Tender For Upgradation Of Rcd Jhullas,Tehsil Haveli.District Poonch.Civil Work Aaa:- Director Department Of Animal Husbandry Jammu Order No:-49-Dahj Of 2025-26 Dated:- 21-08-2025
Tender Value
96.31 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
10 days left
EMD
1.92 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Upgradation Of Rcd Jhullas,Tehsil Haveli.District Poonch.Civil Work Aaa:- Director Department Of Animal Husbandry Jammu Order No:-49-Dahj Of 2025-26 Dated:- 21-08-2025
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m Sq. on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 4 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. |
| 5 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 11 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 5.3.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with:1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 17 | Foundations, footings, bases of columns etc. for mass concrete. |
| 18 | Columns, pillars, piers, abutments, posts and struts. |
| 19 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 20 | Suspended floors, roofs, landings, balconies and access platforms. |
| 21 | Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 22 | Stairs (excluding landings) except spiral staircases. |
| 23 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :1.4 Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 24 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 25 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level :Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 26 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 27 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. |
| 28 | Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level including curingcomplete with:Cement mortar 1:6 (1 Cement : 6 coarse Sand).2nd Sort |
| 29 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 30 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Sal wood |
| 31 | Providing and fixing factory made UPVC door frame made of UPVC extruded,section having an overall dimension, as below (tolerance+/-1mm with wall thickness 2.0mm +/-0.2mm, corners of the door frame to be joined withgalvanized brackets and stainless steel screws, joint mitred and plastic welded.The hinges side vertical of the frames reinforced by galvanized MS tube of size19x19mm and 1mm +/-0.1mm wall thickness and three numbers stainless steel hinges fixed to the frame complete as per manufacturers’ specifications anddirection of engineer-in-charge).Extruded section profile size 42x50mm |
| 32 | Providing and fixing to existing door frames30mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 60x30mm and wall thickness 2mm +/-0.2mm with inbuilt decorative moulding edging on one sides. The styles and rails mitred and joined at the corners and by means of MS galvanized/plastic brackets of size 75x220mm having wall thickness 1.0mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanized MS tube ofsize 25x20mm and 1mm +/-0.1mm wall thickness. The lock rail made up of ‘H’ section, a UPVC hollow section of size 100x30mm and 2mm +/-0.2mm wall thickness fixed to the shutter styles by means of plastic/galvanized MS ‘U’cleats. The shutter frame filled with UPVC multi-chambered single panels of size not less than 620mm, having over- all thickness of 20mm and 1mm +/-0.1mm wall thickness. The pannels filled vertically and tie bar at two places by inserting horizontally 6mm galvanized MS rod and fastened with nuts and washers, complete as per manufacturers’ specification and direction of engineer-in-charge |
| 33 | Providing and fixing 35mm thick panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).First class kail wood |
| 34 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Float glass panes5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) |
| 35 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia wire and 1.4 mm wide aperture with matching wood beading |
| 36 | Providing and fixing 35mm thick ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st classhard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 37 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 38 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc. |
| 39 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 40 | Providing and fixing bright finished brass door latch with necessary screws etc.complete. :300x16x5 mm |
| 41 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. :250x10 mm |
| 42 | Providing and fixing bright finished brass handles with screws etc. complete :125 mm |
| 43 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 44 | Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Riveted and bolted |
| 45 | Steel work welded in built up sections/framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 46 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying primin |
| 47 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensilesteel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 48 | Providing and fixing ball bearing for rolling shutters. |
| 49 | Providing and laying matt finished vitrified tile of specified size having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.300x300x9.8 mm |
| 50 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of tile 600x600 mm |
| 51 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement basedhigh polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of tile 600x600 mm |
| 52 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent |
| 53 | Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.8mm thick (mirror polished and machine cut edges)Granite stone of any colour and shade |
| 54 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work |
| 55 | 12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand) |
| 56 | 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 fine sand) |
| 57 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 58 | Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick |
| 59 | Applying priming coats with primer of approved brand and manufacture,having low VOC (Volatile Organic Compound) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter |
| 60 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required,to achieve even shade and colour.Two coats |
| 61 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 62 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 63 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix) |
| 64 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 65 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:In cement mortar |
| 66 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead: area of 3 sqm. and below |
| 67 | Dismantling Dry stone pitching in aprons, drains, etc. including stacking of serviceable material & disposal of unserviceable material, stacking /disposal lead upto 100 meters. |
| 68 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 69 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 70 | Providing and fixing inagurataion stone of granite(Size 3'-0\\"x2'-0\\") incl.engraving writing and fixing in wall including construction ofPedestal complete job |
| 71 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 72 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs,balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including.laying glass fibre cloth of approved quality in top layer of plaster andfinally finishing the surface with trowel with neat cement slurry andmaking pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for aminimum period of two weeks for curing and for final test. All aboveoperations to be done in order and as directed and specified by Engineerin-charge.23.7.1 With average thickness of 120mm and minimum thickness atkhurra as 65 mm |
| 73 | Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires |
| 74 | Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683)suitable for Class A/B/C Type Fires . |
| 75 | Roller blinds: Providing and fixing roller blinds comprising approved quality sunscreen/blackout polyester fabric of approved colour, texture and pattern, complete with extruded aluminium roller tube, aluminium bottom rail, heavy-duty clutch mechanism, continuous bead-chain operation, powder-coated/aluminium mounting brackets, end caps, chain tensioner and all necessary screws, fasteners and accessories, including measurement, cutting, fabrication and installation, complete in all respects as per manufacturer's specifications, approved sample and directions of Engineer-in-Charge.Premium/heavy-duty blackout blind |
| 76 | Supply and fixing in position 3 seater benche, having legs and handle of cast iron, and seat with back rest in ms RHS. Duly painted with primer and then with anamel paint. Approximate dimension of the bench be 6' x 2' x 2'-6\\". Inclusive of making pcc base for installtion of the bench with nut and screw. All inclusive as per direction of Engineer in Charge. |
| 77 | Providing Retro-reflective regulatory sign board of size 900mm diameter made out of 2mm thick aluminum sheet, face to be fully covered with high intensity encapsulated lens type retro-reflective sheeting as approved by Engineer-in-charge. Letter, symbols, borders, etc. will be as per IRC:67 with required colour scheme on the boards and with the high intensity grade A. the aluminum sheet to be riveted to M.S. frame of angle iron of size 40x40x4mm. The boards will be fixed to 1 No. 50x50mm square post made of M.S. angle 50x50x4mm, 4m long welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminum sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per directions of Engineer-in-charge. |
| 78 | Carriage of material by M.T incl loading/unloading & stacking complete |
| 79 | Building Rubbish avg. lead 05 km by MT |
| 80 | Sand for Brick work and Plaster avg. lead 210 km by MT |
| 81 | Sand /Stone agg. below 40 mm nominal size avg. lead 11km by MT |
| 82 | Stone agg. above 40 mm nominal size avg. lead 11 km by MT |
| 83 | Bricks for an avg. lead 210 km by MT |
| 84 | PLUMBING SYSTEMSUB HEAD -I :SANITARY FIXTURES |
| 85 | Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid , 10 liter low level white vitreous chinaflushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. |
| 86 | Providing and fixing white vitreous china water closet squatting pan (Indian type)Orissa pattern W.C. pan of size 580x440 mm |
| 87 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 88 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 89 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx size 610x390x370mm having pre & post flusing with water (250ml& 500ml consumption) having water inlet from back side including fixing to wall with suitable brackets all as per manufactures specification and direction of Engineer-in-charge. |
| 90 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Semi rigid pipe. 40 mm dia |
| 91 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.Rectangular shape 1500x450 mm |
| 92 | Providing and fixing toilet paper holder. C.P. brass |
| 93 | Providing and fixing PTMT soap dish holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106gms. |
| 94 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighingnot less than 88 gms. |
| 95 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. Of quality and make as approved by Engineer - in - charge. |
| 96 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 97 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 98 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 99 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 100 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 101 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet.150 mm diameter |
| 102 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes |
| 103 | 75 mm diametre |
| 104 | 110 mm diametre |
| 105 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Coupler |
| 106 | 75 mm |
| 107 | 110 mm |
| 108 | Bend 87.5° |
| 109 | 75 mm bend |
| 110 | 110 mm bend |
| 111 | Shoe (plain) |
| 112 | 75 mm shoe |
| 113 | 110 mm shoe |
| 114 | Providing and fixing of Floor Traps 110mm with double chrome plated cover one grated and one closed and all other fitting required.Makes:-Astral/SFMC/Finolex |
| 115 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 116 | Supply installation of PVC Gully Trap of size 110mm |
| 117 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 118 | 15mm nominal outer dia pipes. |
| 119 | 20mm nominal outer dia pipes. |
| 120 | 25mm nominal outer dia pipes. |
| 121 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.External work including trenching, refilling etc. |
| 122 | 40mm nominal outer dia pipes. |
| 123 | Providing and Fixing unplasticised PVC connection pipe with brass unions.45cm length.15mm nominal bore |
| 124 | Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay (non modular) bricks |
| 125 | Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less that 16kg/sqcm with threaded/flanged joints complete with nuts bolts,gaskets washers etc |
| 126 | 25mm Diameter |
| 127 | 32mm Diameter |
| 128 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design. |
| 129 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 130 | Supply installation testing and commissing of water pump with a Discharge of 6.0 Cu.m/hr @ Head of 45 Meters complete with all accessories including header pipes allied materials and control panels |
| 131 | UG WATER TANK AND SEPTIC TANK |
| 132 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m Sq. on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 133 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : |
| 134 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 135 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 136 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 137 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 138 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 5.3.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 139 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 140 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 141 | Foundations, footings, bases of columns etc. for mass concrete. |
| 142 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 143 | Suspended floors, roofs, landings, balconies and access platforms. |
| 144 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :1.4 Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 145 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level :Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 146 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. |
| 147 | 12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand) |
| 148 | Carriage of material by M.T incl loading/unloading & stacking complete |
| 149 | Sand /Stone agg. below 40 mm nominal size avg. lead 11km by MT |
| 150 | Stone agg. above 40 mm nominal size avg. lead 11 km by MT |
| 151 | Bricks for an avg. lead 210 km by MT Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender