Tender For Installation Of Transformer At Gojri Mohalla Wailoo Under Pri Grants For The Year 2026-27
Tender Value
11.11 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
13 days left
EMD
22220
Bank guarantee accepted
Document Fee
650
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation Of Transformer At Gojri Mohalla Wailoo Under Pri Grants For The Year 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Supply,Carraige upto site, Installation, testing and Commissioning of 11/0.433KV, 63 kVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2 of BIS and with LV Cable Box having detachable Aluminium Gland plate. Transformer should have arrangement for vertical Take off |
| 2 | Supply , Transportation and errection of 9MTR long ST Poles (410 SP-33) completely errected in the pit of 1/6th of the pole length including excavation and back filling of the pole pit. (as per REC Standard) |
| 3 | Supply, Transportation and errection of 8MTR long ST Poles (410-SP 15) completely erected in the pit of 1/5th of the pole length including excavation and back filling of the pole pit . (as per REC standard) |
| 4 | Supply,Carraige upto site,, laying ,stringing, tensioning , binding of ACSR Weasel Conductor, (30mm2 ACSR Conductor) as per REC standard. |
| 5 | Supply,Carraige upto site,, laying and commissioning of, 70 mm² AB (HT) Cable (3 x 70 + 1x95 insulated)mm² XLPE(11 kV, 3C + Earth) |
| 6 | Supply, transportation and fixing of GI Channel /Angle Iron for Cross Arms, Braces, Transformer Belt, F-Top, Collers etc for Sub Station and poles (Complete Job including Nuts & Bolts and Washers) |
| 7 | Supply and fixing of Gapless surge arrestor, 9 KV, 10KA , LA station Type including nuts and bolts, washers, clamps etc. complete job as per REC standard. (Drilling of holes prohibited) |
| 8 | Supply and fixing of 11KV G.O set (AB Switch 3-phase,3 -pole,200A) including nuts and bolts, washers, clamps etc. complete job as per REC standard. (Drilling of holes prohibited) |
| 9 | Supply and fixing of lt Fuse Set. complete job as per REC standard. (Drilling of holes prohibited) |
| 10 | Supply, Carriage up to site, Installation, testing and Commissioning of LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 AmpMCCB 3P 16 kA 1 No.s for Outgoing Circuits |
| 11 | Supply and fixing of 11KV Horn Gap fuse set 3 phase,200A including nuts and bolts, washers, clamps etc. complete job as per REC standard. (Drilling of holes prohibited) |
| 12 | Supply and fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 13 | Supply and fixing of LT Shackle Insulators with G.I Mukhi Clamps (Scaffolding G.I LT Clamps) as per REC standard |
| 14 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 15 | Earthing of Poles Complete by Spike earthing Rod 20mm 2.5mtr long with GI strip 25x3mm (as per REC Standards) |
| 16 | Supply and fixing of 185 mm Sq (2 Ckt) Single Phase 1.1 KV Grade , PVC Insulated stranded conductor FRLS Type including Aluminum Thimbles, PG/SL Clamps etc. as per REC standard |
| 17 | Cement bottoming of S.T poles in 1:2:4 mix 1/6th of the height of pole below the ground and 1ft above the ground cylnerical shape with circular radius 9” from the pole centre) using 40mm crushed stone aggregate mix. As per Drawing 0.48 cum/polePit =( 600x600x1600)& Tappered at the Top. (as per REC standard) for 9 MTR ST Pole |
| 18 | Cement bottoming of S.T poles in 1:2:4 mix 1/6th of the height of pole below the ground and 1ft above the ground cylnerical shape with circular radius 9” from the pole centre) using 40mm crushed stone aggregate mix. As per Drawing 0.40 cum/pole (Pit 600x600x1433.3 mm) for 8 MTR ST Pole |
| 19 | Poviding and Painting of ST Poles with one coat of red oxide and two coats of aluminum paint to give an even shade using anti corrosive paint of standard brand (Nerolac/ Asian) paints) including cost of paint along with stamping on poles showing therein name of the firm date, year of instllaiton and the debitable head etc. |
| 20 | Supply, Carriage up to site, Installation, testing and Commissioning of danger Plates |
| 21 | Supply, Carriage up to site, Installation, testing and Commissioning of anti-climbing devices with clamps |
| 22 | Supply, Carriage up to site, Installation of G.I nuts and bolts etc. |
| 23 | Supply, Carriage up to site, Installation, of PG clamps |
| 24 | Supply, Carriage up to site, Installation, testing and Commissioning of AI Thimbles |
| 25 | Supply, Carriage up to site, Installation, of Sign Board (2X2 feet) (Inscribed with Substation Details provided by this Division) along with required accessories like clamps, nuts and bolts etc. |
| 26 | Supply, Carriage up to site, Installation, testing and Commissioning of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc. |
| 27 | Pre, during and post execution geo tagged photographic evidence consisting of 5x7 inch photographs in coffee table book (covering each pole/Sub Station) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysOct 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender