Tender for Construction Of Proposed Dr. B.R. Ambedkar State Institute Of Medical Sciences At Sector-81, Mohali., Punjab (Girls & Boys Hostel)
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKExcavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. Mechanical Means |
| 2 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 3 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 4 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 5 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. |
| 6 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 7 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 8 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 9 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 10 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. 1st Floor |
| 11 | 2nd Floor |
| 12 | 3rd Floor |
| 13 | 4th Floor |
| 14 | 5th Floor |
| 15 | 6th Floor |
| 16 | 7th Floor |
| 17 | Terrace |
| 18 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 19 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering infoundation and plinth. |
| 20 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 21 | Reinforced cement cocrete M-30 mechanicaly batch mixed using batch type mixer and without needle vibrator mixed but excluding steel reinforcement, centering and shuttering in Foundation & Plinth structure. |
| 22 | Reinforced cement concrete M-40 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 23 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 24 | Reinforced cement cocrete M-40 mechnicaly batch mixed using batch type concrete mixer asper IS:1791 and vibrator by needle vibrator but excluding steel reinforcement, centering and shuttering in super structure. |
| 25 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 26 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) |
| 27 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) Foundation |
| 28 | Gr. Floor |
| 29 | 1st Floor |
| 30 | 2nd Floor |
| 31 | 3rd Floor |
| 32 | 4th Floor |
| 33 | 5th Floor |
| 34 | 6th Floor |
| 35 | 7th Floor |
| 36 | Terrace |
| 37 | Cement concrete 1:5:10 with brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 38 | Boring, providing and installing bored cast-insitu reinforced cement concrete pile of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of concrete and steel reinforcement (The rates of concrete and steel reinforcement are to be taken for respective item of chapter No.10 & 18 respectively) but including the cost of boring with manual auger (without bentonite solution) and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete as per BIS specifications/ codes, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap) 600 mm Dia pile |
| 39 | Extra for using Bentonite slury with Bentonite pump in case of unstable bore. 600 mm Dia pile |
| 40 | Vertical load testing of piles in accordance with IS 2911 (Part-IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer incharge. Group of two or more piles upto 50 tonne. Routine test. |
| 41 | Cyclic vertical load testing of pile in accordance with IS code of practice IS : 2911 (part-IV) including preparation of pile head etc for. Group of two or more piles upto 50 tonne. Upto 50 tonne capacity pile |
| 42 | Lateral load testing of single pile in accordance with IS code of practice IS : 2911 (part-IV) for determining safe allowable lateral load on pile. Above 50 tonne and upto 100 tonne capacity pile |
| 43 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 44 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 45 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 46 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. 1st Floor |
| 47 | 2nd Floor |
| 48 | 3rd Floor |
| 49 | 4th Floor |
| 50 | 5th Floor |
| 51 | 6th Floor |
| 52 | 7th Floor |
| 53 | Terrace |
| 54 | Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. 1st Floor |
| 55 | 2nd Floor |
| 56 | 3rd Floor |
| 57 | 4th Floor |
| 58 | 5th Floor |
| 59 | 6th Floor |
| 60 | 7th Floor |
| 61 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. |
| 62 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3} in super structure above plinth level up to floor V level in cement mortar 1 :4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 63 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 64 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer. |
| 65 | Providing and fixing tiled false ceiling at height upto 4 Mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 66 | Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning I self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self- centering arrangement that freely rotates/ moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap |
| 67 | Providing and fixing of expansion joint system related with wall joint(internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning I centering arrangement and support plates as per ASTM 8221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to comer application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap |
| 68 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering arrangement that freely rotates/ moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). Roof Joint of 100 mm gap |
| 69 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 70 | Kota stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
| 71 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 72 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 73 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. Slabs sizes above 0.50 sqm |
| 74 | Providing and fixing 18mm to 20mm thick marbel strips in joints of terrazo/cement concrete floors. 50mm wide |
| 75 | Providing and laying Mat finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in- Charge : Mat finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 76 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 77 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge |
| 78 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 79 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 80 | Extra For flooring for every additional storey 1st Floor |
| 81 | 2nd Floor |
| 82 | 3rd Floor |
| 83 | 4th Floor |
| 84 | 5th Floor |
| 85 | 6th Floor |
| 86 | 7th Floor |
| 87 | Terrace |
| 88 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 89 | 12.5 mm thick cement plaster 1:5 |
| 90 | 20mm thick cement mortar bend/ drip course in cement mortar 1:4 |
| 91 | Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect. |
| 92 | Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level. 1st Floor |
| 93 | 2nd Floor |
| 94 | 3rd Floor |
| 95 | 4th Floor |
| 96 | 5th Floor |
| 97 | 6th Floor |
| 98 | 7th Floor |
| 99 | Terrace |
| 100 | Extra for plastering exterior walls of height more than Third storey from ground level for every additional height of single storey or part thereof. 1st Floor |
| 101 | 2nd Floor |
| 102 | 3rd Floor |
| 103 | 4th Floor |
| 104 | 5th Floor |
| 105 | 6th Floor |
| 106 | 7th Floor |
| 107 | Terrace |
| 108 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 109 | Finishing walls with Acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 110 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 111 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 112 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 113 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 114 | Extra rates for External white washing, distempering, painting and decorative cement based paints etc for walls of height above Third storey from ground level for every additional height of single storey or part thereof 3rd Floor |
| 115 | 4th Floor |
| 116 | 5th Floor |
| 117 | 6th Floor |
| 118 | 7th Floor |
| 119 | Terrace |
| 120 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 121 | Factory manufactured solid flush door fixed in position iron hinges, etc excluding the cost of any fittings other than specified above but including labour for fixing the same in position Code : IS-2202-1 (1999) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 122 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 123 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 124 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 125 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 126 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 127 | Providing and Fixing Single Glazing with 6mm thick glass with high Perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge. |
| 128 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 129 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 130 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 131 | Steel Fe-415, Fe-500, Fe-550 (ISI Marked).(Ex Shop in local Market) Extra rate for Steel Fe-415, Fe-500, Fe-550 (Integrated Plant Marked). |
| 132 | Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted onspecially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) |
| 133 | Providing and fixing ball bearing for push and pull type rolling shutters, from 9.20 to 12 sqm area |
| 134 | Supplying and fixing door frames (Chowkat) consisting of frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per IS:513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones (as per approved colour), 3nos 100mm butt-hinges 2mm thick, 6Nos 1.2mm thick CRCA electroplated stiffner, 6nos M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished wiyh powder coated total thickness of coating 0.60mm of approved shade, fixed in position, including the cost of cement concrete for1:2:4 for fixing lugs complete in all respects as per drawing,design, specification & entire stasfication of Engineer-in-Charge18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter. |
| 135 | Supply & fixing of window frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position by means of PVC & metal hold fastner with PVC cap complete in all respect as per drawing, design, specification & entire stasfication of Engineer-in-Charge. Windows Outer frame of size 72mmx55mm and central mullion 72mm x 50mm with Double rebate |
| 136 | Supply & fixing of window shutter consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position fixed by means of screws complete in all respect as per drawing, design, specification & entire stasfication of Engineer-in-Charge. Glazed Windows shutter Section 47mm x 20mm (without glass) |
| 137 | Wire Mesh Windows shutter Section 40mm x 20mm with S.S wir mesh 32 guage flymesh with 144 holes per square inch |
| 138 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . |
| 139 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately). |
| 140 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.l. beading made out of 1.6 mm thick G.l. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.l. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 11 00x2200 mm (w x h) or 2.42 sqm. |
| 141 | Providing and fixing non load bearing fixed frame for fire resistant glazed partition for 120 minutes fire rating, made out to a profile of dimension 60 mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 minutes of both integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M 10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear measurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density minimum 96kg/ cum and finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per NBC2016, IS 16231 (Part 3):2016 and directions of Engineer- in- Charge. |
| 142 | Providing and fixing factory made ISI marked partially insulated metal fire rated doorset assembly, for staircase / exit pathway and refuge areas applications, consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 PI classification of IS 3614:2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested as per IS 17518 (Part -1): 2022 Frame:The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS 4351. The smoke seal material shall be of EPDM or any other material tested in accordane with BS 476 (Part-22) ASTM E-84 of minimum size 10 x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK headed fastner of minimum 8 mm dia size and minimum 80mm long hot dip galvanized with 8mm dia Polyamide sleeves 5 number at each on vertical sides and 3 number on top side.Door shutter:The double skinned double leaf partially insulated door shutters shall be consisting of minimum 50 mm thickness and having box like structure, slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resin bonded mineral wool/ceremic wool infill material of minimum density 96 kg/cum. Each door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaves. Integral astragals to be provided for double leaf door on the meeting style each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing hinges as per EN 1935: 2002 or butt hinges as per IS 12817, of minimum size 100x75x3 mm 5 numbers hinges upto 2400mm height or as per test evidence, whichever is more. fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. |
| 143 | Accessories Hardware:Fire doorset assembly shall be provided with one number of single point panic push bar (cross bar) for active leaf and one number double point panic push bar (cross bar) of desired finish with verticle shoot bolts on top and bottom for inacitvie leaf of double leaf door as per EN 1125, one number external trim with half cylinder 42 mm long with one side key as per EN 1125, two number heavy duty door closers of size 3-5 with standard arm with of desired finish (suitable for 1250 mm wide door leaf) conforming to IS 3564/EN 1154, and one number surface mounted door coordinator with integral shock absorber.Finishing:Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS: 13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge.Installation: The hollow space in the door frame shall be filled with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete door assembly, supply and installation by the approved manufacturer.Double leaf partially Insulated metal fire rated doorset of FD 120 PI classification with 120 minutes integrity and 30 minutes insulation as per IS 3614:2021 for Staircase/ Exit pathway / Refuge area etc |
| 144 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material frommarket to workshop & workshop to site of work. |
| 145 | Re-barring ( Chemical Anchor) of 8mm dia bar, hole size 12mm, depth 100mm with 10ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) re-baring chemical complete in all respect. |
| 146 | Re-barring ( Chemical Anchor) of 10mm dia bar, hole size 14mm, depth 100mm with 10 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) re-baring chemical complete in all respect. |
| 147 | Re-barring (Chemical Anchor) of 12mm dia bar, hole size 16mm, depth 120mm with 14 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 148 | Re-barring (Chemical Anchor) per hole for 16mm dia bar, hole size 20mm, depth 160mm with injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical 24 ML |
| 149 | Re-barring (Chemical Anchor) of 20mm dia bar, hole size 25mm, depth 200mm with 47 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 150 | Re-barring (Chemical anchor) of 25mm dia bar, hole size 32mm, depth 250mm with 100 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 151 | BOYS HOSTEL BUILDING CIVIL WORK |
| 152 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. Mechanical Means |
| 153 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 154 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 155 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 156 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. |
| 157 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 158 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 159 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 160 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 161 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. 1st Floor |
| 162 | 2nd Floor |
| 163 | 3rd Floor |
| 164 | 4th Floor |
| 165 | 5th Floor |
| 166 | Terrace |
| 167 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 168 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering infoundation and plinth. |
| 169 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 170 | Reinforced cement cocrete M-30 mechanicaly batch mixed using batch type mixer and without needle vibrator mixed but excluding steel reinforcement, centering and shuttering in Foundation & Plinth structure. |
| 171 | Reinforced cement concrete M-35 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 172 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 173 | Reinforced cement concrete M-35 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 174 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 175 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) |
| 176 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) Foundation |
| 177 | Gr. Floor |
| 178 | 1st Floor |
| 179 | 2nd Floor |
| 180 | 3rd Floor |
| 181 | 4th Floor |
| 182 | 5th Floor |
| 183 | Terrace |
| 184 | Cement concrete 1:5:10 with brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 185 | Boring, providing and installing bored cast-insitu reinforced cement concrete pile of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of concrete and steel reinforcement (The rates of concrete and steel reinforcement are to be taken for respective item of chapter No.10 & 18 respectively) but including the cost of boring with manual auger (without bentonite solution) and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete as per BIS specifications/ codes, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap) 600 mm Dia pile |
| 186 | Extra for using Bentonite slury with Bentonite pump in case of unstable bore. 600 mm Dia pile |
| 187 | Vertical load testing of piles in accordance with IS 2911 (Part-IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer incharge. Group of two or more piles upto 50 tonne. Routine test. |
| 188 | Cyclic vertical load testing of pile in accordance with IS code of practice IS : 2911 (part-IV) including preparation of pile head etc for. Group of two or more piles upto 50 tonne. Upto 50 tonne capacity pile |
| 189 | Lateral load testing of single pile in accordance with IS code of practice IS : 2911 (part-IV) for determining safe allowable lateral load on pile. Above 50 tonne and upto 100 tonne capacity pile |
| 190 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 191 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 192 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 193 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. 1st Floor |
| 194 | 2nd Floor |
| 195 | 3rd Floor |
| 196 | 4th Floor |
| 197 | 5th Floor |
| 198 | Terrace |
| 199 | Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. 1st Floor |
| 200 | 2nd Floor |
| 201 | 3rd Floor |
| 202 | 4th Floor |
| 203 | 5th Floor |
| 204 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. |
| 205 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3} in super structure above plinth level up to floor V level in cement mortar 1 :4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 206 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 207 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer. |
| 208 | Providing and fixing tiled false ceiling at height upto 4 Mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 209 | Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning I self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self- centering arrangement that freely rotates/ moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap |
| 210 | Providing and fixing of expansion joint system related with wall joint(internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning I centering arrangement and support plates as per ASTM 8221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to comer application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap |
| 211 | Providing and fixing of expansion joint system of approved make andmanufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering arrangement thatfreely rotates/ moves in all directions. The Self centering arrangementshall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). Roof Joint of 100 mm gap |
| 212 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 213 | Kota stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
| 214 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 215 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 216 | Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. Slabs sizes above 0.50 sqm |
| 217 | Providing and fixing 18mm to 20mm thick marbel strips in joints of terrazo/cement concrete floors. 50mm wide |
| 218 | Providing and laying Mat finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in- Charge : Mat finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 219 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 220 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge |
| 221 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 222 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 223 | Extra For flooring for every additional storey 1st Floor |
| 224 | 2nd Floor |
| 225 | 3rd Floor |
| 226 | 4th Floor |
| 227 | 5th Floor |
| 228 | Terrace |
| 229 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 230 | 12.5 mm thick cement plaster 1:5 |
| 231 | 20mm thick cement mortar bend/ drip course in cement mortar 1:4 |
| 232 | Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect. |
| 233 | Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level. 1st Floor |
| 234 | 2nd Floor |
| 235 | 3rd Floor |
| 236 | 4th Floor |
| 237 | 5th Floor |
| 238 | Terrace |
| 239 | Extra for plastering exterior walls of height more than Third storey from ground level for every additional height of single storey or part thereof. 1st Floor |
| 240 | 2nd Floor |
| 241 | 3rd Floor |
| 242 | 4th Floor |
| 243 | 5th Floor |
| 244 | Terrace |
| 245 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 246 | walls with Acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 247 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 248 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 249 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 250 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 251 | Extra rates for External white washing, distempering, painting and decorative cement based paints etc for walls of height above Third storey from ground level for every additional height of single storey or part thereof 3rd Floor |
| 252 | 4th Floor |
| 253 | 5th Floor |
| 254 | Terrace |
| 255 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 256 | Factory manufactured solid flush door fixed in position iron hinges, etc excluding the cost of any fittings other than specified above but including labour for fixing the same in position Code : IS-2202-1 (1999) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 257 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 258 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 259 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 260 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 261 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 262 | Providing and Fixing Single Glazing with 6mm thick glass with high Perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge. |
| 263 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 264 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 265 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 266 | Steel Fe-415, Fe-500, Fe-550 (ISI Marked).(Ex Shop in local Market) Extra rate for Steel Fe-415, Fe-500, Fe-550 (Integrated Plant Marked). |
| 267 | Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted onspecially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) |
| 268 | Providing and fixing ball bearing for push and pull type rolling shutters, from 9.20 to 12 sqm area |
| 269 | Supplying and fixing door frames (Chowkat) consisting of frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per IS:513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones (as per approved colour), 3nos 100mm butt-hinges 2mm thick, 6Nos 1.2mm thick CRCA electroplated stiffner, 6nos M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished wiyh powder coated total thickness of coating 0.60mm of approved shade, fixed in position, including the cost of cement concrete for1:2:4 for fixing lugs complete in all respects as per drawing,design, specification & entire stasfication of Engineer-in-Charge18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter. |
| 270 | Supply & fixing of window frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position by means of PVC & metal hold fastner with PVC cap complete in all respect as per drawing, design, specification & entire stasfication of Engineer-in-Charge. Windows Outer frame of size 72mmx55mm and central mullion 72mm x 50mm with Double rebate |
| 271 | Supply & fixing of window shutter consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position fixed by means of screws complete in all respect as per drawing, design, specification & entire stasfication of Engineer-in-Charge. Glazed Windows shutter Section 47mm x 20mm (without glass) |
| 272 | Wire Mesh Windows shutter Section 40mm x 20mm with S.S wir mesh 32 guage flymesh with 144 holes per square inch |
| 273 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . |
| 274 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately). |
| 275 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.l. beading made out of 1.6 mm thick G.l. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.l. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 11 00x2200 mm (w x h) or 2.42 sqm. |
| 276 | Providing and fixing non load bearing fixed frame for fire resistant glazed partition for 120 minutes fire rating, made out to a profile of dimension 60 mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 minutes of both integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M 10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear measurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density minimum 96kg/ cum and finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016 and directions of Engineer- in- Charge. |
| 277 | Providing and fixing factory made ISI marked partially insulated metal fire rated doorset assembly, for staircase / exit pathway and refuge areas applications, consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 PI classification of IS 3614:2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested as per IS 17518 (Part -1): 2022 Frame:The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS 4351. The smoke seal material shall be of EPDM or any other material tested in accordane with BS 476 (Part-22) ASTM E-84 of minimum size 10 x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK headed fastner of minimum 8 mm dia size and minimum 80mm long hot dip galvanized with 8mm dia Polyamide sleeves 5 number at each on vertical sides and 3 number on top side.Door shutter:The double skinned double leaf partially insulated door shutters shall be consisting of minimum 50 mm thickness and having box like structure, slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resin bonded mineral wool/ceremic wool infill material of minimum density 96 kg/cum. Each door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaves. Integral astragals to be provided for double leaf door on the meeting style each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing hinges as per EN 1935: 2002 or butt hinges as per IS 12817, of minimum size 100x75x3 mm 5 numbers hinges upto 2400mm height or as per test evidence, whichever is more. fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories.Accessories Hardware:Fire doorset assembly shall be provided with one number of single point panic push bar (cross bar) for active leaf and one number double point panic push bar (cross bar) of desired finish with verticle shoot bolts on top and bottom for inacitvie leaf of double leaf door as per EN 1125, one number external trim with half cylinder 42 mm long with one side key as per EN 1125, two number heavy duty door closers of size 3-5 with standard arm with of desired finish (suitable for 1250 mm wide door leaf) conforming to IS 3564/EN 1154, and one number surface mounted door coordinator with integral shock absorber.Finishing:Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS: 13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge.Installation: The hollow space in the door frame shall be filled with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete door assembly, supply and installation by the approved manufacturer.Double leaf partially Insulated metal fire rated doorset of FD 120 PI classification with 120 minutes integrity and 30 minutes insulation as per IS 3614:2021 for Staircase/ Exit pathway / Refuge area etc |
| 278 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material frommarket to workshop & workshop to site of work. |
| 279 | Re-barring ( Chemical Anchor) of 8mm dia bar, hole size 12mm, depth 100mm with 10ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) re-baring chemical complete in all respect. |
| 280 | Re-barring ( Chemical Anchor) of 10mm dia bar, hole size 14mm, depth 100mm with 10 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) re-baring chemical complete in all respect. |
| 281 | Re-barring (Chemical Anchor) of 12mm dia bar, hole size 16mm, depth 120mm with 14 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 282 | Re-barring (Chemical Anchor) per hole for 16mm dia bar, hole size 20mm, depth 160mm with injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical 24 ML |
| 283 | Re-barring (Chemical Anchor) of 20mm dia bar, hole size 25mm, depth 200mm with 47 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 284 | Re-barring (Chemical anchor) of 25mm dia bar, hole size 32mm, depth 250mm with 100 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect. |
| 285 | SUB STATION BUILDING CIVIL WORK |
| 286 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 287 | Earth filling under floors with surplus soil containing more than 40% gravel or kankar excavated from foundation & taken only from outside the building plinth in 15 cm layers including ramming watering and consolidation lead upto 30 metres |
| 288 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 289 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 290 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 291 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 292 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 293 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforment centering and shuttering in foundation & plinth |
| 294 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforment centering and shuttering in superstructure |
| 295 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) |
| 296 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 297 | Cement concrete 1:5:10 with stone ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 298 | First class burnt stone laid in cement sand mortar 1:6 in foundation and plinth |
| 299 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 300 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 301 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer. |
| 302 | Cement Concrete 1:2:4 with stone ballast or single using concrete using concrete mixer volumetric type 20 mm guage. |
| 303 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 304 | Kota stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
| 305 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 306 | 12.5 mm thick cement plaster 1:5 |
| 307 | 20mm thick cement plaster 1:6 in two coats work |
| 308 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 309 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 310 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 311 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 312 | Applying priming coat with metal primer on new steel or iron work including preparation of surface.. |
| 313 | Providing and Fixing Single Glazing with 6mm thick glass with high Perfromance coating as per relevent codal provisions as per satisfaction of Engineer-in-Charge. |
| 314 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 315 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 30mm thick |
| 316 | Providing and fixing aluminum sliding door bolts ISI marked nodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mmx16mm |
| 317 | Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) |
| 318 | Providing and fixing ball bearing for push and pull type rolling shutters, from 9.20 to 12 sqm area |
| 319 | Extra for providing mechanical device, chain and crank operation, for operating rolling shutter, exceeding 11.20 sqm in area, of the rolling shutter |
| 320 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 321 | Steel Fe-415, Fe-500, Fe-550 (ISI Marked).(Ex Shop in local Market) Extra rate for Steel Fe-415, Fe-500, Fe-550 (Integrated Plant Marked). |
| 322 | Supplying and fixing door frames (Chowkat) consisting of frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per IS:513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones (as per approved colour), 3nos 100mm butt-hinges 2mm thick, 6Nos 1.2mm thick CRCA electroplated stiffner, 6nos M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished wiyh powder coated total thickness of coating 0.60mm of approved shade, fixed in position, .including the cost of cement concrete for1:2:4 for fixing lugs complete in all respects as per drawing,design, specification & entire stasfication of Engineer-in-Charge18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge Door frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter. |
| 323 | Supply & fixing of window frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position by means of PVC & metal hold fastner with PVC cap complete in all respect as per drawing, design, specification & entire stasfication of Engineer-in-Charge Windows Outer frame of size 72mmx55mm and central mullion 72mm x 50mm with Double rebate |
| 324 | Supply & fixing of window shutter consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position fixed by means of screws complete in all respect as per drawing, design, specification & entire stasfication of Engineer-in-Charge Glazed Windows shutter Section 47mm x 20mm (without glass) |
| 325 | Wire Mesh Windows shutter Section 40mm x 20mm with S.S wir mesh 32 guage flymesh with 144 holes per square inch |
| 326 | Providing and fixing wire mesh G.I. chain link 10 gauge mesh size 50 mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respect as per specification and as desired by Engineer in charge |
| 327 | BOUNDARY WALL CIVIL WORK |
| 328 | Excavation in Soil (any type) using Hydrauli Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 329 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 330 | Cement Concrete 1:4:8 with stone ballast or shingle mixing by mechanical meand using concete mixer volumetric type |
| 331 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 332 | Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005. |
| 333 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforment centering and shuttering in foundation & plinth |
| 334 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforment centering and shuttering in superstructure |
| 335 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 336 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 337 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 338 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 339 | Steel Fe-415, Fe-500, Fe-550 (ISI Marked).(Ex Shop in local Market) Extra rate for Steel Fe-415, Fe-500, Fe-550 (Integrated Plant Marked). |
| 340 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 341 | ROAD WORK |
| 342 | Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
| 343 | electronic sensor, compacting with 8- 10 tonnes vibratory roller, finishing and curing. Cement Concrte 1:4:8 |
| 344 | Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 345 | Providing and laying 60mm thick cement concrete interlocking paver block of M-35 grade rubber moulded smooth finish with strong vibratory process of approved size and design/shape laid in Ordinary Grey Colour and pattern over and including 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for LightTraffic Areas such as Pedestrian plazas, shopping complexes, ramps, car parking,office driveways, housing colonies, office complexes,rural roads with low volume traffic, farm houses, beach sites, tourist resorts, local authority foot ways, residential roads, etc |
| 346 | SUB-HEAD - I : INTERNAL WIRING |
| 347 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 348 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 349 | Wiring fan point (With fan box) |
| 350 | Wiring light point |
| 351 | Wiring 6Amp. wall socket point |
| 352 | Wiring 6Amp. Plug control comprising wall socket point |
| 353 | Wiring 16/20Amp. power plug control point |
| 354 | Wiring light point without control switch. |
| 355 | Wiring light point with double control switches. |
| 356 | Wiring light call bell point |
| 357 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 358 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 359 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 360 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 361 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 362 | Wiring Computer terminal point having 2 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered) and 2Nos. 16/20Amp. switch with indicator (Modular accessories). |
| 363 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 364 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 365 | Wiring TV socket point (one module) |
| 366 | PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 367 | Overall size 1.5sq.mm (Un-sheathed) |
| 368 | Overall size 2.5sq.mm (Un-sheathed) |
| 369 | Overall size 4sq.mm (Un-sheathed) |
| 370 | Overall size 6sq.mm (Un-sheathed) |
| 371 | Overall size 10sq.mm (Un-sheathed) |
| 372 | Overall size 16sq.mm (Un-sheathed) |
| 373 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 374 | Call Bell 220/230 volts AC Ding Dong |
| 375 | Modular Blanking Plate (One Module) |
| 376 | Ceiling Rose (Flush Piano type) |
| 377 | Bakelite Batten Holder (Large size) |
| 378 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 379 | Heavy Gauge PVC Conduit Pipe 20mm dia. (Flushed) |
| 380 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 381 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 382 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 383 | Heavy Gauge PVC Conduit Pipe 25mm dia. (on surface) |
| 384 | Heavy Gauge PVC Conduit Pipe 32mm dia. (on surface) |
| 385 | PVC CHANNEL (uPVC TRUNKING):Supply and erection of PVC Channel (uPVC Trunking) with cover of various sizes (On Surface) on wall, Flat angle, internal & external angle, Flat Tee, End cap and mounting boxes including the cost of joint cover, fixing and other petty material etc.:- |
| 386 | PVC Channel (uPVC Trunking) 50mm x 50mm |
| 387 | PVC Channel (uPVC Trunking) 100mm x 50mm |
| 388 | SUB-HEAD II - FANS & LIGHT FIXTURES: |
| 389 | Supply and fixing of IP20 recessed/surface LED Downlighter made of pressure die cast aluminum housing with PC diffuser, CCT 4000K to 6500K Fixture should have minimum efficacy at System level (Not Chip Level) >=minimum 100 lumens/watt with Minimum system Lumens 600 with maximum system wattage of 6W. Life of fixture (Including Driver). The fixture should have BIS certification for LED Driver & Luminaire.Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer. BIS approvedAll above specifications should comply at the same time with all technical specidfication and certifications as approved by office of adviser (Technical),Govt. of Punjab wide letter No. AT2021 GL 1410-1422 DATED 06-05-2021.or latest with prior approval of engineer-in charge at site.All above specifications should comply at the same time with all technical specidfication and certifications as approved by office of adviser (Technical),Govt. of Punjab wide letter No. AT2021 GL 1410-1422 DATED 06-05-2021.Besides this the lighting fixture manfacturer shouid have inhouse NABL accredited lab.or latest with prior approval of engineer-in charge at site. |
| 390 | Supply and fixing of IP20 recessed/surface LED Downlighter made of pressure die cast aluminum housing with PC diffuser, Fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt with Minimum system Lumens 1500 with maximum system wattage of 15W. Life of fixture (Including Driver). The fixture should have BIS certification for LED Driver & Luminaire.Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer. BIS approved All above specifications should comply at the same time with all technical specidfication and certifications as approved by office of adviser (Technical),Govt. of Punjab wide letter No. AT2021 GL 1410-1422 DATED 06-05-2021.or latest with prior approval of engineer-in charge at site. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab.or latest with prior approval of engineer-in charge at site. |
| 391 | Supply and fixing of LED Batten in 20W, 2000 lm, 4ft Extruded aluminum housing fitted with engg. Plastic end plates. Easy fit profiles acrylic diffuser provides smooth light distribution. LED populated on PCB comprising of cool White LEDs connected in series parallel. CCT-3000K ot 6500K as per requirement . Min. efficacy 100 L/Watt , Manufacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parametersAll above specifications should comply at the same time with all technical specidfication and certifications as approved by office of adviser (Technical),Govt. of Punjab wide letter No. AT2021 GL 1410-1422 DATED 06-05-2021.or latest with prior approval of engineer-in charge at site. |
| 392 | Supply and fixing of LED Batten in 40W, 4000 lm, 4ft Extruded aluminum housing fitted with engg. Plastic end plates. Easy fit profiles acrylic diffuser provides smooth light distribution. LED populated on PCB comprising of cool White LEDs connected in series parallel. CCT-6500K, Manufacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parametersAll above specifications should comply at the same time with all technical specidfication and certifications as approved by office of adviser (Technical),Govt. of Punjab wide letter No. AT2021 GL 1410-1422 DATED 06-05-2021.or latest with prior approval of engineer-in charge at site. |
| 393 | Supply and fixing of LED Mirror batten light of 2ft length with a system wattage of 10W with a nominal system lumen output of 1100-1200 lumens and a minimum system efficacy of 100lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum with powder coating & with IP20 protection. The luminaire shall meet IP20 rating and PF ≥ 0.90. The luminiare manufacturer shall provide LM79 report from NABL accrediated lab & LM80 report issued by LED manufacturerAll above specifications should comply at the same time with all technical specidfication and certifications as approved by office of adviser (Technical),Govt. of Punjab wide letter No. AT2021 GL 1410-1422 DATED 06-05-2021.Besides this the lighting fixture manfacturer shouid have inhouse NABL accredited lab.or latest with prior approval of engineer-in charge at site. |
| 394 | Supply and fixing of Heavy duty bulkhead surface type lighting fixture 10W - Minimum 1000lm made up of pressure die-cast aluminium housing and Polyster Powder coated die cast aluminium with High quality polycarbonate diffuser in opal finish for glare free light distribution.The LED used shall be SMD and luminaires shall have system lumen efficacy of >100 lm/W.-IP65/66 Powered by integral electronic LED driver with CCT: 4000K, of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. All above specifications should comply at the same time with all technical specidfication and certifications as approved by office of adviser (Technical),Govt. of Punjab wide letter No. AT2021 GL 1410-1422 DATED 06-05-2021Besides this the lighting fixture manfacturer shouid have inhouse NABL accredited lab.or latest with prior approval of engineer-in charge at site. |
| 395 | Supply and fixing of single unit 10 Watt LED -IP65/66 aviation obstruction light complete with transformer and LED spiral etc complete in all respect |
| 396 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 3 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 397 | Supplying, erection, connecting, testing and commissioning of 450 mm sweep wall mounted fan rating complete as required,Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 398 | Supply and erection of ventilation fan, sweep 250mm packing dimensions, normal speed 1200 or better, air delivery 800 or better RPM , air delivery 750 Cubic meter per hr, low noise level, power consumption 27 watt, light and rust free body, powerfull air suction including erection, connections and testing etc. complete in all respect as desired by engineer incharge of work at site. |
| 399 | a) 250 mm 800 RPM |
| 400 | Supplying, erection, connecting, testing and commissioning of following size exhaust fan with sweep 300 mm Air Delivery > 1600 cu. mtr./hr,input power 72 watt,oil and dust proof coating, with heavy duty motor with double ball bearing, complete with suitable coloured gravity louver and connection with 3 core flexible wire as required. |
| 401 | a) 300 mm 900 RPM |
| 402 | Supply and fixing of illuminated exit sign with 1 x 6 watt LED lamp including providing maintenance free batteries & charger capable of working for 2 hr duration mounted on ceiling/wall complete with the approved EXIT self adhesive labels as per site requirement as required includingconnection with 1.5 sqmm FRLS PVC insulated copper conductor |
| 403 | SITC Occuswitch is a movement detector with a built-in switch. It will switch off the lights in a room or area when it is vacated and thus save energy. Occuswitch can switch any load up to 6A and control an office area of around 20 sq.m. for small movements (e.g. desk work) and arround 50 sq.m. for large movements (e.g. walking). Its smart daylight sensing technology offers additional saving through daylight override and daylight switching |
| 404 | SUBHEAD- III: M.V. PANELS/ DISTRIBUTION BOARD |
| 405 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 406 | SP&N Double Door Distribution Board 4 way each |
| 407 | SP&N Double Door Distribution Board 8 way each |
| 408 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 409 | TP&N Horizontal Double Door Distribution Board 6 way each |
| 410 | TP&N Horizontal Double Door Distribution Board 8 way each |
| 411 | TP&N Horizontal Double Door Distribution Board 12 way each |
| 412 | TP&N Vertical Double Door Distribution Board 4 way each |
| 413 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 414 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 415 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 416 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 417 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 418 | MCB Triple Pole 40amp. (10kA, Curve-C) |
| 419 | MCB Triple Pole 50, 63amp. (10kA, Curve-C) |
| 420 | RCCB's:Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 421 | RCCB Double Pole 32/40amp., Sensitivity 100mA |
| 422 | RCCB Four Pole 32/40amp., Sensitivity 100mA |
| 423 | RCCB Four Pole 63amp., Sensitivity 100mA |
| 424 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 425 | MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 426 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 427 | MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 428 | Building LT PanelsSupply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with bottom and top cable entriesElectrical panel with ACB (50KA, 4 Pole Elect draw out Micro Processer Release) and MCCB's (four Pole 36 KA with Microprocessor above qnd equal 250 A and below thermal magnetic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminiumbusbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grouting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Meter, current transformer and selector switches etc. and insurment fuse The switch board shall be IP 42 and fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall comply IS 61439 |
| 429 | Girls hostel non essential |
| 430 | LT Panel Non Essential (Specification as per above desription) |
| 431 | Incomer: |
| 432 | 1 No 800 Amps ACB 50 KA, with Over load & Short ciruit protection |
| 433 | 1 Set phase indication lights (R, Y, B) |
| 434 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 435 | 1 No. 0-800 Amp. Ammeter (digital type) with inbuilt ASS |
| 436 | BUS BARS: |
| 437 | 1000 Amps. 4P Al bus bars (36 KA) |
| 438 | Outgoings: |
| 439 | 16 Nos 125 Amp FP MCCB (36 KA), |
| 440 | Girls hostel essential |
| 441 | LT Panel Essential (Specification as per above desription) |
| 442 | Incomer: |
| 443 | 1 No 500 Amps MCCB 36 KA, with Over load & Short ciruit protection |
| 444 | 1 Set phase indication lights (R, Y, B) |
| 445 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 446 | 1 No. 0-500 Amp. Ammeter (digital type) with inbuilt ASS |
| 447 | BUS BARS: |
| 448 | 630 Amps. 4P Al bus bars (36 KA) |
| 449 | Outgoings: |
| 450 | 15 Nos 125 Amp FP MCCB (36 KA), |
| 451 | 5 Nos 63 Amp FP MCCB (36 KA), |
| 452 | Main UPS Panel (Specification as per above desription) |
| 453 | Incomer: |
| 454 | 1 No 160 Amps MCB 25 KA, |
| 455 | 1 Set phase indication lights (R, Y, B) |
| 456 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 457 | 1 No. 0-160 Amp. Ammeter (digital type) with inbuilt ASS |
| 458 | BUS BARS: |
| 459 | 160 Amps. 4P Al bus bars (25 KA) |
| 460 | Outgoings: |
| 461 | 15 Nos 40 Amp FP MCCB ( 25 KA), |
| 462 | 2 Nos 40 Amp DP MCCB ( 25 KA), |
| 463 | Boys hostel non essential |
| 464 | LT Panel Non Essential (Specification as per above desription) |
| 465 | Incomer: |
| 466 | 1 No 800 Amps ACB 50 KA, with Over load & Short ciruit protection |
| 467 | 1 Set phase indication lights (R, Y, B) |
| 468 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 469 | 1 No. 0-800 Amp. Ammeter (digital type) with inbuilt ASS |
| 470 | BUS BARS: |
| 471 | 1000 Amps. 4P Al bus bars (36 KA) |
| 472 | Outgoings: |
| 473 | 12 Nos 125 Amp FP MCCB (36 KA), |
| 474 | Boys hostel essential panel |
| 475 | LT Panel Essential (Specification as per above desription) |
| 476 | Incomer: |
| 477 | 1 No 500 Amps MCCB 36 KA, with Over load & Short ciruit protection |
| 478 | 1 Set phase indication lights (R, Y, B) |
| 479 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 480 | 1 No. 0-500 Amp. Ammeter (digital type) with inbuilt ASS |
| 481 | BUS BARS: |
| 482 | 630 Amps. 4P Al bus bars (36 KA) |
| 483 | Outgoings: |
| 484 | 12 Nos 125 Amp FP MCCB (36 KA), |
| 485 | 5 Nos 63 Amp FP MCB (36 KA), |
| 486 | SUBHEAD: - IV - EARTHING G.I. EARTHING: |
| 487 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 488 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 489 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): |
| 490 | Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. |
| 491 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface) |
| 492 | COPPER EARTHING: |
| 493 | COPPER EARTHING (Upto 8 metre in Length): |
| 494 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 495 | Earthing with 25mm x 3mm Copper Tape (upto 8Metre in Length) |
| 496 | Earthing with 40mm x 5mm Copper Tape (upto 8Metre in Length) |
| 497 | 8 SWG COPPER EARTHING : |
| 498 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 499 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 500 | COPPER EARTHING STRIP (As Additional Length): |
| 501 | Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 502 | Additional Length 25mm x 3mm thick Copper Tape |
| 503 | Additional Length 20mm x 3mm thick Copper Tape |
| 504 | Additional Length 40mm x 5mm thick Copper Tape |
| 505 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 506 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 507 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 508 | SUBHEAD-V- LIGHTNING PROTECTION SYSTEM |
| 509 | Supply, Erection, Installation & Commissioning of External Lightning Wide Area Protection System based on pro-active Early Streamer Emission (ESE) Technology. No external power source required. Break down time not more than 245.5 Micro second. Wind Resistance up to 120miles/hours. Produces a leader of not less than 2x10E8 V/m/s in the lightning generated electromagnetic field with Level-I protection radius of 79 meters at 5 mtr. Mast including mast for supporting the device. Device confirming to NFC17-102 & UNE 21186 standards & CPRI Tested. |
| 510 | PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 70sq.mm (Un-sheathed) |
| 511 | Supply, Erection, Installation & Commissioning of Lightning Event Counter for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor and the triggering impulse should be > = 1.5 KA for 8/20µs. The Lightning Event Counter should be robust, non-resettable mechanical counter with IP65 rated enclosure suitable for external application. |
| 512 | COPPER EARTHING (Upto 8 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 40mm x 5mm Copper Tape (upto 8Metre in Length) |
| 513 | SUBHEAD - VII - CABLE TRAY |
| 514 | CABLE TRAY: |
| 515 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 516 | Cable Tray Size 450mm x 50mm x 50mm (2mm thick) |
| 517 | SUB-HEAD - VIII : LT CABLES |
| 518 | XLPE INSULATED LT CABLES: |
| 519 | XLPE INSULATED ARMOURED CABLES (LOOSE): |
| 520 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 521 | Overall size 25sq.mm (3½ Core) Armoured (Loose) |
| 522 | Overall size 50sq.mm (3½ Core) Armoured (Loose) |
| 523 | Overall size 150sq.mm (3½ Core) Armoured (Loose) |
| 524 | Overall size 240sq.mm (3½ Core) Armoured (Loose) |
| 525 | Overall size 300sq.mm (3½ Core) Armoured (Loose) |
| 526 | Overall size 16sq.mm (4Core) Armoured (Loose) |
| 527 | XLPE INSULATED ARMOURED CABLES (ON SURFACE): |
| 528 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 529 | Overall size 300sq.mm (3½ Core) Armoured (On-Surface) |
| 530 | Overall size 400sq.mm (3½ Core) Armoured (On-Surface) |
| 531 | Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 532 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 533 | Aluminium thimble cable Core size 10 -16sq.mm |
| 534 | Aluminium thimble cable Core size 25 -35sq.mm |
| 535 | Aluminium thimble cable Core size 50sq.mm |
| 536 | Aluminium thimble cable Core size 70sq.mm |
| 537 | Aluminium thimble cable Core size 95sq.mm |
| 538 | Aluminium thimble cable Core size 120sq.mm |
| 539 | Aluminium thimble cable Core size 150sq.mm |
| 540 | Aluminium thimble cable Core size 185sq.mm |
| 541 | Aluminium thimble cable Core size 240sq.mm |
| 542 | Aluminium thimble cable Core size 300sq.mm |
| 543 | Aluminium thimble cable Core size 400sq.mm |
| 544 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 545 | 4 X 16 sq. mm (28mm) |
| 546 | 3½ X 25 sq. mm (28mm) |
| 547 | 3½ X 50 sq. mm (35mm) |
| 548 | 3½ X 150 sq. mm (50mm) |
| 549 | 3½ X 240 sq. mm (62mm) |
| 550 | 3½ X 300 sq. mm (70mm) |
| 551 | S/E of LT Straight Through Joint Kit Cast Resin type for 1.1 KV grade PVC/XLPE cable as desired by the Engineer in charge of the site:- |
| 552 | Straight Through Joint Kit Resin Cast type for Cable Size 3½/4 Core 300 sq. mm |
| 553 | Straight Through Joint Kit Resin Cast type for Cable Size 3½/4 Core 240 sq. mm |
| 554 | Straight Through Joint Kit Resin Cast type for Cable Size 3½/4 Core 120 sq. mm - 150 sq. mm |
| 555 | Straight Through Joint Kit Resin Cast type for Cable Size 3½/4 Core 95 sq. mm |
| 556 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 557 | Double Walled Corrugated HDPE Pipe 200/ 170mm (Outer/ Inner dia.) |
| 558 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 559 | Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.) |
| 560 | SUBHEAD-IX : ELECTRICAL SUB STATION |
| 561 | TRANSFORMER (11 KV / 0.4 KV) |
| 562 | Supply, testing & commissioning of Outdoor mounted type 11 KV / 433 Volt 2500 KVA Transfomer (as per IS : 2026, P1 to P5), 3 phase, 6.25% impedance, Dyn 11 vector group, 50 cycles, (ONAN) oil immersed naturally cooled, step down, copper wound, continuous duty, temperature rise above 50oC in oil by thermometer 40oC, in winding by resistance 45oC and other standard accessories as required including the suitable sized cement concrete foundation (Drawings as approved by the Engineer incharge), complete in all aspects as per satisfaction of Engineer Incharge,including the followings : |
| 563 | The Transformer losses should confirm to IS : 1180 (Level - 3 ) with latest amendments at the time of instalation. |
| 564 | a) Cable Termination box with disconnecting facility for 11 KV Upto 300 3C-150 sq mm XLPE cable at 11 KV side |
| 565 | b) LV side box suitable for suitable Amp bus duct termination |
| 566 | c) Automatic On Load Tap Changer +5% to -15% @ 1.25% in 16 equal steps with RTCC Panel (Remote tap changer control panel) consisting of followings - |
| 567 | High torque, electric motor suitable for 415V 3 Ph. 50 Hz., AC supply. |
| 568 | Motor drive and energy accumulator. |
| 569 | Monitor isolating device with overload protection. |
| 570 | Contactors for Forward & Reverse operations of motor. |
| 571 | Oil Surge Relay |
| 572 | “RAISE / LOWER” control for local operation. |
| 573 | “LOCAL / REMOTE” control selector switch. |
| 574 | “RAISE / LOWER” limit switches. |
| 575 | Stepping Relay. |
| 576 | Auxiliary Transformer. |
| 577 | d) Bidirectional rollers. |
| 578 | e) Oil Conservator with filter cap, drain plug & oil level gauge |
| 579 | f) Earthing terminals 2 nos for body earthing. |
| 580 | g) 0.415 KV neutral seperately bought out on a bushing for neutral earthing. |
| 581 | h) Neutral CT as required. |
| 582 | i) Pressure release device. Double diaphragm explosion vent. |
| 583 | j) Radiators Detachable type with top & bottom shut off valve. |
| 584 | k) First filling of filtered dehydrated oil as per IS : 335 including make up fill during installation & 10% extra. |
| 585 | l) Silica gel breather with connecting pipe & oil seal. |
| 586 | m) Rating, Diagram & Terminal marking plate of SS. |
| 587 | n) Sampling Valves for filteration, drainage and filling with plugs. |
| 588 | o) Air release plugs. |
| 589 | p) Thermometer pocket with plug. |
| 590 | q) Lifting Lugs. |
| 591 | r) Double float Buchholz relay with gas release cock, alarm & shut off valve on either side with separate set of contacts for trip and alarm. |
| 592 | s) 150 mm Winding temperature indicator (WTI) with alarm. (for 800 KVA & above) |
| 593 | t) 150 mm Oil temperature indicator (OTI) with alarm |
| 594 | u) Marshalling Box. |
| 595 | v) Clamping device. |
| 596 | w) Jacking Pads. |
| 597 | x) Ladder with safety device for access to the top of transformer tank. |
| 598 | The work shall be complete in all respects up to the satisfaction of Engg-in-charge. |
| 599 | 2500 KVA |
| 600 | HT PANEL EQUIPMENTS |
| 601 | HT PANEL- |
| 602 | Supply,installation, testing & commissioning of indoor type floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 54, The switchgear boards shall have a single front, single tier, fully compartmentalized, metal enclosed construction complying with clause No. 3.102 of IEC 62271-200, comprising of a row of free standing floor mounted panels. Each circuit shall have a separate vertical panel with distinct compartments for circuit breaker truck, cable termination, main bus-bars and auxiliary control devices. The adjacent panels shall be completely separated by steel sheets except in bus-bar compartments. The Service Class Continuity of Switchgears shall be LSC 2B-PM (as per IS/IEC 62271-200) • The Switchgear shall have an Internal Arc Classification of IAC AFLR. Switchgear shall have an internal arc of 31.5kA for 1 second.In case of any Inspection window provided on breaker compartment door, same should also be in line with IAC classifications. comprising of 1250Amp, continuous rated Copper busbars and droppers, 01nos. Rack-In-Rack-Out Handle, structure made from AluZinc/GI sheets to prevent corrosion and rusting.The complete panel incl. HT and LT chamber shall be manufactured by approved OEM at its own facility, and same will be verified via stage/final inspection. License parter, system integrator, panel builder, half-panel concept is not allowed. 11 KV 4 VCB HT Panel fully encapsulated pole VCB breakers (1 incomer and 3 out goings), totally enclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker, having capacities as mentioned below, single break, trip free mechanism, motorised charged and auto closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A. C. supply with short circuit fault level of 31.5 kA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but continuous rated Copper busbars and droppers , Cu. earth bar, earth bar, breaker featured with mechanical ON / OFF indicator with hand trip device, spring release coil, shunt trip coil, control voltage of 24 Volt DC, TNC, LED type indicating lamps for phases and trip conditions and auxiliary switch of 6 NO + 6 NC and equipped with following switchgears and accessories.The panel should be suitable for connections for up to 3 x 300 sq.mm XLPE 11 KV cable (cable entry from bottom/top/side), end termination with heat shrinkable jointing material etc. as required. (The Cost of end termination not included in this item) |
| 603 | power pack ( 1 working & 1 standby) with 220 Volt AC input & 24 Volt DC continuous output suitable for indicating lights & closing / tripping / indication of 5 Nos. HT panel boards with 2 Nos. 12 Volts each maintenance free batteries of suitable AH (Min 4 Hrs back up for each relays & indication) each, charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of Ammeter & Voltmeter i/c connections with 2.5 sq.mm FRLS insulated copper conductor cable etc. including DC DB consisting of required MCB's for DC supply distribution to panels as required. |
| 604 | 2 Nos INCOMING each consist of - |
| 605 | 2 Nos. 1250 Amp. VCB breakers with followings in each breaker - |
| 606 | 11 KV, 1250Amp, 31.5kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03 Nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) |
| 607 | (a) 1 set (3 nos) 11 KV / √3 / 110 / √3 Volts drawout type PT Class 1.0 accuracy and 50 VA burden with 1 No. Voltmeter (0-12 KV), digital type, selector switch for voltmeter and protection fuses/MCB for HT metering. |
| 608 | (b) 3 nos. dual core dual ratio CTs of ratio 200/100/1/1A of 7.5 VA burden and accuracy class-1.0 for metering and class 5P10 for protection. |
| 609 | (c) 1 No. - (0-250A) Ammeter, digital type with selector switches. |
| 610 | (d) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT+05PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like (1) directional over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) residual and three-phase under-voltages/over-voltages(4) Synchronism and Energizing Check before breaker closing to prevent un-syncronized mixing of supplies(5) circuit-breaker-failure alarm, (6) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol.The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage etc. and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with power & frequency measurements and suitably labelled status LEDs.TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software.Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously. |
| 611 | (e) Master trip relay |
| 612 | (f) Trip circuit supervision relay |
| 613 | (g) Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, KVAH, KVARH, PF, HZ & MDI with RS 485 port. |
| 614 | (h) Timer and TNC switch |
| 615 | 1 Nos Buscoupler |
| 616 | 1 Nos. 1250 Amp. VCB breakers with followings in each breaker - |
| 617 | 11 KV, 1250Amp, 31.5kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03 Nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) |
| 618 | 4 Nos OUTGOING each consist of- |
| 619 | 2 Nos. 800 A VCB breakers with followings in each breaker - |
| 620 | 11 KV,800Amp, 31.5kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03 Nos. encapsulated vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24VDC) |
| 621 | Note - Provide all type of Protection, Auxillary relays, release for the transformer protection as the outgoing feeders shall feeds the power to transformer. |
| 622 | (a) 3 nos. dual core dual ratio CTs of ratio 50/1/1A of 7.5 VA burden and accuracy class-1 for metering and class 5P10 for protection. |
| 623 | (b) (0-50A) Ammeters, dual scale digital type & selector switches for ammeters. |
| 624 | (c) Main Protection Relay shall be numerical LED Relay confirming to IEC60255, having 04CT+05PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like (1) directional over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) residual and three-phase under-voltages/over-voltages(4) Synchronism and Energizing Check before breaker closing to prevent un-syncronized mixing of supplies(5) circuit-breaker-failure alarm, (6) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol.The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage etc. and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with power & frequency measurements and suitably labelled status LEDs.TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software.Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously. |
| 625 | (d) 12 window Annunciation panel with necessary relays, audio and visual indicators and push buttons. |
| 626 | (e) Auxilliary relay for Buchholtz / OTI / WTI |
| 627 | (f) TNC switch |
| 628 | (g) Master trip relay |
| 629 | (h) Trip circuit supervision relay |
| 630 | HT Panel - 06 as described above |
| 631 | Makes : The main HT panel shall be as per IEC61439 (TTA) from Authorised License Partners |
| 632 | Main L.T. Panel |
| 633 | Design, manufacture, supply , installation, inspection, handling, assembling, affecting proper connections, testing and commissioning of Main L.T. Panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP42. Panel Construction should be of 2mm folded metal sheets thickness, except for few internal partitions. The Main LT Panel should be tested according to the latest standards, IEC61439-1&2 and shall be certified by 3rd party Certification body as per IEC 61439-1 & 2. Test reports without certificate shall not be considered admissible proof of compliance. The Certifying Authority shall be qualified under ISO/IEC 17065 as per IEC 61439-1. |
| 634 | The main LT Panel shall be Internal arc tested for 65 KA as per IEC61641 with IK09 tested with double door design . The noble parts of panel ( Busbar Support,Vertifcal Upright,Corner's) shall be strictly supplied by OEM to System Integrator. System Integrator is not allowed to supply these parts in panels.The MCCB termination to be done at the rear side and rear terminals to used to avoid any live parts. The GA of system integrator to be seal & sign by OEM before submission for approval |
| 635 | Makes : The main LT panel shall be as per IEC61439 (TTA) from Authorised License Partners Authorized certificate and agreement copy with OEM to be submit while drawing approvals through contractor. Tender based authorization or any other certifications shall not be valid.Further,Only OEM's system integrator for TTA panels as per IEC61439 (Models as specified above)shall only be allowed to manufacturer & supply Non TTA panels also like HVAC, Sub Panels, AHU Panels,Control Panel,Fire Fighting Panel to maintain the high quality vendor for complete LT Panels.No other manufacturer shall supply NON TTA panels even if it is specified in make list and this BOQ shall supercedes all previous corrigendum/amedmend/SLD/List of makes issued for any make/model/rating during tendering |
| 636 | INCOMERS from 3 Nos. 2500 KVA Transformers |
| 637 | 3 nos ACB 4000A 4P EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 638 | The ACB shall be electrically and mechanically interlocked with the bus coupler, DG incomers and other transformer incomers. |
| 639 | Outgoings for 3 Nos. Hybrid Capacitor Panel (1000 KVAR capacitors with detuned recators + 300A AHF) |
| 640 | 3 nos. 1600 amp, FP ACB with Inbuilt OL,SC,EF (66 KA) for each transformer incomer meant for connecting Hybrid Capacitor Panel (Total 800 KVAR capacitors with 7% detuned Aluminium recators + 300A AHF) |
| 641 | 1 nos. 32 amp TP MCCB with Inbuilt OL,SC,EF (Without use of any external device)(35 KA) for OLTC (for each transformer incomer) |
| 642 | Protection releases / relays, Metering & Accessories for each Transformer incomers. |
| 643 | Over Voltage / Under Voltage relay / release with timer. |
| 644 | Restricted earth fault relay. |
| 645 | Master trip relay. |
| 646 | Trip Circuit Supervison relay. |
| 647 | TNC switch. |
| 648 | Auto manual selector switch. |
| 649 | 1 nos. 0-500 volt range digital type voltmeter with selector switch |
| 650 | 1 set of 3 CT's of ratio 1650/5A, Class 1.0 accuracy 15 VA burden for metering. |
| 651 | 1 set of 3 CT's of ratio 1650/5A, Class 1.0 accuracy 15 VA burden for APFCR. |
| 652 | 1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse. |
| 653 | 1 set of 4 CT's of ratio 1650/1A, Class PS for protection. |
| 654 | 1 no. 0-1650 Amp range digital type ammeter with selector switch. |
| 655 | Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. (or Dual meter) |
| 656 | Power factor meter. |
| 657 | Frequency meter. |
| 658 | 4 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons. |
| 659 | 5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB. |
| 660 | INCOMERS from 2 Nos 300 KWPe Solar Power Plant each consist of |
| 661 | 1nos. ACB 800A 4P EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 662 | INCOMERS from 3 Nos 1010 KVA D G sets each consist of |
| 663 | 1 nos. ACB 1600A 4P EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 664 | INCOMERS from 1 Nos 500 KVA D G sets |
| 665 | 1 nos. ACB 800A 4P EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 666 | Protection releases / relays, Metering & Accessories for each DG set incomers |
| 667 | Over Voltage / Under Voltage relay / release with timer. |
| 668 | IDMT earth fault relay. |
| 669 | Master trip relay. |
| 670 | Trip Circuit Supervison relay. |
| 671 | Reverse power relay. |
| 672 | TNC switch. |
| 673 | Auto / manual / test selector switch |
| 674 | 1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB. |
| 675 | 0-63 volt range digital type voltmeter with selector switch |
| 676 | 1 set - 3 CTs of suitable ratio for every DG , Class 1.0 accuracy 15 VA each burden for metering. |
| 677 | 1 set - 3 CTs of suitable ratio , Class 5P20 accuracy 20 VA each burden for protection. |
| 678 | 0-800 Amp range digital type ammeter with selector switch. |
| 679 | Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. (or Dual meter) |
| 680 | Frequency meter. |
| 681 | Power Factor meter. |
| 682 | 1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing. |
| 683 | 3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons. |
| 684 | 5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB. |
| 685 | 12 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares. |
| 686 | Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop. |
| 687 | Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps. |
| 688 | DG control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out. |
| 689 | 1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (1010 KVA) |
| 690 | Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same. |
| 691 | The ACB shall be electrically and mechanically interlocked with the bus coupler and Transformer incomers. |
| 692 | BUS COUPLER |
| 693 | 2 nos ACB 4000A 4P EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 694 | Protection releases / relays, Metering & Accessories for Bus Coupler (s) |
| 695 | Trip circuit supervision relay |
| 696 | TNC switch. |
| 697 | Auto / manual selector switch |
| 698 | 5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB. |
| 699 | The bus coupler shall be electrically and mechanically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up. |
| 700 | BUS BARS |
| 701 | 3 sections of 5000 AMP, 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. |
| 702 | The current density of bus bar up to 1000 Amp shall be minimum 1.00 sq mm / amp & for 1250 / 1600 amp shall be minimum 1.30 sq.mm / amp and for 2000/2500 /3200/4000 Amp shall be minimum 1.60 sq mm / amp. |
| 703 | The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. |
| 704 | Bus PT Module 5 Nos., each with Following: |
| 705 | 3PH. 415/v3/110/v3 V 100VA with Fuses. |
| 706 | R,Y,B Ind. Light with Control Fuses |
| 707 | Voltage Relay |
| 708 | (Note - All the indication & metering shall be done through 110V from secondary of PT's. No indication lamps & metering should not be operated at 415 Volts.) |
| 709 | PLC for load management / automation |
| 710 | Design, manufacturing, testing at works, supply of PLC BASED , AUTOLOAD TRANSFER, AUTOLOAD BALANCING PANEL FOR 2 nos. 1010 KVA & 1 nos. 500 KVA complete as required to acheive the desired functions. |
| 711 | PLC shall be provided in main LT panel for interlocking between different incomers and bus couplers to avoid unintentional paralleling of different supplies. |
| 712 | PLC is not envisazed for D G synchronization |
| 713 | PLC with VIEW PANEL. |
| 714 | In addition to required hardware and software following components shall also be provided. |
| 715 | Based on the load requirement only required no. of DG sets shall be operated. |
| 716 | Monitoring of DG set safeties (mechanical as well as electrical). |
| 717 | PLC Hardware as required |
| 718 | Auxiliary relays/contactor/metering/protection etc as required |
| 719 | 230 V AC, UPS alognwith battery of suitable back up of suitable rating |
| 720 | Annunciators as required |
| 721 | One no. Battery charger set consisting of Transformer / Rectifier, DC ammeter, DC voltmeter, Charging rate selector switch, Off/Trickle/boost. |
| 722 | All control wiring from PLC to various feeders with min. of 2.5 sq mm copper FRLS cable. |
| 723 | The PLC provided for Load Management & for interlocking of Breakers shall perform to achieve the system as described in given Main Schemetic Diagram. |
| 724 | OUTGOINGS - |
| 725 | All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT's of accuracy class 1.0 |
| 726 | All outgoing feeders fed from DG Bus Bar shall be provided with energy analyser / electronic dual reading KWHR meter with RS 485 communication port, CT's with accuracy class 1, control circuits and wiring as per SLD. |
| 727 | 2 nos ACB 2500A ACB TPN EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 728 | 3 nos ACB 1600A ACB TPN EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 729 | 5 nos ACB 1250A ACB TPN EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 730 | 2 nos ACB 1000A ACB TPN EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 731 | 2 nos ACB 800A ACB TPN EDO, Icu = 66 kA, 415V LSIG with touch release having onboard modbus TCP/IP communication.The ACB should also be supplied communcation redunancy option that means (2nos Modbus TCPIP) should be supplied. For communication,the gateway and on premises energy and assest manager software should be of switchgear manufacturer only. No other makes or scada is allowed in this for desktop viewing software. The integration of communication from ACB to gateway to energy & assest management software of OEM shall be in scope of the System Integrator |
| 732 | All MCCB's should be ICS=100%= ICU. Single frame from 32Amp to 250Amp & 400 / 630Amp of single frame. MCCB upto 250Amp should be Adjustable Thermal Magnetic & above 250Amp should be Microprocessor with Built-in μP based trip unit having protection functions LSIG. Variable current setting for L,S,I and G and variable time delay setting for L,S and G. Neutral O/L protection possible with 3P MCCB (with External Neutral CT). Last Fault trip history on LCD screen of MCCB i.e Faulty phase, Type of Fault and interrupted current. |
| 733 | 8 nos. 630 AMPS 4P MCCB with Inbuilt OL,SC,EF (Without use of any external device)(50 KA) |
| 734 | 3 nos. 500 AMPS 4P MCCB with Inbuilt OL,SC,EF (Without use of any external device)(50 KA) |
| 735 | 1 nos. 400 AMPS 4P MCCB with Inbuilt OL,SC,EF (Without use of any external device)(50 KA) |
| 736 | 2 nos. 250 AMPS 4P MCCB with Inbuilt OL,SC,EF (Without use of any external device)(50 KA) |
| 737 | 2 nos. 200 AMPS 4P MCCB with Inbuilt OL,SC,EF (Without use of any external device)(35 KA) |
| 738 | 2 Nos. 160 Amps 4P MCCB(35KA) |
| 739 | 4 Nos. 100 Amps 4P MCCB(35KA) |
| 740 | Main LT Panel as described above |
| 741 | Hybrid POWER FACTOR CORRRECTION PANEL - (1000KVAR+300Amp) |
| 742 | Makes : The main panel shall be as per IEC61439 (TTA) from Authorised License Partners |
| 743 | Design and supply of Hybrid Power Factor Correction Panel (APFC) of capacity 440V, 3-phase, 50 Hz., The passive 1000 KVAr stage ratings shall be 4x25kVAr + 4x50kVAr + 7x100kVAr. The APFC Panel shall be fully type tested and shall comply to IEC 61439-1&2 and IEC 61921 Or IS 16636-2017. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof. The degree of protection of enclosures system of the APFC Panel shall be min. IP41 in accordance with IEC 60529. The capacitor bank shall be Internet of things (IoT) enabled and communicable/ integrable with EMS .The APFC panel should have the capability for environmental monitoring where it is able to provide the real time data for the temperature and humidity inside the panel ambient. The environmental sensors shall be used with a access point, which can be used for multiple sensors, using Green Power wireless communication protocol to transfer the information on real time basis to have the exact and detailed temperature monitoring of the Cap bank conforming to IS13341:1992 & IS 13440:1993 floor mounted design, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m above sea level. |
| 744 | The OEM's specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf. The APFC Panel manufactured by OEM's only will be accepted & factory acceptance test ( FAT ) will be carried out at OEM's plant only. |
| 745 | (A) Insulated bus bar assembly made from Aluminium and rated of 1800 Amps capacity. The short circuit withstand capacity shall be 65 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. |
| 746 | ( B) The incomer of the APFC Panel shall be a 1600 Amp, ACB, 3P, 50kA Microprocessor based ET trip systems with thermal memory with O/L & S/C protection, Icu=Ics=Icw=50kA for 1sec @440V, ACB shall have standard extended rotary handle, spreaders, phase barrier. ACB shall be of certified design confirming to IEC 60947-1,2 & 3. |
| 747 | (C) Capacitor Units: The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 480V and shall have a maximum over current capacity of 1.8 In & Peak inrush Current 250In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors (50V in 1min) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993, 13341-1992 & IEC -60831-1&2. |
| 748 | (D) Reactors : The de-tuning reactors shall be connected in series with each capacitor stage and shall be of iron cored type. The reactors shall have relative impedance of 7%, with a de-tuning frequency of 190 Hz. approx. The reactors shall have built in thermostats to protect from overheating. The reactor insulation shall be min. Class “H” rated at 180 degree C.. The reactors shall be of certified design confirming to IEC-60076 - 6. |
| 749 | (E) Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB with an electronic over-current relay for short-circuit and overload protection. The electronic over-current relay shall be adjusted to trip if the RMS current of the stage exceeds the overload setting. The MCCB shall be of certified design confirming to IEC 60947-1,2 & 3. |
| 750 | (F) PF Regulator : Advanced Range PF Regulator shall have 10 steps with a LCD Display, Voltage Range : 90V - 550V, 50, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326. |
| 751 | (G) In addition to the PF Controller, the capacitor bank, should also have an energy server which would collect, store, and provides web access and visualization to various energy parameters and enable remote supervision from BMS. To ensure maximum utilization, enable remote commissioning / trouble shooting of the capacitor bank, the energy server should monitor and display the following parameters remotely through a Web Page.- Status of stages (open / close / faulty).- Real time capacitance value of the connected stage.- Initial capacitance value.- Number of operation of stages ( stage utilization / operation)- energy parameters like : I, V , P , Q, S , Operating PF, Target PF, Operating Temperature , Max Temperature, % THD V, %THD I- Display of alarms - Trending curves of historical recorded data. |
| 752 | (H) Stage Contactor : The electromagnetic contactors shall be rated for 660 Volts and shall be capacitor duty 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1. |
| 753 | (I) Ventilating fans of required size shall be used to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks shall be of type tested design and temperature rise test report of the capacitor bank. |
| 754 | (J)Hybrid panel should be ethernet enabled comprising of at least (300 amp) of IGBT based active filter ( harmonics , Power factor Compensation) suitable for operation on 415 ±10% volts, 50 Hz AC 3 phase 3 wire supply system, Require IGBTs with 3 level topology Inverter,2nd to 51st, discrete; fully selectable per harmonic order (amplitude and on/off), base active technology Control response time 25μs, Harmonic mitigation required less than 2 cycle & power factor Correction type should be less than 1/4th cycle. Harmonic attenuation more than 97% .Active Filter, Standards compliance/certification:- CULUS (UL508 , CSA 22.2 No. 14) ,CE Certified, ABS, |
| 755 | The HYBRID PFC Panel, should also have an energy server which would collect, store, and provides web access and visualization to various energy parameters and enable remote supervision. To ensure maximum utilization, enable remote commissioning / trouble shooting of the capacitor bank, the energy server should monitor and display the following parameters remotely through a Web Page.- Status of Active Filter & Capacitor Banks The Hybrid panel shall be factory built and design, design warranty, including performance warranty shall be from OEM (capacitor & AHF manufacturer). In addition to the advanced PF controller, the capacitor bank, should be IOT enabled i.e., it should collect, store, and provides web access, visualization of various energy parameters directly over ethernet network and enable remote supervision independently as well as from existing EMS. |
| 756 | AUTOMATIC FIRE DETECTION & SUPPRESSION SYSTEM in PANEL |
| 757 | Supply, Installation, Testing & Commissioning of Automatic Direct pressure Release System for Electrical Panel application utilising 2.5 LB/ 5 LB/ 10 LB Novec 1230/ FK5-1-12/ FK5-1-12 clean agent for Electrical Panels panels. The tested system must be approved for Enclosed and Ventilated (Natural and Forced Airlflow) Electrical Panels. The cylinder made of mild steel TPED approved along with sturdy metal bracket having direct low pressure discharge valve having safety brust disc for over pressurization and ball valve with open and closed option. The DLP valve having push on connector for tube to be connected with screw mechanism. The pressure guage having integrated pressure switch for visual and automatic monitoring of system pressure . The clean agent Novec 1230/ FK5-1-12/ FK5-1-12 to be filled in approved filling plant. The heart of the system linear heat sensing tube made of special polymer red colour 4mm I.D. 6mm O.D. pressurized with Nitrogen to be installed as per the OEM Manual. All the tube fittings to be OEM supplied .The system to be designed,installed and commisioned as per system manual. The system installer to be trained and certiifed by OEM of the system activation during gas discharge. |
| 758 | SITC of 2.0 KG clean agent (FK5-1-12), DLP Assembly with Automatic valve mounted on cylinder, push in connector for tube, 2Kg (KF5-1-12) (UL/FM/ gas, mounting bracket, complete in all respect as desired by the Engineer in charge of work at site. |
| 759 | SITC of 4.0 KG clean agent (FK5-1-12), DLP Assembly with Automatic valve mounted on cylinder, push in connector for tube, 4Kg (KF5-1-12) (UL/FM/) gas, mounting bracket. Complete in all respect as desired by the Engineer in charge of work at site. |
| 760 | SITC of Linear pneumatic heat Detection Tube with all necessary fittings & supports. Complete in all respect as desired by the Engineer in charge of work at site. |
| 761 | Master Control Unit with Audio Visual Alarm with wiring to make complete system operational . The control Panel should have provision for integration with fire Alarm /SCADA/BMS System. |
| 762 | Miscellaneous |
| 763 | Supply, erection, testing & commissioning of 230 V, single phase, 2 wire, A.C. to 24V D.C. 180 AH sealed maintenance free batteries with semiconductor/ IGBT (half wave rectifier) with auto-manual trickle boost facility battery charging units complete including 1 No. Distribution board having 63 Amps DP MCB incomer and 12 No. 16/ 20 Amps DP MCBs (D.C. duty) as outgoing complete as required as per technical specifications. |
| 764 | Supplying and laying of 1000 mm wide x 3 mm thick insulated mat made from highly electrical resistant elastomer of tested quality to withstand 65 KV dielectric strength as per IS 15652 complete in all respects. (For 11 KV) |
| 765 | Supplying and laying of 1000 mm wide x 2 mm thick insulated mat made from highly electrical resistant elastomer of tested quality to withstand 30 KV dielectric strength as per IS 15652 complete in all respects. (For LT Panels) |
| 766 | Supplying and fixing of fire bucket, round bottom made of GI sheet 9 to 11 liters capacity duly painted as per fire brigade design, supported on hanging bracket chained and locaked, initially filled with fine river sand, water as per direction of Engineer Incharge. |
| 767 | Supply and erection of shock restoration chart in glass frame |
| 768 | Supplying and fixing of carbon dioxide fire extinguisher type 4.5 kgs. Capacity (ISI marked IS:2878 and TAC approved) complete with initial charge and wall bracket, alongwith supply of all amterials and labor for proper completion of work.. |
| 769 | Supplying and fixing of first aid box as approved complete with standard kit as prescribed by Indian Red Cross. |
| 770 | Supply and erection of caution notice plate in three languages. |
| 771 | Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S.rod welded / revitted at the top with 10 cm. Dia 5 mm thick G.I.plate inscribed with `cable' world on it , having a cross arm 30 cm. long of the same dia welded at the bottom , in existing trench 45 cm. below ground level . |
| 772 | MV CABLES |
| 773 | Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- |
| 774 | HT Cable Overall size 400sq.mm (3Core) |
| 775 | S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:- |
| 776 | Heat Shrinkable End Termination for cable size 240-400 sq. mm, 3Core (Outdoor Type) |
| 777 | Heat Shrinkable type Straight Through Joint Kit for cable size 240-400 sq. mm, 3Core |
| 778 | Sandwiched Bus ducts |
| 779 | Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Duct for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-66 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos Copper bus bars Complying IS 61439-6 at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required |
| 780 | 4000 A 50kA SC for 1 sec |
| 781 | 800 A 50kA SC for 1 sec |
| 782 | D.G. SETS |
| 783 | Supply, testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-4) fabricated out of CRCA sheet of 14 / 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system , including the cost of suitable sized Cement Concrete foundation as per (as per standards) complete with testing etcas per satisfaction of Engineer in- charge in all respects comprising of the following. |
| 784 | Diesel Engine - |
| 785 | Diesel Engine suitable for driving alternator of below rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for below output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. |
| 786 | Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings : |
| 787 | Start stop switch with key |
| 788 | Water temperature indication |
| 789 | Lubrication oil pressure indication. |
| 790 | Lubrication oil temperature indication. |
| 791 | Battery charging indication |
| 792 | RPM indication |
| 793 | Over speed indication |
| 794 | Low Lube oil trip indication |
| 795 | Engine hours indication |
| 796 | Alternator - |
| 797 | Synchronous Alternator of below capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination as required. |
| 798 | Note : - Alternator should have with all other accessories as per specified in Technical specfications. |
| 799 | Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer. |
| 800 | Power Controller For DG synchronization |
| 801 | Microprocessor based Power command controller (P.C.- 3.3 Jakson or equivalent) suitable for auto / manual synchronization & auto load sharing. |
| 802 | Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required. |
| 803 | Exhaust Silencer - Exhaust manifold with residential silencer. |
| 804 | The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system. |
| 805 | Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH. |
| 806 | Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications. |
| 807 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 808 | Overall size 2.5sq.mm (50/0.25mm), 3Core |
| 809 | Overall size 4.0sq.mm (56/0.3mm), 3Core |
| 810 | Overall size 6.0sq.mm (84/0.3mm), 3Core |
| 811 | Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:- |
| 812 | Copper thimble cable Core size 4 - 6sq.mm |
| 813 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 814 | Brass Gland for Aluminium cable 2/3 Core size 2.5sq.mm |
| 815 | Brass Gland for Aluminium cable 2/3/4 Core size 4sq.mm |
| 816 | Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm |
| 817 | Dismantling, loading, transportation/shifting from Oxygen Plant, Govt. Hospital, Phase-6, S.A.S. Nagar to Proposed Medical College & Hospital Site, Sector-81, S.A.S. Nagar, unloading, re-installation, testing and commissioning of existing 2 Nos. 320 KVA Diesel Generator Sets complete with associated AMF Panels, including all interconnections, cable terminations, earthing connections, alignment, grouting and allied works. The scope shall also include construction of suitable RCC foundations for DG Sets and AMF Panels as per site requirements and manufacturer's recommendations, complete in all respects and as directed by the Engineer-in-Charge. |
| 818 | Servicing (including fuel filter kit-1, lube oil filter-2, water separator-01 with assembling, engine oil-40 ltr., coolant-20 Ltr. Etc.) |
| 819 | S/I/T/C of Lead Acid, 12V, 180Ah Battery with minimum 24F+18P warranty (24 Months Replacement & 18 month on Pro Rata basis), including 02 nos terminal gap 02 nos fastener 02 nos terminal protector, Suitable for generator of capacity 320KVA |
| 820 | Cost of diesel as per current market rates 89.47/Ltr |
| 821 | SUBHEAD - X: EXTERNAL LIGHTING |
| 822 | Street Lighting |
| 823 | GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR: |
| 824 | Supply and erection of Galvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length (Raw material confiming to IS-5986 (FE-510), BSEN-10025S-355J or ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conforming to IS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461-1991 OR ASTM-A123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level as required:- |
| 825 | Galvanized Octagonal Pole Overall Length 7 metre (Sheet thickness 3mm), Top dia.(A/F) 70mm and bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length≥700mm with Base Plate Dimensions 220mm x 220mm x 14mm Thick |
| 826 | GALVANIZED OCTAGONAL POLE BRACKETS: |
| 827 | Supply and erection of bracket for galvanized octagonal pole, the bracket should be fixed on the top of the pole having top outer dia. 70mm to 90mm (A/F) complete in all respect as approved by the Engineer-in-charge at site:- |
| 828 | Single arm bracket 1 metre long for galvanized octagonal pole |
| 829 | Supply and erection of LED IP66 StreetLight 70watt (including LED driver),Pressure Die cast aluminium with efficacy of LED fixture Minimum 120 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by Hon. Tech. Advisor to CM Punjab Letter no ATBP/20/CL Dated 30/11/2017. CCT 3000 K To 6500 K At/2021/GL/1410-1422 dt. 06.05.2021 |
| 830 | TIMER: |
| 831 | S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C- Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in- charge:- |
| 832 | Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C- Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 833 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: |
| 834 | CUBICAL PEDESTAL: |
| 835 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 836 | Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm |
| 837 | XLPE INSULATED ARMOURED CABLES (UNDERGROUND): |
| 838 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- |
| 839 | Overall size 25sq.mm (3½ Core) Armoured (Underground) |
| 840 | Overall size 16sq.mm (4Core) Armoured (Underground) |
| 841 | XLPE INSULATED ARMOURED CABLES (ON SURFACE): |
| 842 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 843 | Overall size 25sq.mm (3½ Core) Armoured (On-Surface) |
| 844 | Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 845 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 846 | Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm |
| 847 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm |
| 848 | G.I. EARTHING: |
| 849 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 850 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 851 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 852 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 853 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): |
| 854 | Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. |
| 855 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) |
| 856 | Additional length G.I. wire 7/14 S.W.G. (7/2.18mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 857 | Post Top Light |
| 858 | GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR: |
| 859 | Supply and erection of Galvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length (Raw material confiming to IS-5986 (FE-510), BSEN-10025S-355J or ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conforming to IS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461-1991 OR ASTM-A123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level as required:- |
| 860 | Galvanized Octagonal Pole Overall Length 4 metre, Top dia.(A/F) 70mm & Bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 900mm, 4Nos. Foundation Bolts size 16mm dia., Length≥450mm with Base Plate Dimensions 200mm x 200mm x 12mm Thick |
| 861 | Supply and erection of LED Post top 40/45 watt with (CCT 3000K/4000K/5700K)Opal Diffuser Supply Voltage 140-270Volts AC supply. 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:-06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab |
| 862 | S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- |
| 863 | Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C- Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 864 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- |
| 865 | Overall size 25sq.mm (3½ Core) Armoured (Underground) |
| 866 | Overall size 16sq.mm (4Core) Armoured (Underground) |
| 867 | XLPE INSULATED ARMOURED CABLES (ON SURFACE): |
| 868 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 869 | Overall size 25sq.mm (3½ Core) Armoured (On-Surface) |
| 870 | Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 871 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 872 | Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm |
| 873 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm |
| 874 | G.I. EARTHING: |
| 875 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 876 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 877 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 878 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 879 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): |
| 880 | Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- |
| 881 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) |
| 882 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: |
| 883 | CUBICAL PEDESTAL: |
| 884 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 885 | Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm |
| 886 | SUBHEAD - XII :SOLAR POWER GENERATION SYSTEM |
| 887 | Supply, Installation, testing & commissioning of Grid Interactive PV System Solar Power Plant (i.e. connected to utility grid) of Minimum 20KWPp including required quantities of SPV modules ( high Power density Perc bifacial Single Module of capacity 500W+formed into arrays, their mounting arrangement, Power Conditioning units (i.e. string solar inverter) required DC & AC distribution panel with surge protection units cabling from terrace to Main distribution board through cable tray to By-Directional Energy meter required Earthing ( i.e. 2 Nos GI strip earthing for GI structure, 2 Nos GI earthing to strip inverter, AC & DC Distribution system[ ESI Stroke marter ( As per NFC 37 502 standard with suitable radius of protection) & 3 nos chemical earthing with copper bounded rods along with high rise GPSP structure ( Rated wind speed 170 Kgh) including mounting height upto 8 feet complete with transportation, fabrication labour & check work.Features:-1. Solar PV Module Warranty 25 years certified under IS/IEC 617301 & IS/ IEC 61301 & IS /IEC 142862. Power conditioning unit[ string Solar Inverter]& certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61020-6-2, EN 61000-6-3, IEC 61683, EN 30510, IEC 60068-2-1, 2, 34, a2, EN 605293. Structure 25 years service life with AMC & certified under IS 2062 20114. Complete plant insurance for the period of 5 years( Excluding theft of material)5. Annual Maintenance contract for the period of 5 yearsa. The work will get done from approved 1.1 mter/ Minsitry of New and Renewable Energy)/PEDA[ Punjab Energy Development Agency, Contractor PWD inlisted contractor subject to the condition that he will get work done by PEDA/MNRE aprroved contractor The capacity of Solar power plant may increase or decrease on availability of site can also be totally removed from executive andThe Rate are inclusive of all taxes including GST & Bidrectional meter listing charges, PSPCL charges, unidirectional |
| 888 | SUBHEAD - XIII : Lift |
| 889 | Girls Hostel |
| 890 | Supply, installation, testing and commissioning of 1 No. lift of 13 passengers Machine room less.Type and Capacity: Approximately 884 Kg, 13 Persons Speed: 1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately meter 8 Floors, 8 Stops 8 Openings. 8 Levels (All on the same side) Serving:Hoist way Required: 2450 mm (Wide) x1850mm Clear dimensions Headroom Height (HR): 4000 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car dimension: 1600 mm W x 1400 mm D x 2200 mm H (or as per company standards to meet passenger capacity) Car door size: 900mm x 2100 mm Car Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof/Honeycomb/ hairline). Car Entrance: Center Opening Automatic Doors of Stainless steel finish panel in Scratch Resistance/ Vandal proof/Hair line with a clear opening of 900mm (wide) x 2100mm (high) Fire Retardent Door operation: Center Opening Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix /Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH, Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floorlevel Std. Govt. features.Other Features:1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3.Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance/exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure 28. the provision of the mirror on the wall of the Mft Casr opposite the lift door donot extend belw 900 mm from the left floor to avoid confusing people with impaired sigh. 29. The emergency commiunication system should be coupled with an induction loop system, with telephone unit, where provided should have an inbuilt inductive coupler to assist persons. 30 The floor of thge ccar should be slip resistant and have a similar function quality to the floor of the lift landing to decrease the risk of stumbling 31. the use of visually acoustically reflective wall surface should be minimised within the lift car as visual reflection can caouse discomfort and affect the visual activity of the people with impairments. |
| 891 | Landing Entrance protection: Vertical Biparting MS Painted Mnnual Door painted Black. Lift controller based on microprocessor/ PLC with VVVF Drive with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/ control card & allied accessories. Type of Control System : External extended push buttons with or without attendentLift Machine with Geared type PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on head room/ shaft walls complete with suspension wire ropes/belts of adequate size & strength. |
| 892 | Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work• Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. |
| 893 | General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector (Lifts) with submission to the Engineer In Charge. The technical specification of Lift duty motor, control panel, brakes, guide rails, and guide shoes, lift car frame, car, counter weight and suspension, lift safety gear and governor, buffer, lift doors, locking device and contacts, lift wire rope of lifts shall be as per actual requirement of the job. |
| 894 | With required provision for persons with Disabilities and all fire norms. |
| 895 | Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule. |
| 896 | Landing Entrance protection: Vertical Biparting MS Painted Mnnual Door painted Black. Lift controller based on microprocessor/ PLC with VVVF Drive with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/ control card & allied accessories. Type of Control System : External extended push buttons with or without attendentLift Machine with Geared type PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on head room/ shaft walls complete with suspension wire ropes/belts of adequate size & strength. |
| 897 | Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work• Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. |
| 898 | General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector (Lifts) with submission to the Engineer In Charge. The technical specification of Lift duty motor, control panel, brakes, guide rails, and guide shoes, lift car frame, car, counter weight and suspension, lift safety gear and governor, buffer, lift doors, locking device and contacts, lift wire rope of lifts shall be as per actual requirement of the job. |
| 899 | With required provision for persons with Disabilities and all fire norms. |
| 900 | Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule. |
| 901 | Boys Hostel |
| 902 | Supply, installation, testing and commissioning of 1 No, lift of 16 passengers Machine room less.Type and Capacity: Approximately 1020 Kg. 15 Persons Speed: 1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately meter Floors, 6 Stops 6 Openings, 6 Levels (All on the same side) Serving: 6Hoist way Required: 2500 mm (Wide) x 2750mm Clear dimensions Headroom Height (HR): 4200 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car dimension: 1000 mm W x 2400 mm D x 2300 mm H (or as per company standards to meet passenger capacity) Car door size: 900mm x 2100 mm Car Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof/Honeycomb/ hairline). Car Entrance: Center Opening Automatic Doors of Stainless steel finish panel in Scratch Resistance/Vandal proof/Hair line with a clear opening of 900mm (wide) x 2100mm (high) Fire Retardent Door operation: Center Opening Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix /Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH, Side RH & Rear) Call Button Height. Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features.Other Features:1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3.Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel iterns, door frames sill angle's, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure 28. the provision of the mirror on the wall of the Mft Casr opposite the lift door donot extend belw 900 mm from the left floor to avoid confusing people with impaired sigh. 29. The emergency commiunication system should be coupled with an induction loop system, with telephone unit, where provided should have an inbuilt inductive coupler to assist persons. 30 The floor of thge ccar should be slip resistant and have a similar function quality to the floor of the lift landing to decrease the risk of stumbling 31. the use of visually acoustically reflective wall surface should be minimised within the lift car as visual reflection can caouse discomfort and affect the visual activity of the people with impairments. |
| 903 | Landing Entrance protection: Vertical Biparting MS Painted Mnnual Door painted Black. Lift controller based on microprocessor/ PLC with VVVF Drive with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/ control card & allied accessories. Type of Control System : External extended push buttons with or without attendentLift Machine with Geared type PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on head room/ shaft walls complete with suspension wire ropes/belts of adequate size & strength. |
| 904 | Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work• Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. |
| 905 | General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector (Lifts) with submission to the Engineer In Charge. The technical specification of Lift duty motor, control panel, brakes, guide rails, and guide shoes, lift car frame, car, counter weight and suspension, lift safety gear and governor, buffer, lift doors, locking device and contacts, lift wire rope of lifts shall be as per actual requirement of the job. |
| 906 | With required provision for persons with Disabilities and all fire norms. |
| 907 | Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule. |
| 908 | Supply, installation, testing and commissioning of 1 No, lift of 16 passengers Machine room less.Type and Capacity: Approximately 1020 Kg. 15 Persons Speed: 1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately meter Floors, 6 Stops 6 Openings, 6 Levels (All on the same side) Serving: 6Hoist way Required: 2500 mm (Wide) x 2750mm Clear dimensions Headroom Height (HR): 4200 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car dimension: 1000 mm W x 2400 mm D x 2300 mm H (or as per company standards to meet passenger capacity) Car door size: 900mm x 2100 mm Car Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof/Honeycomb/ hairline). Car Entrance: Center Opening Automatic Doors of Stainless steel finish panel in Scratch Resistance/Vandal proof/Hair line with a clear opening of 900mm (wide) x 2100mm (high) Fire Retardent Door operation: Center Opening Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix /Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH, Side RH & Rear) Call Button Height. Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features.Other Features:1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3.Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel iterns, door frames sill angle's, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure 28. the provision of the mirror on the wall of the Mft Casr opposite the lift door donot extend belw 900 mm from the left floor to avoid confusing people with impaired sigh. 29. The emergency commiunication system should be coupled with an induction loop system, with telephone unit, where provided should have an inbuilt inductive coupler to assist persons. 30 The floor of thge ccar should be slip resistant and have a similar function quality to the floor of the lift landing to decrease the risk of stumbling 31. the use of visually acoustically reflective wall surface should be minimised within the lift car as visual reflection can caouse discomfort and affect the visual activity of the people with impairments. |
| 909 | Landing Entrance protection: Vertical Biparting MS Painted Mnnual Door painted Black. Lift controller based on microprocessor/ PLC with VVVF Drive with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/ control card & allied accessories. Type of Control System : External extended push buttons with or without attendentLift Machine with Geared type PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on head room/ shaft walls complete with suspension wire ropes/belts of adequate size & strength. |
| 910 | Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work• Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. |
| 911 | General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector (Lifts) with submission to the Engineer In Charge. The technical specification of Lift duty motor, control panel, brakes, guide rails, and guide shoes, lift car frame, car, counter weight and suspension, lift safety gear and governor, buffer, lift doors, locking device and contacts, lift wire rope of lifts shall be as per actual requirement of the job. |
| 912 | With required provision for persons with Disabilities and all fire norms. |
| 913 | Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule. |
| 914 | SUBHEAD - XIV: INTELLIGENT FIRE ALARM & PA SYSTEM |
| 915 | Supply, installation, testing & Commissioning of Microprocessor based Two Top True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event, 1000 alarm log history events, Qwerty/ Touch Screen keypad for operation. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 250 analog addressable devices (Devices and detectors), Loop Cards Class A Wiring with min. supporting cable length Up to 1.2 Km UL & FM. The panel shall work in degrade mode in case of CPU failure, Products not having this feature will offer Redundant CPU. Four access levels, flash EPROM, Panel Shall include 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall support with Seamless integration with Analog/Digital Integrated analog/Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 5 Telephones in conference in multiple FFT Risers. The panel shall be expandable upto Min. 10 loop, UL & FM approved. Panel shall have provision for Modbus/ Bacnet over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable for remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th. This also include2 No. loop card |
| 916 | Supply, installation, testing & Commissioning of Paging Microphone compatible with Emergency evacuation Control Panel UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 917 | Supply, installation, testing & Commissioning of Addressable photo-Thermal multi cntena Detector and base with sensitivity range as per NFPA 72. The intelligent detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing Addressing shall be with user friendly rotaryf Electronic decimal switches. Designed to meet UL & FM Approved The solution should be from single OEM. |
| 918 | Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site UL & FM Approved |
| 919 | Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA 3m for Audible annunciation and Min 110 od flashintg at 1 Hz for visual indication. UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 920 | Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes! Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device Addressing shall be with user friendly rotary / Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 921 | Supply, installation, testing & Commissioning of Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device Addressing shall be with user friendly rotary! Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 922 | Supply, installation, testing & Commissioning of Isolator Module for Isolating short/dewired/loose circuits with automatic resetting arrangement isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device.UL & FM Approved Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The solution should be from single OEM. |
| 923 | Supply, installation, testing & Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary/ Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 924 | Supply, installation, lesting & Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 925 | Supply, installation, testing & Commissioning of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center,complete in all respects as approved and desired by the Engineer in-charge at site. |
| 926 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 927 | Supply, installation, testing & Commissioning of Exit LED M ST LED based exit sign with dimming function. Reading distance, exit sign Two-sided 25m. Voltage 220-240VAC/50-60Hz, Power consumption 3.3W/3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection deep discharge protection, Charging Time 16 hours. Battery back-up time 1 hour/3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60596-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3. Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540/742 gr, Colour Anodized aluminum/black plastic. Materials Aluminum, Acrylic Plate, Mounting method Celling, wat bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40-datproof luminaire Reading distance upto 25 meters. High lumen output-th-180m/3h = 110km/8h = 40lm Technical lifetime of LED > 100 000 hours 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code complete in all respects as approved and desired by the Engineer in-charge at site. |
| 928 | PUBLIC ADDRESS SYSTEM |
| 929 | Supply, installation, testing & Commissioning of 2W Multi-Tap (0.25W,0.5W,1W, 2W), Ceiling/Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70, 7Vrms UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 930 | Supply, installation, testing & Commissioning of Back Box for 2W Multi-Tap (0.25W,0.5W,1W, 2W). Ceiling Wall Mount Speakers UL Listed as complete in alt respects as approved and desired by the Engineer in-charge at site |
| 931 | Supply, installation, testing & Commissioning of Voice Command Controlling Board combines the capabilities of a powerful digital audio processor, an eventdriven audio message generator, and a router. The VC has two wire digital audio ports to connect to wire DAL segments. The VC may be networked Programmable from NUP port. Up to 32 minutes of standard quality or 4 minutes of high quality digital audio storage of user-selected/created messages and tones. Supports twisted-pair wire media. Supports single-and multi-mode fiber-optic media when used with fiber option modules. 4-channel analog audio supported. The VC Should be Compatible with Auxiliary input for line level, 1.0 VRMS, or 1.41 Vp-p low level audio. Selectable AGC, user control of audio level, and audio supervision are supported UL Listed. S635. ULC Listed: 8635.FM Approved. The solution should be from single OEM |
| 932 | Supply, installation, testing & Commissioning of Digital Audio Amplifier with cabinet & Amp power supply. Amplifier shall be capable of N NIN 1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of Min 75-95 W (It may be 1 unit or Combination of Multiple units to achieve the Requirement) at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall (be Wall Panel Mounted), including isolaton transformer and chasis. Failure of Fire Panel CPU shall not result in failure of Amplifier operation. Amplifiers shall be distributed across the bulding/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers shall provide back up of minimum 5 hours using secondary power source(battery power/UPS power) complete in all respects as approved and desired by the Engineer in-charge at site. |
| 933 | Cabling and Wiring |
| 934 | Supply and erection of fire survival cable for fire alarm & PA system with annealed stranded copper conductor, fire resistant mica tape wrapped (at 950°C for 180 minutes), XLPE insulated, LSHZ (low smoke & zero halogen) bedding, LSZH (low smoke & zero halogen) red outer sheath, galvanized steel wire armour, 600/1000 volts grade, Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ, Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) left bare in pipe or casing or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-Fire Survival cable 2Core x 1.5 sq.mm |
| 935 | speaker cable Single pair, 2-core, 1.5 sqmm |
| 936 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 937 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 938 | Heavy Gauge PVC Conduit Pipe 20mm dia. (Flushed) |
| 939 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 940 | SUBHEAD - XV: CCTV SYSTEM |
| 941 | Supply & erection of IP Bullet/Dome Vari Focal CAMERA 5MP IP Camera STQC Approved with Audio Input Support and following features Resolution - 5 MP (2592 x 1944), Sensor Type and Size-1/2.8\\" CMOS 5MP Active Pixel Progressive Scan, Back Illuminated Image sensor, Minimum Illumination Color - 0.01 Lux @F1.2 (AGC ON), Monochrome - 0 Lux, Focal Length 2.8mm – 12mm Focus Range - 0.3m to infinity, Field of View (FOV) HFOV – 106 - 32°,VFOV- 73-23,DFOV 142-39, Focus-Automatic focus Aperture (F#) F 1.6 - F 2.8,Iris Type Motorized varifocal, IR Range Up to 50m, IR Led Wavelength 850nm, IR Switching Auto/ Manual , Audio IN 1,Audio OUT 1,Two-way Audio Supported, Audio Compression G.726 and G.711μAlarm In Yes, Alarm Out Yes, SD Card Up to 512GB, Camera Adjustment Angle Pan: 0° to 360° Tilt: 0° to 90° Rotate: 0° to 360°,No of Stream Profiles 4, Stream Profiles- Profile 1: Mainstream - 2592*1944@ 30fps (H.265/H.264), Profile 2: Sub stream - D1@30fps (H.265/ H.264), Profile 3: MJPEG - 2048*1536@8fps (MJPEG) or D1/VGA@15fps(H.264/H.265) Profile 4:1920*1080@30fps (H.265/H.264/MJPEG) Available Resolutions 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, VGA, 2CIF, CIF, Max Resolution 2592 x 1944, Bitrate 128 kbps-16Mbps, Bitrate Type CBR, VBR, Video Compression H.265, H.264, MJPEG, Frame Rate 1-30fps, Shutter Speed 1/15s -1/100000s,Adaptive Streaming Yes, ONVIF Profiles S, G, and T, Edge Recording Yes, Alarm Recording Pre and Post, Motion Recording Yes, Time Triggered Yes, Video Parameters Snapshot, Region of Interest (ROI), BLC, HLC, Day/Night Settings, Privacy Masks 8, WDR True WDR (120dB), SNR >70dBImage Enhancement Saturation/ Contrast/ Sharpness/Brightness/Auto Exposure/HVS- Forensics/ Smart IR DNR 2D &3D |
| 942 | Video Analytics, Motion/No Motion Detection, Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion, Audio Exception, IP Conflict Yes, Network Disconnect Yes, Storage Full Yes, Upload Image SD, NAS, SFTP, Upload Clip SD, NAS, SFTP Notifications E-mail, SMS, TCP, Supported protocols, TCP/IP, UDP, HTTP, HTTPS, DHCP, DNS, Dyn DNS, DDNS, RTP, RTCP, RTSP, PPPOE, SMTP, NTP, SNMP, FTP, TLS/SSL, SFTP, ICMP, IGMPv2 & v3, ARP, 802.1x, IPv4, IPv6, QoS Layer 3, DSCP, CIFS, SSH, UPnP, Bonjour, Web Viewer Supported in IE 8.0-11.0, Firefox 15.0-47.0, Chrome 20.0-54.0, Browser IE, Chrome, Mozilla, CYBER SECURITY as per ISO/IEC 27402-Secure boot Yes, Signed firmware Yes, Data Encryption All data, including sensitive data, is encrypted with AES 256 and RSA 2048, IP Address Filtering Yes, HTTPs Streaming Yes, using TLS 1.2, Edge Data Encryption Yes, Network Authentication Yes,802.1x Network authentication, Secure Firmware Upgrade Yes, Anti-roll back firmware Yes, Web login Password protection Yes, Unused debug interface protection Yes, Power Supply 12V (DC); 802.3af (PoE), Power Consumption Approximately 7W, Operating Humidity Less than 95% RH (non-condensing), Operating Temperature -30°C to 60°C,Storage NAS, SD Card, BIS, CE, IP67, FCC Part-15 Subpart – B, ONVIF S, G & T, IK10, UL, NEMA 4X**,- complete in all respect as desired by the engineer in charge at site. |
| 943 | SUPPLY & ERECTION OF 64 Channel IP INPUT 12MP NVR 4K with 4 SATA having following features:- Up to 64 Channel Input, 4 Sata Interfaces, Up To 12TB each, H.265+/H.265/H.264 Video Formats, 1 HDMI Port , USB2.0*1, USB2.0*2 Support,2×RJ45 Self-adaptive 10/100/1000 Mbps Network Interfaces, Supports live view, storage and playback of the connected camera at up to 12MP resolution, Connectable to the Third Party Network Cameras, Incoming Bandwidth -500M, Outgoing Bandwidth-500M, Recording Resolution-12 MP/8 MP/5 MP/4 MP/3 MP/1080p/720p, Recording Compression, Audio: G.711a,G.711u, Video : H.264/H.265, H.264+/H.265+, Speed -12MP:30fps 8MP:120fps 4MP:240fps 2MP:480fps, Playback- 1080P:480fps Max 16CH, WEB -IE10/11, Safari V12.1 above, Firefox V.52 above, Google chrome V.57 above, Edge V.79 above, Protocols-TCP/IP, DHCP, IPv4, IPv6, DNS, DDNS, NTP, RTSP, SADP, SMTP, SNMP, UPnP, HTTP, HTTPS, API -Onvif (profile S/G/T HDMI -1(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080, 2560*1440(2K), 3840*2160(4K)) 0 /EDID) Async out, Ethernet-2 RJ45 100/1000 Base-T USB USB2.0*1(front), USB 2.0 *1 USB 2.0 *1 (rear), Audio-1 in / 1 out, E-sata-1 ,HDD 4, each up to 12TB, RS 485-1, Alarm Input/out -16 in /1 out, OSD LanguageEnglish, Input Voltage/ Current 12V/5A, Power consumption (excluding hard disk) -8WOperating Temperature/Humidity-Temperature :-10°C~+50°C (14°F ~ 122°F) Humidity : Less than 90%RH complete in all respect as desired by the engineer in charge at site. |
| 944 | SUPPLY & ERECTION of 6TB/6000GB Audio Video HDD 3.5 Inches Connector SATA, Interface SATA, Operating Temperature 0°C to 65°C, Transfer Rate minimum 160MB/s, Recording Technology – CMR, Certifications BSMI, ICES-003/NMB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL for NVR recording and playback complete in all respect as desired by the engineer in charge at site |
| 945 | SUPPLY of computer of custom Built i7 13th Gen. or above Intel Core Processor/16GB DDR4 RAM/512GB SSD/4GB Dedicated Graphic Card/OEM Windows10 /500 Watts SMPS Power Supply with 32 inches HDMI Monitor, Keyboard and Mouse, 5 Mtr HDMI Cable for maintenance of IP Cameras complete in all respect as per site Requirement |
| 946 | Supply & erection of Smart 55” LED Commercial Panel /Regular with 2 HDMI Port, TV Input, 3 Years Warranty, 2 HDMI Port, TV Input, 3 Years Warranty, Resolution 4K, Brightness 300 cd/m2 Support 4K Ultra HD 20 Watt 2.0 Audio Output Web Browser Soft AP, WiFi (bandwidth) Screen Share (Miracast) Samsung TV Plus App USB Cloning, 2 No. Of HDMI Port 2 no USB Port complete in all respect as desired by the engineer in charge at site. Make Samsung/LG/Panasonic |
| 947 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-CAT 6 LAN cable |
| 948 | SITC of 12U (W 600mm/with minimum D 600mm) wall mount rack with front glass door and side panels with lock & key (load bearing capacity of 60Kgs), AC main Channel 06 points 5 Amp (PDU) with Mounting Hardware (Pack of 10) etc. all complete |
| 949 | SITC of 15U (W 600mm/with minimum D 600mm) Close rack 19\\" Wall mount, Front Door S12C 19\\" / 15U, AC Distribution Box + H/W (5 Points of 5/15 AMP sockets - (Horizontal), 19\\" 1U Cable Manager PVC with duct fingers x 5, Fan housing unit 2 Fan POSN, Fans 90 CFM 230 VAC, Mounting Hardware (Pack of 10) x 5 as per specification etc. all complete |
| 950 | SITC of 6 Core single Mode Outdoor Fiber Optic Cable, High Link Fiber Optic, Armoured, Multi loose Tube, Outdoor Cable, Gel filled, CSM FRP, Single Sheath Black HDPE, OM4, ROHS Certified with OTDR Scanning for OFC per core connectitvity and uplink test for Point to Point with other raleted testing and services (as per actual) as per specification etc. all complete. |
| 951 | SITC of 19” Rack Mount, 24 Port Multi Mode LIU Panel, preloaded with a pigtails, Splice tray & necessary fiber management accessories etc all complete. as per specification etc. all complete |
| 952 | SITC of SC MM Pigtail (1.0 Meter), LSZH jacket, meets IEC-60332 (LSZH) flame rating for standard safety compliant. as per specification etc. all complete |
| 953 | SITC of SC-LC MM Fiber Patch Cords ( 3 Mtr), LSZH jacket, meets IEC-60332-1 (LSZH) flame rating for standard safety compliant as per specification etc. all complete |
| 954 | Supply, Installation,Testing & Commissioning of of Access Switch 24 Port POE+Access Switches with switching capacity of 240 Gbps, forwarding performance 190Mbps, having 24x 10/100/1000 BASE-TPoE-plus (RJ45) with minimum PoE budget of 370W with redundant power supply provision and 4x10 GSFP+ uplink ports, should have support for 8 switch Stacking with stacking cable with bandwidth of minimum120 Gbps.Should support min 2GB internal DRAM, 2GB internal Flash memory, 32 KMAC address, 4k Multi cast Routes,Should have static Routing from day1 and upgradable to support OSPF and VRRP with 5 year on site support(for CCTV) |
| 955 | SUBHEAD - XVIII: LAN SYSTEM (DATA & VOICE) |
| 956 | SITC of High Speed 10Gigabit Ethernet U-UTP 500 MHz Class EA / Category 6A LSZH Cable is produced using HDPE Insulated 8 x 23 AWG Solid Bare Copper Conductors, supports 10/100/1000Base-T, 155Mbps ATM, IEEE 802.3an (10GBase-T) Standard, Channel Performance verified by ETL, UL Verified, RoHS Certified in existing concealed/surface conduits / Raceways complete 305 Mtr. Roll, including Penta Scanning for per Copper connectitvity with other raleted testing and services (as per actual) as per specification etc. all complete |
| 957 | SITC of 1 Meter 24 AWG LSZH Category 6A U / UTP Patch Cord, Complies to ANSI/TIA-568.2-D, Stranded Bare Copper, High grade 50μm gold Plated RJ45 connecters, Channel Performance verified by ETL, UL Verified, RoHS Certified Standard as per specification etc. all complete |
| 958 | SITC of 2 Meter 24 AWG LSZH Category 6A U / UTP Patch Cord, Complies to ANSI/TIA-568.2-D, Stranded Bare Copper, High grade 50μm gold Plated RJ45 connecters, Channel Performance verified by ETL, UL Verified, RoHS Certified Standard as per specification etc. all complete |
| 959 | SITC of Category 6A UTP Keystone Jack / Outlet, 180 degree Termination, Unshielded, Tool-less, Complies to ANSI/TIA 568.2-D, IEC/ISO 11801 & IEC 60603-7-41, Plug Insertion Life ≥ 750 Cycles as per specification etc. all complete |
| 960 | SITC of Single Face Plate Shuttered, Provision for accepting any Keystone Style RJ45 Outlets, Capable of providing RJ45/ RJ11 type, Label Holders with Plastic covers, Built-in Dust Covers with Back boex as per specification etc. all complete |
| 961 | SITC of Dual Face Plate Shuttered, Provision for accepting any Keystone Style RJ45 Outlets, Capable of providing RJ45/ RJ11 type, Label Holders with Plastic covers, Built-in Dust Covers with Back boex as per specification etc. all complete |
| 962 | SITC of Quad Face Plate Shuttered, Provision for accepting any Keystone Style RJ45 Outlets, Capable of providing RJ45/ RJ11 type, Label Holders with Plastic covers, Built-in Dust Covers with Back boex as per specification etc. all complete |
| 963 | SITC of Rack Mountable Patch Panel, 24 Cat 6A Loaded Ports, Copper Patch Panel, Straight, Unshielded, Durability (IDC Life) 200 termination cycles with in Built Wire Manager, Grounding Bolt included as per specification etc. all complete |
| 964 | SITC of Rack Mountable Patch Panel, 48 Cat 6A Loaded Ports, Copper Patch Panel, Straight, Unshielded, Durability (IDC Life) 200 termination cycles with in Built Wire Manager, Grounding Bolt included as per specification etc. all complete |
| 965 | SITC of 6 Core Single Mode Outdoor Fiber Optic Cable, High Link Fiber Optic, Armoured, Multi loose Tube, Outdoor Cable, Gel filled, CSM FRP, Single Sheath Black HDPE, OM3, ROHS Certified with OTDR Scanning for OFC per core connectitvity and uplink test for Point to Point with other raleted testing and services (as per actual) as per specification etc. all complete |
| 966 | SITC of 19” Rack Mount, 6 Port Multi Mode LIU Panel, preloaded with a pigtails, Splice tray & necessary fiber management accessories etc all complete. as per specification etc. all complete |
| 967 | SITC of SC MM Pigtail (1.0 Meter), LSZH jacket, meets IEC-60332 (LSZH) flame rating for standard safety compliant. as per specification etc. all complete |
| 968 | SITC of SC-LC MM Fiber Patch Cords ( 3 Mtr), LSZH jacket, meets IEC-60332-1 (LSZH) flame rating for standard safety compliant as per specification etc. all complete |
| 969 | SITC of 15U (W 600mm / D 600mm) Close rack 19\\" Wall mount, Front Door S12C 19\\" / 15U, AC Distribution Box + H/W (5 Points of 5/15 AMP sockets - (Horizontal), 19\\" 1U Cable Manager PVC with duct fingers x 5, Fan housing unit 2 Fan POSN, Fans 90 CFM 230 VAC, Mounting Hardware (Pack of 10) x 5 as per specification etc. all complete |
| 970 | SITC of 24U (W 600mm/ D 600mm) Floor mount with front glass door, back steel door and side panels, Accessories of rack With lock & key for all side panels & door, Fan Housing Unit with 4 fans, Cable manager 4U Horizontal x 8, Cantilever tray, AC main Channel 06 points 5 Amp (PDU) ,Earthing Kit, Mounting Hardware (Pack of 10) as per specification etc. all complete |
| 971 | SITC of Indoor Wireless Access Point with 802.11ax (Wi-Fi 6) technology, Dual radios 2.4 GHz / 5 GHz band, Multi-user multiple input, multiple output (MU-MIMO), enhanced security with WPA3, Fully backward compatible with existing 802.11 a/b/g/n/ac deployments etc. all complete |
| 972 | SITC of Wireless Controller for Wireless APs (min 50 nos) and Licenses with NMS for proposed devices from same OEM, Authentication and Encryption For this “large deployment” scenario, the WLAN solution shall include a built-in RADIUS server for 802.1x and MAC authentication that shall not be proposed as a separate product Fibre transreciever module etc. all complete |
| 973 | SITC of SIP User Linceses per User as per the given Specification etc. all complete |
| 974 | SITC of High End Desktop Phones, 3.5’’ colour screen, 2x5 programmable keys with blue LED, super-wideband, corded handset, 2 USB-C ports, Extensive connectivity: USB, WLAN, Bluetooth, IP, hybrid digital/IP as per the given Specification etc. all complete |
| 975 | SITC of Medium End Phone: Hybrid Digital/IP, 2.8” backlit screen, 2x3 programmable keys with LED, USB-A and USB-C port as per the given Specification etc. all complete |
| 976 | SITC of Low End Desktop Phone: Entry-level business phone, standard SIP protocol, 2.3 inches graphical black/white LCD Display, 2 SIP accounts as per the given Specification etc. all complete |
| 977 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6A with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-CAT 6 LAN cable |
| 978 | SITC of 12U (W 600mm/ D 600mm) wall mount rack with front glass door and side panels with lock & key (load bearing capacity of 60Kgs), AC main Channel 06 points 5 Amp (PDU) with Mounting Hardware (Pack of 10) etc. all complete |
| 979 | SITC of 15U (W 600mm / D 600mm) Close rack 19\\" Wall mount, Front Door S12C 19\\" / 15U, AC Distribution Box + H/W (5 Points of 5/15 AMP sockets - (Horizontal), 19\\" 1U Cable Manager PVC with duct fingers x 5, Fan housing unit 2 Fan POSN, Fans 90 CFM 230 VAC, Mounting Hardware (Pack of 10) x 5 as per specification etc. all complete |
| 980 | SITC of 6 Core single Mode Outdoor Fiber Optic Cable, High Link Fiber Optic, Armoured, Multi loose Tube, Outdoor Cable, Gel filled, CSM FRP, Single Sheath Black HDPE, OM4, ROHS Certified with OTDR Scanning for OFC per core connectitvity and uplink test for Point to Point with other raleted testing and services (as per actual) as per specification etc. all complete |
| 981 | SITC of 19” Rack Mount, 6 Port Multi Mode LIU Panel, preloaded with a pigtails, Splice tray & necessary fiber management accessories etc all complete. as per specification etc. all complete |
| 982 | SITC of 19” Rack Mount, 24 Port Multi Mode LIU Panel, preloaded with a pigtails, Splice tray & necessary fiber management accessories etc all complete. as per specification etc. all complete |
| 983 | SITC of SC MM Pigtail (1.0 Meter), LSZH jacket, meets IEC-60332 (LSZH) flame rating for standard safety compliant. as per specification etc. all complete |
| 984 | SITC of SC-LC MM Fiber Patch Cords ( 3 Mtr), LSZH jacket, meets IEC-60332-1 (LSZH) flame rating for standard safety compliant as per specification etc. all complete |
| 985 | SITC of Rack Mountable Layer 2 Distribution Network Switch (for Wi Fi and IP Telephone) with POE+ with Min 24 X 10/100/1000 Base-T POE ports with 2 X 1G and 2 X 1/10G (Min) SFP+ ports upgradable to 4 x 10G SFP+ ports with min POE budget of 380 W or better with Fibre transreciever module etc. all complete |
| 986 | SITC of Rack Mountable Layer 2 Distribution Network Switch with (for Wi Fi and IP Telephone) Min 8 X 10/100/1000 Base-T POE+ ports and 4 X 1 (Min) SFP ports with min POE budget of 240 W or better with support for min 2 switch in virtual stack. with Fibre transreciever module etc. all complete |
| 987 | SUBHEAD - UPS |
| 988 | Online UPS- Input supply: Three Phase, Outputsupply: Three Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additionalprotection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supplyAC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. Thesystem shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: |
| 989 | Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging,overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc |
| 990 | 60 KVA |
| 991 | Public Health work |
| 992 | GIRLS HOSTELSANITARY INSTALLATIONS & C.P FITTINGS |
| 993 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect |
| 994 | Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 995 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect ii Size 550 mm x 400 mm x 815 mm |
| 996 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.Vitreous chinaware standard white pedestal for wash hand basin. |
| 997 | Providing and fixing P.V.C Waste PipeCollapsiable 32mm complete in all respect |
| 998 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (asrequired by the Engineer-in- Charge)Size 600mmx450mm |
| 999 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.Double bowl Sink without drain board Overall size 1114 x 490 mm with bowl size 460x385x200mm including waste coupling |
| 1000 | Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.Vertical Type40 litre capacity water heater |
| 1001 | Providing & placing in position on terrace (at allfloor levels) HDPE water storage tanks ofapproved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes forinlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks |
| 1002 | Providing & fixing in position PVC flexible tubeconnection of approved make (to the approval of Engineer-in-charge ) complete in all respectPVC tube connection of size 15 mm x 450 mm with PTMT nut |
| 1003 | Providing and fixing Stainless steel healthfaucet complete in all respect. |
| 1004 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P. brass Bib cock with Wall flange |
| 1005 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P brass Sink mixer with swinging spout.(wall mounted) |
| 1006 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P.brass 15mm Angular stop cock with Wall flange |
| 1007 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P. brass 3-Hole Basin Mixer Without Popup Waste System |
| 1008 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P. Brass Wall mixer with Non telephonic shower arrangement. |
| 1009 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P. brass overhead shower Φ180mm round shape single flow with shower arm with 20mm i/d Inlet and 300mm long round shape with 900 bend with flange. |
| 1010 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-incharge) complete in all respect. |
| 1011 | C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal. (Outer +Inner Body) |
| 1012 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P. brass toilet roll holder with flap |
| 1013 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 1014 | 15mm i/d Brass Ball valves |
| 1015 | 20mm i/d Brass Ball valves |
| 1016 | 25mm i/d Brass Ball valves |
| 1017 | 32mm i/d Brass Ball valves |
| 1018 | ABS Plastic Body Hand Dryer ABS Body Suitable design. 100% unbreakable ABS Body. Voltage: 220 V/50 Hz Rated Power: 2000 Watt Current: 9.2 A Blowing Volume: 900 M/minute. Blowing Rate: 25 m/s Dimension: 240x240x230 mm Drying time: 10 seconds RPM: 3000 revolutions/min Noise: 40 Db Sensing Range: 123 cm Hot Temperature: 30-50oC Continuous work Time: 60 Sec Temperature of wind: 40-54oc |
| 1019 | Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof |
| 1020 | Cutting holes upto 23cm square for pipes in flooring and roofs of bricks, tiles with lime concrete or cement concrete and making good the same & finishing according to existing finish where required. (c) Through floor or roof 15.00cm thick |
| 1021 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P. brass soap dish holder with glass dish |
| 1022 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 1023 | Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge) fixed in with rawl plugs and C.P brass screws complete in all respect.C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm |
| 1024 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge)with various fixtures complete in all respect. C P Brass extension piece, 25mm longto 50mm long |
| 1025 | C.P. brass towel rack 600mm long with lower hangers |
| 1026 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P. brass towel rail 600 mm long |
| 1027 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 1028 | 160mm dia pipe |
| 1029 | 110mm dia pipe |
| 1030 | 90mm dia pipe |
| 1031 | Providing and fixing in position 32 mm dia G.I waste pipe embedded in wall upto floor level including cost of fittings complete as required by the Engineer-in-charge. |
| 1032 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 1033 | 110mm dia pipe |
| 1034 | 90mm dia pipe |
| 1035 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I.soil waste, vent or antisyhonage pipes to wallscomplete in all respects including cutting andmaking good the walls and floors etc. and painting. |
| 1036 | a) for 100mm dia pipe. |
| 1037 | a) for 90mm dia pipe. |
| 1038 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 1039 | For 160mm o/d pipes |
| 1040 | Single Tee with Door |
| 1041 | Door Elbow 90 degree (all side socket) |
| 1042 | Elbow 90 degree (all side socket) |
| 1043 | Coupler |
| 1044 | Reducing Single Y 160mm x 110mm |
| 1045 | Providing and fixing 160mm END CAP with including fittings complete. |
| 1046 | For 110mm o/d pipes |
| 1047 | Door Cap |
| 1048 | Single Tee With Door |
| 1049 | Single Tee |
| 1050 | Door Elbow 90 Degree (All side socketed) |
| 1051 | Elbow 90 Degree (All side socketed) |
| 1052 | Vent Cowls |
| 1053 | Coupler |
| 1054 | P Trap/Floor Trap 110mm x 110mm |
| 1055 | 110x110x90mm |
| 1056 | For 90mm o/d pipes |
| 1057 | Door Cap |
| 1058 | Single Tee With Door |
| 1059 | Single Tee |
| 1060 | Door elbow 90 degree (all side socket) |
| 1061 | Elbow 90 degree (all side socket) |
| 1062 | Vent Cowls |
| 1063 | Coupler |
| 1064 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the walls etc. |
| 1065 | 16mm dia nominal outer dia pipes |
| 1066 | 20mm dia nominal outer dia pipes |
| 1067 | 25mm dia nominal outer dia pipes |
| 1068 | 32mm dia nominal outer dia pipes |
| 1069 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.Size 75 mm x 75 mm |
| 1070 | INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge.. |
| 1071 | 20mm dia nominal bore |
| 1072 | 25mm dia nominal bore |
| 1073 | 32mm dia nominal bore |
| 1074 | 40mm dia nominal bore |
| 1075 | 50mm dia nominal bore |
| 1076 | 65mm dia nominal bore |
| 1077 | 80mm dia nominal bore |
| 1078 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 1079 | 15mm dia nominal bore |
| 1080 | 20mm dia nominal bore |
| 1081 | 25mm dia nominal bore |
| 1082 | 32mm dia nominal bore |
| 1083 | 40mm dia nominal bore |
| 1084 | 50mm dia nominal bore |
| 1085 | 65mm dia nominal bore |
| 1086 | 80mm dia nominal bore |
| 1087 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect Water Cooler Full Steel Body 150/150 ltr Capacity without Stablize |
| 1088 | RO Plant 500 LPH (Liter per hour)PLANT CAPACITY - 500 LPHRECOVERY - 50%ELECTRICAL CONNECTION - 415 V, 3 PHASE, 50 HZ TDS - < 100 PPM 1000L STORAGE TANK AND DRINKING FOUNTAIN |
| 1089 | Supply, installation, testing, and commissioning of wall-mounted / counter-mounted online water purifier (Aquaguard or equivalent approved make) featuring multi-stage purification process including sediment filter, activated carbon, Reverse Osmosis (RO) and Ultraviolet (UV) / Ultra-Filtration (UF) |
| 1090 | INTERNAL SEWERAGE SYSTEM |
| 1091 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metres for sewers and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric, lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of work upto 15 metre, for all works other than connections to complete in all trenches. For depth not exceeding 2 m. below Ground level |
| 1092 | All classes of soil except rocky |
| 1093 | pipe trenches |
| 1094 | Gully traps |
| 1095 | manhole |
| 1096 | Supply and laying of tipa sand under class SN 8 pipe |
| 1097 | mixing by mechanical means using concrete mixer volumetric type |
| 1098 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects |
| 1099 | 110mm o/d pipe |
| 1100 | 160mm o/d pipe |
| 1101 | Providing and fixing in position gully traps fixed incement concrete 1:4:8 complete with Grating150mm x 150mm, cover and frame clearopening 300mm x 300mm and out of side size330mm x 330mm and chamber including cost ofall bricks work in cement morter 1:5 cementconcrete 1:2:4 in coping around cover and frameetc. as per standard design minimum depth ofwater should be 150 mm with a minimum seal50mm.. |
| 1102 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 1103 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal |
| 1104 | Extra for every 0.30 metre depth of inspection chamber 600mm x 900mm inside |
| 1105 | Foot Rest for Manhole |
| 1106 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 1107 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metres for sewers and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric, lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of work upto 15 metre, for all works other than connections to complete in all trenches. For depth not exceeding 2 m. below Ground level All classes of soil except rocky |
| 1108 | pipe trenches |
| 1109 | manhole 600x900 |
| 1110 | manhole extra depth 600x900 |
| 1111 | mixing by mechanical means using concrete mixer volumetric type |
| 1112 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and IS code IS 458-2003 into trenches for alldepths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc 150mm R.C.C. Pipe NP -3 |
| 1113 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. With common burnt clay FPS (non modular) bricks of class designation 75 Inside size 75x120 cm and 120 cm deep |
| 1114 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.56 upto 1.80 m increase in depth.Inside size 75x120 cm |
| 1115 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 1116 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 1117 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 1118 | Extra For flooring for every additional storey |
| 1119 | 1st Floor |
| 1120 | 2nd Floor |
| 1121 | 3rd Floor |
| 1122 | 4th Floor |
| 1123 | 5th Floor |
| 1124 | 6th Floor |
| 1125 | 7th Floor |
| 1126 | Boys Hostel |
| 1127 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect |
| 1128 | Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 1129 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including ack Bolt Screw Pair 115mm long complete in all respect ii Size 550 mm x 400 mm x 815 mm |
| 1130 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.Vitreous chinaware standard white pedestal for wash hand basin. |
| 1131 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect |
| 1132 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (asrequired by the Engineer-in- Charge)Size 600mmx450mm |
| 1133 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.Double bowl Sink without drain board Overall size 1114 x 490 mm with bowl size 460x385x200mm including waste coupling |
| 1134 | Providing and fixing in position vitreous Chinaware white Senso urinal size 37 x 39 x 61 cm of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outerlength 75 mm complete in all respect. |
| 1135 | Providing and fixing partition for different type of urinals.Toughned Glass Partition 8mm thickness size 450 x 900 mm C/S |
| 1136 | Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer-incharge) complete in all respect. |
| 1137 | Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.Vertical Type 40 litre capacity water heater |
| 1138 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks |
| 1139 | CP Brass fittings |
| 1140 | Providing & fixing in position PVC flexible tubeconnection of approved make (to the approval of Engineer-in-charge ) complete in all respectPVC tube connection of size 15 mm x 450 mm with PTMT nut |
| 1141 | Providing and fixing Stainless steel health faucet complete in all respect. |
| 1142 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P. brass Bib cock with Wall flange |
| 1143 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P brass Sink mixer with swinging spout. (wall mounted) |
| 1144 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P.brass 15mm Angular stop cock withWall flange |
| 1145 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P. brass 3-Hole Basin Mixer Without Popup Waste System |
| 1146 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P. Brass Wall mixer with Non telephonic shower arrangement. |
| 1147 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P. brass overhead shower Φ180mm round shape single flow with shower arm with 20mm i/d Inlet and 300mm long round shape with 900 bend with flange. |
| 1148 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-incharge) complete in all respect. |
| 1149 | C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal. (Outer + Inner Body) |
| 1150 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge) complete in all respect. C.P. brass toilet roll holder with flap |
| 1151 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 1152 | 20mm i/d Brass Ball valves |
| 1153 | 25mm i/d Brass Ball valves |
| 1154 | 32mm i/d Brass Ball valves |
| 1155 | ABS Plastic Body Hand Dryer ABS Body Suitable design. 100% unbreakable ABS Body. Voltage: 220 V/50 Hz Rated Power: 2000 Watt Current: 9.2 A Blowing Volume: 900 M/minute. Blowing Rate: 25 m/s Dimension: 240x240x230 mm Drying time: 10 seconds RPM: 3000 revolutions/min Noise: 40 Db Sensing Range: 123 cm Hot Temperature: 30-50oC Continuous work Time: 60 Sec Temperature of wind: 40-54oc |
| 1156 | Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof |
| 1157 | Cutting holes upto 23cm square for pipes in flooring and roofs of bricks, tiles with lime concrete or cement concrete and making good the same & finishing according to existing finish where required. (c) Through floor or roof 15.00cm thick |
| 1158 | Cutting holes upto 23cm square for pipes in floor and roofs of cement concrete, reinforced concrete or reinforced brick work and making good the same & finishing according to existing finish where required. (c) Through floor or roof 15.00cm thick |
| 1159 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P. brass soap dish holder with glass dish |
| 1160 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 1161 | Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge) fixed in with rawl plugs and C.P brass screws complete in all respect.C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm |
| 1162 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge)with various fixtures complete in all respect. C.P. Brass extension piece, 25mm longto 50mm long |
| 1163 | C.P. brass towel rack 600mm long with lower hangers |
| 1164 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect.C.P. brass towel rail 600 mm long |
| 1165 | SOIL WASTE, VENT & RAIN WATER PIPES AND FITTINGS |
| 1166 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 1167 | 160mm dia pipe |
| 1168 | 110mm dia pipe |
| 1169 | 90mm dia pipe |
| 1170 | Providing and fixing in position 32 mm dia G.I waste pipe embedded in wall upto floor level including cost of fittings complete as required by the Engineer-in-charge. |
| 1171 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 1172 | 110mm dia pipe |
| 1173 | 90mm dia pipe |
| 1174 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I.soil waste, vent or antisyhonage pipes to wallscomplete in all respects including cutting andmaking good the walls and floors etc. and painting. |
| 1175 | a) for 100mm dia pipe. |
| 1176 | a) for 90mm dia pipe. |
| 1177 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 1178 | For 160mm o/d pipes |
| 1179 | Single Tee with Door |
| 1180 | Door Elbow 90 degree (all side socket) |
| 1181 | Elbow 90 degree (all side socket) |
| 1182 | Coupler |
| 1183 | Reducing Single Y 160mm x 110mm |
| 1184 | Providing and fixing 160mm END CAP with including fittings complete. |
| 1185 | For 110mm o/d pipes |
| 1186 | Door Cap |
| 1187 | Single Tee With Door |
| 1188 | Single Tee |
| 1189 | Door Elbow 90 Degree (All side socketed) |
| 1190 | Elbow 90 Degree (All side socketed) |
| 1191 | Vent Cowls |
| 1192 | Coupler |
| 1193 | P Trap/Floor Trap 110mm x 110mm |
| 1194 | 110x110x90mm |
| 1195 | For 90mm o/d pipes |
| 1196 | Door Cap |
| 1197 | Single Tee With Door |
| 1198 | Single Tee |
| 1199 | Door elbow 90 degree (all side socket) |
| 1200 | Elbow 90 degree (all side socket) |
| 1201 | Vent Cowls |
| 1202 | Coupler |
| 1203 | INTERNAL WATER SUPPLY WORKS |
| 1204 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 1205 | 16mm dia nominal outer dia pipes |
| 1206 | 20mm dia nominal outer dia pipes |
| 1207 | 25mm dia nominal outer dia pipes |
| 1208 | 32mm dia nominal outer dia pipes |
| 1209 | Cutting chase in brick walls in cement or in floorfor embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm |
| 1210 | INTERNAL - EXPOSED ON WALL :Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge.. |
| 1211 | Internal work-Exposed on wall |
| 1212 | 20mm dia nominal bore |
| 1213 | 25mm dia nominal bore |
| 1214 | 32mm dia nominal bore |
| 1215 | 40mm dia nominal bore |
| 1216 | 50mm dia nominal bore |
| 1217 | 62mm dia nominal bore |
| 1218 | 80mm dia nominal bore |
| 1219 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 1220 | 20mm dia nominal bore |
| 1221 | 25mm dia nominal bore |
| 1222 | 32mm dia nominal bore |
| 1223 | 40mm dia nominal bore |
| 1224 | 50mm dia nominal bore |
| 1225 | 65mm dia nominal bore |
| 1226 | 80mm dia nominal bore |
| 1227 | RO PLANT & DRINKING FOUNTAIN |
| 1228 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all Water Cooler Full Steel Body 150/150 ltr Capacity without Stablize |
| 1229 | RO Plant 500 LPH (Liter per hour)PLANT CAPACITY - 500 LPHRECOVERY - 50% ELECTRICAL CONNECTION - 415 V, 3 PHASE, 50 HZ TDS - < 100 PPM 1000L STORAGE TANK AND DRINKING FOUNTAIN |
| 1230 | Supply, installation, testing, and commissioning of wall-mounted / counter-mounted online water purifier (Aquaguard or equivalent approved make) featuring multi-stage purification process including sediment filter, activated carbon, Reverse Osmosis (RO) and Ultraviolet (UV) / Ultra-Filtration (UF) |
| 1231 | INTERNAL SEWERAGE SYSTEM |
| 1232 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metres for sewers and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric, lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of work upto 15 metre, for all works other than connections to complete in all trenches. For depth not exceeding 2 m. below Ground level |
| 1233 | All classes of soil except rocky |
| 1234 | pipe trenches |
| 1235 | Gully traps |
| 1236 | manhole |
| 1237 | manhole extra depth |
| 1238 | Supply and laying of tipa sand under class SN 8 pipe |
| 1239 | mixing by mechanical means using concrete mixer volumetric type |
| 1240 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects |
| 1241 | 110mm o/d pipe |
| 1242 | 160mm o/d pipe |
| 1243 | Providing and fixing in position gully traps fixed incement concrete 1:4:8 complete with Grating150mm x 150mm, cover and frame clearopening 300mm x 300mm and out of side size330mm x 330mm and chamber including cost ofall bricks work in cement morter 1:5 cementconcrete 1:2:4 in coping around cover and frameetc. as per standard design minimum depth ofwater should be 150 mm with a minimum seal 50mm.100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 1244 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 600mm x 900mm inside with 455mm x 455mm cover and frame light dutydouble seal |
| 1245 | Extra for every 0.30 metre depth of inspection chamber 600mm x 900mm inside |
| 1246 | Foot Rest for Manhole |
| 1247 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 1248 | INTERNAL RAIN WATER DRAINAGE SYSTEM |
| 1249 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metres for sewers and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric, lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of work upto 15 metre, for all works other than connections to complete in all trenches. For depth not exceeding 2 m. below Ground level All classes of soil except rocky |
| 1250 | pipe trenches |
| 1251 | manhole 600x900 |
| 1252 | manhole extra depth 600x900 |
| 1253 | mixing by mechanical means using concrete mixer volumetric type |
| 1254 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc 150mm R.C.C. Pipe NP -3 |
| 1255 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mixby using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. With common burnt clay FPS (non modular) bricks of class designation 75 Inside size 75x120 cm and 120 cm deep |
| 1256 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.56 upto 1.80 m increase in depth. Inside size 75x120 cm |
| 1257 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 1258 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 1259 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 1260 | Extra For flooring for every additional storey |
| 1261 | 1st Floor |
| 1262 | 2nd Floor |
| 1263 | 3rd Floor |
| 1264 | 4th Floor |
| 1265 | 5th Floor |
| 1266 | Girls HostelSUBHEAD-I INTERNAL FIRE HYDRANT & SPRINKLER SYSTEMNote:-Fire noc will be taken from authorized department in contractor scope |
| 1267 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.900 lpm at 35 m Head |
| 1268 | Providing and fixing S.S Pressure Gauge complete as required complete in all respect.Dial diameter 100mm calibration 0-16 Kg |
| 1269 | Supplying & fixing Air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mmheight with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required |
| 1270 | Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet |
| 1271 | Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.100 mm dia |
| 1272 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. :100 mm dia |
| 1273 | Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra A(Class PN-1.0 as per ISI with rubber Flap)100mm dia |
| 1274 | INTERNAL HYDRANT |
| 1275 | Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects |
| 1276 | Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required. |
| 1277 | Supplying, Installation, Testing andCommissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type- 2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect30 m |
| 1278 | Supplying, Installation, Testing and Commissioning of Non-percolating flexible CP HOSE as per IS:8423 / 1994 ISI marked 63mm dia x 15 m long complete with instantaneous type gun-metal 63 mm dia male & female coupling (IS: 903) bound and riveted to hose pipe |
| 1279 | Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect. |
| 1280 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc 1200 mm wide x 900 mm high x 400mm deep Size |
| 1281 | Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank):Two Way inlet connection |
| 1282 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks |
| 1283 | SUBHEAD-II : FIRE EXTINGUSHER |
| 1284 | Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 3 Kg. Capacity |
| 1285 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect4.5 Kg. Capacity |
| 1286 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect6 Kg. Capacity |
| 1287 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. |
| 1288 | SUBHEAD-III : FIRE CONTROL PANELS |
| 1289 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.Same as above item but following mountings. INCOMER:- 1 Nos. 100 Amps. 4P MCCB ( 35 KA) 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASSBUS BARS:- 150 Amps. TP&N aluminium bus bars OUT GOINGS:- 2 Nos.25 Amps. TPN MCB (10 KA) |
| 1290 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-4 Core X 10 sqmm. Aluminium Armoured |
| 1291 | Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-4 Core X 10 sqmm. Aluminium Armoured |
| 1292 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-2 C x 2.5 Sqmm |
| 1293 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-3 C x 2.5 Sqmm |
| 1294 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 1295 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 1296 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 32mm dia.(On Surface) |
| 1297 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-Cable Tray Size 150mm x 50mm x 50mm(2mm thick) |
| 1298 | Fire Fighting System operator as per DC Rate of Skilled Labour of Rs. 18000/- per operator x 2=36000/- monthlay and yearly amount for Fire Fire System (Rates are subjected to change as per the amendment in the DC rates). For 7 Years |
| 1299 | Fire Fighting Boys hostel |
| 1300 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.]900 lpm at 35 m Head |
| 1301 | Providing and fixing S.S Pressure Gauge complete as required complete in all respect.Dial diameter 100mm calibration 0-16 Kg |
| 1302 | Supplying & fixing Air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mmheight with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required |
| 1303 | Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet |
| 1304 | Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.100 mm dia |
| 1305 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. :100 mm dia |
| 1306 | Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra A(Class PN-1.0 as per ISI with rubber Flap)100mm dia |
| 1307 | INTERNAL HYDRANT |
| 1308 | Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects |
| 1309 | Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required. |
| 1310 | Supplying, Installation, Testing andCommissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type- 2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect30 m |
| 1311 | Supplying, Installation, Testing and Commissioning of Non-percolating flexible CP HOSE as per IS:8423 / 1994 ISI marked 63mm dia x 15 m long complete with instantaneous type gun-metal 63 mm dia male & female coupling (IS: 903) bound and riveted to hose pipe |
| 1312 | Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect. |
| 1313 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc1200 mm wide x 900 mm high x 400 mm deep Size |
| 1314 | Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank):Two Way inlet connection |
| 1315 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer Tanks |
| 1316 | SUBHEAD-II : FIRE EXTINGUSHER |
| 1317 | Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:3 Kg. Capacity |
| 1318 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect4.5 Kg. Capacity |
| 1319 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect6 Kg. Capacity |
| 1320 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. |
| 1321 | SUBHEAD-III : FIRE CONTROL PANELS |
| 1322 | supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.Same as above item but following mountings. INCOMER:- 1 Nos. 100 Amps. 4P MCCB ( 35 KA) 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASSBUS BARS:- 150 Amps. TP&N aluminium bus bars OUT GOINGS:- 2 Nos.25 Amps. TPN MCB (10 KA) |
| 1323 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-4 Core X 10 sqmm. Aluminium Armoured |
| 1324 | Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-4 Core X 10 sqmm. Aluminium Armoured |
| 1325 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-2 C x 2.5 Sqmm |
| 1326 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-3 C x 2.5 Sqmm |
| 1327 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 1328 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 32mm dia.(On Surface) |
| 1329 | Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-Cable Tray Size 150mm x 50mm x 50mm(2mm thick) |
| 1330 | Fire Fighting System operator as per DC Rate of Skilled Labour of Rs. 18000/- per operator x 2=36000/- monthlay and yearly amount for Fire Fire System (Rates are subjected to change as per the amendment in the DC rates). For 7 Years |
| 1331 | HVAC FOR GIRLS HOSTEL |
| 1332 | SPLIT AC (Inverter model)Supply, installation,testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A / ecofriendly gas. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to 50 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, connection copper lead wire,condensed water outlet pipe . complete etc as required. Outdoor/indoor units should be of same make (brand)1.5 TR star rating 5 star. |
| 1333 | CASSETTE AC UNITSupply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand)3.0 TR three phase. |
| 1334 | Refrigerant PipingProviding and fixing of copper soft/hard refrigerant piping with UV coating along (Circuit length) with control cabling and earthing should be insulated with 9 mm thick pipe section of nitrile rubber. |
| 1335 | Cassette Split Unit 3.0 TR 6/8 & 3/8 |
| 1336 | Hi Wall Split Unit 1.5 TR5/8 & 3/8 |
| 1337 | Drain PipingProviding and fixing of CPVC ,6 Kg/ Cm² drain water piping with fittings ,support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification.25 mm dia |
| 1338 | Outdoor stand fabricationSupply, fabrication / Installation and erection of angle/channel/flat iron stand, hanging arrangement for air conditioning machines etc, back /support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of enamel paint as required as per specification. |
| 1339 | Stand for 1.5 TR Hi Wall Split Unit |
| 1340 | Stand for 3.0 TR Cassette Split Unit |
| 1341 | CablingSupply, Installation and installation of cable for Inoor to outdoor for Hi Wall & Cassette split units as required as per specification. |
| 1342 | 4C - 2.5 Sq.mm |
| 1343 | LIFT WELLPRESSURIZATIONSupply, erection, testing and commissioning of ceiling hunged Tube / Vane Axial flow fans with adjustable pitch blade , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 6 / 4 pole, three phase A.C supply of Class \\"H\\" insulation and shall IE -3 with support, mountings with vibration isolator spring and fire rated canvas flexible connection etc. & of following capacity as per approved tender drawings.(Noise Level shall not be more than 90 DB at a distance of 3 metres).Note Fan shall be AMCA Certified.Air Qty. = 14000 CFMStatic Pressure = 30 mm WgMotor = Not exceed 5.5 Kw. |
| 1344 | For PRESSURIZATION FAN16A TPN MCB for 16 A with DOL Starter, overload relay, start / stop push buttons, phase indication lights with protection fuse, on / off / trip indication lights with protection fuse, ammeter ( 0-16 A) with single CT, single phase preventer. Auto Manual Selector switch. MCB shall be of 10KA Controls & interlocking accessories as required. |
| 1345 | POWER & CONTROL CABLINGSupplying, laying, effecting proper termination, testing & commissioning of the following POWER CABLE sizes of 1.1 KV - PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured aluminium conductor cables conforming to relevant latest amended Indian Standardsas per specification standard.3C x 4 Sq. mm |
| 1346 | Earthing Strip / Wires.Providing and fixing 10 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as required |
| 1347 | Cable TraySupply and installing following size of perforated painted with powder coating M.S Cable trays with perforation not more than 17.5% , in convinient sections , joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts , painting suspenders etc as required.150mm x 50mm x 1.6 mm thick |
| 1348 | Factory Fabricated DuctingSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with RTV sealant & neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 1349 | Thickness 0.63 mm sheet |
| 1350 | Thickness 0.80 mm sheet |
| 1351 | Thickness 1.00 mm sheet |
| 1352 | Thickness 1.25 mm sheet |
| 1353 | Site Fabricated DuctingSupply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular/round ducting complete with RTV sealant & neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 1354 | Thickness 0.63 mm sheet 120 GSM |
| 1355 | Thickness 0.80 mm sheet 120 GSM |
| 1356 | Thickness 1.00 mm sheet 120 GSM |
| 1357 | Thickness 1.25 mm sheet 120 GSM |
| 1358 | G.I Volume Control Dampers (VCD)Supply, installation, balancing and commissioning of G.I Volume control duct damper complete with neoprene rubber gaskets, nuts , bolts , screws linkages , flanges etc, as required. |
| 1359 | Supply & fixing of powder coated extruded aluminium Fresh Air / Exhasut louvers and bird screen with dampers as per specifications |
| 1360 | Canvass ConnectionSupply & fixing of fire retardent Double canvass connection.complete in all respect including all necessary accessaries and fittings as required as per specifications. |
| 1361 | HVAC FOR BOYS HOSTEL |
| 1362 | SPLIT AC (Inverter model)Supply, installation,testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A / ecofriendly gas. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to 50 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, connection copper lead wire,condensed water outlet pipe . complete etc as required. Outdoor/indoor units should be of same make (brand).1.5 TR star rating 5 star |
| 1363 | CASSETTE AC UNIT Supply installation testing and commissioning of split type ceiling cassette Slim line/floor standing air conditioning unit of capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/ecofriendly green gas only, cordless remote control, auto air swing louvers, connection copper lead wire between outdoor and indoor unit, connection copper lead wire upto 1.5 mtr., excluding connection copper pipe of required size, insulation, floor stand for outdoor unit, condense water outlet complete etc as required. Outdoor/indoor units should be of same make (brand).3.0 TR three phase |
| 1364 | Refrigerant PipingProviding and fixing of copper soft/hard refrigerant piping with UV coating along (Circuit length) with control cabling and earthing should be insulated with 9 mm thick pipe section of nitrile rubber. |
| 1365 | Cassette Split Unit 3.0 TR6/8 & 3/8 |
| 1366 | Hi Wall Split Unit 1.5 TR5/8 & 3/8 |
| 1367 | Drain PipingProviding and fixing of CPVC ,6 Kg/ Cm² drain water piping with fittings ,support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification.25 mm dia |
| 1368 | Outdoor stand fabricationSupply, fabrication / Installation and erection of angle/channel/flat iron stand, hanging arrangement for air conditioning machines etc, back /support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of enamel paint as required as per specification. |
| 1369 | Stand for 1.5 TR Hi Wall Split Unit |
| 1370 | Stand for 3.0 TR Cassette Split Unit |
| 1371 | CablingSupply, Installation and installation of cable for Inoor to outdoor for Hi Wall & Cassette split units as required as per specification.4C - 2.5 Sq.mm |
| 1372 | VENTILATIONSupply, erection, testing and commissioning of ceiling hunged Tube / Vane Axial flow fans with adjustable pitch blade , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 6 / 4 pole, three phase A.C supply of Class \\"H\\" insulation and shall IE -3 with support, mountings with vibration isolator spring and fire rated canvas flexible connection etc. & of following capacity as per approved tender drawings.(Noise Level shall not be more than 90 DB at a distance of 3 metres).Note Fan shall be AMCA Certified.Air Qty. = 12500 CFMStatic Pressure = 30 mm WgMotor = Not exceed 5.5 Kw. |
| 1373 | For PRESSURIZATION FAN16A TPN MCB for 16 A with DOL Starter, overload relay, start / stop push buttons, phase indication lights with protection fuse, on / off / trip indication lights with protection fuse, ammeter ( 0-16 A) with single CT, single phase preventer. Auto Manual Selector switch. MCB shall be of 10KA Controls & interlocking accessories as required. |
| 1374 | POWER & CONTROL CABLINGSupplying, laying, effecting proper termination, testing & commissioning of the following POWER CABLE sizes of 1.1 KV - PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured aluminium conductor cables conforming to relevant latest amended Indian Standardsas per specification standard.3C x 4 Sq. mm |
| 1375 | Earthing Strip / Wires.Providing and fixing 10 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as required |
| 1376 | Cable TraySupply and installing following size of perforated painted with powder coating M.S Cable trays with perforation not more than 17.5% , in convinient sections , joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts , painting suspenders etc as required.150mm x 50mm x 1.6 mm thick |
| 1377 | Factory Fabricated DuctingSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with RTV sealant & neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 1378 | Thickness 0.63 mm sheet |
| 1379 | Thickness 0.80 mm sheet |
| 1380 | Thickness 1.00 mm sheet |
| 1381 | Thickness 1.25 mm sheet |
| 1382 | Site Fabricated DuctingSupply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular/round ducting complete with RTV sealant & neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 1383 | Thickness 0.63 mm sheet 120 GSM |
| 1384 | Thickness 0.80 mm sheet 120 GSM |
| 1385 | Thickness 1.00 mm sheet 120 GSM |
| 1386 | Thickness 1.25 mm sheet 120 GSM |
| 1387 | G.I Volume Control Dampers (VCD)Supply, installation, balancing and commissioning of G.I Volume control duct damper complete with neoprene rubber gaskets, nuts , bolts , screws linkages , flanges etc, as required. |
| 1388 | Supply & fixing of powder coated extruded aluminium Fresh Air / Exhasut louvers and bird screen with dampers as per specifications |
| 1389 | Canvass Connection Supply & fixing of fire retardent Double canvass connection.complete in all respect including all necessary accessaries and fittings as required as per specifications. |
| 1390 | Sub Station |
| 1391 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 1392 | Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect |
| 1393 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect ii Size 550 mm x 400 mm x 815 mm |
| 1394 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 1395 | Vitreous chinaware standard white pedestal for wash hand basin. |
| 1396 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (asrequired by the Engineer-in- Charge)Size 600mmx450mm |
| 1397 | CP Brass fittings |
| 1398 | Providing & fixing in position PVC flexible tubeconnection of approved make (to the approval of Engineer-in-charge ) complete in all respect |
| 1399 | PVC tube connection of size 15 mm x 450 mm with PTMT nut |
| 1400 | Providing and fixing Stainless steel health faucet complete in all respect. |
| 1401 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. |
| 1402 | C.P. brass Bib cock with Wall flange |
| 1403 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. |
| 1404 | C.P.brass 15mm Angular stop cock with Wall flange |
| 1405 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P. brass 3-Hole Basin Mixer Without Popup Waste System |
| 1406 | C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal. (Outer +Inner Body) |
| 1407 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P. brass toilet roll holder with flap |
| 1408 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including allcarriages complete. |
| 1409 | 15mm i/d Brass Ball valves |
| 1410 | 20mm i/d Brass Ball valves |
| 1411 | 25mm i/d Brass Ball valves |
| 1412 | 40mm i/d Brass Ball valves |
| 1413 | Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof |
| 1414 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. C.P. brass soap dish holder with glass dish |
| 1415 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 1416 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge) complete in all respect. |
| 1417 | C.P brass towel ring square |
| 1418 | SOIL WASTE, VENT & RAIN WATER PIPES AND FITTINGS |
| 1419 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 1420 | 160mm dia pipe |
| 1421 | 110mm dia pipe |
| 1422 | 90mm dia pipe |
| 1423 | Providing and fixing in position 32 mm dia G.I waste pipe embedded in wall upto floor level including cost of fittings complete as required by the Engineer-in-charge. |
| 1424 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 1425 | 160mm dia pipe |
| 1426 | 110mm dia pipe |
| 1427 | 90mm dia pipe |
| 1428 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I.soil waste, vent or antisyhonage pipes to wallscomplete in all respects including cutting andmaking good the walls and floors etc. andpainting. |
| 1429 | a) for 100mm dia pipe. |
| 1430 | a) for 90mm dia pipe. |
| 1431 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its originalcondition but excluding cost of lead joining. |
| 1432 | Single Tee with Door |
| 1433 | Door Elbow 90 degree (all side socket) |
| 1434 | Elbow 90 degree (all side socket) |
| 1435 | Coupler |
| 1436 | Reducing Single Y 160mm x 110mm |
| 1437 | Providing and fixing 160mm END CAP with including fittings complete. |
| 1438 | For 110mm o/d pipes |
| 1439 | Door Cap |
| 1440 | Single Tee With Door |
| 1441 | Single Tee |
| 1442 | Door Elbow 90 Degree (All side socketed) |
| 1443 | Elbow 90 Degree (All side socketed) |
| 1444 | Vent Cowls |
| 1445 | Coupler |
| 1446 | P Trap/Floor Trap 110mm x 110mm |
| 1447 | 110x110x90mm |
| 1448 | INTERNAL WATER SUPPLY WORKS |
| 1449 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 1450 | 16mm dia nominal outer dia pipes |
| 1451 | 20mm dia nominal outer dia pipes |
| 1452 | 25mm dia nominal outer dia pipes |
| 1453 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 1454 | Size 75 mm x 75 mm |
| 1455 | INTERNAL - EXPOSED ON WALL :Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge.. |
| 1456 | Internal work-Exposed on wall |
| 1457 | 15mm dia nominal bore |
| 1458 | 20mm dia nominal bore |
| 1459 | 25mm dia nominal bore |
| 1460 | 32mm dia nominal bore |
| 1461 | 40mm dia nominal bore |
| 1462 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 1463 | 15mm dia nominal bore |
| 1464 | 20mm dia nominal bore |
| 1465 | 25mm dia nominal bore |
| 1466 | 32mm dia nominal bore |
| 1467 | 40mm dia nominal bore |
| 1468 | INTERNAL SEWERAGE SYSTEM |
| 1469 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metres for sewers and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric, lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of work upto 15 metre, for all works other than connections to complete in all trenches. |
| 1470 | For depth not exceeding 2 m. below Ground level |
| 1471 | All classes of soil except rocky |
| 1472 | pipe trenches |
| 1473 | Gully traps |
| 1474 | Supply and laying of tipa sand under class SN 8 pipe |
| 1475 | mixing by mechanical means using concrete mixer volumetric type |
| 1476 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects |
| 1477 | 110mm o/d pipe |
| 1478 | Providing and fixing in position gully traps fixed incement concrete 1:4:8 complete with Grating150mm x 150mm, cover and frame clearopening 300mm x 300mm and out of side size330mm x 330mm and chamber including cost ofall bricks work in cement morter 1:5 cementconcrete 1:2:4 in coping around cover and frameetc. as per standard design minimum depth ofwater should be 150 mm with a minimum seal50mm.. |
| 1479 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 1480 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 1481 | 600mm x 900mm inside with 455mm x 455mm cover and frame light dutydouble seal |
| 1482 | Foot Rest for Manhole |
| 1483 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 1484 | EXTERNAL SEWERAGE SYSTEM |
| 1485 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metres for sewers and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric, lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of work upto 15 metre, for all works other than connections to complete in all trenches. |
| 1486 | For depth not exceeding 2 metres but not exceeding 3 metres below naturalground level : |
| 1487 | All classes of soil except rocky |
| 1488 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 1489 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 1490 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metres for sewers and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric, lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of work upto 15 metre, for all works other than connections to complete in all trenches.For depth not exceeding 2 m. below Ground levelAll classes of soil except rocky |
| 1491 | pipe trenches (1X0.8X2 =1.6) |
| 1492 | manhole 750x120 (1.8X1.8X 2 =6.5) |
| 1493 | manhole 900x1500 (2X2X2 =8) |
| 1494 | manhole 1200x1800(2X2X2 =8) |
| 1495 | extra depth 750x120 (1.8X1.8X.6 =2) |
| 1496 | extra depth 900x1500 (2X2X.6 =2.5) |
| 1497 | extra depth 1200x1800(2X2X.6 =2.5) |
| 1498 | For depth not exceeding 2 metres but not exceeding 3 metres below natural groundlevel :All classes of soil except rocky (1X1X1 =1) |
| 1499 | Provding and fixing timbering on face of trenches if required for sewers and manholes for item 29.4 and 29.5 irrespective of the depth, measuring each timbered surfaces of trench on which timbering is done. |
| 1500 | For trench heavy width up to 1 mtr |
| 1501 | For trench having width above 1m andupto 2m |
| 1502 | For trench having width above 2m andupto 3m |
| 1503 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Ashirwad, Ajay, Astral or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects |
| 1504 | 250 mm. Pipes |
| 1505 | 300 mm. Pipes |
| 1506 | Supply and laying of tipa sand under class SN 8 pipe |
| 1507 | Providing, lowering in trenches to correct gradient and allignments, jointing with tytone rubber joint and cutting of RCC S/S pipes having inside HDPE. lining ISI marekd as per ISI code IS:458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc.,cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and to ensure this, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer incharge including all cartage etc copmplete in all respects (R.C.C. pipe with inside H.D.P.E. lining class- NP-3) |
| 1508 | 450 mm. dia. RCC Pipes |
| 1509 | Cement concrete 1:5:10 with brick ballast 40mm gaugemixing by mechanical means using concrete mixer volumetric type 1X.6X.1 |
| 1510 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 1511 | Inside size 75x120 cm and 120 cm deep |
| 1512 | Extra payable for every 0.30 m additionaldepth of manhole chamber in item 29.85 upto1.80 m increase in depth Inside size 75x120 cm |
| 1513 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 1514 | Inside size 90x150 cm and 120 cm deep |
| 1515 | Extra payable for every 0.30 m additionaldepth of manhole chamber in item 29.85 upto1.80 m increase in depth.Inside size 90x150 cm |
| 1516 | hghkkghgg |
| 1517 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 1518 | Inside size 120x180 cm and 120 cmdeep |
| 1519 | Extra payable for every 0.30 m additionaldepth of manhole chamber in item 29.85 upto1.80 m increase in depth.Inside size 120x180 cm |
| 1520 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 1521 | Inside size 150x180 cm and 120 cmdeep |
| 1522 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.85 upto 1.80 m increase in depth.nside size 150x180 cm |
| 1523 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm asper standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanentidentification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 1524 | RISING MAIN AND BYE PASS ARRANGEMENT |
| 1525 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring. |
| 1526 | 150mm dia Ductile iron double flanged |
| 1527 | 100mm dia Ductile iron double flanged |
| 1528 | Supply CI specials such as Bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete. (10 % of item No. 1) |
| 1529 | Excavation by mechanical means(JC B or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. an removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respectEarth work upto 1.5 m. Depth forAll classes of soil except rocky pipe trenches (1X.75X1.5 =1.13) |
| 1530 | Excavation of trenches in a Streets, Lanes or in Open Area for Storm Sewers and Manholes to Full Depths as Shown in Drawings,excluding Shoring, Timbering of Poling Board Frame System Type, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines.night signals, profiles, Pegs, Sight rails, boning rods, crossing over trenches for access to the houses, watching, fencing etc., fixing and maintenance of caution boards, refilling trenches, watering of refill in 15 cm layers, ramming and restoration of surface to original conditions and removal of Surplus Spoil from the Site of Works, for all Works other thanconnections to Ventilating Shafts upto a Leadof 15 mt For depth not exceeding 2 m. below Ground level All classes of soil except rocky |
| 1531 | manhole 600x900 (.8X1X0.6 =0.48) |
| 1532 | manhole450x450 (0.6X0.6X0.6 =0.22 |
| 1533 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). |
| 1534 | 150mm diameter |
| 1535 | 100mm diameter |
| 1536 | 80mm diameter |
| 1537 | Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. |
| 1538 | 80mm diameter |
| 1539 | 100mm diameter |
| 1540 | DISTRIBUTION SYSTEM |
| 1541 | EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot &cold water supply including all CPVC plain& brass threaded fittings. This includes ointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge. |
| 1542 | 25mm dia nominal bore |
| 1543 | 32mm dia nominal bore |
| 1544 | 40mm dia nominal bore |
| 1545 | 50mm dia nominal bore |
| 1546 | 65mm dia nominal bore (inner dia62 mm) |
| 1547 | 80mm dia nominal bore (inner dia 75mm) |
| 1548 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 1549 | 25mm dia nominal bore |
| 1550 | 32mm dia nominal bore |
| 1551 | 40mm dia nominal bore |
| 1552 | 50mm dia nominal bore |
| 1553 | 65mm dia nominal bore |
| 1554 | 80mm dia nominal bore |
| 1555 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design |
| 1556 | 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double sea |
| 1557 | Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 1558 | PUMPS & FILTERS FOR WATER SUPPLY |
| 1559 | VERTICAL MULTISTAGE PUMP (domestic)Product Configuration Pump Classification: Hydro-Pneumatic Booster System Pump Construction: Pump With Motor Parallel Pumping System Numbers of Pump in System: 3 Pump Component Materials Version: Cast Iron & S.S AISI 304 Seal Material Carbon/SiC/SS316/EPDM Bearing Material ramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Motor Specifications Mounting: IECEnclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE2 Motor Manufacturer: Lubi System Components Accessories: Included Header Flange Rating: PN 16 Pump Controller: Single VFD with HMI & PLC Pump Controller Rating: 5.5 HP HPN Pressure Tank: 200 litre Y Strainer: Not Included |
| 1560 | VERTICAL MULTISTAGE PUMP (FLUSHING) Product Configuration Pump Classification: Hydro-Pneumatic Booster System Pump Construction: Pump With Motor Parallel Pumping System Numbers of Pump in System: 3 Pump Component Materials Version:Cast Iron & S.S AISI 30 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Motor Specifications Mounting: IECEnclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE2 Motor Manufacturer: Lubi System Components Accessories: Included Header Flange Rating: PN 16 Pump Controller: Single VFD with HMI & PLC Pump Controller Rating: 4 HP HPN Pressure Tank: 200 litreY Strainer: Not Included |
| 1561 | VERTICAL MULTISTAGE PUMP (IRRIGATION ) Product ConfigurationPump Classification: Hydro-Pneumatic Booster System Pump Construction: Pump With Motor Parallel Pumping System Numbers of Pump in System: 2 Pump Component Materials Version: Cast Iron & S.S AISI 304 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Motor Specifications Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE2 Motor Manufacturer: Lubi System Components Accessories: Included Header Flange Rating: PN 16Pump Controller: Single VFD with HMI & PLC Pump Controller Rating: 4 HPHPN Pressure Tank: 200 litreY Strainer: Not Included |
| 1562 | WTP Filters (ACF & MGF) including Disinfections Product ConfigurationFilter Classification: ACF & MGF Construction: Filters With Motor Parallel Pumping System Numbers of Filters in System: 2 Filters Component Materials Version: Cast Iron & S.S AISI 304 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Motor Specifications Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE2 Motor Manufacturer: Eureka System Components Accessories: Included Header Flange Rating: PN 16 Filter Controller: Single VFD with HMI & PLC Pump Controller Rating: 4 HP HPN Pressure Tank: 200 litre Y Strainer: Not Included |
| 1563 | RAIN WATER DRAINAGE NETWORK |
| 1564 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metres for sewers and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric, lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of work upto 15 metre, for all works other than connections to complete in all trenches. |
| 1565 | For depth not exceeding 2 m. below Ground level |
| 1566 | All classes of soil except rocky |
| 1567 | pipe trenches (1X.3X2 =0.6) |
| 1568 | manhole 900x1500 (1.2X1.8X1.4 =3.1) |
| 1569 | extra depth 900x1500 (1.2X1.8X.3 =0.65) |
| 1570 | Providing, lowering in trenches to correctgradient and alignment, jointing with tytonrubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes arecompleted. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc |
| 1571 | 150mm R.C.C. Pipe NP -3 |
| 1572 | Cement concrete 1:5:10 with brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 1573 | Constructing brick masonry manhole incement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 1574 | Inside size 90x150 cm and 120 cm deep |
| 1575 | Extra payable for every 0.30 m additionaldepth of manhole chamber in item 29.85 upto1.80 m increase in depth. Inside size 90x150 cm |
| 1576 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 1577 | Constructing RCC precast perforated RCC. slab covered Drain with 150mm thick RCC 1.1.5.3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size) wall including earth excavation, 75mm thick bed concrete 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40mm nominal size) and 100mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: |
| 1578 | Drain 300 wide average. Depth 500cm with R.C.C. Slab |
| 1579 | Drain 450 wide average. Depth 750cm with R.C.C. Slab |
| 1580 | Drain 600 wide average. Depth 1200cm with R.C.C. Slab |
| 1581 | Drain 750 wide average. Depth 1500cm with R.C.C. Slab |
| 1582 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. |
| 1583 | Same as above item but following mountings. |
| 1584 | INCOMER:- |
| 1585 | 1 Nos. 63 Amps. 4P MCCB (16 KA) |
| 1586 | 1 Set phase indication lights (R, Y, B) |
| 1587 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 1588 | 1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASS |
| 1589 | BUS BARS:- |
| 1590 | 100 Amps. TP&N aluminium bus bars |
| 1591 | OUT GOINGS:- |
| 1592 | 7 Nos.25 Amps. TPN MCB (10 KA) |
| 1593 | Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra 80 mm nominal bore |
| 1594 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.80mm dia nominal bore |
| 1595 | INTERNAL - EXPOSED ON WALL :Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge..80mm dia nominal bore |
| 1596 | Kirloskar make sump pump Model 2200CW, 5 HP, 3 Phase, delivery pipe size 65 mm, |
| 1597 | Water Treatment Plant operator as per DC Rate of Skilled Labour of Rs. 18000.00 per operator x 4=72000.00 monthlay and yearly amount for Water Treatment Plant (Rates are subjected to change as per the amendment in the DC rates) |
| 1598 | RAIN WATER HARVESTINGRECHARGE PITS (08 Nos. ) |
| 1599 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.All kinds of soil |
| 1600 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 1601 | In all kind of soil upto 3.0m to 4.5m. depth |
| 1602 | In all kind of soil upto 4.5 m to 6.0m. depth |
| 1603 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 1604 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1605 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 1606 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1607 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 1608 | Centering and shuttering including strutting, propping etc. and remova of form for : |
| 1609 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 1610 | Centering and shuttering for flat surfaces such assuspended floors, roofs, landings, chajjas, shelves etc. |
| 1611 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on topsurface by ribbing or chequering besidesnecessary and adequate anchoring projections on tail length on 138 mm asper standard drawing and suitable towith stand the bend test and chemicalresistance test as per specification andhaving manufacturer's permanentidentification mark to be visible evenafter fixing, including fixing in manholeswith 230x150x75cm cement concreteblock 1:2:4 (1 cement: 2 sand: 4 stoneaggragate) complete as per design.with 230x150x75cm |
| 1612 | Providing and fixing RCC manhole covers only500mm i/d RCC man hole cover onlyas per ISI |
| 1613 | Boring/drilling bore well of required dia forcasing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/borelog, including hire & running charges of allequipments, tools, plants & machineriesrequired for the job, all complete as per direction of Engineer – in-charge, upto 90metre depth below ground level.300 mm dia. |
| 1614 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – incharge.150 mm nominal size dia |
| 1615 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1616 | Supplying at quarry site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe |
| 1617 | Supplying, filling, spreading & leveling coarse sand of size range 3 mm to 6 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 1618 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 1619 | DESILTING CHAMBER |
| 1620 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.All kinds of soil |
| 1621 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 1622 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size) |
| 1623 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1624 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation andplinth |
| 1625 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 1626 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 1627 | Centering and shuttering including strutting, propping etc. and remova of form for : |
| 1628 | Foundations, footings, bases of columns, etc. for mass concrete |
| 1629 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 1630 | Suspended floors, roofs, landings, balconies and access platform |
| 1631 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholeswith 230x150x75cm cement concreteblock 1:2:4 (1 cement: 2 sand: 4 stoneaggragate) complete as per design.with 230x150x75cm |
| 1632 | Providing and fixing RCC manhole coversonly.500mm i/d RCC man hole cover onlyas per ISI |
| 1633 | ELECTRO-MECHANICAL WORK : |
| 1634 | Design, Detailed engineering, Supplying, Installing and Testing & Commissioning of sewage treatment plant based on Moving bed bio reactor process (with air diffuser system) + Ultrafiltration system with sewage handling capacity 110 KLD. All the equipment, piping, pumps, blowers and electrical panel to be housed in a plant room. M.S. puddle flange (hot dip galvanized after fabrication), inlet, outlet overflow, vent, M.S. cover, drain channel with M.S. gratings, |
| 1635 | Sewage Treatment Plant operator as per DC Rate of Skilled Labour of Rs. 18000.00 per operator x 4=72000.00 monthlay and yearly amount for Sewage Treatment Plant (Rates are subjected to change as per the amendment in the DC rates) for 7 Years |
| 1636 | Tubewell (250 mm Dia straight and 300 mm deep) |
| 1637 | Resistivity test of soil |
| 1638 | Drilling of 550mm dia bore with Reverse rotatry Rig in all kinds of soil including the cost of consumables stores, fuel oil & transporation of rig to the site plete in all respect. |
| 1639 | Drilling of 550mm dia bore with Reverse Rotatry Rig upto 150m depth BGI. |
| 1640 | Drilling of 550mm dia boer with Reverse rotatry Rig Beyond 150m depth up to 300m. |
| 1641 | Erection and dismantling of boring plant including all arrangement for the site of work from the stage of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work, Pits for collection of water and water for drilling tube well be arranged by the firm / contractor at site at his own cost. |
| 1642 | In case the bore is converted into a tubewell payment of bore shall be made up to the ball plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore. The text bore beyond margin shall be paid at the rate of test bore drilling. |
| 1643 | Making electronic logging to borehole with electronic well logger including cost of equipment at site etc. complete in all respects. |
| 1644 | Supplying lowering of MS Pipe as per IS: 4270/2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 1645 | 250mm nominal diameter (weight 52.3 kg per metre) 8.0 mm thickness |
| 1646 | Supplying, fixing & lowering of stainless steel cage type wire would screen as per IS:8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S. welding electrode to lower the strainer into tubewell bore. |
| 1647 | 250 mm Steel Strainer (slot size) 0.75 mm) 7.3 mm thickness |
| 1648 | Supplying lowering and fixing of MS special socket to connect SS strainer to MS pipe duly welded with suitable grade welding electric road complete in all respects 10\\" 250mm i/d |
| 1649 | Supplying, fixing arid lowering of stainless steel socket as per IS 8110-2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respect.250 mm internal diameter |
| 1650 | Supplying & Fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the botto plug coplete in all respect.250 mm internal diameter (weight 52.30 kg per metre) 8.0 mm thickness |
| 1651 | Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 1652 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respects.250mm internal diameter |
| 1653 | Supplying & fixing of M.S. Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to hit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 1654 | Supplying at site Wooden Box of suitable size with Lid & locking arrangement for preserving strata.sample,collected from the bore. |
| 1655 | Supplying at site of gravel of 1/16\\" 1/8\\" sizes including pouring and packing in the annualar space between the pipes assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner. As per IS 4097/1967 with latest amendments {to be paid as per actual length of pipe} |
| 1656 | Providing of testing of urinium |
| 1657 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 1658 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-incharge incluidng cost of tools, appliances & consumable to the satisfaction of Engineer-in-chargeCapacity of Air compressor 500 cfm at 600 PSI |
| 1659 | Development and Stabilizing of the tubewell with submesible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 1660 | Supplying at site Tibba sand etc. including pouring and packing in the annular space between the pipes assembly and the bore above seal complete in all respect. |
| 1661 | Providing & Fixing Clay seal in gravel pack minimum 3 Mtr. (BIS 2800-2019) |
| 1662 | Providing & Fixing Sanitery seal (BIS 2800-2019) |
| 1663 | The water in the well and immediate aquifer surrounding the well. The volume of water in the screen and casting should be estimated and sufficient chlorine added to yield for water with chlorination of 1000 ppm. The solution should be poured into the well and thoroughly mixed in the well by surging with pump. The solution should remain in the well for at leaset 6 hours during which it should be surged at about 2 h inetrval . After expiration of contact time, the well should be pumped initially back into the well for abour 30 minute and late to waste until there is little of no odour or taste of chlorine in the dischaged water. It has been found that using hypochlorite is of 10% concentration, the requirement of hypochlorite is 10 liter for every cubic meter of water in the well to produce. |
| 1664 | Providing, Installing, testing and Commissioning of 01 No. electrically driven pumping set of reputed make capable of delivering 439 LPM against Head of 105m (20 bhp) complete in all respects. |
| 1665 | Provinding and laying , fixing, testing ISI Marked G.I. (as per IS 1239) B-Class , incuding cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. (100 mm dia) |
| 1666 | Providing and Fixing of submersible cable of 10.00 sqm core cable complete in all respects. |
| 1667 | Providing, installing, testing and Commissioning of 01 No. Control Panel with closed transition star delta with enclosure consiting of electrical appliances such as contactor, fuses, MCCB's, overload relays, isolator switches, wiring and connection complete in all respects. |
| 1668 | CI Fitting inside Pump Chamber |
| 1669 | Providing and installing 100mm dia delivery main (From Tube well to duct foot bend) including cost of CI/DF pipes, D/F, sluice valve, NRV, and specials such as CI bends, tail pieces, Tees, etc. Inside the pump chamber as per standard design complete in all respects. |
| 1670 | Providing, Installing, testing and Commissioning of 01 No. electrically acquitted diaphragm operated meatering system, chemical dozing chlorinator, suitable for delivering 0.5 to 6 Ltr bleaching powder solution/sodium hypo solution per hour under maximum delivery pressure upto 07 kg/sqcm and suction lift not less than 1.5m as per DWSS Standard specifications |
| 1671 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring. D.I. Pipe as per IS 8329 DI-K7 100mm i/d pipe lines laid complete |
| 1672 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6 m. x 0.6 m. |
| 1673 | Under Ground Tank |
| 1674 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m..Mechanical Means |
| 1675 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 1676 | Disposal of malba/surplus earth outside the premises including loading, unloading and carriage upto 3.00 km. |
| 1677 | CENTRING AND SHUTTERING |
| 1678 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 1679 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. |
| 1680 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 1681 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 1682 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 1683 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 1684 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey. |
| 1685 | Basement 1 |
| 1686 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 1687 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 1688 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 1689 | Reinforced cement concrete M-40 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 1690 | Reinforced cement concrete M-40 mechanically batch mixed using batch mixed using concrete mixer and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 1691 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 1692 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) |
| 1693 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 1694 | Basemnet 1 |
| 1695 | Gr. Floor |
| 1696 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres aboveplinth level. |
| 1697 | HOISTING, ROOFING AND WATER PROOFING |
| 1698 | Waterproofing of wet areas ( Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build-up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects. |
| 1699 | Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of Elastobar and Zycoprime/Equivalent after application of Zycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brushable. Apply the paste on surface with brush. Leave the surace for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementatios membrane using mixture of 1 Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed. |
| 1700 | Construction of unreinforced plain cement oncrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer sing batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to require lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 1701 | 12.5 mm thick cement plaster 1:5 |
| 1702 | 20mm thick cement plaster 1:6 in two coats work |
| 1703 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 1704 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 1705 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 1706 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 1707 | Factory manufactured solid flush door fixed in position iron hinges, etc excluding the cost of any fittings other than specified above but including labour for fixing the same in position Code : IS-2202-1(1999)Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick |
| 1708 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :250mm x 16mm |
| 1709 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 1710 | Extra rate for Steel Fe-415, Fe-500, Fe-550 (Integrated Plant Marked). |
| 1711 | Supplying and fixing door frames (Chowkat) consisting of frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per IS:513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones (as per approved colour), 3nos 100mm butt-hinges 2mm thick, 6Nos 1.2mm thick CRCA electroplated stiffner, 6nos M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished wiyh powder coated total thickness of coating 0.60mm of approved shade, fixed in position, including the cost of cement concrete for1:2:4 for fixing lugs complete in all respects as per drawing,design, specification & entire stasfication of Engineer-in-Charge18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.Door frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter. |
| 1712 | Providing and fixing stair case railing made out of M.S. Square bars 20x20mm as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects. |
| 1713 | KITCHEN EQUIPMENTS (Girls Hostel) |
| 1714 | L.P.G GAS PIPE LINE Make:- GENIST / HARMONEY / BALAJIActual measurement will be according to as per site conditions |
| 1715 | M.S CYLINDER BANK 154\\"X36”X42”(ACCESSORIES ARE NOT INCLUDED)Totally constructed in MS angle base of 40x40x5 mm supported with 12mm square wrought iron bars. Front doors are provided along with the locking arrangements made up of 18 SWG CR sheet is duly primered and painted to prevent from rust etcMake:- GENIST / HARMONEY / BALAJI |
| 1716 | MILKBOILER/TEABOILER. Make:- GENIST / HARMONEY / BALAJI |
| 1717 | MICROWAVE OVEN . Make:- GENIST / HARMONEY / BALAJI |
| 1718 | PICKUP COUNTER WITH OVER SHELF . Make:- GENIST / HARMONEY / BALAJI |
| 1719 | WORK TABLE FOR SUPPORT OF TWO BURNER RANGE |
| 1720 | TWO BURNER COOKING RANGE .Make:- GENIST / HARMONEY / BALAJI |
| 1721 | EXHAUST HOOD (Without Ducting Fixing & Extraction fan)FOR TWO BURNER RANGE |
| 1722 | JUICER (table top model) .Make:- GENIST / HARMONEY / BALAJI |
| 1723 | CONVEYOR TOASTER Make:- GENIST / HARMONEY / BALAJI |
| 1724 | WORK TABLE WITH SINK .Make:- GENIST / HARMONEY / BALAJI |
| 1725 | FOUR DOOR REFRIGERATOR .Make:- GENIST / HARMONEY / BALAJI |
| 1726 | WORK TABLE .Make:- GENIST / HARMONEY / BALAJI |
| 1727 | THREE BURNER COOKING RANGE .Make:- GENIST / HARMONEY / BALAJI |
| 1728 | EXHAUSTHOOD(With out Ducting .Fixing Extraction fan)for THREE burner RANGE |
| 1729 | LOWHT.TABLE fo rsupporting low height burner .Make:- GENIST / HARMONEY / BALAJI |
| 1730 | LOWHT. BURNER .Make:- GENIST / HARMONEY / BALAJI |
| 1731 | EXHAUSTHOOD(With out Ducting Fixing & Extractionfan)for LOWHEIGHT BURNER range .Make:- GENIST / HARMONEY / BALAJI |
| 1732 | THREE BURNER COOKING RANGE .Make:- GENIST / HARMONEY / BALAJI |
| 1733 | WORK TABLE FOR SUPPORT OF 03 BURNER COOKINGRANGE .Make:- GENIST / HARMONEY / BALAJI |
| 1734 | EXHAUSTHOOD(With out Ducting Fixing &Extractionfan) for THREE BURNER RANGE |
| 1735 | BULKCOOKER/boiler TILTING TYPE .Make:- GENIST / HARMONEY / BALAJI |
| 1736 | BULKFRYERTILTINGTYPE Cap.100Ltrs. Make:- GENIST / HARMONEY / BALAJI |
| 1737 | EXHAUST HOOD (Without Ducting Fixing & Extraction fan)for BULK COOKER & FRYER Size 1650x750x600mm |
| 1738 | WET GRINDER .Make:- GENIST / HARMONEY / BALAJI |
| 1739 | DOUGH KNEADING MACHINE .Make:- GENIST / HARMONEY / BALAJI |
| 1740 | POTATO PEELER .Make:- GENIST / HARMONEY / BALAJI |
| 1741 | PULVERISER(Std.) .Make:- GENIST / HARMONEY / BALAJI |
| 1742 | WORKTABLESUPPORTOF PULVERISOR .Make:- GENIST / HARMONEY / BALAJI |
| 1743 | WORK TABLE WITH SINK for vegetable washing .Make:- GENIST / HARMONEY / BALAJI |
| 1744 | CHOPPING BOARD for manual vegetable cutting .Make:- GENIST / HARMONEY / BALAJI |
| 1745 | VEGETABLE CUTTING MACHINE .Make:- GENIST / HARMONEY / BALAJI |
| 1746 | CHAPPATI COLLECTION TABLE .Make:- GENIST / HARMONEY / BALAJI |
| 1747 | CHAPPATI ROLLING TABLE .Make:- GENIST / HARMONEY / BALAJI |
| 1748 | CHAPPATI PLATE CUM PUFFER .Make:- GENIST / HARMONEY / BALAJI |
| 1749 | EXHAUSTHOOD(Without Ducting Fixing & Extraction fan) for chapatti plate .Make:- GENIST / HARMONEY / BALAJI |
| 1750 | FOOD TROLLEY WITH 4 ROUND PANS1RICETRAY & STORAGE beneath .Make:- GENIST / HARMONEY / BALAJI |
| 1751 | TRAYCARRIERTROLLE .Make:- GENIST / HARMONEY / BALAJI |
| 1752 | TRAY SET UP COUNTER WITH BAIN MARIE & DOUBLE OVER SHELVES .Make:- GENIST / HARMONEY / BALAJI |
| 1753 | STORAGE CABINET .Make:- GENIST / HARMONEY / BALAJI |
| 1754 | STORAGE RACK .Make:- GENIST / HARMONEY / BALAJI |
| 1755 | INGREDIENTBINS .Make:- GENIST / HARMONEY / BALAJI |
| 1756 | DUNNAGERACK .Make:- GENIST / HARMONEY / BALAJI |
| 1757 | POTRACK-3 TIER .Make:- GENIST / HARMONEY / BALAJI |
| 1758 | SOILED DISH LANDING TABLE WITH GARBAGE CHUTE .Make:- GENIST / HARMONEY / BALAJI |
| 1759 | THREE SINK UNIT .Make:- GENIST / HARMONEY / BALAJI |
| 1760 | CLEAN DISH TABLE .Make:- GENIST / HARMONEY / BALAJI |
| 1761 | CLEAN DISH RACK .Make:- GENIST / HARMONEY / BALAJI |
| 1762 | LPG MENIFOLD SYSTEM 3X3CYLENDER .Make:- GENIST / HARMONEY / BALAJI |
| 1763 | CENTRIFUGAL EXHAUST BLOWER .Make:- GENIST / HARMONEY / BALAJI |
| 1764 | S.S GRATING for kitchen drainage trough .Make:- GENIST / HARMONEY / BALAJI |
| 1765 | EXHAUST HOOD DUCTING .Make:- GENIST / HARMONEY / BALAJI |
| 1766 | [J] LAUNDRY EQUIPMENTS (Girls Hostel) |
| 1767 | Industrial Washer Extractor. Heavy Duty High Spin. Computer Controlled. Front Loading, Open Pocket. Top Suspension With Hydraulic Cushions. Full Stainless Steel Cabinet. Single Motor Frequency Drive. 5 Compartment Automatic Soap / Chemical Dispenser. 30 kg Capacity, Steam Heated.Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1768 | Drying Tumbler. Front Loading, Open Pocket. Reversible With Automatic Cool Down Feature. 30 kg Capacity, Steam Heated. Make:- Stefab/ Nat Steel / GENIST |
| 1769 | Flat Work Drying Ironer With Heated Chest. Return Feed Type. Roller Size : Ø 830 x 3300, Steam Heated. Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1770 | Flat Bed Press. Auto Timed, Pneumatically Operated. Head Size : 1500 x 750, Steam Heated. Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1771 | Vacuum Finishing Table. Table Top Size : 1200 x 750 Electric Steam Iron Teflon Shoe Condensate SeparatorMake:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1772 | Washroom Trolley 50 Kg made of stainless steel Overall Size : 762 x 509 x 863 ht. Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1773 | Dry Linen Trolley 50 Kg made of stainless steelOverall Size : 762 x 509 x 863 ht. Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1774 | Air Compressor, 7.5 HP Double Stage, 160 ltrs Tank Recommended Make: GENIST or Equivalent. |
| 1775 | Steam Boiler, 100 kg Capacity along with Water Softener Make: GENIST or Equivalent. |
| 1776 | KITCHEN EQUIPMENTS (Boys Hostel) |
| 1777 | L.P.G GAS PIPE LINE Make:- GENIST / HARMONEY / BALAJIActual measurement will be according to as per site conditions |
| 1778 | M.S CYLINDER BANK 154\\"X36”X42”(ACCESSORIES ARE NOT INCLUDED)Totally constructed in MS angle base of 40x40x5 mm supported with 12mm square wrought iron bars. Front doors are provided along with the locking arrangements made up of 18 SWG CR sheet is duly primered and painted to prevent from rust etcMake:- GENIST / HARMONEY / BALAJI |
| 1779 | MILKBOILER/TEABOILER. Make:- GENIST / HARMONEY / BALAJI |
| 1780 | MICROWAVE OVEN . Make:- GENIST / HARMONEY / BALAJI |
| 1781 | PICKUP COUNTER WITH OVER SHELF . Make:- GENIST / HARMONEY / BALAJI |
| 1782 | WORK TABLE FOR SUPPORT OF TWO BURNER RANGE |
| 1783 | TWO BURNER COOKING RANGE .Make:- GENIST / HARMONEY / BALAJI |
| 1784 | EXHAUST HOOD (Without Ducting Fixing & Extraction fan)FOR TWO BURNER RANGE |
| 1785 | JUICER (table top model) .Make:- GENIST / HARMONEY / BALAJI |
| 1786 | CONVEYOR TOASTER Make:- GENIST / HARMONEY / BALAJI |
| 1787 | WORK TABLE WITH SINK .Make:- GENIST / HARMONEY / BALAJI |
| 1788 | FOUR DOOR REFRIGERATOR .Make:- GENIST / HARMONEY / BALAJI |
| 1789 | WORK TABLE .Make:- GENIST / HARMONEY / BALAJI |
| 1790 | THREE BURNER COOKING RANGE .Make:- GENIST / HARMONEY / BALAJI |
| 1791 | EXHAUSTHOOD(With out Ducting .Fixing Extraction fan)for THREE burner RANGE |
| 1792 | LOWHT.TABLE fo rsupporting low height burner .Make:- GENIST / HARMONEY / BALAJI |
| 1793 | LOWHT. BURNER .Make:- GENIST / HARMONEY / BALAJI |
| 1794 | EXHAUSTHOOD(With out Ducting Fixing & Extractionfan)for LOWHEIGHT BURNER range .Make:- GENIST / HARMONEY / BALAJI |
| 1795 | THREE BURNER COOKING RANGE .Make:- GENIST / HARMONEY / BALAJI |
| 1796 | WORK TABLE FOR SUPPORT OF 03 BURNER COOKINGRANGE .Make:- GENIST / HARMONEY / BALAJI |
| 1797 | EXHAUSTHOOD(With out Ducting Fixing &Extractionfan) for THREE BURNER RANGE |
| 1798 | BULKCOOKER/boiler TILTING TYPE .Make:- GENIST / HARMONEY / BALAJI |
| 1799 | BULKFRYERTILTINGTYPE Cap.100Ltrs. Make:- GENIST / HARMONEY / BALAJI |
| 1800 | EXHAUST HOOD (Without Ducting Fixing & Extraction fan)for BULK COOKER & FRYER Size 1650x750x600mm |
| 1801 | WET GRINDER .Make:- GENIST / HARMONEY / BALAJI |
| 1802 | DOUGH KNEADING MACHINE .Make:- GENIST / HARMONEY / BALAJI |
| 1803 | POTATO PEELER .Make:- GENIST / HARMONEY / BALAJI |
| 1804 | PULVERISER(Std.) .Make:- GENIST / HARMONEY / BALAJI |
| 1805 | WORKTABLESUPPORTOF PULVERISOR .Make:- GENIST / HARMONEY / BALAJI |
| 1806 | WORK TABLE WITH SINK for vegetable washing .Make:- GENIST / HARMONEY / BALAJI |
| 1807 | CHOPPING BOARD for manual vegetable cutting .Make:- GENIST / HARMONEY / BALAJI |
| 1808 | VEGETABLE CUTTING MACHINE .Make:- GENIST / HARMONEY / BALAJI |
| 1809 | CHAPPATI COLLECTION TABLE .Make:- GENIST / HARMONEY / BALAJI |
| 1810 | CHAPPATI ROLLING TABLE .Make:- GENIST / HARMONEY / BALAJI |
| 1811 | CHAPPATI PLATE CUM PUFFER .Make:- GENIST / HARMONEY / BALAJI |
| 1812 | EXHAUSTHOOD(Without Ducting Fixing & Extraction fan) for chapatti plate .Make:- GENIST / HARMONEY / BALAJI |
| 1813 | FOOD TROLLEY WITH 4 ROUND PANS1RICETRAY & STORAGE beneath .Make:- GENIST / HARMONEY / BALAJI |
| 1814 | TRAYCARRIERTROLLE .Make:- GENIST / HARMONEY / BALAJI |
| 1815 | TRAY SET UP COUNTER WITH BAIN MARIE & DOUBLE OVER SHELVES .Make:- GENIST / HARMONEY / BALAJI |
| 1816 | STORAGE CABINET .Make:- GENIST / HARMONEY / BALAJI |
| 1817 | STORAGE RACK .Make:- GENIST / HARMONEY / BALAJI |
| 1818 | INGREDIENTBINS .Make:- GENIST / HARMONEY / BALAJI |
| 1819 | DUNNAGERACK .Make:- GENIST / HARMONEY / BALAJI |
| 1820 | POTRACK-3 TIER .Make:- GENIST / HARMONEY / BALAJI |
| 1821 | SOILED DISH LANDING TABLE WITH GARBAGE CHUTE .Make:- GENIST / HARMONEY / BALAJI |
| 1822 | THREE SINK UNIT .Make:- GENIST / HARMONEY / BALAJI |
| 1823 | CLEAN DISH TABLE .Make:- GENIST / HARMONEY / BALAJI |
| 1824 | CLEAN DISH RACK .Make:- GENIST / HARMONEY / BALAJI |
| 1825 | LPG MENIFOLD SYSTEM 3X3CYLENDER .Make:- GENIST / HARMONEY / BALAJI |
| 1826 | CENTRIFUGAL EXHAUST BLOWER .Make:- GENIST / HARMONEY / BALAJI |
| 1827 | S.S GRATING for kitchen drainage trough .Make:- GENIST / HARMONEY / BALAJI |
| 1828 | EXHAUST HOOD DUCTING .Make:- GENIST / HARMONEY / BALAJI |
| 1829 | [J] LAUNDRY EQUIPMENTS (Boys Hostel) |
| 1830 | Industrial Washer Extractor. Heavy Duty High Spin. Computer Controlled. Front Loading, Open Pocket. Top Suspension With Hydraulic Cushions. Full Stainless Steel Cabinet. Single Motor Frequency Drive. 5 Compartment Automatic Soap / Chemical Dispenser. 30 kg Capacity, Steam Heated.Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1831 | Drying Tumbler. Front Loading, Open Pocket. Reversible With Automatic Cool Down Feature. 30 kg Capacity, Steam Heated. Make:- Stefab/ Nat Steel / GENIST |
| 1832 | Flat Work Drying Ironer With Heated Chest. Return Feed Type. Roller Size : Ø 830 x 3300, Steam Heated. Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1833 | Flat Bed Press. Auto Timed, Pneumatically Operated. Head Size : 1500 x 750, Steam Heated. Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1834 | Vacuum Finishing Table. Table Top Size : 1200 x 750 Electric Steam Iron Teflon Shoe Condensate SeparatorMake:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1835 | Washroom Trolley 50 Kg made of stainless steel Overall Size : 762 x 509 x 863 ht. Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1836 | Dry Linen Trolley 50 Kg made of stainless steelOverall Size : 762 x 509 x 863 ht. Make:- Fabcare/ Stefab/ Nat Steel / GENIST |
| 1837 | Air Compressor, 7.5 HP Double Stage, 160 ltrs Tank Recommended Make: GENIST or Equivalent. |
| 1838 | Steam Boiler, 100 kg Capacity along with Water Softener Make: GENIST or Equivalent. |
| 1839 | Add 1% Cultural Affair and Heritage Maintenance Charges on Rs. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender