Tender For Augmentation Of Water Supply At Jamia Property Land At Jasola, Jamia Millia Islamia.
Tender Value
12.27 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
4 days left
EMD
24555
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Augmentation Of Water Supply At Jamia Property Land At Jasola, Jamia Millia Islamia.
BOQ
| Sl. No. | Item Description |
| 1 | WATER SUPPLY |
| 2 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work |
| 3 | PN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 4 | Providing and fixing PPR Unions |
| 5 | PPR Union 40mm |
| 6 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall |
| 7 | 40 mm dia nominal bore |
| 8 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 9 | 40 mm nominal bore |
| 10 | RAIN WATER HARVESTING & TUBEWELLS |
| 11 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. |
| 12 | All types of soil |
| 13 | 300 mm dia |
| 14 | Rocky strata including Boulders |
| 15 | 300 mm dia |
| 16 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 17 | 300 mm dia |
| 18 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 19 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. |
| 20 | 200 mm nominal size dia having minimum wall thickness 5.40 mm |
| 21 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. |
| 22 | 200 mm nominal size dia |
| 23 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 24 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: |
| 25 | 200 mm dia |
| 26 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. |
| 27 | 200 mm clamp |
| 28 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). |
| 29 | 200 mm dia |
| 30 | MARKET RATE ITEMS |
| 31 | Providing & fixing Galvanized Iron Flange (Pair) with thread including nuts & bolts with rubber packing as per direction of Engineer Incharge. |
| 32 | Modified Estimated Cost after using correction factor on DSR 2023 on account of GST @ 0.973 * 764449 = 743809 |
| 33 | ELECTRICAL WORK |
| 34 | WIRING |
| 35 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 36 | Group A |
| 37 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 38 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 39 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 40 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 41 | 75 mm X 75 mm X 60 mm deep |
| 42 | 150 mm X 75 mm X 60 mm deep |
| 43 | 180 mm X 100 mm X 60 mm deep |
| 44 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 45 | 5/6 amps switch |
| 46 | 3 pin 5/6 A socket outlet |
| 47 | MCCB, MCB & DB'S |
| 48 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required._100 A,30KA,FPMCCB |
| 49 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)_8 way , Double door |
| 50 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required._Single pole |
| 51 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required._63 A |
| 52 | EARTHING |
| 53 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 54 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 55 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 56 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 57 | LED LIGHT |
| 58 | LED Batten light (System lumen efficacy ? 105 <120 lm/Watt). Supplying, Installation, of LED surface mounted Batten light of following body material and construction Operating voltage AC 140- 270 Volt, frequency 50/60 Hz, (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded_18- 22 Watt |
| 59 | MV CABLE LAYING |
| 60 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required._Above 35 sq. mm and upto 95 sq. mm |
| 61 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required._Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 62 | MV CABLE JOINTING & END TERMINATION |
| 63 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required._4 X 50 sq. mm (35mm) |
| 64 | MISC.CIVIL ITEMS |
| 65 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required._63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 66 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required._63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 67 | Market Rate (M.R.) |
| 68 | Supply & Fixing 125 amp FP Enclosure ,Havells Make Suitble for Fixing of MCCB 125 Amp FP incomming & outgoing connection of cable Fixing Thimbling Including providing Anchor Dash Fasteners Suitble for Enclosure etc as requried . |
| 69 | Supply of 7.5 HP 3Phase 17 stage submersible Motor pump 152 /17 maximum head 158 meters 5000 LPH delivery dia 50 mm KSB / Crompton/Kirloskar Make etc. as required at site . |
| 70 | 3 core 4 sq mm submersible Flat cable Supply,connecting and lowering in borewell/ surface PVC Insulated Copper conductor submersible Flat cable Finolex/ Polycab/ Plaza make or equalant quality as direction by Engineer In- Charge. |
| 71 | Supplying, connecting & lowering in borewell of PVC coated GI wire Rope 6 mm dia good quality as approved by Engineer In-charge. |
| 72 | Supply & Fixing 3 phase MU G10 DOL 13-21 Amp. Starter suitable for Motor, L&T make or equalent as approved by Engineer In-charge. |
| 73 | Supply of 1.1 KV grade XLPE power Cable of size 4X 50 Sq.mm Aluminium armoured. Havells/Skytone/ RR , Make or Approved Certificate With Test Report By Company Summitted as Engineer Incharge |
| 74 | Supplying and Fixing LED flood light 100 w cool white BVP175 smart bright slim LED light fitting Philips make or same quality Bajaj/ Havells as per approved by Engineer In-charge. |
| 75 | Supply and Fixing 6 Sq.mm 2 Core Flat PVC Insulated,Innersheathed, Unarmoured aluminium Cable Plaza /Havells /Polycab Make or Eqiuvalent as approved By Engineer Incharge |
| 76 | Lifting and Loweeing of 3 phase Submersible Motor Pump (Vertical type ) upto 10 HP etc as required as per direction of Engineer In-charge |
| 77 | Supplying ,Installation,Testing And Commissioning ELECTRICAL PANEL 7.5 HP DOL STARTER OUTDOOR TYPE FLOOR MOUNTED.PANEL DOUBLE DOOR WITH CANOPY1.6 MM 400X400X200MM.450 MM LEG STAND.MAIN INCOMER 63A 10KA 4P MCB -01SET(L&T/ABB) RYB PHASE INDICATOR - 01SET(L&T) A+V METER DGITAL - 01SET(AP&A) OUTGOING MNX 18A TP Contactor [MAKE : L&T] AUX ADD ON BLOCK [MAKE : L&T] Start, stop Push button [MAKE : L&T] Pump on ,Pump off, Pump Trip indicator [MAKE : L&T] Auto / Manual S. Switch [MAKE :L&T] Control circuit MCB [MAKE : L&T] SPPR [MAKE : ADITYA] out going MCB DP 32 Amp 1 No [MAKE : L&T]out Going MCB SP 6-32 amp 2 No [MAKE : L&T] provision of Neutral link & Earthing studs both sides( Note:- CPRI Approved certificate With Test Report & Approved proper GA Drawing Summitted) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender