Rural Development Government Departments Closing in 6 days TDR #57615034

Tender For Construction Of Rw Rest Shed Building At Rw Division Banspal For The Year 2026-27_Building

Issued by Government Departments · Kendujhar, Odisha
Tender Value
84.03 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
6 days left
EMD
84032
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kendujhar → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Rw Rest Shed Building At Rw Division Banspal For The Year 2026-27_Building

BOQ

Name of Work:- Construction of RW rest shed building at RW Division Banspal for the year 2026-27_building
Sl. No. Item Description
1CIVIL WORK- Earth work in Excavation in hard soil or gravelly soil within 50m intial lead and lifts 1.5 M intial lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site including cost of all labour, T&P and dewatering if required for the work etc. complete as per drawing and Technical specification and as directed by the Engineer-in-Charge.
2Supplying and filling in foundation and plinth with sand, laying in layers, well watered and rammed including cost, conveyance, royalties and taxes of all materials, cost of all labour and T&P etc. complete in all respect as per direction by the Engineer in charge.
3Providing and laying PCC (1:3:6) in foundation and floors using 4cm size crushed stone granite aggregates including laying in layers ramming watering and curing etc. complete including cost conveyance royalties taxes of all materials and cost of all labours T&P etc complete as per the direction of the Engineer in charge.
4Fly ash brick masonry in Foudation of all floors with cement mortar (1:6) using bricks of 25cm size, after immersing Bricks before use with watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge. (Ground Floor)
5Super Structure (Ground Floor)
6Super Structure (First Floor)
7Super Structure (Second Floor)
8Fly ash brick masonry in all floors with cement mortar (1:4) using bricks of 23cm size, after immersing Bricks before use with watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge. (Super Structure)
9Super Structure (First Floor)
10Back Filling of surplus excavated earth at work site by initial lead and lift of 1.50mtr including cost of all labour T&P required for the work etc. complete as directed by Engineer-In-Charge
11R.C.C. work of M.25 in Foundation using 20 mm & down graded size crushed stone granite aggregates including hoisting lowering laying concrete and compacting by using vibrators watering, curing and necessary centring & shuttering for smoth finishing of work excluding steel reinforcement work including cost conveyance royalties taxes of all materials and cost of all labours T&P etc complete as per the direction of the Engineer in charge. (Column Base)
12R.C.C. work of M.25 in Plinth band using 20 mm & down graded size crushed stone granite aggregates including hoisting lowering laying concrete and compacting by using vibrators watering curing and necessary centring & shuttering for smoth finishing of work excluding steel reinforcement work including cost conveyance royalties taxes of all materials and cost of all labours T&P etc complete as per the direction of the Engineer in charge.
13R.C.C. work of M.25 in Column & Beam using 20 mm & down graded size crushed stone granite aggregates including hoisting lowering laying concrete and compacting by using vibrators watering curing and necessary centring & shuttering for smoth finishing of work excluding steel reinforcement work including cost conveyance royalties taxes of all materials and cost of all labours T&P etc complete as per the direction of the Engineer in charge. (Ground Floor)
14Column & Beam ( First Floor)
15Column & Beam (Second Floor)
16RCC Lintel (Ground Floor)
17RCC Lintel (First Floor)
18RCC Lintel (Second Floor)
19R.C.C. work of M.25in Roof slab using 12 mm size crushed stone granite aggregates including hoisting lowering laying concrete and compacting by using vibrators watering curing and necessary centring & shuttering for smoth finishing of work excluding steel reinforcement work including cost conveyance royalties taxes of all materials and cost of all labours T&P etc complete as per the direction of the Engineer in charge. (Ground Floor)
20Roof Slab (First Floor)
21Roof Slab (Second Floor)
22R.C.C. work of M.25in Stair case using 20 mm & down graded size crushed stone granite aggregates including hoisting lowering laying concrete and compacting by using vibrators watering curing and necessary centring & shuttering for smoth finishing of work excluding steel reinforcement work including cost conveyance royalties taxes of all materials and cost of all labours T&P etc complete as per the direction of the Engineer in charge. (Ground Floor)
23Stair case(First Floor)
24R.C.C. work of M.25 in Chajja using 20 mm & down graded size crushed stone granite aggregates including hoisting lowering laying concrete and compacting by using vibrators watering curing and necessary centring & shuttering for smoth finishing of work excluding steel reinforcement work including cost conveyance royalties taxes of all materials and cost of all labours T&P etc complete as per the direction of the Engineer in charge.(Ground Floor)
25Chajja(First Floor)
26Chajja(Second Floor)
27Straightening cutting, bending & binding of bent up or coiled rods confirming to I.S. 432 for Plain and 1785 for Tor steel and binding, tying the grills, hoisting, lowering and placing in proper position including cost, conveyance and taxes of all materials and cost of all labour with all T&P required for the work etc. complete as directed by the Engineer- in-Charge. (Ground Floor)
28MS reinforcement (First Floor)
29MS reinforcement (Second Floor)
30Providing 16 mm thick C.P. with C.M. (1:6) on inside surface of wall with screened and washed sharp sand for mortar and finished smooth including watering and curing with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
31First Floor
32Second Floor
33Providing 12 mm thick C.P. with C.M. (1:6) on outside surface of wall with screened and washed sharp sand for mortar and finished smooth including watering and curing with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. ( Ground Floor)
34First Floor
35Second Floor
36Supplying, fitting, fixing of Vitrified tiles (60cm x 60cm: colour) in floors over 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.
37First Floor
38Supplying, fitting, fixing of Vitrified industrial tiles (30cm x 30cm) in floors over 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.
39First Floor
40Supplying, fitting, fixing of Chequred tiles in floors over 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.
41Supplying, fitting, fixing of Vitrified tiles (60cm x 60cm: colour) in dadoo in all floors over 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. (Ground Floor)
42First Floor
43Supplying, fitting, fixing of Vitrified industrial tiles (30cm x 30cm) in dadoo in all floors over 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. (Ground Floor)
44First Floor
45Supplying and fitting,fixing of Un-plasticised poly vinyl Choloride (UPVC) (FENESTA / NCL VEKA LTD) Cashment window with top fixed -60- series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mm x 2.5 mm for outer frames .75 mm x 60 mm x 2.25for casement window sash profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system structurally reinforced with hot dip galavanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted fitted with 6 mm thick clear toughned glass of SAINT-GOBIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No. per set of sashes and the system is to be installed at the site using anchor fasteners,silicon rubber sealant, easy glazing / deglazing at site etc. including cost and conveyance of all materials,accessories,labour charges,materials and product conforming to ASTM D 638-14 ,EN-477-95 and other applicable codes and standards. (Ground Floor)
46First Floor
47Supplying and fitting,fixing of Un-plasticised poly vinyl Choloride (UPVC) (FENESTA / NCL VEKA LTD)Ventilator / Top Hung -60 series duly manufacured using UPVC reinforced profile of 60 mm x 55 mm x 2.5 mm for outer frames 75 mmx 60 mm x 2.25 mm for casement window sash profile capable of mounting single glazing system , structurally reinforced with hot dip galavanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the widow sash shall be fitted fitted with 6 mm thick clear toughned glass of SAINT-GOBAIN Makke duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No. per set of sashes and the system is to be installed at the site using anchor fasteners,silicon rubber sealant ,easy glazing / deglazing at site etc. including cost and conveyance of all materials,accessories,labour charges,materials and product conforming to ASTM D 638-14 ,EN-477-95 and other applicable codes and standards.(Ground Floor)
48First Floor
49Second Floor
50Dressed seasoned sal wood work framed & fixed in trusses, purlines and frames of doors & windows including cost, conveyance of all materials and cost of labour for fitting, fixing etc.complete as per the instruction of Engineer-in-Charge . (Ground Floor)
51First Floor
52Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete (Ground Floor)
53First Floor
54Supplying of M.S. Grills etc including cost,conveyance of all materials etc.complete as per the instruction of Engineer-in-Charge . (Ground Floor)
55First Floor
56Second Floor
57Supplying of M.S.Doors, M.S. Gate etc including cost, conveyance of all materials etc.complete as per the instruction of Engineer-in-Charge . (Ground Floor)
58First Floor
59Second Floor
60Supplying, fitting and fixing hand railing of Stainless steel of 304 grade using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. required for the complete in all respect as per direction of the Engineer-in-charge. (Ground Floor)
61First Floor
62Providing, Fitting & Fixing of False Ceiling with 12 mm thick gypsum board, Aluminum anodized T section No -3215 with 2ft center to center L section No-1705 up to 15micron on four walls to be fixed by means of steel screw and PVC plug and Aluminum grid 2'-0\\"x2'-0\\" suspended from ceiling including cost, conveyance, royalties and taxes of all materials with cost of all labour, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.(Ground Floor)
63First Floor
64Finishing plastered surfaces with cement washing one coat using cement on inside plaster / concrete surface including cost, conveyance, taxes of all materials, cost of all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
65First Floor
66Second Floor
67Finishing plastered surfaces with cement putty (water based) of approved make on plaster / concrete surface and finishing the surface smooth and even by sand papering to receive paint in walls, at all heights with staging wherever necessary with cost, conveyance, taxes of all materials, cost of all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. (Ground Floor)
68First Floor
69Second Floor
70Finishing inside plastered surfaces with water proofing cement paint of approved shade on old work of one coat in all floors, all heights with staging wherever necessary with cost, conveyance, taxes of all materials, cost of all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
71First Floor
72Painting Two coat with approved weather seal paints of approved colour, shade on wall surface including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge.(Ground Floor)
73First Floor
74Second Floor
75Painting two coats with distemper over one coat of primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. (Ground Floor)
76First Floor
77Second Floor
78Painting two coats with approved enamel paints of approved colour, shade over a coat of primer over new iron work including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge.
79First Floor
80Second Floor
81Painting two coats with approved enamel paints of approved colour, shade over a coat of primer over new Wood work including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. (Door) (Ground Floor)
82First Floor
83Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size crushed stone granite aggregates including laying, watering and curing etc. complete including cost conveyance royalties taxes of all materials and cost of all labours T&P etc complete as per the direction of the Engineer in charge. (First Floor)
84Second Floor
85Providing 6 mm thick C.P. with C.M. (1:4) on inside surface of exposed RCC with sand for mortar and finished smooth to RCC work after closed deep chipping & slurry treatment including watering and curing etc complete with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (Second Floor)
86EI WORK- Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire = Finollex / L & T/ Anchor/ Havels/ V-Guard/ Greatwhite / Polycab) Group A (1.1.1)
87-do- .... Group B (1.1.2)
88-do- .... Group C (1.1.3)
89S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required.2 Modular box with base & cover (1.24.2)
904 Modular box with base & cover (1.24.3)
918 Modular box with base & cover (1.24.5)
9212 Modular box with base & cover (1.24.6)
93S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4)
94S/F of 6 Modular GI box in recess with suitable size of Modular base cover in front including providing and fixing 2 nos 3 pin 5/6 amp. Modular Socket out let & 5/6amp. Modular type switch,connection,painting etc. as required.(2X1.25.1+2X1.25.4)+6 MODULE
95S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required (1.25.3+1.25.5)+4 MODULE BOX
96S/F of computer board (Modular Type) consisting of 3 nos. of 5 amp plug and switch and 6 amp MCB, Indicator complete with wiring on 12 module M.S.box with B.k.cover(1.24.6 + 3 x (1.25.1+ 1.25.4) + 2.6.1)+Indicator
97Wiring for circuit I sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS- 694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required ( Make of wire- Finolex/ / Anchor/ Havels/ V-guard / HPL / L&T / Gratewhite / Polycab). -do- 2x1.5sqmm +1x1.5sqmm ( 1.8.1 )
98-do-2x2.5sqmm +1x1.5sqmm ( 1.8.2 )
99-do- 2x4sqmm +1x1.5sqmm ( 1.8.3 )
100-do- 2x6sqmm +1x2.5sqmm ( 1.8.4 )
101Supply, Installation testing and commissioning of 63 Amp. IC TPN Main Switches (IS13940 part 3/1993) with supply of metal box of following capacity on existing surface/Wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make: HPL / L&T / C&S / Havells / Seimens / RK / Anchor / Havells) (2.15.3)
102250mmx300mmx100mm deep(1.24.13) for fixing 63Amp ICTPN Main switch.
103S/Fof 'B' series SP MCB of 5A to 32 Amp rating 240Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP)(2.6.1)
104S/F of following 12way Double Door and neutral sheet steel MCB DISTRIBUTION BOARD 250v on surface /recess complete with tinned copper bus bar, neutral bar, earth bar, din bar ,detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (except MCB) 2.3.7
105S/F of Call bell/ Buzzer ISI marked sutiable for DC/AC single Phase 230 volts complete as required.(1.30)
106S/F of batten holder BK angle holder ISI marked including connection etc instead of ceiling rose (Make: Cona / Anchor / Havells / Greatwhite / Preeti / HPL) (1.29-1.28)
107Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick and 25mm x 5mm copper tape (1.15Kg. Per Mtr.) 3.5Mtr. & 20mm G.I.pipe medium class 2.7 Mtr. ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc wih charcoal and salt as required. (3.5 + 3.6)
108Providing and fixing 8 SWG copper wire in recess for loop earthing as required. (3.18)
109S/F of 1200mm A.C. Ceiling fan(5star) BLDC with all accessories and connections with out fan regulator (Make:Usha-Energia32/Crompton-Energino HS/Havells-Efficiencia DX/Anchor-Eco Breeze Urban/Orient-Ecotech Supreme/Pollycab-Affeciente Neo)
110S/F of electric step ceiling fan regulater in existing switch box including connection with 1.5sqmm FR PVC insulated single core multistrand copper conductor earthing the regulator as required.(1.38)
111S/F of Fan hok S'type made of 16mm MS rod as per specificationn
112S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells )
113S/F of 18-25 watt LED Tube light fitting compoete with all connection.\ including fixing and all accessories as per direction of Engineer-In-charge (Make: Havels / Phillps / Crompton / Polycab / HPL)
114Supply of instalation, Testing commissioning of 12 Watt. LED bulb
115S/F of 15A modular socket on 2 Modular Metal box for A.C & gyser
116S/F of 32A C series D.P. MCB for A.C (make: Legrand/Anchor/Havels/HPL)
117S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand)
118S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB)
119S/F of 2000 VA Inverter with 2 nos. 180 Ah Tubular battery including trally arrangement (Make: Microtake/ Luminous/Exide)
120wiring to sub main with 1*1.5 mm2 single core multi strand copper wire for inverter wiring (1x1.5mm)
121Supply of 3.5core 35sqmm PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Armoured cable ( MAKE-HAVELLS/polycab/RR Kable/Rhino cable)
122Laying of 35sq mm. 3½ Core cable on surface(5.5.2)
123Laying of 35sq mm. 3½ Core cable in ground(5.1.2)
124Supplying and making end termination with brass compression gland and aluminum lugs for 35sq mm. 3½ Core cable(5.8.21)
125P/F of twin twisted cable 16/0.2 mm. (1.31)
126S/F of 18 Watt Ceiling Light Recessed Mount or Surface Mount(Round or Square )Type(Make Havells/Crompton/Polycab or Equivalent)
127S/F of 100 Amp. T.P.N. Cupper Bus Bar with all connections (Make:-BENLO/Equivalent)
128S/F of oval shaped Portico lamp
129PH WORK - Earth work in all kinds of soil in excavation of foundation trenches within 50 m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding o.30 in depth and as per direction of E.I.C .-- Initial lift up to 1.50m
1302nd depth upt 3.00 mtr
131Supplying all materials, labour T&P and filling in F&P with river sand well watered and rammed including conveyance of all materials to worksite payment of royalty, taxes etc. all complete as per direction of E.I.C.
132Supplying all materials, labour T&P and providing c.c (1:3:6) using 4cm h.g. metal including watering, curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.
133Supplying all materials, labour T&P and providing c.c (1:1.5:3) using 12 mm h.g. chips including watering, curing, coveyance of all materials to worksite payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.
134First Floor
135Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks 25cmx12cmx8cm size having cs. not less than 75kg / cm2 with dimensional tolerance ± 8% in including watering,curing conveyance of all materials to worksite, payment of royalty taxes etc. all complete as per specification and direction of EIC. - In Foundation & Plinth in CM (1:4)
136Supplying all materials, labour, T &P and providing C.C (1:1.5 :3 ) using 12mm h.g. chips for R.C.C. works including hoisting, laying, watering, curing, conveyance of all materials to worksite, curing, conveyance of all materials to worksite, payment of royalty, taxes etc, all complete as per specification and direction of E.I.C.
137Supplying all materials, labour, T&P and providing M.S. reinforcement for R.C.C. works including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite etc. complete as per directio n of E.I.C.
138Supplying all materials, labour, T&P and providing rigid & smooth centering & shuttering for R.C.C.works including false work and dismantling them after casting including conveyance of all material, to worksite, payment of royalty, taxes etc. all complete as per direction of E..I.C.-- R.C.C.Slab
139Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.-- 12mm thick C.P with C.M. (1:4)
14012mm thick C.P with C.M. (1:3)
141Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per specification and direction of E.I.C.
142Supplying all materials, labour, T&P and providing cement flush pointing to brick masonary (1:3) including watering, curing conveyance of all materials to work site, payment of royality, taxes etc. all complete as per direction of E.I.C.
143Supplying all labour, materials T&P and fixing of R.C.C. Baffle wall pre-cast with C.C. (1:1.5:3) using 12 mm b.h.g. chips and fitted to septic tank as per P.H. Specification and direction of E.I.C.
144Supply all materials ,labour,T&P providing fitting and fixing PVC. Tee in wall including filling the necessary with cement concrete (1:2:4) with 12mm size h.g. chips all complete including watering curring,conveyance of all \\"materials to work site .payment of royality .taxes its all complete as per specification and direction of E.I.C.-11OmmXI 10mm X110mm PVC Tee
145Supplying all materials labour T& P and providing 500 x 500 x 100mm thick RCC precast M.H cover in C.C (1:1.5:3) using 12mm h.g. chips and placing the cover on the MH/S tank & finishing smooth all complete as per specification and direction of E.I.C
146Supplying all materials, labour, T&P and making M.S. Step Iron in 12mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the E.I.C.
147Filling F&P with excavated materials, including watering and ramming as per direction of E.I.C.
148Supplying all materials, labour T&P and fixing Ceramic Tiles in floors on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per specification and direction of EIC- Ground Floor
149First Floor
150Supplying all materials, labour T&P and fixing porcelain glazed tiles in dados skirting, on 12mm thick C.P. (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of Engineer-in-Charge.[600x600mm Digital tile]
151First Floor
152Supplying all materials, labour T&P and fixing Granite Tiles on Kitchen Slab on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per specification and direction of EIC- Ground Floor
153Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre's standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C
154Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gel coat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic polyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrene(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reinforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy weight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
155Supplying all materials labour T&P and fixing Wash Down Water Closet(European type W.C. pan) with Integral S or P trap to the floor with wooden plug and C.P.screws including jointing the trap with soil pipe in C.M.(1:1) etc. all complete as per specification & direction of E.I.C 690x360x740mm One Piece EWC with Soft closed Seat and Cover and flush fittings with S Trap (Cera Parry ware Hindware)
156Supplying all materials labour T&P and fitting & fixing SWR ventilating pipes and fittings of the following O.D conforming to ISI No. 13592 BY 1992 to walls with nails bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method as per manufacturer s specification testing, e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C. 110 mm dia PVC SWR Pipes
157110 mm dia PVC SWR P Trap
158110mm dia PVC SWR Nahani trap without Jally
159110 mm dia PVC SWR Door Tee
160110 mm dia PVC SWR Door Bend
161110 mm dia PVC SWR Plain Bend
162110 mm dia PVC SWR Plain Tee
163110 mm dia PVC SWR Offset
164110 mm dia PVC SWR Cowl
165125 mm dia C.P.grating
16675 mm dia SWR Pipes
16775 mm dia PVC SWR Plain bend
16875 mm dia PVC SWR Door bend
16975 mm dia PVC SWR Door Tee
17075 mm dia PVC SWR Offset
171110x75 mm dia PVC R/S
172Supplying all materials, labour T&P and cutting holes through brick/stone masonary walls for taking PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of E.I.C. - 250 mm thick wall
173Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with C.I/M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C.-- 550mm x 400mm WHB with all Fittings with C.P. Waste, PVC Waste Pipe & Connection Pipe. (Neycer/Cerra/ Parry ware/ Hindware)
174Supplying all materials, labour T&P and fixing padestrial for wash basin complete recessed at the back for the reception of pipe and fitting etc. all complete as per specification and direction of E.I.C. (Parrywear/Cerra/Hindware)
175Supplying all materials, labour T&P and fixing mirror of superior glass mounted on 6mm thick plywood sheet and fixed to wooden plugs with C.P screws and washers complete as per P.H specification and direction of E.I.C.-- 600mm x 450mm B.E. Mirror (fixed type)
176Supplying all materials, labour T&P and fixing standard size C.P. towel rail / ring complete with c.p. brass brackets fixed to wooden plugs with c.p screws as per P.H specification and direction of E.I.C. -- 20 mm x 600 mm long C.P Towel rail
177C.P. Towel Ring (St.)
178C.P. Double Coat Hook (Jaquar)
179Supplying all materials, labour T&P and fixing standard size C.P. soap holder complete with c.p brass brackets fixed to wooden plugs with cp screws as per PH specification and direction of E.I.C C.P.Soap Holder.
180Supplying all , labour T&P and fitting, fixing of standard size Glass shelf with CP brass bracket and guard rails complete fixed to wooden plugs with CP screw as per specification and direction of E.I.C -- 450x125mm size Plate Acrylic Shelf
181Supplying all materials, labour T&P and fixing Half Stall Large Wall urinal including the connecting the urinal with waste pipe by means of white lead list with chopped hemp etc. all complete as per direction of E.I.C.-- Half Stall Large Wall Urinal (Standing Urinal) including 32mm dia PVC Waste Pipe with brass coupling nut & 15mm dia PVC inlet connection Pipe [CerraParrywear/Hindware]
18215mm dia C.P. Sprader
183Supplying all materials,labour, T&P and fixing glazed earthen ware Squatting platesize 450 x 350 mm with integral longitudinal flushing pipe including embedding the plate in 25mm thick cement mortar (1:8) laid over PCC (1:5:10) using 40 mm size metal etc all complete as per specification and direction of the E.I.C.- Squatting urinal(ISI mark) (Parry ware/hind ware/Cerra)
184Supplying all materials, labour T&P and costructing gully trap chamber of the following inside size with 8cm thick R.C.C. precast cover slab in c.c. (1:1 1.5:3) using 12 mm size h.g. chips foundation concrete (1:3:6) using 40 mm size h.g. metal on bed and arround trap Fly Ash brick work in c.m. (1:6) in F&P and inside 12mm thick c.p (1:3) finished with a floating coat of neat cement including fixing 100mm size H.C.I gully trap and grating etc. all complete as per approved drawing, specification and direction of E.I.C. Inside size 250mm x 250mm gully trap Chamber
185Supplying all materials, labour T&P and constructing Inspection chamber of the following sizes with c.c (1:3:6) using 40mm size h.g. metal on bed, Ist class Fly Ash brickwork in c.m (1:6), moulding and shaping the channel inside and benching with c.c. (1:11/2:3) using 12mm size h.g. chips 12mm thick c.p. (1:3) with punning to inside cement flush pointing (1:3) to outside R.C.C. cover slab in c.c. (1:11/2:3) using 12 mm size h.g. chips with R.C.C. m.h. cover, e.w. in excavation in all kinds of soil and refilling the cavity arround the chamber including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of the E.I.C. Inside size 760mm x 760mm x 460mm I.C.
186Supplying all materials, labour T&P and constructing man hole chamber of the following sizes with c.c. ( 1:3:6) using 40 mm size h.g. metal on bed Ist class Fly Ash brick work in c.m. (1:6) moulding and shaping the channel inside and benching with c.c (1:11/2:3) using 12mm size h.g. chips, 12 mm thick c.p (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C. cover slab in c.c (1:11/23) using 12 mm size h.g. chips with R.C.C m.h. cover, e.w in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of the E.I.C.- Inside size 910mm x 910 mm x 750 mm
187Inside size 910mm x 910 mm x 910 mm
188Supplying all materials, labour, T&P and laying 110 mm dia SWR pipes of the following O.D conforming to IS No. 13592 and aligning to requisite gradient inside the trench encasing all round of the pipe with c.c (1:3:6) using 4 CM size h.g. metal and CC(1:3:6) with 4CM size h.g. metal in the bed of the trench including lowering the pipes to the bed of the trench, earth excavation in trenches in all kinds of soil, refilling the same in layer of 0.3 mtrs with watering and ramming, removing of surplus earth, testing of sewerage line including use of T&P as per PH Specification and direction of E.I.C.- 110 mm dia SWR Pipe Sewerage line with all round encasing (conforming to IS No. 13592)
189Supplying all materials, labour T&P and constructing soak way pit of the following sizes with dry brick walling form bottom up to invert of inlet pipe and 1st class Fly Ash brickwork in c.m(1:6) for the remaining height at top, 12 mm thick c.p(1:4) inside and outside over masonary brickwork gravel packing in the rear of well steining R.C.C. cover slab in c.c (1:11/2:3) using 12mm size h.g. chips fitted with iron lifting handles including e.w. in open well excavation in stoney earth and refilling the cavity around the pit & painting the iron works, watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of E.I.C.- 1.20mtrs.dia x 2.0mtr.deep soak way pit
190Supplying all materials, labour, T&P and fixing rotational moulded polyethylene cylindrical vertical waterstorage tank confirming to IS 12701- 1996 including cutting hole through the tank and fixing MS tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting the tank and placing the tank to the required position including all complete as per specification and direction of EIC.(including cost of FG Over Head Tank) -- 2000 Ltrs. Capacity F.G.Over Head Tank. (on roof of 1st floor)
191Supplying all materials, labour, T&P and Construction of masonary stagging with providing 1st class Fly Ash brick work in c.m, (1:6) of 0.46m. height in staging and in circular protection wall to support the tank in roof of ground floor using 25cm x 12cm x 8cm size Fly Ash bricks having crushing strength not less than 75 kg/cm2 12mm thick c.p.(1:4) over brick work, R.C.C. Slab of size 1.60mtr xl.60mtr x0.l0mtr thick, R.C.C. beam of size 0.25m x 0.30m and 2.60m average length in c.c.(1:1.5:3) using 12mm size h.g. chips including centering and shuttering, watering, curing conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C -- For 2000 Ltr. Capacity Over Head Tank(on roof of Gr. floor)
192Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC Pipes conforming to ASTM-D-1785/89(sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C - 20 mm dia C-PVC Pipe [Internal]
19325 mm dia C-PVC Pipe [Internal]
19425 mm dia PVC (ASTM) Pipe) [External]
19532 mm dia PVC (ASTM) Pipe) [External]
19632 mm dia HDPE Pipe [External Including E/W]
19732 mm dia HDPE Pipe [Inside Tube Well]
198Supplying all materials,labourT&P and cutting holes through brick/stone masonary walls for taking water supply pipes and fittings including making good the damages etc.all complete as per P.H specification and direction of Engineer in charge
199Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. .
200Supplying ail materials,labour,T&P and fitting & fixing brass/C.P fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H specification and direction of E.I.C.- 15mm dia. C.P Bibcock (long body) [Jaquar]
20120mm dia.C.P Conceal stopcock [Jaquar]
20215mm dia.C.P Angle stopcock [Jaquar]
20315mm dia.C.P Pillar cock Swan Neck [Jaquar]
20415mm CP Two Way Bib cock [Jaquar]
20515mm dia C.P. Health Faucet [Jaquar]
20615 mm dia C .P Wall Mixture 3-in-1[Jaquar]
20715mm dia C.P. Telephonic Shower with Flexible Tube & hook [Jaquar]
20815mm dia C.P Extension piece.
20925mm dia. PVC Ball valve [Metal Ball]
21032mm dia. PVC Ball valve [Metal Ball]
211Supplying all materials, labour, T&P and fitting and fixing C.P. shower with 15 mm or 20 mm inlet with C. P. shower arm including polishing all complete as per P.H. specification and direction of E.I.C.
212125x100mm dia Tube Well through DTH Method Labour for drilling a perfectly vertical bore holes of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilled rig (650cmf/200psi) as required to suit the site condition as per the direction of E.I.C. including use of own rig with its accessories, tools and plants and consumable etc. for finished bore suitable for lowering of 125mm dia PVC/GI Pipes for housing filled with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/PVC) casing pipes it required to prevent collapse of overburden portion is to be provided by the contractor including lowering and withdrawing after completion of tubewell.-Drilling of 125mm dia bore
213Lowering the following sizes GI/PVC Pipes with or without slotted pipes as per the necessity from gravel level upto 30 mtr depth and fitted and fixed up in perfectly vertical position including cutting and threading pipe and slotted pipes and supplying and fixing all jointing materials tools and plants etc. completes and keeping the top of the casing pipes threaded including plugging tubewell to prevent entryof foreign materials. From above- Lowering of 125mm dia PVC Pipe
214Cost of 125mm dia PVC Pipe [ASTM-D-1785/2021-Schedule-80)
215Cleaning and developing the tube wells with their own compressor continuously jworked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of EIC
216Supplying all materisl, labour, T & P and withdrawing casing pipe from the unsuccessful bore and depositing in the departmental store in good condition.
217Supplying of ISI Mark 1.00 HP Single Phase Vertical Submersible Pump Set with Discharge of 900-1000 liter/hour and a head of 50-60 mtr of reputed make like KSB/Texmo & Equivalent including all cost, conveyance and taxes etc. all complete as per direction of Engineer-in-charage.
218Supplying all labour, T&P and fitting and fixing of 1.00 HP Single phase vertical Submersible Pump Set with commissioning and testing etc. all complete as per direction of Engineer-in-charge.
219Supplying and fitting and fixing of ISI Mark DOL Starter of reputed make like BCH or Equivalent for 1.00 HP Single Phase Submersible Pump including all cost, conveyance and taxes etc. all complete as per direction of Engineer-in-charge.
220Supplying and fitting and fixing of three core flat cable (2.5mm2) of ISI Make of reputed company line BCH/Finolex or Equivalent and connecting the pump and starter including all cost, conveyance and taxes etc. all complete as per direction of EIC
221Supplying and fitting & fixing of Plastic rope, M.S. Well Cover, M.S. Clamp, Stainless Steel Short piece, Bend & Socket including all const, conveyance and taxes etc. all complete as per direction of engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57615034
AUTHORITY Government Departments
TENDER VALUE 84.03 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Construction Of Rw Rest Shed Building At Rw Division Banspal For The Year 2026-27_Building
Basic Detail
Tender No Building Online NCB No.07
Bidding Type Tender
Location
City Kendujhar
State Odisha
Key Dates
Publish Date 21 Sep 2026
Submission Date 29 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 84.03 Lakhs
Tender Fee 10000
EMD 84032
Exemption Available
Document List
978f73f9-2c1f-42e8-9c06-a6d6f8739cc6.html
BOQ_610233.xls
Tendernotice_1 (20).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

978f73f9-2c1f-42e8-9c06-a6d6f8739cc6.html

xls

BOQ_610233.xls

pdf

Tendernotice_1 (20).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender