Water Resources and Irrigation Government Departments Closing in 8 days TDR #57613344

Tender For Construction Of One Classroom, One Library Room, And A Boundary Wall At Government Primary School Ratanfarm No. 1 (Sitarganj), An Utkrisht Vidyalaya (Model School).

Issued by Government Departments · Udam Singh Nagar, Uttarakhand
Tender Value
29.51 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
8 days left
EMD
59100
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udam Singh Nagar → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of One Classroom, One Library Room, And A Boundary Wall At Government Primary School Ratanfarm No. 1 (Sitarganj), An Utkrisht Vidyalaya (Model School).

BOQ

Name of Work:- Construction of one classroom, one library room, and a boundary wall at Government Primary School Ratanfarm No. 1 (Sitarganj), an Utkrisht Vidyalaya (Model School).
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
2Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
3Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
4Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
7Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
8Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
9Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
10Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
11Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
12Foundations, footings, bases of columns, etc. for mass concrete
13Lintels, beams, plinth beams, girders, bressumers and cantilevers
14Columns, Pillars, Piers, Abutments, Posts and Struts
15Suspended floors, roofs, landings, balconies and access platform
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
17Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
18Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
19Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb
20Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
21Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
22Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor.With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
23Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., Size of Tile 600x600 mm
24Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
256 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
2612 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
2715 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
28Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
29Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work
30Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
31Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
32Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
33S/F of sign board including all cost.
34Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
35Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm
36Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm Shoe
37Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 110 mm dia Pipe
38Wiring for light point/ fan point/ exhaust fan point/ call bel point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
39Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
40Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
41Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Modules (75 mm X 75 mm)
42Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
43Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outle
44Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
45Supplying and fixing suitable size GI box with modular plate and cover in front on surfaceor on recss, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
46Supplying and fixing brass batten/ angle holder including connection etc. as required.
47Installation, testing and commissioning of pre wired, fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
48Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
49Supplying and fixing following way,single pole and neautral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way, Double Door
50Supplying and fixing following rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections , testing and commissioning etc. as required. 40 Amps
51Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
52Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
53Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required(Jointing shall be done by overlapping and with 2. sets of G.I. nut bolt & spring washer spaced at 50mm)
54Supplying And Making end Terminal with brass comprasion gland and aluminium lugs for following size of PVC Insulated and PVC Sheeted/XLPE aluminium conductor Cable of 1.1KV grade as required. 2 x 6 sq. mm (19 mm)
55Supply of AC 230/250 Volts, 50 Hz energy efficient ceiling fan with Standard down rod, blades,3 nos.caps Model- ES 50 (1200 MM Sweep) etc. complete, in all aspects as per direction of Engineer in charge. 1200 mm Sweep
56Supply and fixing on LED Tube light 1200 mm 20 W 865 T8 IP20, Lumen Output-1600, 3000,4000, 6500K ceiling mounted LED batten (E-Lite LED TRIYACA) extruded aluminium heat sink provided for efficient heat deissipation 7 & integrated electronic driver ( 1x20 W LED Double 6500K) complete in all aspects as per direction of Engineer in charge.
57SUPPLY OF LED Glass Bulb B22, 15 W, 600K / 4000K/3000K, 230/250 volt, 50 HZ etc. complete in all aspects as per direction of Engineer in charge.
58SUPPLY OF LED Ceilling Light B22, 15 W, 600K / 4000K/3000K, 230/250 volt, 50 HZ etc. complete in all aspects as per direction of Engineer in charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57613344
AUTHORITY Government Departments
TENDER VALUE 29.51 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Irrigation Department
Work Description Tender for Construction Of One Classroom, One Library Room, And A Boundary Wall At Government Primary School Ratanfarm No. 1 (Sitarganj), An Utkrisht Vidyalaya (Model School).
Basic Detail
Tender No 02/2026-27 date 19 september 2026
Bidding Type Tender
Location
City Udam Singh Nagar
State Uttarakhand
Key Dates
Publish Date 21 Sep 2026
Submission Date 03 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 29.51 Lakhs
Tender Fee 2360
EMD 59100
Exemption Available
Document List
25e461ee-354d-4d45-b296-5e30399ba4bc.html
BOQ_118339.xls
Tendernotice_1 (33).pdf
Tendernotice_2 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

25e461ee-354d-4d45-b296-5e30399ba4bc.html

xls

BOQ_118339.xls

pdf

Tendernotice_1 (33).pdf

pdf

Tendernotice_2 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail