Tender For Supply, Survey, Erection, Testing And Commissioning Including Creation Of 3 X 25 Kva Sub Stn Along With Ht/Lt Network At Lakshminagar Phagmullah, Ramala Paristan And St Basti Baliot 2 X 63 Kva Sub Stn Along With Ht/Lt Network At Upper Char
Tender Overview
Project Description
Tender for Supply, Survey, Erection, Testing And Commissioning Including Creation Of 3 X 25 Kva Sub Stn Along With Ht/Lt Network At Lakshminagar Phagmullah, Ramala Paristan And St Basti Baliot 2 X 63 Kva Sub Stn Along With Ht/Lt Network At Upper Charihalan And Bhata Traq Under The Jurisdiction Of Ed Jpdcl Batote (Scheme Code Pddss2526100771)
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Survey, Erection, Testing and Commissioning including Creation Of 25 KVA Sub Stations at Laxminagar Phagmullah under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 2 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto dateamendment |
| 3 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 4 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 5 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 6 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 7 | 9 Mtr. Long Pole( ST-410 SP33) |
| 8 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 9 | GI Channel/Angle/Flat of sizes including clamps |
| 10 | Galvinized Nuts and Bolts. |
| 11 | 32/63 amps TPN Switch Disconnector Fuse set |
| 12 | Cement Bottoming 1:2:4 mix as per REC Standards 5cum/pole |
| 13 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 14 | Laying of HT line on 9 mtr ST Poles along with Conductor and allied material for Creation Of 25 KVA Sub Stations at Laxminagar Phagmullah under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 15 | 9 Mtr. Long Pole( ST-410 SP33) |
| 16 | GI V cross-arm with top Bracket including clamp |
| 17 | GI Channel X-arm including clamps and braces |
| 18 | 30 mm² ACSR Conductor |
| 19 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 20 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 21 | Galvanized Nuts and Bolts |
| 22 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 23 | Danger Plates with clamps |
| 24 | Anti Climbing Devices |
| 25 | Cement Bottoming 1:2:4 mix as per REC Standards .5cum/pole |
| 26 | Aluminium Paint |
| 27 | Laying of LT line on 8 mtr ST Poles along with Conductor and allied material for Creation Of 25 KVA Sub Stations atLaxminagar Phagmullah under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 28 | 8 Mtr. Long Pole(ST-410 SP15) |
| 29 | 30 mm² ACSR Weasel Conductor |
| 30 | 16 KN Polymer Shackle Insulator |
| 31 | Clamp for Shackle Insulator |
| 32 | Galvanized Nuts and Bolts |
| 33 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 34 | Aluminium Paint |
| 35 | Supply, Survey, Erection, Testing and Commissioning including Creation Of 25 KVA Sub Stations at Ramala Paristan under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 36 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto dateamendment |
| 37 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 38 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 39 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 40 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 41 | 9 Mtr. Long Pole( ST-410 SP33) |
| 42 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 43 | GI Channel/Angle/Flat of sizes including clamps |
| 44 | Galvinized Nuts and Bolts. |
| 45 | 32/63 amps TPN Switch Disconnector Fuse set |
| 46 | Cement Bottoming 1:2:4 mix as per REC Standards 5cum/pole |
| 47 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 48 | Laying of HT line on 9 mtr ST Poles along with Conductor and allied material for Creation Of 25 KVA Sub Stations at Ramala Paristanunder the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 49 | 9 Mtr. Long Pole( ST-410 SP33) |
| 50 | GI V cross-arm with top Bracket including clamp |
| 51 | GI Channel X-arm including clamps and braces |
| 52 | 30 mm² ACSR Conductor |
| 53 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 54 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 55 | Galvanized Nuts and Bolts |
| 56 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 57 | Danger Plates with clamps |
| 58 | Anti Climbing Devices |
| 59 | Cement Bottoming 1:2:4 mix as per REC Standards 5cum/pole |
| 60 | Aluminium Paint |
| 61 | Laying of LT line on 8 mtr ST Poles along with Conductor and allied material for Creation Of 25 KVA Sub Station at Ramala paristan under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 62 | 8 Mtr. Long Pole(ST-410 SP15) |
| 63 | 30 mm² ACSR Weasel Conductor |
| 64 | 16 KN Polymer Shackle Insulator |
| 65 | Clamp for Shackle Insulator |
| 66 | Galvanized Nuts and Bolts |
| 67 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 68 | Aluminium Paint |
| 69 | Supply, Survey, Erection, Testing and Commissioning including Creation Of 25 KVA Sub Stations at ST basti Baliot under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 70 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto dateamendment |
| 71 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 72 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 73 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 74 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 75 | 9 Mtr. Long Pole( ST-410 SP33) |
| 76 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 77 | GI Channel/Angle/Flat of sizes including clamps |
| 78 | Galvinized Nuts and Bolts. |
| 79 | 32/63 amps TPN Switch Disconnector Fuse set |
| 80 | Cement Bottoming 1:2:4 mix as per REC Standards 5cum/pole |
| 81 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 82 | Laying of HT line on 9 mtr ST Poles along with Conductor and allied material for Creation Of 25 KVA Sub Stations at ST basti Baliot under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 83 | 9 Mtr. Long Pole( ST-410 SP33) |
| 84 | GI V cross-arm with top Bracket including clamp |
| 85 | GI Channel X-arm including clamps and braces |
| 86 | 30 mm² ACSR Conductor |
| 87 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 88 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 89 | Galvanized Nuts and Bolts |
| 90 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 91 | Danger Plates with clamps |
| 92 | Anti Climbing Devices |
| 93 | Cement Bottoming 1:2:4 mix as per REC Standards 5cum/pole |
| 94 | Aluminium Paint |
| 95 | Laying of LT line on 8 mtr ST Poles along with Conductor and allied material for Creation Of 25 KVA Sub Stationsat ST basti Baliot under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 96 | 8 Mtr. Long Pole(ST-410 SP15) |
| 97 | 30 mm² ACSR Weasel Conductor |
| 98 | 16 KN Polymer Shackle Insulator |
| 99 | Clamp for Shackle Insulator |
| 100 | Galvanized Nuts and Bolts |
| 101 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 102 | Aluminium Paint |
| 103 | Supply, Survey, Erection, Testing and Commissioning including Creation Of 63 KVA Sub Stations at W.No 7 Champa under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 104 | 63 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings |
| 105 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 106 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 107 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 108 | 120 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type |
| 109 | 9 Mtr. Long Pole( ST-410 SP33) |
| 110 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 111 | GI Channel/Angle/Flat of sizes including clamps |
| 112 | Galvinized Nuts and Bolts. |
| 113 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 114 | 11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm |
| 115 | Galvanized stay set with 50*8 mm stay clamp, guy insulator(2 nos), anchor plate (200*6mm), nuts-bolts, 2 Nos turn buckets, 1.8m long, 16 mm diameter solid GS stay rod & 7/15 mm dia GI strandard wire complete. |
| 116 | Wedge connctors/PG Clamps |
| 117 | Danger plates with clamps |
| 118 | GI Barbed wire for Anti Climbing |
| 119 | LT Distribution Box for 63 kVA DTR with MCCB for incomer & Switch Fuse Units for Outgoing Circuits |
| 120 | Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole |
| 121 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 122 | Sundry Item like aluminium lugs, jumpers, binding tape. |
| 123 | Laying of HT line on 9 mtr ST Poles along with Conductor and allied material for Creation Of 63 KVA Sub Stations at W.No 7 Champa under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 124 | 9 Mtr. Long Pole( ST-410 SP33) |
| 125 | GI V cross-arm with top Bracket including clamp |
| 126 | GI Channel X-arm including clamps and braces |
| 127 | 30 mm² ACSR Conductor |
| 128 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 129 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 130 | Galvanized Nuts and Bolts |
| 131 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 132 | Danger Plates with clamps |
| 133 | Anti Climbing Devices |
| 134 | Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole |
| 135 | Aluminium Paint |
| 136 | Laying of LT line on 8 mtr ST Poles along with Conductor and allied material for Creation Of 63 KVA Sub Stations at W.No 7 Champa under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2526100771) |
| 137 | 8 Mtr. Long Pole(ST-410 SP15) |
| 138 | ACSR Weasel |
| 139 | Shackle Insulator |
| 140 | M Clamp |
| 141 | Galvanized Nuts and Bolts |
| 142 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 143 | Danger Plates with clamps |
| 144 | Anti Climbing Devices |
| 145 | Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole |
| 146 | Aluminium Paint Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender