Defence Statutory Bodies & Commissions/Committees Closing in 22 days TDR #57619876

Tender For Provn Of 315 Kva Transformer And Connected Works For Otm Accn Under Ge Jhansi

Issued by Statutory Bodies & Commissions/Committees · Jhansi, Uttar Pradesh
Tender Value
31 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
22 days left
EMD
62000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jhansi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 315 Kva Transformer And Connected Works For Otm Accn Under Ge Jhansi

BOQ

Name of Work:- PROVN OF 315 KVA TRANSFORMER AND CONNECTED WORKS FOR OTM ACCN UNDER GE JHANSI
Sl. No. Item Description
1Supply and erection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 mtr long) including painting of poles with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and black bituminous paint on embedded portion and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band/ strips (Make : 3M or equivalent ) of 5 cm wide in Green (02 Nos ) & White (01 No) colour shall be provided at a height of 1.25 mtr from coping of pole and writing the pole number in black colour on yellow background at a suitable place on the pole complete all as specified and directed.Note :- Excavation and concrete shall be measured and paid separately under relevant items of this BOQ.
2M&L for lighting arrestors expulsion type with all fitting distribution class, discharge capacity 65 kilo Amps, current rating 5 KA suitable for 11000 volts complete connecting with ACSR jumpers from LA to air brake switch with PVC sleeves complete all as specified and directed.
3Supplying, Installing, Connecting and testing of 11 KV 200 Amps triple pole gang operated air break switch having 12 Nos post insulator with earthing switch rotating type for horizontal/ vertical operation mechanically operated 3 rows type mounted on insulator (including insulators) and steel frame with operating mechanism consisting of operating rod of 25mm bore medium grade GI pipe of suitable length to operated from ground level including locking arrangement with pad lock of godrej make with three Nos of keys including 11 KV swing out explusion fuses (drop out type) of 10 Amps complete all as specified and directed.
4Supply and fix of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
5M&L for danger notice plate of 1.6 mm thick mild steel sheet , vitreous enamelled white,with latters,figurs and conventional skull bones in single red colour and fixed with M.S. clamps.bolts and nuts of approved size, for HT,25x20 cm size embeded in PCC 1:3:6 using 20 mm stone aggregate complete all as specified and directed.
6M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
7Supply, installation, testing and commissioning of step down transformer out door type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11KV 3 Phase and LT 433 volts 3 phase 4 wire , Dyn-11, copper wound, with off load tap changer having voltage variation of ±7.5% in step of 2.5 % continuous rating of capacity 315 KVA with temperature rise shall not exceed 45° C for transformer winding and 40° C for top oil complete conforming to IS 1180 (Part 1) : 2014 Energy Efficiency Level - 3 for transformer including necessary suitable sIze PCC plateform and comrrising of following fittings :-(a) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing.(b) Lifting lugs/hooks . (c) Rating and terminal marking plate.(d) Silica gel breather .(e) Drain - cum - sampling valve (3/4)\\" nominal thread with plug (f)Thermometer pocket with dial type thermometer.(g) Oil filling inlet pipe with plug.(h) Conservator with oil level gauge.(j) First fill of oil up to appropriate level as recommended by manufacturer with fresh new oil. (k) Type of connection arrangement : MS cable termination box on LT side and open bushing on HT side.NOTE :- Plinth stone masonry platform as per manufacturer recommendations complete with standard fittings conforming to IS-1180 energy efficient and with ECBC Closset or latest IS complete all as specified and as directed. (Note:-Stone masonary platform will be measured and paid separately)
8Supply, laying, testing & commissioning of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheath, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 95 sqmm, 3 core, 11000 volts grade(Earthed) cable confirming to IS 7098 (Part-II) complete all as specified and directed.Note :- Excavation, earthwork, sand Cushioning, Cable covers, pipe for cable protection to be measured and paid separately.
9Supply design, Fabricate, Installation, Testing & Commissioning in replacement of outdoor type dust proof & vermin proof cubical panel board compartmentalized with separate bus bar and cable alley chambers suitable for 3 phase, 4 wire, 415 volts, 50 Hz, Ac supply system as per latest IS/IEC standards & regulations, factory fabricated in an approved factory (manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3.15mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mm x 50mm x 6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards (02Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall be suitable for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity complete all as specified and directed :-
10Note : (i) Factory made name plates with feeder names/ Bldg Nos shall be fixed on relevant incomer/outgoing MCCB doors.(ii) The contractor shall submit set of all drawings of the LT Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing.However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
11(i) Bus bar : TPN Aluminium bus bar of suitable rating provided with heat shrinkable coloured PVC sleeves insulation mounted on insulators for main bus bar and from main bus bar to outgoing MCCB's and outgoing MCCB's up to cable termination etc complete. (The rating of main bus bar shall be 1.5 times of ampere rating of incomer and outgoing bus bar rating shall be 1.5 times of ampere rating of each outgoing MCCB.) and continuous earth bus with GI strip of suitable size capable for carrying full short circuit current for 1 sec shall be provided at bottom of the panel.(ii) Incomer :(a) MCCB 200 Amps, 4 Pole, 36 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release - 01 No(b) Digital Voltmeter with selector switch - 01 Set(c) Digital Ammeter with selector switch & suitable ratio of CT's - 01 Set of 3(d) LED Pilot light indication lamps R,Y,B phases - 01 Set of 3(iii) Outgoing :-(e) MCCB 200 Amps, 4 Pole, 36 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release -1 Nos(f) MCCB 100 Amps, 16 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release -2 Nos (g) MCB TPN 63 Amps, 16 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release -2 Nos
12Supply design, Fabricate, Installation, Testing & Commissioning in replacement of outdoor type dust proof & vermin proof cubical panel board compartmentalized with separate bus bar and cable alley chambers suitable for 3 phase, 4 wire, 415 volts, 50 Hz, Ac supply system as per latest IS/IEC standards & regulations, factory fabricated in an approved factory (manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3.15mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mm x 50mm x 6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards (02Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall be suitable for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity complete all as specified and directed :-
13Note : (i) Factory made name plates with feeder names/ Bldg Nos shall be fixed on relevant incomer/outgoing MCCB doors.(ii) The contractor shall submit set of all drawings of the LT Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing.However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
14(i) Bus bar : TPN Aluminium bus bar of suitable rating provided with heat shrinkable coloured PVC sleeves insulation mounted on insulators for main bus bar and from main bus bar to outgoing MCCB's and outgoing MCCB's up to cable termination etc complete. (The rating of main bus bar shall be 1.5 times of ampere rating of incomer and outgoing bus bar rating shall be 1.5 times of ampere rating of each outgoing MCCB.) and continuous earth bus with GI strip of suitable size capable for carrying full short circuit current for 1 sec shall be provided at bottom of the panel.(ii) Incomer :(a) MCCB 500 Amps, 4 Pole, 36 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release - 01 No(b) Digital Voltmeter with selector switch - 01 Set(c) Digital Ammeter with selector switch & suitable ratio of CT's - 01 Set of 3(d) LED Pilot light indication lamps R,Y,B phases - 01 Set of 3(iii) Outgoing :-(e) MCCB 200 Amps, 4 Pole, 36 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release -2 Nos(f) MCCB 100 Amps, 16 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release -2 Nos (g) MCB TPN 63 Amps, 16 KA (Ics=100%Icu), 415 Volts, 50 Hz, with adjustable thermal and fixed magnetic release -2 Nos
15Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 500 Sqmm, 3.5 Core complete all as specified and directed.
16Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 240 Sqmm, 3.5 Core complete all as specified and directed.
17Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 25 Sqmm, 4 Core complete all as specified and directed.
18Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 16 Sqmm, 4 Core complete all as specified and directed.
19Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
20M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth strip protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
21M&L for earthing complete with Copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 20x3 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth Strip protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
22Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in Hard/ Dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed.
23Supply and spread river sand in trenches for cushioning of cable / in the yard of outdoor substations complete all as specified and directed. (Note: Punned down thickness only shall be measured for the purpose of payment)
24Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
25Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
26Supplying and laying in replacement of un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm for cable protection in trenches complete all as specified and directed.
27Supplying and laying in replacement of un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed.
28M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines / cables and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
29Supply and fixing of 100mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed.
30M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of pole/ stay assembly complete all as specified and directed by Engineer-in-Charge.
31Material and labour for PCC 1:2:4 Type B1 (20mm graded stone aggregate) including necessary form work for DG set foundation complete all as specified and directed.
32Supply and spread graded coarse stone aggregate of 40 mm nominal size around outdoor transformer and HT 11 KV two/four pole structure complete all as specified and directed.
33Excavation in post holes (or similar holes) each not exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete in any type of soil.
34M&L for mild steel work as in replacement of posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets(for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
35Supply and fix in replacement of Galvanized Steel Chain Link fencing of mesh size 50mm x 50mm and dia of wire 4.00mm with and including line wires fixed to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed by Engineer-in-Charge.
36M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc conforming to Fe.290.Gde-E-165 complete all as specified and directed.
37M&L for Brickwork with sub class ‘B’ bricks on plan built in CM 1:6 complete all as specified and directed.
38M&L for rendering 15 mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57619876
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 31 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 315 Kva Transformer And Connected Works For Otm Accn Under Ge Jhansi
Basic Detail
Tender No CWE/JHA/J/TOKEN/64 OF 2026-27
Bidding Type Tender
Location
City Jhansi
State Uttar Pradesh
Key Dates
Publish Date 21 Sep 2026
Submission Date 14 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 31 Lakhs
Tender Fee 500
EMD 62000
Exemption Available
Document List
92f6c3a4-e5f2-4542-b12e-08ca8e689362.html
BOQ_885950.xls
TD64.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

92f6c3a4-e5f2-4542-b12e-08ca8e689362.html

xls

BOQ_885950.xls

pdf

TD64.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender