Tender For special Repair/Replacement Of Heating And Cooling Appliances At Cantt Shillong And special Repair/Replacement Of Old Ci Pipe To Di Pipe Line At 119 Inf Bn (Ta) Assam Under Ge Shillong
Tender Value
49.27 Lakhs
Estimated cost
Bid Submission
10 Oct 2026
5 days left
EMD
98540
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
East Khasi Hills → Meghalaya
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair/Replacement Of Heating And Cooling Appliances At Cantt Shillong And special Repair/Replacement Of Old Ci Pipe To Di Pipe Line At 119 Inf Bn (Ta) Assam Under Ge Shillong
BOQ
| Sl. No. | Item Description |
| 1 | Supply, tasting installation and comminishing of split units indoor / outdoor complete with cordless remote control unit and with in built Heating and cooling arrangement and Digital Inverter twin rotary of capacity 1.5 TR, single phase 5 star rated complete all as specified and as directed. |
| 2 | Supply and fixing voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type, dsigned for input variation between having input voltage 130 V to 280 V, with output voltage stablized at 230 V with accuracy of (+/-) 25% with time delay and digital display with auth scroll input and output voltage complete and of capacity 5 KVA complete all as specified and as directed. |
| 3 | Supply, installation, commissioning of Metal/Hard Top Deep Freezer of capacity 300 ltr single phase 240 volt, 50 Hz complete all as specified and as directed. |
| 4 | Supply, installation, commissioning of Metal/Hard Top Deep Freezer of capacity 320 ltr single phase 240 volt, 50 Hz complete all as specified and as directed |
| 5 | Supply, installation, commissioning of Metal/Hard Top Deep Freezer of capacity 400 ltr single phase 240 volt, 50 Hz complete all as specified and as directed |
| 6 | Supply, installation, commissioning of elect driven single phase Refrigerator of capacity 185-195 ltr,min 3 star rating,digital inverter single door complete all as specified and as directed. |
| 7 | Supply, installation, commissioning of elect driven single phase Refrigerator of capacity 295-305 ltr, min 3 star rating,digital inverter, double door, complete all as specified and as directed |
| 8 | Supply, installation, commissioning of elect driven single phase Refrigerator of capacity 308-310 ltr complete all as specified and as directed |
| 9 | Supply, installation, commissioning of elect driven single phase Refrigerator of capacity 343 ltr, min 3 star rating, digital inverter, double door, complete all as specified and as directed |
| 10 | M&L for sub main wiring using two single core 4 Sqmm FRLS PVC insulated with unsheathed cable with copper conductor 1100 volts grade ISI marked drawing with casing capping and including accessorie like bends, tee etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and as directed. |
| 11 | S&F sheet metal enclosure SP 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed. |
| 12 | Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified and as directed. |
| 13 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed. |
| 14 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as directed. |
| 15 | Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed. |
| 16 | M&L cutting of existing road/hard standing// footpath surfaces for laying of GI/DI water tubing AND Making good to distrurbed surface with plain cement type B1 (1:2:4) using 20mm graded crushed stone aggregate as in coping/benching, slightly rounded or chamfered angles and throating, etc including necessary framework complete all as specified and as directed. |
| 17 | S&F Gun metal gate valve 50 mm bore, class-I(ISI) marked with iron wheel head, screwed both ends for iron pipe, suitable including taking down old existing unserviceable gate valve complete all as specified and as directed. |
| 18 | S&F Gun metal gate valve 40 mm bore, class-I(ISI) marked with iron wheel head, screwed both ends for iron pipe, suitable including taking down old existing unserviceable gate valve complete all as specified and as directed. |
| 19 | S&F Gun metal gate valve 25 mm bore, class-I(ISI) marked with iron wheel head, screwed both ends for iron pipe, suitable including taking down old existing unserviceable gate valve complete all as specified and as directed. |
| 20 | S&F Gun metal gate valve 20 mm bore, class-I(ISI) marked with iron wheel head, screwed both ends for iron pipe, suitable including taking down old existing unserviceable gate valve complete all as specified and as directed. |
| 21 | Supply, laying and connection in trenches 80 mm bore GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc including taking up or down old serviceable/unserviceable pipe with any connection including cleaning for re-fixing or removal from the side complete all as specified and as directed. (Note : excavation and earthwork shall be measured and paid separately). |
| 22 | Supply, laying and connection in trenches 50 mm bore GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc including taking up or down old serviceable/unserviceable pipe with any connection including cleaning for re-fixing or removal from the side complete all as specified and as directed. (Note : excavation and earthwork shall be measured and paid separately). |
| 23 | Supply, laying and connection in trenches 40 mm bore GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc including taking up or down old serviceable/unserviceable pipe with any connection including cleaning for re-fixing or removal from the side complete all as specified and as directed. (Note : excavation and earthwork shall be measured and paid separately). |
| 24 | Supply, laying and connection in trenches 25 mm bore GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc including taking up or down old serviceable/unserviceable pipe with any connection including cleaning for re-fixing or removal from the side complete all as specified and as directed. (Note : excavation and earthwork shall be measured and paid separately). |
| 25 | Supply, laying and connection in trenches 20 mm bore GI tubing, medium grade, including fittings such as tee, bend, nipple, socket, reducer, flange, union etc including taking up or down old serviceable/unserviceable pipe with any connection including cleaning for re-fixing or removal from the side complete all as specified and as directed. (Note : excavation and earthwork shall be measured and paid separately). |
| 26 | Supplying, laying, jointing, testing and commmisioning of 100 mm dia DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including rubber gasket joint (tyton joints) including taking down old unsv CI pipe, joints, bends, elbow, tees, rubber joints of 100 mm dia complete all as specified and directed. (Note : Joints shall be measured and paid separetely) |
| 27 | Supplying, laying, jointing, testing and commmisioning of 150 mm dia DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including rubber gasket joint (tyton joints) including taking down old unsv CI pipe, joints, bends, elbow, tees, rubber joints of 150 mm dia complete all as specified and directed. (Note : Joints shall be measured and paid separetely) |
| 28 | Material and Labour for DI fittings/specials of size upto 150 mm dia such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 1538-1993 complete all as specified and as directed. |
| 29 | Material and labour for Rubber Gasket Joint (Tyton Joint) of size 100 mm dia bore including jointing material for DI pipe complete all as specified and as directed |
| 30 | Material and labour for Rubber Gasket Joint (Tyton Joint) of size 150 mm dia bore including jointing material for DI pipe complete all as specified and as directed |
| 31 | Supplying and fixing, MS flanges of 100 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed. |
| 32 | M&L for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of size upto 150 mm dia complete all as specified and as directed. |
| 33 | M&L for Mechanical joints with rubber or fibre board gasket including nuts, bolts and double washers of size upto 150 mm dia complete all as specified and as directed. |
| 34 | Supply, fixing, jointing & testing Cast Iron Sluice Valve 100 mm dia ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and as directed. (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.) |
| 35 | Supply, fixing, jointing & testing Cast Iron Sluice Valve 150 mm dia ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and as directed. (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.) |
| 36 | Supply, fixing, jointing & testing Cast Iron Sluice Valve 80 mm dia ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and as directed. (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.) |
| 37 | M&L for construction of block masonry valve pit of size 0.9mtrx0.9mtrx0.9mtr complete with PCC1:3:6 type C1 solid block walling 20 cm thick set in cement mortar 1:4 over 100mm thick PCC 1:4:8 type D2 foundation 50 mm thick PCC 1:2:4 type B1 coping on the top of wall rendering 15 mm thick cement mortar 1:4 on inside and exposed external surface MS sheet cover angle iron frame and locking arrangement etc as mentioned in particular specification including dismantling old existing damaged valve pit complete all as specified and as directed. |
| 38 | M&L for construction of block masonry valve pit of size 0.6mtrx0.6mtrx0.9mtr complete with PCC1:3:6 type C1 solid block walling 20 cm thick set in cement mortar 1:4 over 100mm thick PCC 1:4:8 type D2 foundation 50 mm thick PCC 1:2:4 type B1 coping on the top of wall rendering 15 mm thick cement mortar 1:4 on inside and exposed external surface MS sheet cover angle iron frame and locking arrangement etc as mentioned in particular specification including dismantling old existing damaged valve pit complete all as specified and as directed. |
| 39 | Labour for cutting of CI /DI/GI pipe in position for reducing to required length for insertion of new tees, branches etc of upto 150 mm bore complete all as specified and as directed. |
| 40 | Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed. |
| 41 | Material and labour for Brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender