Tender For Repair Maintenance Of Internal Security Lights For Wsa Area, Tropo And Other Various Location Under Ge (Af) Jamnagar No. 1
Tender Value
30 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
15 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Maintenance Of Internal Security Lights For Wsa Area, Tropo And Other Various Location Under Ge (Af) Jamnagar No. 1
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting & Taking out LT underground cable from trenches etc., aluminium conductor of size 16 sqmm 4 core including cable cover, Complete all as specified and directed by Engineer-in-Charge. Note- Servicable Cable cover shall be sorted out for reused. |
| 2 | Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 25 sqmm 3.5 core including cable cover, Complete all as specified and directed by Engineer-in-Charge. Note- Servicable Cable cover shall be sorted out for reused. |
| 3 | Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing, Complete all as specified and directed by Engineer-in-Charge. |
| 4 | Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing, Complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc., Complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc., Complete all as specified and directed by Engineer-in-Charge. |
| 7 | Disconnecting & Taking out LT cable from trenches/ pole etc, aluminium conductor of size 10 sqmm 2 /4 core including fixing arrangeement, Complete all as specified and directed by Engineer-in-Charge. Note- Servicable Cable cover shall be sorted out for reused. |
| 8 | Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 10 Sqmm 2/4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing, Complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc., Complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply, jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 10/16/25 Sqmm suitable for 2/3.5/ 4 core, Complete all as specified and directed by Engineer-in-Charge. |
| 11 | Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth and getting out in soft / loose soil, Complete all as specified and directed by Engineer-in-Charge. |
| 12 | Returning filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick using excavated soil, Complete all as specified and directed by Engineer-in-Charge. |
| 13 | Removing excavated soil to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, Complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply and filling Local sand cushioning, with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable, complete all as specified and directed by Engineer-in-Charge.NOTE :- Punned thickness of sand will be measured and paid. |
| 15 | Laying only PCC cable cover for LT UG cable, of any description, Complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & laying ISI marked & conforming to IS - 5820 - 1970 un-reinforced precast concrete cable cover Class LV, Type I, flat size 250mm X 150mm X 40mm in trenches as protection to LT UG cable, Complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and Fixing in replacement Tubes 40mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, Complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and Fixing in replacement Tubes 50mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, Complete all as specified and directed by Engineer-in-Charge. |
| 19 | Taking down carefully street light/flood light fittings of any make and capacity, opening for examination & for replacement unservicable spare part and Refixing the same in position after necessary replacement of drivers and minor spare parts at the same/other location, including any UG cable fault it will be rectified or replaced accordingly and necessary T&P like ladder/Boom Vehicle, tools etc as required for taking down & refixing of street light/flood light complete. Note :- Rate Quoted by the tender is not inclusive of supply of drivers. The supply only of drivers where repaired shall be measured and paid separately under respective items. |
| 20 | Supply only Led diver for Street light/flood light fitting of following capacity/sizes |
| 21 | LED driver for light fitting of capacity 200-250 watt. |
| 22 | LED driver for light fitting of capacity 120-160 watt. |
| 23 | LED driver for light fitting of capacity 90-110 watt. |
| 24 | LED driver for light fitting of capacity 70-80 watt. |
| 25 | LED driver for light fitting of capacity 45-60 watt. |
| 26 | Supply and fixing in replacement of LED Street Light fitting 120 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fixing in replacement of LED Street Light fitting 90 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply and fixing in replacement of LED Street Light fitting 70 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and fixing in replacement of LED flood Light fitting 120 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fixing in replacement of LED flood Light fitting 200 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply and fixing in replacement of LED flood Light fitting 240 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and fixing in replacement of 4 Pole 75/80 Amp power contactor, AC 3 rating, fixed in existing panel & connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fixing in replacement of 4 Pole 32 to 40 Amp power contactor, AC 3 rating, fixed in existing panel & connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and fixing in replacement Power saver and user friendly analog clock timer to set street light ON/OFF timing complete with stringment international test standards, Complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material & Labour in replacement for sub main wiring with 2 run single core multistranded copper conductor cable, of size 1.5 Sqmm each, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through including PVC conduit and including one run single core multistranded copper conductor cable, of size 1.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, Complete all as specified and directed by Engineer-in-Charge. Note: 2 Runs of main cable and one run earth wire will be measured as one unit for payment. |
| 36 | Supply and fixing in replacement of 20mm bore UPVC pipe medium grade inclusive of fitting etc fixed on pole / wall with mild steel clamps made out of MS Flat 25 x 6mm including, nuts, bolts at the interval of 1metre complete including two coat of synthetic enamel paint over a coat of red oxide primer, Complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fixing in replacement of Sheet moulding compound (SMC) junction box of size 350mm x 250mm x 150mm, comprising three phase aluminium bus bar and one No MCB SP, 06 Amps \\"C\\" type, fixed on pole with mild steel clamps, nuts and bolts, Complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fixing IN REPAIR for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised iron strip 32X6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 40 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of SSR Part-I 2009, Complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board size of 900mm 900mm x 450mm, confirming to IS 5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 6 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old panel all as specified and directed & Consisting of the following equipment's:- (a) MCCB 415 Volt 120 Amps, 4 Pole, 16KA-01 (Incoming). (b) MCB 415 Volt 63 Amps, 4 Pole 10 KA-02 Nos (Outgoing) (c) Solid aluminium bus bar 200 Amps for 3 Phase and neutral supply. (d) Digital Volt meter 0- 500V - 01 with selector switch. (e) Digital Ammeter 0- 30 Amps - 01 with CTs & selector switch . (f) Timer switch of suitable capacity. (g) Power Contactor MNX70. (h) Auto mannual switch - 0 1 No. (j) R,Y,B ,on and off indidcation. (k) 2P 6A MCB-1 Nos. (l) On/off push button. (m) Mounting arrangement for 2 MCB for future Expansions. (n) Selector switch for voltmeter,ammeter 3 postion -2Nos. |
| 40 | Supply and fixing in replacement of LED Bollard garden light fitting 10 watt height 3 feet ,IP 65/IK 10 protection, with base plate and necessary foundation and connected electric and PCC works, Complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and fixing in replacement of LED Post-Top lantern 18 watt, IP 65 energy saving, environmental friendly, long life aesthtically designed with symmentrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source ,suitable for pole size and making arrangements, PCC work, electric connections, Complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor twin core 6 sqmm, weather proof,flat or circular served with inner sheathing of PVC tape and overall PVC sheathed in service connections, Complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor twin core 10 sqmm, weather proof,flat or circular served with inner sheathing of PVC tape and overall PVC sheathed in service connections, Complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and Erect in replacement Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 Note:- (a) Rate quated is inclusive of following(i) Excavation&Earthwork ,Returning filling and Removal of soil (ii) PCC (1:4:8) type D2 (using 40 mm aggregrate) in base & foundations as per specification (iii) Coping (1:2:4) type b1 as per specification.(iv) PCC (1:3:6) type C2 as per specification. |
| 45 | Supply and fix in replacement MCBs TPN pole, 40-63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board, complete including connecting, Complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply and fixing in replacement of mounting bracket for street light fittings made out of GI pipe light grade 40 mm dia upto 1.5 m length bent to shape incl fixing arrangement with neccassary clamps, bolts, nuts, washers etc ., Complete all as specified and directed by Engineer-in-Charge. |
| 47 | Material and labour for Extending/Repairing of damaged Coping of Poles (Steel/prestressed) by PCC(1:2:4) above/below ground level up to size of (0.6x0.6x.45) Metre, Complete all as specified and directed by Engineer-in-Charge. |
| 48 | Material and labour for cleaning of vegetation/shrubs on pole from bottom to top and upto 2m surrounding the pole including cutting/prunning of tree banches, Complete all as specified and directed by Engineer-in-Charge. |
| 49 | Material and labour for cleaning, refixing and alignment of hanging of existing SMC box of any size with necessary fixing arrangment of nut/bolts, clamps, saddle etc., Complete all as specified and directed by Engineer-in-Charge. |
| 50 | Material and labour for cutting of PCC/hard standing /WBM road not exceeding 20cm in width not exceeding 30cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surface by using old and new material i.e bitumen/PCC (1:3:6) type C-1, Complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material and labour for day to day complain of checking of time panel, Pole box, MCB,loose wire connection of any type of fault and rectified the same and including necessary T&P like ladder/Boom Vehicle,tools etc as required, Complete all as specified and directed by Engineer-in-Charge. Note- Any types of item required for reparing/replacement shall be measured separatly under respective items. |
| 52 | Note:(a) One electrician and one helper should be available for attending day to day complaints on all days including/Sunday and holiday (b) Indls should be in possession of all required tools for rectification of complaints . (c) Labour charges and cost of reqired tools is deemed to be included in the rate above quoted. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender