Tender For Maintenance And Improvement Of 33 Kv/11 Kv/0.433 Kv Electric Supply Installations Including Attending Of Day To Day External Complaints At Zone-Ii Under Ge(A) Jaisalmer
Tender Value
65 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
27 days left
EMD
1.23 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance And Improvement Of 33 Kv/11 Kv/0.433 Kv Electric Supply Installations Including Attending Of Day To Day External Complaints At Zone-Ii Under Ge(A) Jaisalmer
BOQ
| Sl. No. | Item Description |
| 1 | M&L for fault finding & rectification in 33 KV system such as earth faults,blownoff DO fuses,jumpers,Loose Connection rectification, Identifying sparking at overhead jumpers,flash at substation busbars with mandatory ON/OFF switching, and earthing protocols for all Vacuum Circuit Breakers (VCB) and Ring Main Units (RMU) for the 33 KV High Tension (HT) overhead power supply from 132 KV Substation to 33 KV Substation near StnHQ under GE(A) Jaisalmer immediately upon receipt of a complaint from JE,AGE or GE by identifying the fault complete with necessary safety tools and tackling by providing one skilled electrician and one helper for attending the complaints at any time inlcuding sundays and holidays with all safety gears(including 33 KV dielectric gloves,discharge/earth rods, meggers and insulation ladders) and complete power restoration and submit the complaint rectification slip or requires real time communication back to the JE/AGE/GE with submission of complaint rectification slip duly signed by respective user rep.Note:-(i) The rate against the above mentioned item is deemed for cost of labour,transportation,tools ,safety equipments folding ladder,insulation tapesand DO fuses and other misc consumables items for repair work.(ii) Tradsmen deployed can communicate with non smart mobile for the easy acess with user &JE E/M during complaints/breakdowns |
| 2 | (iii) The contractor's representative will report to concerned JE E/M to collect the list of breakdowns and will submit the completion report to the JE E/M.(iv) Before commencement of any complaint the contractor's rep shall take prior permission for shutdown from JE/AGE/GE. In case the breakdown is not rectified within the specified time limit i.e 2 hr an amount of Rs 500/- per hr shall be recovered from the contarctor during RAR / Final Bill or due to to major breakdown which requires spares/items,contractor rep must be inform to concern JE/AGE within an hr after receipt of complaint. (v)Register of complaints should be prepared by the contractor's rep and details of repair be updated in the register after completion of every work duly signed by user and JE E/M. (vi) Register of repair should be prepared by the contractor and details of repair to be updated in the register after completion of every work duly signed by user rank not lessthan NCO. |
| 3 | M&L for fault finding & rectification in 11 KV system such as earth faults,blownoff DO fuses,jumpers,Loose Connection rectification, Identifying sparking at overhead jumpers,flash at substation busbars with mandatory ON/OFF switching, and earthing protocols for all Vacuum Circuit Breakers (VCB) and Ring Main Units (RMU) for the 11 KV High Tension (HT) overhead power supply of Zone-II under GE(A) Jaisalmer immediately upon receipt of a complaint from JE,AGE or GE by identifying the fault complete with necessary safety tools and tackling by providing one electrician and helper for attending the complaints at any time inlcuding sundays and holidays with all safety gears(including 11 KV dielectric gloves,discharge/earth rods, meggers and insulation ladders) and complete power restoration and submit the complaint rectification slip or requires real time communication back to the JE/AGE/GE with submission of complaint rectification slip duly signed by respective user rep.Note:-(i) The rate against the above mentioned item is deemed for cost of labour,transportation,tools ,safety equipments folding ladder,insulation tapes and other misc consumables items for repair work.(ii) Tradesman deployed can communicate with non smart mobile for the easy acess with user &JE E/M during complaints/breakdowns |
| 4 | (iii) The contractor's representative will report to concerned JE E/M to collect the list of breakdowns and will submit the completion report to the JE E/M.(vi) Before commencement of any attending complaint the contractor shall ask prior permission for shutdown from JE/AGE/GE. In case the breakdown is not made functional within the specified time limit i.e 2 hrs an amount of Rs 500/- per hr shall be recovered from the contarctor during RAR / Final Bill. (v)Register of repair should be prepared by the contractor and details of repair to be updated in the register after completion of every work duly signed by user and JE E/M for payment purpose(vi) Register of repair should be prepared by the contractor and details of repair to be updated in the register after completion of every work duly signed by user rank not lessthan NCO. |
| 5 | Material and labour for attending external electrification 0.433 KV breakdowns/complaint in LT panel/busbar by one skilled electrician and one helper at any time including sundays and holidays having sound in knowledge of 0.433 KV overehead and under grounds LT netwrok system and breakdown complaints supply shall be attended so as to rectify the faluted system and complete restoration all as specified and directed by Engr-In-Charge.During breakdown supply, the technician shall coordinate/laison with substation operator/JE/AGE for replacement of parts and services as required.Note:-(i) The rate against the above mentioned item is deemed for cost of labour,transportation,tools such as clamp meter,plier,tester,test lamp,screw driver,hacksaw,hammer,spanner and other tools reqired to attend complaints and safety equipments folding ladder,insulation tapes misc items like insulation tape for repair work.(ii) Contractor shall provide one experienced electrician and one helper per shift to attend the complaints round the clock and during emergency complaints.(iii) Quoated rate is deemed to be inclusive of tools mentioned in ser no 01 failing may effect penal recovery of Rs 500/- will be made once in entire contract period. |
| 6 | (iv) Items required such as cable,joints and other switch gear,lugs etc will be measured and paid separarely.Quoated rate is inclusive of removing of cable loop from the attended area towards completion of electrical defect.(v) The LT break down complaint shall be shall be attendwithin 1 hrs after receipt of complaint frpm any mode/agency.(vi) The contractor's representative will report to concerned JE E/M to collect the list of breakdowns and will submit the completion report to the JE E/M.(vii) Before commencement of any attending complaint the contractor's staff shall get prior permission for shutdown from JE/AGE/GE. In case the breakdown has not been restored within the specified time limit, an amount of Rs 500/- per hr will be recovered from the contarctor during RAR / Final Bill. (viii)Register of breakdown/no light complaints should be prepared by the technician and details of repair to be updated in the register after completion of every work duly signed by user or JE E/M. |
| 7 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HTpolymer insulators (9 insulators type & 6 insulators for DO with horizontal operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 33000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). Note: Apply petroleum jelly on contact portion deemed to be included |
| 8 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT polymer insulators (9 insulators type & 6 insulators for DO with horizontal operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). Note: Apply petroleum jelly on contact portion deemed to be included |
| 9 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT polymer insulators (9 insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately).Note: Apply petroleum jelly on contact portion deemed to be included |
| 10 | M&L in replacement of cable Jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed by Engineer-in-Charge. Make: Raychem RPG/3M |
| 11 | M&L in replacement of cable Jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed by Engineer-in-Charge Make: Raychem RPG/3M |
| 12 | Supply, Jointing and testing in replacement of out door type cable termination heat shrinkable joint kit suitable for size 95 Sq mm 3 core 11KV (Earthed cable) under ground XLPE cable and including taking down old unsv joint complete all as directed by Engr-in-Charge. Make: Raychem RPG/3M |
| 13 | --- ditto --- all as per item No 9 above but size of 185 Sqmm 3 Core. Make: Raychem RPG/3M |
| 14 | Supply, Jointing and testing in replacement of in door type cable termination heat shrinkable joint kit suitable for 95 Sq mm 3 core 11 KV (Earthed cable) under ground XLPE cable all as directed by Engr-in-Charge. Make: Raychem RPG/3M |
| 15 | --- ditto --- all as per item No 11 above but size of 185 Sqmm 3 Core . Make: Raychem RPG/3M |
| 16 | Supply jointing and testing in replacement of straight through heat shrinkable joint kit suitable for 95 Sq mm 3 core 11 KV (Earthed cable) under ground XLPE cable complete and including taking down old unsv joint complete all as directed by Engr-in-Charge. Make: Raychem RPG/3M |
| 17 | --- ditto --- all as per item No 13 above but size of 185 Sqmm 3 Core .Make: Raychem RPG/3M |
| 18 | S&F in repair fuse wire suitable for Horn gap fuse units at 2/4 pole structures of following capacity/size :- |
| 19 | (d) 40 Amp |
| 20 | (e) 50 Amp |
| 21 | (f) 60 Amp |
| 22 | Supply, laying & testing in replacement of XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 95 sqmm, 3 core as per IS:7098 PART-2 incl taking down unsv cable complete.all as specified and as directed by Engr -in- Charge. |
| 23 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 24 | Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 25 | Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers all as specified & directed at site. |
| 26 | Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge. |
| 27 | Supply, laying in repair and Jointing 150 mm X 130 mm outer dia and inner dia , HDPE double walled corrugated (DWC) pipe conforming to IS-16205 with antirodent and non flame propogating properties of approved colour including necessay fittings like bend, tee, elbow,socket etc. for cable protection complete all as specified and as directed.Note :- Joints are designed to be watertight and moisture proof. |
| 28 | Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F in repair GI pipe light grade of dia 150 mm laying in road and along with poles for cable protection complete and including taking down old unsv pipe of 80mm dia complete all as directed by Engr-in-Charge. |
| 30 | M & L in repair cement concrete (1:3:6) type C-1 using 20mm grade stone aggregate for foundation of stay assembly struts or pole etc complete all as directed including taking out old broken pcc from site or deposited as directed by Engr-In-Charge. |
| 31 | M & L in repair cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate for coping around poles including necessary form work finishing even and smoth with out using extra cement complete all as directed including taking out old broken pcc from site or deposited as directed by Engr-In-Charge. |
| 32 | M & L for cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of PCC pole/struts as specified including necessary form work finishing even and smoth with out using extra cement complete all as directed. |
| 33 | Material and labour for substation yard spreading levelling with 40 mm graded coarse aggregate / gravells laid approximately 75 mm thick layers near VCB/Transformer /2/4 pole structure and plateform etc all as directed. |
| 34 | Material and labour for substation yard spreading levelling with 20 mm graded coarse aggregate / gravells laid approximately 75 mm thick layers near VCB/Transformer /2/4 pole structure and plateform etc all as directed. |
| 35 | M&L for Cuttting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 1.5 meters from the over head line to nearby trees complete all as specified. Note :- Only effected span of over head conductor shall be measured as span. |
| 36 | M &L in replacement of steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 mtrs long) including painting with two coats of aluminium paint over a coat of red oxide metal primer complete all as specified and directed by Engr-in-Charge. The pole shall conform to IS 2713:1980 and each component pipe shall be ISI marked and conform to IS 1161 and including taking down old unsv PCC/RCC pole complete all as specified and directed by Engr-in Charge.Note: Necessary hydra/crane/JCB to carryout the work is deemeed to be incluisve. |
| 37 | M &L in replacement of steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 mtrs long) including painting with two coats of aluminium paint over a coat of red oxide metal primer complete including taking down old unsv PCC/RCC pole complete all as specified and directed by Engr-in-Charge. Note: Necessary hydra/crane/JCB to carryout the work is deemeed to be incluisve. |
| 38 | M&L for finding cable fault with electronic fault detector in LT/HT UG cable of any size complete including earthwork and refill earth work after cable joint complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fixing in replacement of feeder Piller Box outdoor type double door front openable in two half not less than 1.20mx1.20mx1.00m made out of 3.15 mm thick CRCA sheet podwer coated paint in heat process of sheet, supported on angle iron frame 50x50x6mm having legs 1.2,mtr long grouted in PCC upto 60cm, aluminium bus bar 03 Nos rated capacity 200A (HT) duly insulated 11000 Volt grade for phases supported on HT porcelain insulator and having danger notice plate with skull symbol PCC foundation 1:2:4 completed all as specified and as directed by Engr in Charge.Note:Quoated rate is inclusive of provn of al drop locking arrangement on both front and back side |
| 40 | M & L in replacement of bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, Coal & salt up to ground level connected to 32X6 mm GI strip as earthing lead up to 7.5 mtr length of earth strip rates deemed to be included in quoated rate and by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40 mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle,provision of watering arrangement with funnel and wire mess etc and testing on complete all as specified and directed by Engr-in-charge. |
| 41 | M & L in replacement for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones of Post Office RED Colour and fixed on HT Poles with M.S. clamps, bolts and nuts of required size, for 11000 Volts HT of size 250 X 200 mm complete including taking down existing one complete all as directed. |
| 42 | M&L in repair for copper jumpers with 8 mm solid copper wire of 1.8mtr length each bend to shape and set of 3 Nos including RYB heat shrinkable copper sleeves and copper PG Clamps/bimettalic copper/aluminium PG clamps copper nut,bolts & washers completed all as directed.Note: Set of 3 jumpers of 1.8 mtr and connected hardware each shall be measured as one set |
| 43 | Same as per item no 38 above but size of 0.5 mtr length of copper solid wire |
| 44 | Supply and fixing in repair 3 core PVC insulated and unsheathed 1100 volt grade multicore cable 1.5 sqmm with stranded copper conductor cable including PVC pipe 20mm dia with necessary fittings on pole from looping box to security light fitting complete all as specified and directed by Engr-in- Charge. |
| 45 | Supply and Fix in repair Weather proof Street light Junction Box of size 230 x 170X105 mm depth including MCB SP 6 Amp C Curve and connecting terminals 4-way and fixing with street light poles (steel) using necessary MS Clamps, nuts, bolts washers of suitable size duly painted etc.complete all as specified and directed. |
| 46 | Supply and fixing in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver with separate surge protection device 5ka rating , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and sepatate connector block for termination of incomming cable connection and including taking down old UNSV street light completeall as specified and directed by Engr -in- Charge. |
| 47 | M&L in replacement for MS work as in railing, guard bars, grill conforming to Fe-290 Gde E 165 complete all as specified and as diredcted by Engineer-in-Charge. |
| 48 | M&L in replacement for Expanded metal, n.exc 4 Kg / Sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified.complete all as specified and as diredcted by Engineer-in-Charge. |
| 49 | S&F in replacement of Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, 11 to 15 mm dia complete all as specified and as diredcted by Engineer-in-Charge. |
| 50 | M&L for two coat of synthetic enamel paint over a coat of primer including preparation on existing MS/ steel surfaces of any description over 10 cm width or girth complete all as specified and as directed by Engineer-in-Charge. |
| 51 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft /disintegrated rock. Please Enable Macros to View BoQ information |
| 52 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft /disintegrated rock. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysOct 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender