Educational and Research Institute Government Departments Closing in 7 days TDR #57612335

Tender For Electrical Maintenance Work Of Swimming Pool.

Issued by Government Departments · Kanpur Nagar, Uttar Pradesh
Tender Value
5.40 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
7 days left
EMD
10816
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Maintenance Work Of Swimming Pool.

BOQ

Name of Work:- Electrical maintenance work of Swimming pool.
Sl. No. Item Description
1Supplying & drawing following sizes of FRLS PVC insulated copper conductor single core cable in / on the existing surface / recessed, PVC / steel conduit as reqd.
23 x 1.5 Sq.mm..
33 x 4 Sq.mm..
4Supply and drawing steel armoured, XLPE insulated, PVC intersheathed copper conductor 3 core round cable 1100 volt grade as per IS 7098 (Part 1) 1988 Complete as required.
53 core armoured 1.5 sq.mm
6Supplying and fixing following way, Vertical type triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. ( But without MCB/RCCB/Isolator).
74 way (4 + 12), Double door
8S & F MCB of following pole and rating 240/415 volts, 10kA, 'C' series in the existing MCB DB complete with connection, testing & commissioning etc as reqd.
9Single Pole 6 amp to 32 amp
10Supply, fixing, testing & commissioning MCB of following pole and rating 240/415 volts 'C' curve 10kA in the existing MCB DB complete as reqd. Make_Legrand
11Triple Pole 40 amp to 63 amp
12Triple pole & Neutral 40 amp to 63 amp
13Earthing with G.I earth pipe 4.5 metre long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
14Providing and fixing 6 SWG dia. GI wire on surface or in recess for loop earthing as required.
15Supply, Installation, testing & commissioning of AC ceiling fan of following sweeps, aluminium die cast body , copper wound, double bearing, less 70 watts 220 volts 50 Hz without regulator I/c wiring the down rods of standard length up to 30 cm with 1.5 sq.mm. PVC insulated copper conductor single core cable etc as reqd. ( ISI marked.)
161400 mm Make_Havells; model: Samrat HS
17Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
181 Output per phase and suitable for single phase supply
19Supply,fixing, connecting and commissioning power contactor of following ratings and 3 pole (magnetic release) including providing connection etc. as req
20MNX-32, 230/415 V,50 Hz
21LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).: Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2225 watt
23LED Flood Light, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing suchthat LED junction temperature shall not rise above 90°C).
2450 watt
25Supply,Installation,Testing and commissioning LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old complete as requiired.
26LED Post Top Lantern 40 watt (Make_Crompton Cat.No.LPTO-40-CDL-M)
27Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required
2832 mm dia
29Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
30Supply & fixing of 65 mm dia.'B' class GI pole 4.5 mtr. Long i/c base plate 300 x 300 x 3mm GI reducer & nipple for mounting the fitting with painting etc. grounting in cement concrete 1: 3: 6 (1 cement : 3 coarse sand : 6 grade stone aggregate 40mm complete as reqd.
31S&F, connecting and commissioning MS pole box of 16 SWG MS sheet of size 300x300x150mm. Box shall accomadate 04 nos SPN MCB (MCB not included), should have neutral link and panel key type lock front door duly painted etc. complete as required.
32Dismantling and fixing/refixing of LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old and submitting dismantle in store complete as requiired.
33Above 3 meter and upto 6 Meter
34Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size upto 35 sq.mm.
35In pipe
36In open duct
37On surface with MS clamp (clamped with 1mm thick saddle)
38Supplying and making end termination with brass compression gland, aluminium lugs for following size of PVC insulated & PVC sheathed / XLPE aluminium cable of 1.1kV grade as reqd.
392 x 10 sq.mm.
403.5 x 35 sq.mm.
41Supply & Laying of 32 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete.
42In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd.
43Laying charges In Pipe
44Laying charges On Surface
45Laying charges in open duct
46Supply of one number PVC insulated & PVC sheathed/XLPE aluminium conductor steel armoured power cable of following sizes 1.1kV grade as per IS 7098 (part 1) 1988. Make_Havells or equivalent approved make
472 x 10 sq.mm.
483.5 x 35 sq.mm.
49Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
501:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
51Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor level in all shapes and sizes in :
52Cement mortar 1:6 (1 cement : 6 coarse sand).
53Providing 12 mm cement plaster in fine sand of mix : 1:6 (1 cement: 6 fine sand) at all levels
54Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar.
55Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
5640 mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57612335
AUTHORITY Government Departments
TENDER VALUE 5.40 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Electrical Maintenance Work Of Swimming Pool.
Basic Detail
Tender No 59/EE/Elect/2026-27
Bidding Type Tender
Location
City Kanpur Nagar
State Uttar Pradesh
Key Dates
Publish Date 19 Sep 2026
Submission Date 29 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 5.40 Lakhs
Tender Fee Ref. Documents
EMD 10816
Exemption Not Available
Document List
8067ba59-d316-4f99-9ec9-b1203fc7f495.html
BOQ_974086.xls
Tendernotice_1 (10).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

8067ba59-d316-4f99-9ec9-b1203fc7f495.html

xls

BOQ_974086.xls

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders