Educational and Research Institute Boards / Undertakings / PSU Closing in 4 days TDR #57622317

Tender For Augmentation Of Water Supply At Jamia Property Land At Jasola, Jamia Millia Islamia.

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
12.27 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
4 days left
EMD
24555
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Augmentation Of Water Supply At Jamia Property Land At Jasola, Jamia Millia Islamia.

BOQ

Name of Work:- Augmentation of Water Supply at Jamia Property Land at Jasola, Jamia Millia Islamia.
Sl. No. Item Description
1WATER SUPPLY
2Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work
3PN - 16 Pipe, 40 mm OD (SDR-7.4)
4Providing and fixing PPR Unions
5PPR Union 40mm
6Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall
740 mm dia nominal bore
8Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
940 mm nominal bore
10RAIN WATER HARVESTING & TUBEWELLS
11Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
12All types of soil
13300 mm dia
14Rocky strata including Boulders
15300 mm dia
16Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
17300 mm dia
18Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
19Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
20200 mm nominal size dia having minimum wall thickness 5.40 mm
21Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
22200 mm nominal size dia
23Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
24Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
25200 mm dia
26Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
27200 mm clamp
28Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
29200 mm dia
30MARKET RATE ITEMS
31Providing & fixing Galvanized Iron Flange (Pair) with thread including nuts & bolts with rubber packing as per direction of Engineer Incharge.
32Modified Estimated Cost after using correction factor on DSR 2023 on account of GST @ 0.973 * 764449 = 743809
33ELECTRICAL WORK
34WIRING
35Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
36Group A
37Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
382 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
392 X 6 sq. mm + 1 X 6 sq. mm earth wire
40Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
4175 mm X 75 mm X 60 mm deep
42150 mm X 75 mm X 60 mm deep
43180 mm X 100 mm X 60 mm deep
44Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
455/6 amps switch
463 pin 5/6 A socket outlet
47MCCB, MCB & DB'S
48Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required._100 A,30KA,FPMCCB
49Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)_8 way , Double door
50Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required._Single pole
51Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required._63 A
52EARTHING
53Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
54Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
55Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
56Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
57LED LIGHT
58LED Batten light (System lumen efficacy ? 105 <120 lm/Watt). Supplying, Installation, of LED surface mounted Batten light of following body material and construction Operating voltage AC 140- 270 Volt, frequency 50/60 Hz, (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded_18- 22 Watt
59MV CABLE LAYING
60Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required._Above 35 sq. mm and upto 95 sq. mm
61Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required._Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
62MV CABLE JOINTING & END TERMINATION
63Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required._4 X 50 sq. mm (35mm)
64MISC.CIVIL ITEMS
65Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required._63 mm dia (OD-63 mm & ID-51 mm nominal)
66Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required._63 mm dia (OD-63 mm & ID-51 mm nominal)
67Market Rate (M.R.)
68Supply & Fixing 125 amp FP Enclosure ,Havells Make Suitble for Fixing of MCCB 125 Amp FP incomming & outgoing connection of cable Fixing Thimbling Including providing Anchor Dash Fasteners Suitble for Enclosure etc as requried .
69Supply of 7.5 HP 3Phase 17 stage submersible Motor pump 152 /17 maximum head 158 meters 5000 LPH delivery dia 50 mm KSB / Crompton/Kirloskar Make etc. as required at site .
703 core 4 sq mm submersible Flat cable Supply,connecting and lowering in borewell/ surface PVC Insulated Copper conductor submersible Flat cable Finolex/ Polycab/ Plaza make or equalant quality as direction by Engineer In- Charge.
71Supplying, connecting & lowering in borewell of PVC coated GI wire Rope 6 mm dia good quality as approved by Engineer In-charge.
72Supply & Fixing 3 phase MU G10 DOL 13-21 Amp. Starter suitable for Motor, L&T make or equalent as approved by Engineer In-charge.
73Supply of 1.1 KV grade XLPE power Cable of size 4X 50 Sq.mm Aluminium armoured. Havells/Skytone/ RR , Make or Approved Certificate With Test Report By Company Summitted as Engineer Incharge
74Supplying and Fixing LED flood light 100 w cool white BVP175 smart bright slim LED light fitting Philips make or same quality Bajaj/ Havells as per approved by Engineer In-charge.
75Supply and Fixing 6 Sq.mm 2 Core Flat PVC Insulated,Innersheathed, Unarmoured aluminium Cable Plaza /Havells /Polycab Make or Eqiuvalent as approved By Engineer Incharge
76Lifting and Loweeing of 3 phase Submersible Motor Pump (Vertical type ) upto 10 HP etc as required as per direction of Engineer In-charge
77Supplying ,Installation,Testing And Commissioning ELECTRICAL PANEL 7.5 HP DOL STARTER OUTDOOR TYPE FLOOR MOUNTED.PANEL DOUBLE DOOR WITH CANOPY1.6 MM 400X400X200MM.450 MM LEG STAND.MAIN INCOMER 63A 10KA 4P MCB -01SET(L&T/ABB) RYB PHASE INDICATOR - 01SET(L&T) A+V METER DGITAL - 01SET(AP&A) OUTGOING MNX 18A TP Contactor [MAKE : L&T] AUX ADD ON BLOCK [MAKE : L&T] Start, stop Push button [MAKE : L&T] Pump on ,Pump off, Pump Trip indicator [MAKE : L&T] Auto / Manual S. Switch [MAKE :L&T] Control circuit MCB [MAKE : L&T] SPPR [MAKE : ADITYA] out going MCB DP 32 Amp 1 No [MAKE : L&T]out Going MCB SP 6-32 amp 2 No [MAKE : L&T] provision of Neutral link & Earthing studs both sides( Note:- CPRI Approved certificate With Test Report & Approved proper GA Drawing Summitted) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57622317
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 12.27 Lakhs
LAST DATE 26-09-2026
Authority
Authority Name Jamia Millia Islamia
Work Description Tender for Augmentation Of Water Supply At Jamia Property Land At Jasola, Jamia Millia Islamia.
Basic Detail
Tender No JMI/BD/E-NIT/No.23/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 21 Sep 2026
Submission Date 26 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 12.27 Lakhs
Tender Fee 500
EMD 24555
Exemption Not Available
Document List
Agreement.pdf
BOQ_974157.xls
d29cb785-3be6-4c4c-ab19-e35c0349c677.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

Agreement.pdf

xls

BOQ_974157.xls

html

d29cb785-3be6-4c4c-ab19-e35c0349c677.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender