F of new steel or rebars by drilling holes with 10 mm to 25mm dia and 100 to 200mm deep/wide as per IS code of 10D formula and filling the holes after inserting of reinforcement dia 8 to 16mm for anchoring at ends/shear connector and filled the holes with one or two component styrene free vinylester resin anchor or two components, styrene & cement free epoxy- acrylate fixing and anchoring compound ( having the technical parameters mentioned in material specifications) using standard sealant applicator gun after drilling holes of required diameter at required locations, for holding / fixing / placing in position the steel mesh reinforcement at desired level/ stretching. (Note : Steel/reinforcement shall be paid and measured separately) . |
| 84 | M&L for providing Micro concrete thickness 25 to 30 mm M-50 (Minimum grade) with CICO MICROCRETE at the rate of 25kg per 0.0125 m3 with 20% properly graded 5mm to 10mm silt free aggregate as per manufacturer instructions and mixing concrete with mechanically electrically operated mixer machine, including all necessary scafolding if required etc all as specified and directed. Make: CICO MICROCRETE of CICO Technologies ltd or equivalent in Fosroc/STP/BASF. |
| 85 | M&L for providing Micro concrete M-50 (Minimum grade) at the rate of 25kg per 0.0125 m3 with 20% properly graded 5mm to 10mm silt free aggregate as per manufacturer instructions and mixing concrete with mechanically electrically operated mixer machine, including all necessary scafolding if required etc all as specified and directed. |
| 86 | M&L for Epoxy Bonding Agent suitable for bonding new to old concrete, bricks and steel components, bricks, tiles etc after the prepration of old concrete/RCC surface by cleaning and removing of dust, dirt, loose particles, laitance etc by wire brushing, scrapping and washing with water complete all as per manufacturer's instructions. |
| 87 | Taking down old, unsv aluminium/copper point wiring (light, fan, socket or power) complete, incl fixture & fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-Charge. |
| 88 | Disconnecting/dismantling of old existing un serviceable DB's along with metal enclosue concealed in walls of any type/way 240/415 Volts with their old/un serviceable burnt MCCB/MCB's etc.incl making good the disturbed surfaces and matching with existing surfces complete all as specified and directed by Engr-in-Charge. |
| 89 | Taking down old sub-main wiring incl fixture & fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-Charge. |
| 90 | Taking down exhaust fan and deposit the same to the MES store. |
| 91 | M & L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed. One Light point controlled by one switch 5/6 Amps. |
| 92 | All as per item No 91.00 here-in-above, but for one exhaust fan point controlled by one switch. |
| 93 | All as per item No 91.00 here-in-above, but for one 3/2 Pin 6 Amp socket out let point on the independent board. |
| 94 | All as per item No 91.00 here-in-above, but for one socket outlet 3/2 pin, 6 Amp, point on the same board with other switches. |
| 95 | All as per item No 91.00 here-in-above, but with wire 2.5 sqmm including 2.5 sqmm wire as earth wire for 15/16 amp socket point. |
| 96 | All as per item No 91.00 here-in-above, but with wire 4 sqmm including 4 sqmm wire as earth wire for 15/16 amp socket point. |
| 97 | Supply and fix Modular switch 1 way 6 A, 1 module. complete all as specified and directed |
| 98 | Supply and fix Modular Socket, 5A/6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 99 | Supply and fix Modular Socket, 6A/16A - 2/3 pin combined 2 modulecomplete all as specified and directed. |
| 100 | Supply and fix Modular switch 1 way 16 A, 1 module. complete all as specified and directed. |
| 101 | Supply and fix ceiling rose surface bakelite 65x50 mm two to three terminals. |
| 102 | Supply and fixing in replacement single pole 06 to 32 A rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing andcommissioning, complete all as specified and as directed |
| 103 | All as per Item No 128.00 here-in-above but SPN 32 to 40 A rating 'C' curve complete all as specified and as directed |
| 104 | S&F sheet metal enclosure, (for DB's when MCBs to be used), flushed in wall single pole and neutral Double door, 8 way, 240 Volts with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed. |
| 105 | Supply and fix exhaust fan 380 mm sweep with louvre steel body complete fixed to window/wall with suitable fastening and connecting up including provision of cable from connector to fan with flexible copper conductor cable 24/0.2mm and taking down the existing exhaust fan and deposit in MES store complete all as directed. |
| 106 | Cutting of brick/stone masonary for fixing of exhaust fan or passing of chimney duct and making good to the disturbed surface including painting/colour wash as directed by Engr-in-charge. |
| 107 | M&L sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length). |
| 108 | S & F in replacement LED batten suitble for indoor application 20 W, 4' length , wall mounted with aluminium housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge |
| 109 | S & F in replacement LED batten suitble for indoor application 10 W, 2' length , wall mounted with aluminium housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge |
| 110 | S & F in repair LED 30 Watt bldg secutiry complete with light grade GI brackets, Nuts, bolts, clamps complete with all accessories internaly pre wired and including connecting up with twin core twisted flexible copper conductor cable complete as specified and as directed by Engineer in charge Make - Crompton/ Havells/ Philips/Bajaj/Wipro. |
| 111 | Supply and Fixing storage type electric water heater of 25 Ltrs capacity, 240 volts,rated input 2 KW, PUF insulated fitted with stainless inner container and cooper coil of BEE rating 5 star models, max working head of water 60 Mtrs, fixing to wall with suitable MS tower/anchor bolts,bib cock of suitable size,including cPVC pipe,Inlet/outlet flexible hot water supply pipe, grouted to wall complete all as specified and as directedMake : Venus/BHARAT/PEARL etc. |
| 112 | Supply & Fix tube galvanized medium grade 15 mm dia with all fittings, bends, tees etc concealed in walls including threading and connecting with the existing pipe with a \\"Tee\\" and clamps with botls, nuts etc for fixing and making good the disturbed surfaces complete all as specified and as directed. |
| 113 | Supply & fix PVC metal braided connection pipes for hot water supply with brass adopters 15 mm dia and 450mm long. |
| 114 | Supply and fix stop valves cast coppet alloy 15 mm bore dia screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fized complete all as specified and as directed |
| 115 | S&F bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 116 | M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified & as directed |
| 117 | M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables drawn through and including PVC Casing caping with all accessories complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including suitable size of PVC modular box of suitable module/size, cover plate screws for mounting switches, sockets, regulators etc complete for one light/fan/bell point controlled by one ,one way switches as specified and directed.complete all as specified and as directed by Engineer-in charge. |
| 118 | All as per item No 144.00 here-in-above, but for one exhaust fan point controlled by one switch. |
| 119 | All as per item No 144.00 here-in-above, but for one 3/2 Pin 5 Amp socket out let point on the independent board. |
| 120 | All as per item No 144.00 here-in-above, but for one socket outlet 3/2 pin, 5 Amp, point on the same board with other switches. |
| 121 | All as per item No 144.00 here-in-above, but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket point. |
| 122 | Supply and fix wall mounting fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300 mm complete including connecting with 3 core flexible copper conductor including taking down the existing wall mounted fan and depositing the same in MES store complete all as specified and as directed. |
| 123 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250mm complete including connecting with 3 core flexible copper conductor including taking down the existing exhaust fan and depositing the same in MES store complete all as specified and as directed. |
| 124 | Cutting of brick/stone/sheet for fixing of exhaust fan or passing of chimney duct and making good to the disturbed surface including painting/colour wash as directed by Engr-in-charge. |
| 125 | M&L sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length). |
| 126 | Supply and fix in repair recess mounted low glare LED panellight 2'X2' size 36 watt white/warm white for armstrong/grid ceiling or similar ceiling mounting system complete prewired using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100V grade including taking down old complete all as specified and directed. Make: BAJAJ/Wipro/Crompton/Havells Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender