Tender For Special Repairs To Electrical Installation, Fans, Water Heater And Split Type Ac Unit Arrangements To The Inspection Bungalow In Vilamal At Thiruvarur In Thiruvarur District.
Tender Value
3.80 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
13 days left
EMD
3900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvarur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Electrical Installation, Fans, Water Heater And Split Type Ac Unit Arrangements To The Inspection Bungalow In Vilamal At Thiruvarur In Thiruvarur District.
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring with 2 x 1.5sq.mm PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylem sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (for electronic regulator) (5 points per coil) |
| 2 | Renewal by supply and fixing of 4feet LED 20W fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting. |
| 3 | Renewal by supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher End) with 600mm down rod on the existing fan clamp. |
| 4 | Renewal by supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. |
| 5 | Renewal by supply and fixing of 3Nos 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection. (for computer plug socket) |
| 6 | Renewal by supply and run of 2 of 2.5sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5sq.mm copper wire with painting of suitable colour. |
| 7 | Renewal by supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting . |
| 8 | Renewal by supply and fixing of 1500W automatic electric water heater of 35 litres capacity suitable for 230V, 50c/s, AC supply on suitable MS clamps with 3 core flex wire but without plumbing connection. |
| 9 | Renewal by supply and fixing of 1 x 4 40W LED fitting with LED tube complete with TW round blocks on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 10 | Renewal by supply and installation of 2.0TR (60000 K.cal/Hr) ABS Plastic Split type Air Conditioner conforming to with rotary compressor operating on refrigerant non CFC suitable for wall mounting for operation on 230V, 50Hz, single phase AC supply as per BEE specification and capable of performing the functions of Cooling, Dehumidifying, Air Circulating, Filtering. The installation works for the above split type AC units includes the following: 1. Mounting / Fitting Indoor and outdoor units at their respective locations. 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole / holes in the wall if required. 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. 5. Leakage testing the entire system unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units upto 6 Mtrs length and upto switch within 3 Meters of location of indoor unit. |
| 11 | Renewal by supply and fixing of angle Iron frame work to rest the outdoor unit. |
| 12 | Renewal by supply and fixing of water drain pipe. |
| 13 | Renewal by supply and laying of 5/8\\" and 3/8\\" copper pipe (Extra beyond 3 Metres supplied with AC unit) |
| 14 | Renewal by supply and laying of 3½ x 50sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75metre putting 0.15metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. |
| 15 | Renewal by supply and frxing of brass cable gland for 3½ x 50sq.mm PVC armoured LTUG cable with earth connection. |
| 16 | Renewal by supply and providing cable end termination of 3½ x 50sq.mm PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. |
| 17 | Sub Total |
| 18 | Add GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysOct 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender