Public Administrative Department Local Bodies Closing in 8 days TDR #57620208

Tender For Repairing And Maintenance Of Fire Fighting System, Fire Alarm System And Fire Check Doors Of Aav East Kidwai Nagar, East Kidwai Nagar Barat Ghar And East Kidwai Nagar Market.

Issued by Local Bodies · New Delhi, Delhi
Tender Value
31.23 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
8 days left
EMD
62477
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairing And Maintenance Of Fire Fighting System, Fire Alarm System And Fire Check Doors Of Aav East Kidwai Nagar, East Kidwai Nagar Barat Ghar And East Kidwai Nagar Market.

BOQ

Name of Work:- Repairing and maintenance of fire fighting system, Fire Alarm system and Fire Check doors of AAV East Kidwai nagar, East Kidwai nagar barat ghar and East Kidwai nagar market.
Sl. No. Item Description
1Steel Work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat cost of approved steel primer using structural steel etc. as reqd.In stringers, treads, landing etc of stair cases, including use of chequered plate wherever required, all complete as specified
2Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion
4Powder coated aluminium (minimum thickness of powder coating 50 micron)
5For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
6Powder coated aluminium (minimum thickness of powder coating 50 micron)
7Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
8With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
9Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.
10Powder coated minimum thickness 50 micron aluminium tubular handle bar
11Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
12(a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class 'F' insulation, conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads
13900 lpm at 35 m Head
14Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including cutting, screwing Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets, chilly clamps, including cutting holes and chases in bricks/core cutting in RCC wall/slab etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame including, dismantling of MS Pipe providing coat of steel primer and painting with two or more coats of synthetic enamel paint of approved required shade etc. complete to the entire satisfaction of Fire Officer. The measurement of pipe upto the level finish MS Pipe in the elbow.
15100 mm dia.
16150 mm dia
17Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required Single headed Stainless steel
18Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
19100 mm dia.
20Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required.
21100 mm dia.
22Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.a) 30 M
23Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
24Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required
25Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
26Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
2710 Zone
28Supplying & laying of 2 x 1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required.
29Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
30P/F/T/C of Motor Control panel of cubical construction floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust & vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with solid aluminium strip/single core PVC insulated FRLS copper conducted cable, having suitable mounting for switch hear & accessories & internal control (relay, timer, sensor annunciation window for fault indication ON/OFF/TRIP indication along with suitable conductors, overload protection, current sensing type single phase preventer & colour coded power wiring with suitable size fire retardant low smoke PVC insulated copper cable with conductor, earth terminals, numbering suitable for operation on 415V, 3 phase, 50 HZ AC supply with enclosure protection class IP 42 complete as per satisfaction. Starter meter, selector switches, indicating LED with terminal facilities for repeat indicator of various audio & visual at terrace level & remote push button for ON/OFF operation in Fire Control Room etc. complete to the entire direction and satisfaction of Enginner in-Charge / Fire Officer. Suitable for Terrace pump - 02 Sets
31Supply and fixing of 2 hour fire rated Steel Fire Door Frame 100x57mm single rebated as per site and location complete with directions of Engineer-in-charge/ Fire Officer.a) The door frame shall be 2 hours 3 criteria rating (Stability, Integrity and thermal Insulation) fire door- fabricated and complying with requirements of CBRI Roorkee/Government Department and conforming to relevant BS: 476 Part 20 & 22 & IS: 3614 Part II.b) The frame shall be fabricated from 1.6 mm thick galvanized steel sheet conforming to IS:277 with a factory pre-punhced groove so as to accomodate Fire & smoke seal size 10 x 4mm Frames should be butt jointed and field assembeled with bolting sytem for proper strength. Frames shall be provided with holdfasts, fasteners etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.Note: The frame shoule be finished with Powder coating in desired shade.
32Providing and Fixing 46 mm thick Steel fire check door shutter of 120 minutes fire rating for stability & Integrity & 20 minutes of insulation confirming to BS:476 Part 22 and IS: 3614 Part II fabricated with 2 nos. 1.2 mm thick galvanized sheet with infill of fire rated Mineral Wool insulation filler of 64 Kg./M3 bonded to both faces of sheet with lock seam joints at stile edges and internal reinforcement at top, bottam and stile edges for fire rating. The door frames are manufactured from 1.6mm thick galvanized steel sheet pressed form to single Rebate profile of size 100mm 57mm. The door frames and door shutters are finished with \\"H\\" primer plus powder coating etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.Note: The shutter shoule be finished with Powder coating in desired shade.
33Supply and fixing of 6mm thick, 2 Hrs. Fire Rated clear glass which can also withstand thermal shock upto 800 degree centigrade shall be used as in vision panel and is to be fixed in between the glass beading by using ceramic fiber and fire rated acrylic sealant in accordance with BS : 476 Part 22, EN 1363/EN 1364 for stability and integrity etc complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
34Providing and fixing of 2 hour fire rated Door Closers UL tested for fire doors, fire tested in accordance of EN 1634-3 and for mechanical test to EN 1154 for 50000 cycles and shall be tested with fire door for 2 Hours fire rating door weight upto 36 kg, to 80 Kg and door width from 701mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
35Supplying and Fixing of Stainless Steel Tower Bolt of 300 x 10 mm 2 hrs Fire rated on existing double leaf door shutters openable inside or outside etc. complete U.L. listed, CBRI tested complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
36Providing and fixing stainless steel 304 Grade D - Type pull handle 2 hrs fire rated of size 300 mm long and 22 mm Dia including stainless, Caps, nuts and bolts etc. of required size complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
37Providing and Fixing of 2hrs fire rated Mortice dead Lock of superior quality complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
38Supply & application of 2 hour fire rated Fire Sealant in Joints between frame & wall and Filling upto 25mm in width as per manufacturer’s specification with backup rod, paper taping on both the faces to avoid spoiling of adjacent walls, as required and as per direction of Engineer-In-Charge.(Note : Above 25 mm in width, the measurement will consider 25 mm in width)
39Supplying and laying of following size XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 as required with proper termination complete in all respect to the entire satisfaction Fire Officer.
403 x 70 Sq. mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57620208
AUTHORITY Local Bodies
TENDER VALUE 31.23 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name New Delhi Municipal Council
Work Description Tender for Repairing And Maintenance Of Fire Fighting System, Fire Alarm System And Fire Check Doors Of Aav East Kidwai Nagar, East Kidwai Nagar Barat Ghar And East Kidwai Nagar Market.
Basic Detail
Tender No 12/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 21 Sep 2026
Submission Date 30 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 31.23 Lakhs
Tender Fee Ref. Documents
EMD 62477
Exemption Not Available
Document List
84bb9232-a354-4283-99c5-6b585a8e2074.html
BOQ_398473.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

84bb9232-a354-4283-99c5-6b585a8e2074.html

xls

BOQ_398473.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders