Tender For Repairs/Replacement Of Old Damaged Point Wiring And Accessories Of Ies Change Room Of Unit-I To Xii And Xiv Inside Factory At O. F. Chanda.
Tender Value
73.98 Lakhs
Estimated cost
Bid Submission
10 Oct 2026
17 days left
EMD
1.36 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandrapur → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs/Replacement Of Old Damaged Point Wiring And Accessories Of Ies Change Room Of Unit-I To Xii And Xiv Inside Factory At O. F. Chanda.
BOQ
| Sl. No. | Item Description |
| 1 | Cat (A) -Items to be supply and fixing |
| 2 | Taking down existing point wiring carefully and making good disturbed surface of wall & floors etc. all as per the direction of Engineer In-charge. |
| 3 | S&F, One light point or one fan point with- a) 2.5 sq. mm. stranded Cu. Conductor PVC sheathed cables as per IS-694-1990 (make :- Jonson/Supercab/Finolex/Polycab or equivalent to mention make). (b) Stove enameled steel conduit of size 20/25 mm. Dia. and 1.5 to 2.0 mm thick as per IS-9537 (P-2) 1981 and accessories, joint boxes, m.s. box type terminal boards with laminated top for fixing switches, sockets & fan regulators etc. (c) Continuous G.I. earth wire of 18 SWG. Complete, all as per the direction of Engineer In-charge. |
| 4 | S&F, One 3 pin 5 Amp. socket outlet independent point with-a) 2.5 sq. mm. Stranded Cu. Conductor PVC sheathed cables as per IS-694-1990. (make – Jonson/Supercab/Finolex/polycab or equivalent to mention make). b) Stove enameled steel conduit of size 20/25 mm . Dia. and 1.5 to 2.0 mm thick as per IS -9537 (P -2) 1981 and accessories, joint boxes, m.s. box type terminal boards with laminated top for fixing switches, sockets & fan regulators etc.(c) Continuous G.I. earth wire of 18 SWG. Complete, all as per the direction of Engineer In-charge. |
| 5 | S&F, One 3 pin 5 Amp. socket outlet point on same board with 2.5 sq. mm. Stranded Cu. Conductor PVC sheathed cables as per IS-694-1990 (make – Jonson/Supercab/Finolex/polycab or equivalent to mention make). all as per the direction of Engineer In-charge. |
| 6 | S&F, One 3 pin 15 Amp. Socket outlet point with- (a) 4 sq mm stranded, Copper Conductor PVC sheathed cables as per IS-694-1990 (make :- Jonson/Supercab/Finolex/Polycab). (b) Stove enameled steel conduit of size 20/25 mm. Dia. and 1.5 to 2.0 mm thick as per IS-9537 (P-2) 1981 and accessories, joint boxes, m.s. box type terminal boards with laminated top for fixing switches , sockets & fan regulators etc. (c) Continuous G.I. earth wire of 18 SWG. complete, all as per the direction of Engineer In-charge. |
| 7 | S&F, piyano Switch flush type 5 Amp. Single pole one way white colour as per IS- 3854/ 1997 (make:-Anchor/Cona or equivalent to mentioned make) all as per the direction of Engineer In-charge. |
| 8 | Supply & Fixing Socket outlet 2 in 1 3 pin, 5 Amp. Flush type as per IS- 1293/ 1988 (make:-Anchor/Cona or equivalent to mentioned make ), all as per the direction of Engineer In-charge. |
| 9 | Supply & Fixing Lamp holder , PVC/ polycarbonate type with back plate for batten / Angle fitting as per IS-1258/1987 (make:-Anchor or equivalent to mentioned make ), all as per the direction of Engineer In-charge. |
| 10 | S&F, Ceiling rose, surface bakelite 2/3 terminals as per IS- 371/1979 (make :- Anchor/Cona or equivalent to mentioned make) all as per the direction of Engineer In-charge. |
| 11 | S&F, Switch socket combination 2 in1, 3 pin, 5 & 15 Amp, flush type. As per IS- 4615/1968 (make:- Anchor/Cona or equivalent to mentioned make) all as per the direction of Engineer In-charge. |
| 12 | Supply & Fixing of stepped type, socket shape, Electronic five step fan speed regulator (make:-Anchor/Cona or equivalent to mentioned make ), all as per the direction of Engineer In-charge. |
| 13 | Supply and fixing LED light fitting 1X18 Watt, 220volt AC, decorative box type with driver, holder including LED tube light (T8) connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including base insulator/wooden round block. (make:-Bajaj/Phillips/Crompton or equivalent to mentioned make) all as per the direction of Engineer In-charge. |
| 14 | Supply & Fixing sheet metal enclosure for single pole & neutral, with socket, plug top 2 pin & earth, and MCB of 20amp capacity (make – MDS/Havelles or equivalent to mentioned make), all as per the direction of Engineer In-charge. |
| 15 | S&F, MCB isolator 3 pole , 100 Amp, AC-22 category confirming to IS- 13947-3 (make – MDS/HPL/Havells/Standard or equivalent to mentioned make) all as per the direction of Engineer In-charge. |
| 16 | S&F Exhaust fan steel body AC single phase 230 V of size 300 mm sweep, with blade, frame and louvers (make:-Bajaj/Phillips/ Crompton or equivalent to mentioned make ), all as per the direction of Engineer In-charge. |
| 17 | S&F, sheet metal enclosure for MCB. DB. Single pole & Neutral, 2 way without bus bar, 230 volt, Surface mounting type with including dummy packing. ( make – MDS/HPL/ Havells/Standard or equivalent to mentioned make) all as per the direction of Engineer In-charge. |
| 18 | S&F, sheet metal enclosure for MCB. DB. Tripple pole & Neutral, 4 way (for Each phase), 415 volt, double door Surface mounting type, comp. with copper bus bar and neutral link etc. (make – MDS/ HPL/ Havells/Standard or equivalent to mentioned make) all as per the direction of Engineer In-charge. |
| 19 | Supply & Fixing single, Sheet metal enclosure (MCB DB), Surface mounting type, single pole & neutral, 12 way, consisting of 40 Amp. DP isolator-01 no, single pole MCB 240 V, 10 KA, B curve 10 & 20 Amp. capacity - 10 no. (make – MDS/Havelles or equivalent to mentioned make) along with wooden fixing board, all as per the direction of Engineer In-charge |
| 20 | Excavation n.exc.1.5 meter wide and 2.4 meter depth in soft loose soil and getting out etc. for earth pit of power system complete as per the direction of Engineer In-charge. |
| 21 | Returning, filling in including spreading, leveling and well ramming in layers of excavated soft loose soil in earth pit & trenches and making good disturbed surface, complete as per the direction of Engineer In-charge |
| 22 | Supply and Fixing of Earthing complete with G.I. earth plate electrode 600 X 600 X 6 mm thick buried directly in the ground vertically to a depth not less than 2.25 meter below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below ground level, connected to galvanised earth strip 25X4 mm as earthing lead upto test point, all as specified and shown in electrical plate no. 3 of SSR part 1 and testing on completion, all as per the direction of Engineer In-charge. |
| 23 | Supply and fixing 6 mm diameter G I wire for earthing connection, all as per the direction of Engineer In-charge. |
| 24 | S&F, of GI steel tubes of medium grade of 40 mm bore for protection of G I strip complete as per the direction of Engineer In-charge |
| 25 | S&F, of GI steel tubes of medium grade of 20 mm bore, 1.8 meter long with funnels for provision of water pipe as per the direction of Engineer In-charge |
| 26 | M&L for provision of cement concrete of type- B2 1:2:4, 40 mm graded aggregate in foundation for earth pit, complete as per the direction of Engineer In-charge. |
| 27 | Material & Labour for providing and fixing of 33 nos. precast cement concrete earth pit chamber of size 0.5X0.5X0.5 meter having 10 cm wall thick made from cement concrete of type- B1, 1:2:4, 20 mm graded aggregate etc. all as per the direction of Engineer In-charge. |
| 28 | M&L for provision of mild steel TMT bars of 8 mm dia. Including m.s. binding wire for rainforcement in PCC covers etc, all as per the direction of Engineer In-charge. Each cover require 10 pc of 0.5 meter (8 for mesh & 2 for handle) |
| 29 | S &F submainwiring a) 2x6.0 sq. mm +1x4.0 sq. mm earth wire with stranded copper conductor PVC insulated, 1100 Volts grade cable (Red, Yellow, Blue and Black colour) confirming to IS-694-1990 (Make- Jonson/Supercab/Finolex/Polycab or equivalent to mention make) b) Stove enameled steel conduit of size 20/25 mm. Dia. and 1.5 to 2.0 mm thick as per IS-9537 (P-2) 1981 and accessories, joint boxes etc. (c) Continuous G.I. earth wire of 18 SWG. Complete, all as per the direction of Engineer In-charge. |
| 30 | Supply and fixing 240V, 10 KA 'B' curve miniaturecircuit breaker (MCB) of single poles and currentcarrying capacity 6-20 AMP, in the MCB DBComplete with connection testing andcommissioning. (make – MDS/Havelles or equivalent to mentioned make), all as per the direction of Engineer In-charge. For 6 amp-168 & 10 amp-612 . |
| 31 | Supply and fixing 240V, 10 KA 'C' curve miniaturecircuit breaker (MCB) of single poles with neutral (SPN and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning. (make – MDS/Havelles or equivalent to mentioned make), all as per the direction of Engineer In-charge. |
| 32 | S&F Main switch 100amp SDF (Switch Disconnector Fuse Unit) in CRCA Sheet Enclosure, 100 Amp, 3 Pole With Neutral 415 Volt With extention box for suitable termination of cable & also include the glands lugs and dismentling of Existing main switch Confirming To Is/IEC 60947-3, Make: SIEMEN, L&T, ABB Or Equivalent. all as per the direction of Engineer In -charge |
| 33 | Cat (B) - Buy Back Items |
| 34 | Credit to contractor for old removed point wiring material which consists of old ms conduit, main switch, Al. conductor single core wires, old switches, sockets etc, all as per the direction of Engineer In-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender