Housing Urban and Rular Development Government Departments Closing in 2 days TDR #57612495

Tender For maintenance of electrical installation & Fans, repair maintenance Pump Sets I/C Compound Lights At D-Ii Flats, Vasant Kunj, New Delhi During The Year 2026-27. (Sh:- Improvement Of electrical installation Work In C8 & Other Vacant Flats As

Issued by Government Departments · Delhi, Delhi
Tender Value
26.95 Lakhs
Estimated cost
Bid Submission
25 Sep 2026
2 days left
EMD
53919
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for maintenance of electrical installation & Fans, repair maintenance Pump Sets I/C Compound Lights At D-Ii Flats, Vasant Kunj, New Delhi During The Year 2026-27. (Sh:- Improvement Of electrical installation Work In C8 & Other Vacant Flats As & When Required)

BOQ

Name of Work:- MOEI & Fans, RMO Pump Sets i/c Compound Lights at D-II Flats, Vasant Kunj, New Delhi during the year 2026-27. (SH:- Improvement of EI Work in C8 & Other vacant flats as & when required)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group B
3Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
4Group B
5Supplying and fixing following size/ modules, GI box as reuired on the site alongwith modular base & cover plate for modular switches in recess/surface etc. as required.
612 Module
78 Module
86 Module
93 Module
101 or 2 Module
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
125/6 A switch
133 pin 5/6 A socket outlet
1415/16 A switch
156 pin 15/16 A socket outlet
16Bell Push
17Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
183 x 1.5 sq. mm
193 x 4 sq. mm
206 x 1.5 sq. mm
216 x 4 sq. mm
223 x 6 sq. mm
236 x 6 sq. mm
24Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
2520 mm
2625 mm
27Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
284 X 10 sq. mm + 2 X 6 sq. mm earth wire
29SITC of Video call bell with display with necessary specification Video Door Bell Pro 2K Resolution with 3MP Lens,.140° Field of Vision, Night Vision, 2W Speaker Person Detection, Visitor Log, Intruder Alarm, Works with Alexa, Wireless Chime with 36 tunes with all accessories etc. complete as required.
30Pdg. and fixing of ding dong bell for quarters i/c connection, testing etc. complete as reqd.
31Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
328 way (4 + 24), Double door
33Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
3412 way (4 + 36), Double door
35Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
36Single pole
37Double pole
38Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
39100 A
40Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
411200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
42Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
43Supplying, installation, testing and commissioning of 600 mm sweep ceiling fans without regulator i/c wiring the down rod of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.complete as reqd.
44SITC of Single Wall Light suitable for retrofit 7.5 Watt Led Lamp. Base of the Wall Light is made of Spun CRCA Sheet and is Circular/oval shape or any other shape as approved . Arm of the wall light is made of mild steel tube. Holder Cap and design is made of CRCA sheet duly approved colour Plated. Base and Arm are duly Powder coated in approved Colour Shade , all colour , shape and model to be approved by the client or Engineer in charge . Mounting Plate is made of CRCA Sheet . Hardware parts are made of mildsteel duly plated. E-27 Lamp holder is fitted in the fixture . Frosted Glass diffuser is provided with the fixture and E-27 LED bulb 7 W in warm/cool light to be provided with the fixture etc as required.
45SITC of Double Wall Light suitable for retrofit 7.5 Watt Led Lamp. Base of the Wall Light is made of Spun CRCA Sheet and is Circular/oval shape or any other shape as approved . Arm of the wall light is made of mild steel tube. Holder Cap and design is made of CRCA sheet duly approved colour Plated. Base and Arm are duly Powder coated in approved Colour Shade , all colour , shape and model to be approved by the client or Engineer in charge . Mounting Plate is made of CRCA Sheet . Hardware parts are made of mildsteel duly plated. E-27 Lamp holder is fitted in the fixture . Frosted Glass diffuser is provided with the fixture and E-27 LED bulb 7 W in warm/cool light to be provided with the fixture etc as required
46Supplying, installation, testing & commissioning of 200 mm sizes white body Sweep PVC body Fresh Air Ventilator Exhaust fan with louver shutter in the existing opening of toilet room/kitchen etc i/c connection with 1.5 sqmm FRLS PVC insulated wires and fibre sheets etc as reqd.
47Supplying, installation, testing & commissioning of 250 mm sizes white body Sweep PVC body Fresh Air Ventilator Exhaust fan with louver shutter in the existing opening of toilet room/kitchen etc i/c connection with 1.5 sqmm FRLS PVC insulated wires and fibre sheets etc as reqd.
48Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .
4912 -15 watt
5018 watt
51Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
5218- 22 watt
53Supplying and replacement, installation, testing & commissioning of 2 feet, 10-12 watt capacity wall mounted LED batten fitting with extruded aluminum housing having lumen output > 100 lumens/watt in cool daylight (5700 k to 6500k) power factor> 0.90 CRI> 70 surge protection >, 2.5 kv with integrated electronic driver suitable for mirror light i/c connection of wires with 1.5 sqmm FRLS PVC insulated wires etc complete as reqd.
54S/I/T/C of 25 Lts. Capacity storage Geysers with following specification :- Mount type – Vertical Type – Storage Water Heater Capacity – 25 Lt. Energy rating – 5 Star Technology – Sale care Technology Temperature Controller – Adjustable Controller Bar Pressure – 8 Wattage – 2000 W Voltage – 230 V Frequency – 50 Hz Rate Max. Temp -75 Degree Outer Body – MS Insulation – PUF Heating Element Incoloy - 800
55S/I/T/C of 5 Lts. Capacity storage Geysers with following specification :- Mount type – Vertical Type – Storage Water Heater Capacity – 5 Lt. Energy rating – 5 Star Technology – Sale care Technology Temperature Controller – Adjustable Controller Bar Pressure – 8 Wattage – 2000 W Voltage – 230 V Frequency – 50 Hz Rate Max. Temp -75 Degree Outer Body – MS Insulation – PUF Heating Element Incoloy - 800
56SITC of wall/celling mounted type kitchen chimney of 600mm, nominal width, air flow not less than 1400 m3/hr. at rated speed having curve glass, three speed control, thermal auto clean & filter less technology, touch control with motion sensors and metal oil collector cup features etc. aluminium flexible pipe of 150 mm dia upto 4 mtr. alongwith all accessories etc. complete as reqd. i/c OEM shall give minimum warrantee of 2 years for product and 10 years for motor
57Supplying, Installation, Testing and Commissioning of up and down 10 Watt LED light Warm White (Yellowish Tone), Wattage:10 Watts; Voltage: 200V AC; Size Name: 12CM, Finish Type: Powder Coated; Mounting Type: Wall Mount; Wattage: 6.0; i/c connection, testing etc. complete as required.
58Supplying Installation, Testing and Commissioning of Mirror light with functionality, delivering a sleek and moisture-resistant design ideal for bathrooms, powder rooms, and more. With 100 lumens per watt and a refined profile, it offers energy-efficient brilliance while enhancing your decor. Let it be your daily reminder to express, reflect, and shine with warmth and soul etc. complete as required.
59S/I/T/C of Warm type LED Rope light of power 8watt/Mtr, luminaire output-600 lumens/mtr, IP-65 protected with electronic driver having PF >9 and THD <10% Surge protection-3.5kV on poles using necessary means i/c connection, testing, commissioning etc. as required.
60SITC of wall mounted cabin fan 450 mm sweep suitable for operating on 230 volt single phase AC supply i/c connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable earth etc as reqd.
61Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
62125 A, 16 KA,TPMCCB
63Sub Head -II (Credit of Dismantle material)Less for credit buy back of old irrepairable defective items
64Assorted size wire in pieces
65Assorted size switch/socket
66Assorted size conduit/ MS Box/junction box/angle iron frame etc.
67Unserviceable Ventilation Fan
68Unserviceable Batten Fitting
69Unserviceable Downlighter
70Unserviceable Ceiling fan
71Unserviceable Wall fan
72Unserviceable Single/Double Wall Light Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57612495
AUTHORITY Government Departments
TENDER VALUE 26.95 Lakhs
LAST DATE 25-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for maintenance of electrical installation & Fans, repair maintenance Pump Sets I/C Compound Lights At D-Ii Flats, Vasant Kunj, New Delhi During The Year 2026-27. (Sh:- Improvement Of electrical installation Work In C8 & Other Vacant Flats As & When Required)
Basic Detail
Tender No 68/EE(E)/EMD South Elect. Divn./PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 19 Sep 2026
Submission Date 25 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value 26.95 Lakhs
Tender Fee Ref. Documents
EMD 53919
Exemption Available
Document List
72e9b549-e666-4b9c-87d8-1a61a97317c8.html
BOQ_398408.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

72e9b549-e666-4b9c-87d8-1a61a97317c8.html

xls

BOQ_398408.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders