Tender For Restoration Of Rain Damages Of Water Supply Scheme Khil Bharyara In Tehsil Joginder Nagar Distt Mandi (H.P).(Sh: Construction of Reinforced Cement Concrete Storage Tank With Dome 40000 Ltr Capacity At Vilage Chhattri).
Tender Overview
Project Description
Tender for Restoration Of Rain Damages Of Water Supply Scheme Khil Bharyara In Tehsil Joginder Nagar Distt Mandi (H.P).(Sh: Construction of Reinforced Cement Concrete Storage Tank With Dome 40000 Ltr Capacity At Vilage Chhattri).
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in foundation and trenches in earth work,lifts up to 1.50 meters atacking the excavated soil not more than 3 meters clear from the edge of the excavation and then returning the stacking soil in 15cm .layers, when required in to plinths sides of foundations etc, consolidating each deposted layer by ramming and watering and then deposing of all surplus excavated earth as directed with in a lead of 20 metres in all respect with in all leads and lifts as per the direction of Engineer-in-Charge. |
| 2 | Providing and laying cement concrete 1:3:6(1cement:3sand: 6graded stone aggregate of 40mm nominal size)and curing complete excluding cost of form work including all leads and lifts: a) Foundation and Plinth complete in all respect with in all leads and lifts as per the direction of Engineer in charge. |
| 3 | Providing & laying cement concrete 1:1.5:3 (1 cement 1.5 sand 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of from work and reinforcement of RCC work in foundation with in all leads lifts as per direction and to the entire satisfaction of the Engineer-in-Charge. |
| 4 | In Walls ( any thickness but not less than 0.1 mtr. Thickness) attached pilasters, buttresses, plinth and string courses etc. from top pf foundation level up to floor two level in all leads and lifts. |
| 5 | In foundation footings etc. |
| 6 | Suspended floors, roofs, landings, shelves and their supports balconies, beams girders bressumers and cantilevers upto floor two levels |
| 7 | Providing mild tor steel reinforcement for RCC work including bending, binding and placing in position i/c binding wire complete up to floor two level complete in all respect as per direction & to the entire satisfaction of engineer in charge upto all lead & lifts. |
| 8 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4mtrs.and removal of the same for in situ reinforced concrete and plain concrete work in:- |
| 9 | Vertical surfaces such as Walls ( any thickness but attached pilasters, buttresses, plinth and string courses etc. and the like complete in all leads and lifts. |
| 10 | Arches Dome |
| 11 | Providing and fixing of 3.15 mm MS sheet manhole cover 600 x 600 mm fixed with all sides with ISA 40x25x5 mm top angle frame hinged on ISA 35x35x5 mm bottom angle iron frame as per drawing , pieces of MS flat 20x4 mm, 0.15 m long to be fixed on all sides on hold fast , angle section & welding of MS sheet angle section , hinges , handles 150 mm long 20x4 mm flat , locking arrangement and applying a priming coat of stell prime after pretreatment of surface to the entire satisfaction of Engineer in charge. |
| 12 | Providing and fixing of ladder inner and outer side of square pipe of size 40 x 40 mmx 2 mm and 30 x 30 x2 mm , including cost of cutting welding carriage, labour and applying a priming coat of red lead complete as per the direction and satisfaction of Engineer in charge. |
| 13 | Providing and fixing CI flanged sluice valve as per IS 14846/2000 of nominal pressure and (PN 1.0) with cap, rubber gasket complete as per the direction and satisfaction of Engineer in charge. ( Kartar make) |
| 14 | 80 mm dia |
| 15 | 1.20metre high fencing (as per approved design) 1.80 metres RCC posts 3 metres centre to centre and RCC struts with nine horizontal lines and two diagonals of galvanised steel barbed wire (IS:278-1962 type-I) weighing 9.38kg/100metre (minimum) strained and fixed to posts by typing to 6mm galvanised steel bar niles/clips with G.I. binding wire including cost of excavation RCC struts and straining bolts and embedded in cement concrete 1:4:8 ( 1 cement : 4 sand : 8 graded stone aggregate 40 mm nominal size ) and curing complete in all respect and entire satisfaction of Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender