Bids Are invited for Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 01 Of Tender Document , Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 02 Of Tender Document , Operation And M
Tender Overview
Project Description
Bids Are invited for Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 01 Of Tender Document , Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 02 Of Tender Document , Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 03 Of Tender Document , Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 04 Of Tender Document , Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 05 Of Tender Document , Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 06 Of Tender Document , Operation And Maintenance Of Electro-Mechanical Installations - As Per Boq Item No 07 Of Tender Document - Operation And Upkeeping Of E & M Installations Of 33 Kv Sub-Station Of New Terminal Building As Per Special Conditions Of Contract. The Contractor Has To Deploy Following Minimum Manpower On Each Day In Shift Duty Including Sundays & Holidays But Excluding Weekly Off :-A) Highly Skilled (Supervisor) - 2 No.B) Skilled - 7 Nos.C) Semi-Skilled - 7 No.C) Unskilled - 14 No. , Visiting Charges By Highly Skilled Personnel Having Experience Of Control Wiring, Well Versed With Control Wiring Drawing For Identification & Rectification Of Fault In Amf Panel Of Dg Sets / Syncronization Panel , Interlocking Mechanism Of Ht/Lt Ckt. Breakers, Relays, Apfc Panels / Transformer Faults Or Any Kind Of Fault In E&M Installations At 33 Kv Substation As Required. , Dehydration And Filtration Of Transformer Oil Of 2000 Kva Transformer (Name Plate Rated Oil Qty.-2900 Liters.) I/C Submission Of Before & After Break Down Value Reports Of Transformer Oil Including Replacement Of Silica Gel Etc. Complete As Required. , Supply & Topping Up Of Transformer Oil If Required After Oil Filtration For 2000 Kva Transformer Etc. As Required. , Servicing And Testing Of 800 A - 4000 A Ratings, 3/4 Pole Microprocessor Release, Edo/ Mdo Type Lt Acbs (Make : Siemens) Annually As Per Oem Recommendation (Defective Spare Part If Any Will Be Provided By Aai), Submission Of Test/ Service Reports Etc. Complete As Required. , Servicing And Testing Of 33 Kv, 1250 A Vcb Ht Circuit Breaker (Make : Abb) Annually As Per Oems Recommendations . Submission Of Test/Service Reports (Defective Spare Part If Any Will Be Provided By Aai), Submission Of Test/ Service Reports Etc. Complete As Required. , Testing Of All Relays Of 33 Kv Ht Panel (2 I/C + 5 O/G) Annually As Per Oems Recommendations And Attending Break Downs (Defective Spare Part Will Be Provided By Aai), Servicing And Testing Of 33 Kv, 1250 A Vcb Ht Circuit Breaker (Make : Abb) Annually As Per Oems Recommendations . Submission Of Test/Service Reports (Defective Spare Part If Any Will Be Provided By Aai), Submission Of Test/ Service Reports Etc. Complete As Required.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Operation and Upkeeping of E & M installations of 33 kV sub-station of New Terminal Building as per Special Conditions of Contract. The contractor has to deploy following minimum manpower on each day in shift duty including sundays & holidays but excluding weekly off :-a) Highly Skilled (Supervisor) - 2 No.b) Skilled - 7 Nos.c) Semi-Skilled - 7 No.c) Unskilled - 14 No. | Operation and Upkeeping of E & M installations of 33 kV sub-station of New Terminal Building as per Special Conditions of Contract. The contractor has to deploy following minimum manpower on each day in shift duty including sundays & holidays but excluding weekly off :-a) Highly Skilled (Supervisor) - 2 No.b) Skilled - 7 Nos.c) Semi-Skilled - 7 No.c) Unskilled - 14 No. |
| 2 | Visiting charges by highly skilled personnel having experience of control wiring, well versed with control wiring drawing for identification & rectification of fault in AMF Panel of DG sets / Syncronization Panel , interlocking mechanism of HT/LT Ckt. Breakers, relays, APFC Panels / transformer faults or any kind of fault in E&M installations at 33 kV substation as required. | Visiting charges by highly skilled personnel having experience of control wiring, well versed with control wiring drawing for identification & rectification of fault in AMF Panel of DG sets / Syncronization Panel , interlocking mechanism of HT/LT Ckt. Breakers, relays, APFC Panels / transformer faults or any kind of fault in E&M installations at 33 kV substation as required. |
| 3 | Dehydration and filtration of transformer oil of 2000 KVA transformer (Name plate rated Oil Qty.-2900 liters.) i/c submission of before & after break down value reports of transformer oil including replacement of silica gel etc. complete as required. | Dehydration and filtration of transformer oil of 2000 KVA transformer (Name plate rated Oil Qty.-2900 liters.) i/c submission of before & after break down value reports of transformer oil including replacement of silica gel etc. complete as required. |
| 4 | Supply & topping up of Transformer oil if required after oil filtration for 2000 KVA Transformer etc. as required. | Supply & topping up of Transformer oil if required after oil filtration for 2000 KVA Transformer etc. as required. |
| 5 | Servicing and testing of 800 A - 4000 A ratings, 3/4 pole microprocessor release, EDO/ MDO type LT ACBs (Make : Siemens) annually as per OEM recommendation (defective spare part if any will be provided by AAI), submission of test/ service reports etc. complete as required. | Servicing and testing of 800 A - 4000 A ratings, 3/4 pole microprocessor release, EDO/ MDO type LT ACBs (Make : Siemens) annually as per OEM recommendation (defective spare part if any will be provided by AAI), submission of test/ service reports etc. complete as required. |
| 6 | Servicing and testing of 33 kV, 1250 A VCB HT circuit breaker (Make : ABB) annually as per OEM's recommendations . Submission of test/service reports (defective spare part if any will be provided by AAI), submission of test/ service reports etc. complete as required. | Servicing and testing of 33 kV, 1250 A VCB HT circuit breaker (Make : ABB) annually as per OEM's recommendations . Submission of test/service reports (defective spare part if any will be provided by AAI), submission of test/ service reports etc. complete as required. |
| 7 | Testing of all relays of 33 kV HT Panel (2 I/C + 5 O/G) annually as per OEM's recommendations and attending break downs (defective spare part will be provided by AAI), Servicing and testing of 33 kV, 1250 A VCB HT circuit breaker (Make : ABB) annually as per OEM's recommendations . Submission of test/service reports (defective spare part if any will be provided by AAI), submission of test/ service reports etc. complete as required. | Testing of all relays of 33 kV HT Panel (2 I/C + 5 O/G) annually as per OEM's recommendations and attending break downs (defective spare part will be provided by AAI), Servicing and testing of 33 kV, 1250 A VCB HT circuit breaker (Make : ABB) annually as per OEM's recommendations . Submission of test/service reports (defective spare part if any will be provided by AAI), submission of test/ service reports etc. complete as required. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender