Tender For Construction Of Compound Wall At Vechicle Parking Approach Road For Arulmigu Bhavani Amman Temple, Periyapalayam, Uthukottai Taluk, Thiruvallur District.
Tender Value
14.73 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
4 days left
EMD
15000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of Compound Wall At Vechicle Parking Approach Road For Arulmigu Bhavani Amman Temple, Periyapalayam, Uthukottai Taluk, Thiruvallur District.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | Supplying and filling in foundation, basement, etc with filling Msand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 3 | Cement concrete 1:5:10 (One part of cement five part of M-sand and ten part of HBG jelly) for foundation using 40mm gauge HBG jelly inclusive of shoring strutting and baling out water where ever necessary ramming curing etc.,complete as per Std, Specification and as directed by the Dept, Officers |
| 4 | Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). For Pile Concrete |
| 5 | Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 6 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 0cm centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 7 | Supplying and erecting steel centering including necessary supports for plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5mm and supported by Steel Adjustable Telescopic Props of size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) etc,. complete in all floors complying with standard specifcation. Steel Adjustable props shall be provided as directed by the departmental Officers.(Payment for centering shall be given after the concrete is laid) |
| 8 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 9 | Brick work in following Cement Mortar 1:5( one part of cement five part of msand ) using best quality bricks of size 9\\" x 4-3/8\\" x 2- 3/4\\" Clay with class designation of 7.5 for foundation and basement including Cost of Mortar Plasticizer,curing, etc., complete complying with standard specifiction. Foundation & Basement. |
| 10 | Brick partition walls of 11.50cm thickness using best quality bricks of size 9\\" x 4-3/8\\" x 2-3/4\\" Clay with class designation of 7.5 in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer,curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) Ground Floor. |
| 11 | Plastering the surface of walls with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 12 | Painting two coats of newly plastered wall surface with ready mixed exterior plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 13 | Supply and fixing Mild steel grill of windows,appro ventilators etc., complete complying with standard specifications and as directed by the departmental officers. |
| 14 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer beforeuse on works.) |
| 15 | Labour charges for Drilling / Boring towards provide under reamed cast in situ pile to a depth of 0m to 4.50m depth from the Existing Ground level with single bulb including cost of machinary, labour charges and other materials required etc..complete complying with the standard specification and as directed by the departmental officers. ( Concrete and Steel reinforcement shall be measured and paid seperately ) |
| 16 | 250 mm dia Pile |
| 17 | 450 mm dia Pile |
| 18 | Sub Total |
| 19 | GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender