Rural Development Government Departments Closing in 5 days TDR #57612690

Tender For Construction Of Office Building Of Assistant Labour Officer At Kishorenagar Block

Issued by Government Departments · Dhenkanal, Odisha
Tender Value
1.91 Crore
Estimated cost
Bid Submission
28 Sep 2026
5 days left
EMD
1.91 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhenkanal → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Office Building Of Assistant Labour Officer At Kishorenagar Block

BOQ

Name of Work:- Construction of Office building of Assistant Labour Officer at Kishorenagar Block
Sl. No. Item Description
1CIVIL WORKSDiluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment) including cost of all materials, labour, T&P etc complete in all respect and as per direction of the Engineer-in-charge.Ground Floor
2Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge.Ground Floor
3Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. Ground floor
4Cement Concrete (1:3:6) using 40mm size hard granite C.B. metal approved quality from approved quarry including cost, carriage, royalty, cost of all labour. etc complete and as directed by E.I.C. Ground Floor
5Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge.Ground Floor
6Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Ground Floor
7Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Ground Floor
8First Floor
9Head Room(S+1)
10Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Ground Floor
11First Floor
12R.C.C. M-25 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete but excluding cost of reinforcement. Ground Floor, Footing
13Column
14Plinth Beam
15Lintel
16Roof Beam
17Roof Slab
18Chajja
19StairCase
20Shelves
21Fist Floor Column
22Lintel
23Roof Beam
24Roof Slab
25Chajja
26StairCase
27Head RoomColumn
28Chajja
29Roof Slab
30Providing 25 mm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips using 2% water proofing cement compound (Make -sika/fosroc/Equivalent) on new work. Ground Floor
31First Floor
32Head Room
33Straightening, cutting, bending bent up or coiled rods, including cranking, hooking, welding or jointing the M.S. rods or tor confirming to I.S. 432 (Plain) and 1785 (Tor) steel and binding, tying the grills, hoisting, lowering and placing in proper position required for R.C.C. works including cost, conveyance and taxes of M.S. rods or tor steel and binding wires of 18 to 20 gauge and cost of all labour etc.complete in all respect. Building Proper Ground Floor
34First Floor
35Head Room
3612mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C.Ground Floor
37First Floor
38Head Room
3916mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. Ground Floor
40First Floor
41Head Room
426 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment including watering, curing cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. Ground Floor
43First Floor
44Head Room
45Supplying, fitting and fixing Vitrified tile in floors of approved make confirmating to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C. Ground Floor
46First Floor
47Fixing Vitrified tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete. Ground Floor
48First Floor
49Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-charge.Ground Floor
50First Floor
51Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge . Ground Floor
52Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. Ground Floor
53First Floor
54Priming 1 coat with wall primer water bond cement primer including all labour, materials etc. complete. Ground Floor
55External Wall
56Internal Wall
57Head RoomExternal Wall
58Internal Wall
59Wall Painting two coats with approved Plastic Emulsion Paint including all labour, materials etc. complete. Ground Floor
60First Floor
61Head Room
62Wall painting two coat with any approved weather coat paint including cost of all materials, labour and T&P require for the work etc. complete as directed by the E.I.C. Ground Floor
63First Floor
64Head Room
65Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, taxes, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge
66Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge.
67Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primer & labour to give an even shade etc. complete. Ground Floor
68First Floor
69Head Room
70Painting two coats with approved enamel paints of approved colour, shade including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C. Gropund Floor
71First Floor
72Head Room
73Supplying, fiting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitting and fixture etc. complete
74Dressed seasoned sal wood work framed and fixed (wrought and put up) in frames of doors, windows & ventilabours
75Supplying and fitting-fixing of Un plasticised Poly Vinyl Chloride UPVC FENESTA or NCL VEKA LTD. Ventilator or Top Hung 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing or deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638 14,EN 477 95 and other applicable codes and standards. Ground Floor
76Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
77Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures.
78Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 5000 m as per Technical Specification Clause 301.5 and as per the direction of EIC.Ground Floor
79Construction of Granular Sub-base by providing coarsed graded materials,spreading in uniform layer by mortar grader on prepared surface mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the density, complete as per Clause - 401.
80Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.
81Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018.
82P.H. WorksSupplying all materials,labour,T&P and fitting&fixing of 4.0kgf/cm2 U-PVC soil waste ventilating pipes and fitting of the following O.D conforming to ISI No. 13592/1992 to walls with nails bobbins and wooden plugs or earth work in excavation in all kinds of soil for laying in trenche including jointing with supply of approved rubber lubricant by non-heat application method as per manufactures specification including tasting and refilling and trenches as per direction of E.I.C.(a)110mm dia PVC pipe
83(b)110mm dia PVC P trap
84(c)110mm dia PVC S/J/D
85(d)110mm dia PVC Door Tee
86(e)110mm dia PVC D/J/D
87(f)110mm dia PVC Door Bend
88(g110mm dia PVC Plain bend
89(h)110mm dia PVC offset
90(i)110mm dia PVC cowl
91(j)125mm dia CP Grating
92Supplying all materials,labour,T&P and cutting holes through brick/stone masonry walls for taking PVC pipes and fittings including making good the damages etc all complete as per the PH specification and direction of E.I.C. (a)375mm thick wall
93(b)250mm thick wall
94(c)Roof cutting
95Supplying all materials labour T&P and fixing wash down water closet(Anglo Indian water closet)with integral S or P trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cm(1:1) etc. all complete as per specification and direction of E.I.C.(a)EWC with S Trap with sheet cover(make-Parryware,Hindware)
96EWC(Matrix set)No.70002(P-18)
97Supplying all materials,labour,T&P and fixing wash basin with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc.all complete as per PH specification and direction of E.I.C.(a)550mmx400mm WHB with 32mm dia cp west,west pipe,brackets and connection pipe(make- parryware)
98(a)Pedestrial for basin(make- parryware)
99Supplying all materials, labour, T&P and fixing C.P./Brass Trap of the following nominal diameter for wash hand basin and Sink complete etc all complete as per specification and direction of the E.I.C. (a)32mm dia C.P.Bottle Trap
100Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with C.I/M.S brackets paintedwhite including holes in walls and making good the damages etc all complete as per specification and direction of the E.I.C.(a)550x450x200 mm stainless steel kitchen sink (Mousumi make)
101Supplying all materials,labour T&P and fixing mirror of superior glass mounted on 6mm thick AC sheet or plywood sheet and fixing to wooden plugs with CP screws and washers complete as per PH specification and direction of E.I.C.(a)600mmx450mm BE Mirror
102Supplying all materials,labour T&P and fixing standard size glass shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C.(a)(125x600)mm size glass-shelf with CP Guard rail(make -Parryware)
103Supplying all materials,labour T&P and fixing standard size CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C.(a)CP towel ring(make -Parryware)
104Supplying all materials,labour T&P and fixing standard size CP soap holder complete with CP Brass brackets fixed to wooden plug with CP screws as per P.H. specification and direction of E.I.C.(a)CP Soap holder
105Supplying all materials labour T&P and fixing Ceramic tiles/marble tiles/kota tiles/ kodapa tiles/chequered tiles in floors,threads,landing on 25mm thick bed of cm(1:1)jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete including cost of precast tiles etc. all complete as per specification and directiof E.I.C. (a)In GF
106(b)In FF
107Supplying all materials labour T&P and fixing porcelain glazed tiles/marble tiles/ Kota tiles/Kodapa tiles in dados skirting and risers of steps on 12mm thick CP(1:3)jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles etc. all complete as per spcificaiton and direction of E.I.C.(a)In GF
108(a)In FF
109Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member,9201 as top,9200 as bottom and middle member with frame section as 9221with tapered clip no 4660 & frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board.and as per direction of the E.I.C.
110SEPTIC TANKEarth work in all kinds of soil in excavation of foundation trenches within 50m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of E.I.C.Initial lift upto 1.50m
111From 1.50m to 3.00m depth
112Supplying all materials labour T&P and filling foundation & plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royality,taxes etc. all complete as per the direction of E.I.C.
113Supplying all materials labour T&P and providing cc(1:3:6)using 40cm HG metal including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc.all complete as per specification and direction of E.I.C.
114Supplying all materials labour T&P and providing cc(1:1.5:3)using 12mm HG chips including watering,curing,conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
115Supplying all materials labour T&P and providing Flyash brickwork in cm(1:4) F&P having crushing strength not less than 75kg/cm2 with dimensional tolerance +/-8%including watering,curing conveyance all material to worksite payment of royality taxes etc.all complete as per specification direction of E.I.C.
116Supplying all materials labour T&P and providing rigid and smooth centering & shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite,payment of royality, taxes etc. all complete as per specification and direction of E.I.C.
117Supplying all materials labour T&P and providing MS reinforcement for RCC works including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
118Supplying all materials labour T&P and providing RCC(1:1.5:3)using 12mm HG chips for RCC works including hoisting,laying,watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C.
119Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
120Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
121Supplying all materials labour T&P and fixing MS step iron in 12mm dia MS steel bar and fixing into walls of septic tank duly embedded in cc(1:3:6)all complete as per PH specification and direction E.I.C.
122Supplying all materials labour T&P and fixing of RCC baffle wall precast with cc(1:1.5:3)using 12mm bhg chips and fitted to septic tank as per P.H. specification and direction E.I.C.
123Supplying all materials,labour,T&P and providing fitting&fixing PVC Tee in wall including fitting the necessary with cc(1:1.5:3)with 12mm size hg chips all complete including watering,curing,conveyance of all materials to worksite, payment of royality,taxes etc. all complete as per specification and direction of E.I.C.(a)110mmx110mmx110mm PVC Tee
124Supplying all materials labour T&P and Providing cement flush pointing(1:3)to brick masonary including watering,curing,conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C.
125Supplying all materials labour T&P and providing 500x500x100mm thick RCC precast MH cover in cc(1:1.5:3)using 12mm hg chips placing the cover on the MH/S tank & finishing smooth all complete as per specification and direction of E.I.C.
126Filling in F&P with excavated materials including watering and ramming as per direction of E.I.C.
127Supplying all materials labour T&P and constructing inspection chamber of the following sizes with cc(1:3:6)using 40mm size hg metal on bed,1st class KB brickwork in cm(1:6)moulding&shaping the channel inside&benching with cc(1: 1.5:3)using 12mm size hg chips,12mm thick CP(1:3)with punning to inside, cement flush pointing(1:3)to outside,RCC cover slab in cc(1:1.5:3)using 12mm size hg chips with RCC manhole cover,e.w in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C.(a)Inside size 760mmx760mmx460mm
128Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:2:4) mix using 12 mm size H.G chips, foundation concrete (1:4:8) using 40 mm size HG metal on bed and aound trap , !st class KB Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C.(a)Construction of Gully Trap Chamber (0.25 x 0.25 inside Size)
129Supplying all materials labour T&P and laying PVC pipe sewer line Grade-A of the following internal dia in trenches(to level or slope)and jointing with gasket & stiff mixture or cm(1:1),cc(1:3:6)with 40mm size hg metal on bed of the trench and hunching or allround concrete encasing with cc(1:4:8)using 40mm size hg metal including curing,conveyance to worksite,payment of royality,taxes etc and testing all complete as per approved drawing,specification and direction of E.I.C.(a)110mm dia PVC pipe with allround Hunch top
130Supplying all labour T&P and constructing soakwaypit of the following sizes with dry brick walling from bottom upto invert of inlet pipe & 1st class KB brick work in cm(1:6)for the remaining height at top,12mm thick CP(1:4)inside & outside over masonary brickwork,gravel packing in the rear of well steining RCC coverslab in cc(1:1.5:3)using 12mm size hg chips fitted handles including ew in open well excavation in all kinds of soil and refilling the cavity around the pit & painting the iron work,watering,curing,conveyance of all meterails to worksite,payment of royality,taxes etc. all complete as per approved drawing specification and direction of E.I.C.(a)1.20m dia x 2.00m deep
131W/S SUPPLY PORTION:-Supplying all materials,labour,T&P and construction of masonry staging with providing 1st class KB brickwork in cm(1:6)of 0.46mtr height in staging,12mm CP in cm(1:6),RCC beam of 0.25mx0.30mx2.60m in cc(1:1.5:3)using 12mm size HG chips including centering,shuttering,bending and binding of rod etc watering,curring,conveyance of all materials to work site,payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.(a)Stagging for 2000ltr. Storage Tank (1st Floor)
132Supplying all materials,labour,T&P and Fitting&Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5mtr above GL and placing the tank in required position including conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.(a)2000ltr water storage tank(1st Floor)
133Supplying all materials,labour,T&P and fitting&fixing 10ltr capacity low level flushing cystern with a pair of cast iron or ms brackets complete with fittings such as syphonic arrangements 15mm nominal size brass/PVC ball valve with polythene float,CP brass handle,union and couplings for connection with inlet, outlet and overflow pipes,32mm dia c.p. flush bend,15mm dia. PVC inlet connection pipe including cutting holes and making good the same and connecting the flushbend with cystern and closet and connecting inlet pipe with supply main etc. all connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C. (a)10Ltr.Capacity low level cistern
134Supplying all materials,labour,T&P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89(sch-80) and pipe fitting of the following nominal bore with clamps including making good the wall,ceiling and floor testing all complete as per specification and direction of E.I.C.(a)32mm dia C-PVC pipe
135(b)25mm dia C-PVC pipe
136(c)20mm dia C-PVC pipe
137Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4)for taking GI/PVC pipe & fitting etc. all complete as per PH specification and direction of E.I.C.(a)In GF
138(b)In FF
139Supplying all materials,labour,T&P cutting holes in RCC floors,roofs etc.up to 19cm thick for passing GI/PVC pipes fittings and reparing the holes after insertion of pipe etc. with cc(1:1.5:3)including finishing so as to make it leak proof as per direction of E.I.C.
140Supplying all materials,labour,T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per direction of E.I.C.(a)In GF
141(b)In FF
142Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C.(make-Jaguar)a)15mm dia CP(LB)Bib cock
143(b)15mm dia CP(SB)Bib cock
144(c)15mm dia CP Two way Bib cock
145(d)15mm dia CP Pillar cock swan neck
146(e)15mm dia CP Angle Stop cock
147(f)15mm dia Health Faucet & 1.0m long Flexible pipe
148(g)25mm dia PVC FWV
149(h)15mm dia CP Flange
150(i)15mm dia CP Extension piece
1511.00HP Single Phase Submersible Pump SetSupplying of ISI mark 1.00HP single phase vertical submersible pump set with discharge of 900-1000ltr/hour and a head of 55-70m of reputed make like KSB/ Texmo & equivalent including all cost,conveyance and taxes etc all complete as per direction of E.I.C.
152Supplying all labour,T&P and fitting and fixing of 1.00HP single phase vetrical submersible pump set with commissioning and testing etc.all complete as per direction of E.I.C.
153Supplying fitting & fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1.00HP single phase submersible pump including all cost, conveyance of all taxes etc all complete as per direction of the E.I.C.
154Supplying all materials labour T&Pand fitting & fixing of 2.5mm2 3core copper flat suitable cable having ISI mark of reputed company like BCH/Finolex or equivalent & connecting the pump starter including cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C.
155Supplying fitting and fixing of plastic rope MS Well cover,MS Clamp,Stainless steel short piece,bend & socket including all cost,taxes etc all complete as per direction of the E.I.C.
156Supplying fitting and fixing of HDPE Pipes & pipe fittings with making connection to pump set including all cost conveyance and taxes etc all complete as per direction of the E.I.C.
157200mmx150mm Size Bore WellL Through DTH Method:-Labour for drilling of perfactly vertical bore holes as specified dia.For a specified depth below GL through consolidated & uncosolidated rock with down the hole hammer drilling rigs or combination drilling rigs(600cfm/200psi) as required to suit the site conditions as per the direction of E.I.C.including use of own rigs with its accessories,tools & plants and consumable etc. for lowering 200mm dia PVC/GI pipes for house fitted with socket and with or without well screen as per the necessity for the soft,medium,hard & boulder formation(PCV/GI)casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and with drawing after complete of tube well.(Tube well-1No)(a)Drilling of 200mm. dia. Bore-0.00mtr to 44.40mtr
158(b)Drilling 150mm dia. Bore-44.40mtr to 200.00mtr
159Lowering the following GI/PVC pipe with or without soltted pipes as per necessity from GL upto 30.00mtr depth and fitted and fixed in perfecty vertical position including cutting and threading pipes and soltted pipes and supplying and fixing of all jointing materials,T&P etc the top of the casing pipe threaded including piping tubewell to prevent entry of foreign materials from above(PVC/ GI)supplied by the contractor(including cost of pipe)(a)Lowring of 200mm dia pipes-0.00mtr to 44.40mtr
160(b)Cost of 200mm dia PVC casing pipes-0.00m to 45.00m
161Cleaning & developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of E.I.C.
162Electrical WorksMAIN DB Supply & fixing of 63A TPN Panel board 1. 63A 4P 30KA MCCB with Spreader(Make- Legrand/Seimens/L&T/C&S)-1 No 2.63A Change over(Manual) (make-ABB/Siemens/SCHNEIDER/L&T/Legrand-1 No 3. 63A COPPER bus bar- 2set 4.40A 4P MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand-5Nos. 5.SPD(Type1+2,50kA,3P+N) (make-ABB/Siemens/SCHNEIDER/L&T/Legrand-1No 6.40A DP MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand- 4 nos 7.6-32 C Series SP MCB-4 Nos 8. Digital Volt meter & Ameter three phase-2Nos 9. All accesories & Connection (Rating & Danger borad)
163Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire = Finollex / L & T/ Anchor/ Havels/ V-Guard/ Greatwhite / Polycab) Group A (1.1.1)
164-do- .... Group B (1.1.2)
165-do- .... Group C (1.1.3)
166S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required.2 Modular box with base & cover (1.24.2)
1674 Modular box with base & cover (1.24.3)
1686 Modular box with base & cover (1.24.4)
1698 Modular box with base & cover (1.24.5)
17012 Modular box with base & cover (1.24.6)
171S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4)
172S/F of 6 Modular GI box in recess with suitable size of Modular base cover in front including providing and fixing 2 nos 3 pin 5/6 amp. Modular Socket out let & 5/6amp. Modular type switch,connection,painting etc. as required.(2X1.25.1+2X1.25.4)+6 MODULE
173S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required (1.25.3+1.25.5)+4 MODULE BOX
174S/F of computer board (Modular Type) consisting of 3 nos. of 5 amp plug and switch and 6 amp MCB, Indicator complete with wiring on 12 module M.S.box with B.k.cover(1.24.6 + 3 x (1.25.1+ 1.25.4) + 2.6.1)+Indicator
175Wiring for circuit I sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS- 694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required ( Make of wire- Finolex/ / Anchor/ Havels/ V-guard / HPL / L&T / Gratewhite / Polycab). -do- 2x1.5sqmm +1x1.5sqmm ( 1.8.1 )
176-do-2x2.5sqmm +1x1.5sqmm ( 1.8.2 )
177-do- 2x4sqmm +1x1.5sqmm ( 1.8.3 )
178-do- 4x4sqmm +2x2.5sqmm ( 1.8.9 )
179S/Fof 'c' series SP MCB of 5A to 32 Amp rating 240Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP)(2.6.1)
180S/F of 4 way (4+12) TPN MCB DB double door (2.5.5)
181S/F of 40A FOUR POLE MCB C Type( Make - HAVELLS /Anchor/Greatwhite/L&T)
182S/F of 63A FOUR POLE MCB C Type ( Make - HAVELLS /Anchor/Greatwhite/L&T)
183S/F of Call bell/ Buzzer ISI marked sutiable for DC/AC single Phase 230 volts complete as required.(1.30)
184S/F of batten holder BK angle holder ISI marked including connection etc instead of ceiling rose (Make: Cona / Anchor / Havells / Greatwhite / Preeti / HPL) (1.29-1.28)
185Earthing with G.I. earth pipe 3 metre long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arragement and watering pipe etc. with charcoal and salt as required.(3.2)
186Supply and laying 6 SWG G.I wire in recess for loop earthing as required ( 3.17)
187S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS)
188S/F of electric step ceiling fan regulater in existing switch box including connection with 1.5sqmm FR PVC insulated single core multistrand copper conductor earthing the regulator as required.(1.38)
189S/F of Fan hok S'type made of 16mm MS rod as per specificationn
190S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells )
191S/F of 18-25 watt LED Tube light fitting compoete with all connection. including fixing and all accessories as per direction of Engineer-In-charge (Make: Havels / Phillps / Crompton / Polycab / HPL)
192Supply & fixing of 12W LED Ceiling Light (S)(Make- Havells/panasonic Bajaj/philips/Wipro) all accessories.
193Supply & fixing of 15W LED Ceiling Light (S)(Make- Havells/panasonic Bajaj/philips/Wipro) all accessories.
194Supply of instalation, Testing commissioning of 12 Watt. LED bulb
195S/F of 15A modular socket on 2 Modular Metal box for A.C
196S/F of 32A C series D.P. MCB for A.C (make: Legrand/Anchor/Havels/HPL)
197S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand)
198S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB)
199SITC of 1.5 Ton 5 star BEE Rating Inverter type split A.C. M/C with all accessories and connections and installation (Make - LG/ O General/Daikin)
200S/F of 4KVA Voltage stabilizer(130-300) upto 1.5 Ton AC(Make-Microtech/V-Guard)
201S/F of 400mm Wall fan with all accessories and connections (Make-Usha-Maxx Air Ultra/Polycab-Arey HS/Cropmton-WM Hiflowave/ Havells-Accelero HS/ Anchor-Altrix HS- OWH/ Orient-Wall43/ Great White-WYNO WF )
202S/F of 2000 VA Inverter with 2 nos. 180 Ah Tubular battery including trally arrangement (Make: Microtake/ Luminous/Exide)
203wiring to sub main with 1*1.5 mm2 single core multi strand copper wire for inverter wiring (1x1.5mm)
204Supply of 3.5core 35sqmm PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Armoured cable ( MAKE-HAVELLS/polycab/RR Kable/Rhino cable)
205Laying of 35sq mm. 3½ Core cable on surface(5.5.2)
206Laying of 35sq mm. 3½ Core cable in ground(5.1.2)
207Supplying and making end termination with brass compression gland and aluminum lugs for 35sq mm. 3½ Core cable(5.8.21)
208Signage:SITC of Flexyle Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 5 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with S.S stud for fire order, fire action and fire evacuation signages.(GROUND FLOOR,FIRST FLOOR,STAIRCASE,LIFT,FIRE EXIT,FIRE EXTINGUISHER,MCP,FIRE PANEL)
209SITC of conventional type Single ZONE IP55 Fire Alarm Control Panel made out of 18 Gauge (1.22mm) CRCA sheet with powder-coated finish. Compatible to all type of Conventional Detectors. with 12V & 7A two nos of Battery backup shall be sufficient for 24 hours for normal condition and 15 mins of Full Load Alarmed operation.Panel should be EN listed.Make-GST/Bosch/Cooper/AGNI.
210Supply, installation, connecting, testing and commissioning of conventional type heat cum Photoelectric Smoke Detector With Remote Indicator Output and Magnetic Test Function, With Base (Certified by LPCB).Make-GST/Bosch/Cooper/AGNI
211Supply, installation, connecting, testing and commissioning of conventional Hooters min. 95 db output Make-GST/Bosch/Cooper
212Supply, installation, connecting, testing and commissioningof Conventional Manual Call Point in ABS plastic as required complete.Make-GST/Bosch/Cooper/AGNI
213Looping Cable Supplying, installing, testing and commissioning of Fire Survival armoured cable,Fibre glass tape wrapped, ZH inner, outer sheath 2C X 1.5 sq. mm, PVC insulated copper wires with aluminium armour confirming to IS standards and specificationsMake-GST/Bosch/Cooper/AGNI.
214FIRE EXTINGUISHERS :Providing & fixing ABC type (Dry powder type ) extinguishers. Including all accessories as per IS specification (IS :15683) Consisting of welded MS cylindrical body with discharge hose ,discharge valve ,suspension brackets,initial filling etc. complete as required., initial filling etc complete as required. Capacity - 6 kg . Make : Fireshiled/ Kanex/ Safex/AGNI
215Providing & fixing Water based Carbon-di-oxide 4.5 ltrs. fire extinguishers as per IS specification consisting of welded MS cylindrical body ,squeeze lever discharge valve fitted with internal discharge tube ,30 cm long high pressure discharge hose ,discharge nozzle,suspension brackets,finished exteranally with red enemel paint and fixed to wall with brackets with rawl plug/dash fastners complete with initial charging. Make : Fireshield/Kanex/ Safex/ AGNI
216Supply installation testing & commissioning of 10 passenger liftAutomatic lift with ARD system (With machine room type)Capacity 10 persons, 680 kg , Speed 0.63 m/sStops & Openings 2 Stops, 2 OpeningsFloor designations G,1Machine type & Location - Gearless machine located in the shaft on top of the guiderails/ Gearless machine in machine room as per site condition. Control- Simplex Collective Selective Control,Drive ACVVVF,Power supply 415 volts (+10 / -15%), 3 phase, 50 Hz (+/- 5%), AC.,Car door 2 panel automatic center opening door with ACVF drive in Stainless steel Silver Sky finish,Landing door (Group1) 2 panel automatic center opening door in Stainless Steel Silver Sky finish on 2 floors,Car design Silver Grace,Car flooring 20mm recess provided for granite/marble flooring (by customer) ,Landing operating panel Individual landing operating panel for each elevator,Lift to be inspected by Electrical Inspector before handing over, Make: Thyssenkrupp/Johnson/OTIS/KONE/MITSUBHISHI/SCHINDLER
217Recessed wiring to Light point/ Fan point/Callbell point/Exhaust Fan Point with 1.5 sqmm, FR PVC Insulated single core multistrand copper conductor of ISI marked with 20 mm dia non- metallic PVC flexible conduct with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor and earth wire incouding all accessories and connection as per direction of engineer in charge (Make of wire = Finolex/L&T/ Anchor/ V-Guard) deducting the cost of S/F 100 mm x 100 mm x 60 mm M.S. Box with backlite cover-1 No.)Group A 1.1.1-1.24.2
218S/F to 16/18 SWG metal box of following sizes (normal sixe) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.100 mm x 100 mm x 60mm deep (1.24.2)
219S/F of 5 amp switch and 5A. Socket outlet of ISI marked on existing board (1.25.1 + 1.25.4)
220Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Finolex/L&T/Anchor/Havels/V-Guard). 2 x 2.5 sqmm + 1 x 1.5 sqmm (1.8.2)
221S/L of 25 mmx5 mm Copper strip on surface for earth looping
222Provision of 4C 16 sqmm aluminium armoured cable with all connections(25)
223Laying of above cable on wall surface
224S/M of End termination of above cable
225S/F of mcb 12 way single door (2.3.3)
226SITC of 63A 4 P MCCB panel with cu busbar and 1 no. of MFM with all acceries as per direction of Enginee-in-cjarge .
227S/F of 2 pole MCB of 16 Amp rating 10 KA MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection , testing and commission etc.
228S/F of 63A 4P 415V AC 10KA C Curve MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand)
229S/F of 4 pole ELCB/RCCB of 63 Amp rating ( 16 KA ) for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection , testing and commission etc.
230Earthing with cupper earth plate 600 mm x 600 mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.(3.5)
231Supply and laying 8 SWG cupper wire in recess for loop earthing as required (3.7)
232Supply, Installation, Testing and commissioning of bulkhead fittings including fixing of 9 watt LED Lamp
233Supply, Installation, Testing and commissionioning of 225mm sweep exhaust fan in the existing opening, including making the hole to suit the size of the above fan making good the damaged comlete, connection,etc. as required.(1.43)(Make: Bajaj/Almonard)
234S/F of MS angle , channel with fabrication & primer coluor. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57612690
AUTHORITY Government Departments
TENDER VALUE 1.91 Crore
LAST DATE 28-09-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Construction Of Office Building Of Assistant Labour Officer At Kishorenagar Block
Basic Detail
Tender No Building Online-AGL-20/2026-27
Bidding Type Tender
Location
City Dhenkanal
State Odisha
Key Dates
Publish Date 21 Sep 2026
Submission Date 28 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 1.91 Crore
Tender Fee 10000
EMD 1.91 Lakhs
Exemption Available
Document List
1c13aa82-2bbe-4d5c-86b8-4a8867ef2ff6.html
BOQ_610262.xls
Tendernotice_1 (20).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

1c13aa82-2bbe-4d5c-86b8-4a8867ef2ff6.html

xls

BOQ_610262.xls

pdf

Tendernotice_1 (20).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders