BOQ
| Sl. No. | Item Description |
| 1 | Renewal and rewiring with 2 x 1.5sq.mm PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylem sheet of 3mm thick with painting of suitable colour for open PVC light / fan point. (for electronic regulator) (5 points per coil) |
| 2 | Renewal by supply and fixing of 4feet LED 20W fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting. |
| 3 | Renewal by supply and fixing of 1200mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter downrod on the existing clamp. |
| 4 | Renewal by supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb. |
| 5 | Supply and fixing of WT bulk head fitting with guard suitable with 20W LED bulb. |
| 6 | Renewal by supply and fixing of 48W LED street light fitting with LED (Higher End) with 32mm dia. GI pipe (Class 'B') with 1No 32mm dia. GI bend complete on the existing post / on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting. |
| 7 | Renewal by supply and fixing of AC / DC 76mm buzzer / call bell suitable for 230V, 50c/s, Single phase AC supply on suitable TW board with push switch. |
| 8 | Renewal by supply and fixing of 1000W automatic electric water heater of 25 litres capacity suitable for 230V, 50c/s AC supply on suitable MS clamps with 3 core flex wire but without plumbing work. |
| 9 | Renewal by supply and fixing of 3Nos 6A two module 3 pin socket , 3Nos 6A one module switch on suitable module surface mounting box (plastic) with module cover plate (plastic) on wall with connections. (Higher End) |
| 10 | Renewal by supply and run of 2 of 2.5sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5sq.mm copper wire with painting of suitable colour. |
| 11 | Renewal by supply and fixing of 1No 6/16A two module socket, 1No 16A one module switch on suitable module surface mounting box (plastic) with module cover plate (plastic) on wall with connections. (Higher End) |
| 12 | Renewal by supply and fixing of 20A Flush type wall socket 32A DP MCB complete set for AC plug in flush with wall with earth connection. (For AC plug) |
| 13 | Renewal by supply and run of 2 of 4sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4sq.mm copper wire with painting of suitable colour. |
| 14 | Renewal by supply, erection, testing, commissioning uninterrupted power supply (sinewave) with copper wound transformer of 1.125 KVA with input supply of 230V, 50Hz, AC supply with 150AH Tubular battery to work at full load capacity including transportation with following specification. 1.Input voltage: 230, 50Hz single phase AC supply.2.Output voltage: 220V to 240V, 50Hz AC supply.3.Battery charging device of suitable rating4.Circuit board of suitable capacity.5.Over load and short circuit protection.6.Visual Indication for ON/OFF/Trip/battery charging/mains failure/low battery etc.,7. Mode setting for By pass / Reset8.12V, 150AH battery - 1No. 9. Trolley or MS stand for UPS & battery. |
| 15 | Renewal by supply and Installation of 1.5 TR (4500 K.cal/Hr) ABS Plastic Split type Air conditioner with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating as per BEE specification and capable of performing the functions of Cooling, Dehumidifying, Air Circulating, Filtering The installation works for the above split type AC units includes the following. 1 .Mounting / Fitting Indoor and outdoor units at their respective locations. 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required. 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. 5. Leakage testing the entire system unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit. |
| 16 | Renewal by supply and installation of 4KVA Electronic Automatic Voltage Stabilizer with Input Voltage range of 170V – 270V and Output Voltage range 200V to 240V with High and Low Voltage cutoff and 3 minutes time delay relay with demonstration. |
| 17 | Renewal by supply and fixing of angle Iron frame work to rest the outdoor unit. |
| 18 | Renewal by supply and fixing of water drain pipe. |
| 19 | Renewal by supply and laying of 5/8\\" and 3/8\\" copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 20 | Renewl by supply and fixing of TNEB meterboard suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and interconnection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1No 40A 30MA Double Pole RCD / RCCB (Higher End) with suitable necessary connection. |
| 21 | Renewal by supply and run of 2 of 6sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7/20 GI bearer wirefor service connection mains. |
| 22 | Renewal by supply and run of 2 of 6sq.mmPVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 6sq.mm copper wire with painting of suitable colour. |
| 23 | Renewal by supply and run of 2 of 6sq.mm (84/0.3)PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 25mm dia. GI pipe (Class 'B') bent at both ends with necessary angle iron up right and end supports for mains. |
| 24 | Renewal by supply and run of 2 of 4sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7/20 GI bearer wire for service connection mains. |
| 25 | Renewal by supply and run of 2 of 4sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4sq.mm copper wire with painting of suitable colour. |
| 26 | Renewal by supply and run of 2 of 4sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 25mm dia. GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains. |
| 27 | Renewal by supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1No 32A DP MCB as incoming and 6Nos 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. (Higher End) |
| 28 | Renewal by Earthing as per PWD standard with an earth electrode of 2metre Class 'B' GI pipe of dia. not less than 32mm complete with necessary masonry work. |
| 29 | Renewal by supply and run of 1 of No. 8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. |
| 30 | Sub Total |
| 31 | Add GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysOct 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender