Project Description

Tender for Repair And Maintenance Of Chlorination Of Water & Repair To Chlorination Injecting Pump Sets, Ci/Di/Gi Distribution Line, Sluice Valve, Valve Pit Of Pumping And Supply Main Etc K Area Under Ge Chandigarh.

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF CHLORINATION OF WATER & REPAIR TO CHLORINATION INJECTING PUMP SETS, CI/DI/GI DISTRIBUTION LINE, SLUICE VALVE, VALVE PIT OF PUMPING AND SUPPLY MAIN ETC K AREA UNDER GE CHANDIGARH.
Sl. No. Item Description
1Taking up or down existing steel water tubing & connections including all fittings for 15 mm bore of pipe laying in trenches/ floor or in any position complete all as specified and directed.Note :- Excavation and earth work measured and paid separately.
2Taking up or down existing steel water tubing & connections including all fittings for 20 mm bore of pipe laying in trenches/ floor or in any position complete all as specified and directed.Note :- Excavation and earth work measured and paid separately.
3Taking up or down existing steel water tubing & connections including all fittings for 25 mm bore of pipe laying in trenches/ floor or in any position complete all as specified and directed.Note :- Excavation and earth work measured and paid separately.
4Taking up or down existing steel water tubing & connections including all fittings for 40 mm bore of pipe laying in trenches/ floor or in any position complete all as specified and directed.Note :- Excavation and earth work measured and paid separately.
5Taking up or down existing steel water tubing & connections including all fittings for 50 mm bore of pipe laying in trenches/ floor or in any position complete all as specified and directed.Note :- Excavation and earth work measured and paid separately.
6Taking up or down existing steel water tubing & connections including all fittings for 80 mm bore of pipe laying in trenches/ floor or in any position complete all as specified and directed.Note :- Excavation and earth work measured and paid separately.
7Taking up or down existing steel water tubing & connections including all fittings for 100 mm bore of pipe laying in trenches/ floor or in any position complete all as specified and directed.Note :- Excavation and earth work measured and paid separately.
8Taking up or down CI/ DI tubing 80 mm dia/ bore with fittings complete and all specified and directedNote: Excavation, Removal and returning/ fillling will be measured and paid separately under respective item.
9Taking up or down CI/ DI tubing 100 mm dia/ bore with fittings complete and all specified and directedNote: Excavation, Removal and returning/ fillling will be measured and paid separately under respective item.
10Taking up or down CI/ DI tubing 150 mm dia/ bore with fittings complete and all specified and directedNote: Excavation, Removal and returning/ fillling will be measured and paid separately under respective item.
11Taking up or down CI/ DI tubing 200 mm dia/ bore with fittings complete and all specified and directedNote: Excavation, Removal and returning/ fillling will be measured and paid separately under respective item.
12Disconnection and removing the unserviceable Air Release valve 80/ 100/ 150 mm dia of size with all fittings complete all as specified and directed.
13Disconnection and removing the unserviceable/ broken Spindle Steel 100 mm dia long with the check nuts & gate from the Sluice valve complete all as specified and directed.
14Disconnection and removing the unserviceable/ broken Spindle Steel 150 mm dia long with the check nuts & gate from the Sluice valve complete all as specified and directed.
15Demolition of Cement concrete unreinforced as in Ground Floor and paving n. exc. 15cm thick (above or below G.L.) complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
16Supply, laying, fixing, testing and commssioning of GI steel tubing medium grade 20 mm dia/ bore along with connecting all type accessories & fittings in trenches/ wall complete all as specified and directed
17Supply, laying, fixing, testing and commssioning of GI steel tubing medium grade 25 mm dia/ bore along with connecting all type accessories & fittings in trenches/ wall complete all as specified and directed
18Supply, laying, fixing, testing and commssioning of GI steel tubing medium grade 40 mm dia/ bore along with connecting all type accessories & fittings in trenches/ wall complete all as specified and directed
19Supply, laying, fixing, testing and commssioning of GI steel tubing medium grade 50 mm dia/ bore along with connecting all type accessories & fittings in trenches/ wall complete all as specified and directed
20Supply, laying, fixing, testing and commssioning of GI steel tubing medium grade 80 mm dia/ bore along with connecting all type accessories & fittings in trenches/ wall complete all as specified and directed
21Supply, laying, fixing, testing and commssioning of GI steel tubing medium grade 100 mm dia/ bore along with connecting all type accessories & fittings in trenches/ wall complete all as specified and directed
22Cleaning and maint of water supply installations including cutting/cleaning of grass/ bushes surrounding of installation in quartly two time complete all as directed by Enginer-in-Charge
23Relaying the serviceable GI Pipe line 15mm dia/ bore in the exsiting trenches/surface complete all as specified and as directed.Note:- Excavation earthwork shall be measured and paid sepratey under respective item.
24Relaying the serviceable GI Pipe line 20mm dia/ bore in the exsiting trenches/surface complete all as specified and as directed.Note:- Excavation earthwork shall be measured and paid sepratey under respective item.
25Relaying the serviceable GI Pipe line 25mm dia/ bore in the exsiting trenches/surface complete all as specified and as directed.Note:- Excavation earthwork shall be measured and paid sepratey under respective item.
26Relaying the serviceable GI Pipe line 40mm dia/ bore in the exsiting trenches/surface complete all as specified and as directed.Note:- Excavation earthwork shall be measured and paid sepratey under respective item.
27Relaying the serviceable GI Pipe line 50mm dia/ bore in the exsiting trenches/surface complete all as specified and as directed.Note:- Excavation earthwork shall be measured and paid sepratey under respective item.
28Relaying the serviceable GI Pipe line 80mm dia/ bore in the exsiting trenches/surface complete all as specified and as directed.Note:- Excavation earthwork shall be measured and paid sepratey under respective item.
29Relaying the serviceable GI Pipe line 100mm dia/ bore in the exsiting trenches/surface complete all as specified and as directed.Note:- Excavation earthwork shall be measured and paid sepratey under respective item.
30Cutting/screwing the existing steel tubing 15mm dia/ bore for inserting of Tee, Sluice valve/ gate valve, bends and elbow etc as specified and directed.Note :- Each cut will be measured and paid separately. Fitting will be measured and paid in separate items.
31Cutting/screwing the existing steel tubing 20 mm dia/ bore for inserting of Tee, Sluice valve/ gate valve, bends and elbow etc as specified and directed.Note :- Each cut will be measured and paid separately. Fitting will be measured and paid in separate items.
32Cutting/screwing the existing steel tubing 25mm dia/ bore for inserting of Tee, Sluice valve/ gate valve, bends and elbow etc as specified and directed.Note :- Each cut will be measured and paid separately. Fitting will be measured and paid in separate items.
33Cutting/screwing the existing steel tubing 40mm dia/ bore for inserting of Tee, Sluice valve/ gate valve, bends and elbow etc as specified and directed.Note :- Each cut will be measured and paid separately. Fitting will be measured and paid in separate items.
34Cutting/screwing the existing steel tubing 50mm dia/ bore for inserting of Tee, Sluice valve/ gate valve, bends and elbow etc as specified and directed.Note :- Each cut will be measured and paid separately. Fitting will be measured and paid in separate items.
35Cutting/screwing the existing steel tubing 80mm dia/ bore for inserting of Tee, Sluice valve/ gate valve, bends and elbow etc as specified and directed.Note :- Each cut will be measured and paid separately. Fitting will be measured and paid in separate items.
36Cutting/screwing the existing steel tubing 100mm dia/ bore for inserting of Tee, Sluice valve/ gate valve, bends and elbow etc as specified and directed.Note :- Each cut will be measured and paid separately. Fitting will be measured and paid in separate items.
37Supply, laying, fixing, testing, and commssioning of DI pipes 80mm dia with spigot/ flanged and socket ends centrifugally cast. Class K-9. (ISI Marked) in any length, laid in trenches complete all as specified and directed.
38Supply, laying, fixing, testing, and commssioning of DI pipes 100mm dia with spigot/ flanged and socket ends centrifugally cast. Class K-9. (ISI Marked) in any length, laid in trenches complete all as specified and directed.
39Supply, laying, fixing, testing, and commssioning of DI pipes 150mm dia with spigot/ flanged and socket ends centrifugally cast. Class K-9. (ISI Marked) in any length, laid in trenches complete all as specified and directed.
40Supply, laying, fixing, testing, and commssioning of DI pipes 200mm dia with spigot/ flanged and socket ends centrifugally cast. Class K-9. (ISI Marked) in any length, laid in trenches complete all as specified and directed.
41Re-laying, testing, commissioning of CI/DI pipe line 80 mm dia, pipe line in the exsiting trenches/ wall both socket and flanged ends complete all as specified and directed.
42Re-laying, testing, commissioning of CI/DI pipe line 100 mm dia, pipe line in the exsiting trenches/ wall both socket and flanged ends complete all as specified and directed.
43Re-laying, testing, commissioning of CI/DI pipe line 150 mm dia, pipe line in the exsiting trenches/ wall both socket and flanged ends complete all as specified and directed.
44Re-laying, testing, commissioning of CI/DI pipe line 200 mm dia, pipe line in the exsiting trenches/ wall both socket and flanged ends complete all as specified and directed.
45Cast iron Pipes 80mm dia with Spigot and Socket ends centrifugally cast, Class LA laid in trenches complete all as specified as directed.Note :- (i) Excavation, earthwork shall be measured and paid seperately.(ii) CI fitting will be measured and paid seperately.
46Cast iron Pipes 100mm dia with Spigot and Socket ends centrifugally cast, Class LA laid in trenches complete all as specified as directed.Note :- (i) Excavation, earthwork shall be measured and paid seperately.(ii) CI fitting will be measured and paid seperately.
47Cast iron Pipes 150mm dia with Spigot and Socket ends centrifugally cast, Class LA laid in trenches complete all as specified as directed.Note :- (i) Excavation, earthwork shall be measured and paid seperately.(ii) CI fitting will be measured and paid seperately.
48Cast iron Pipes 200mm dia with Spigot and Socket ends centrifugally cast, Class LA laid in trenches complete all as specified as directed.Note :- (i) Excavation, earthwork shall be measured and paid seperately.(ii) CI fitting will be measured and paid seperately.
49Cutting the existing road of 0.30m width and 0.60m depth for laying DI/GI GI pipe with all fittings such as bends, sockets, reducers union etc, complete incl excavation in any type of soil, returning/ filling, removal and PCC 1:2:4 15 cm below the GL for making the the road cut portion good complete all as specified.
50Cutting CI/DI 80mm dia pipes and reducing or fixing of connecting accessories to required length before laying complete all as specified and directed.Note: Each cut will be measured and paid separately under respective item.
51Cutting CI/DI 100mm dia pipes and reducing or fixing of connecting accessories to required length before laying complete all as specified and directed.Note: Each cut will be measured and paid separately under respective item.
52Cutting CI/DI 150mm dia pipes and reducing or fixing of connecting accessories to required length before laying complete all as specified and directed.Note: Each cut will be measured and paid separately under respective item.
53Cleaning of overhead water storage tank of capacity 1,00,000 gallons (450000Ltr Cap) by scraping internal and external surface of tank with brush and removing all scale / dirt / deposited silt including washed to internal surface of tank with solution of bleaching powder and applying Two coat of cement base paint to internal and external surfaces of wall, top and bottom of tank, pillars/ beams/ pipes etc after preperation of surface of OHT and providing one coat of synthetic enamelled paint with colour code on inlet/ outlet/ washout/ over flow pipes surfaces as per existing with writting the cleaning date with white colour on black base all as specified and as directed.Note : (a) Removing/ Cleaning of Honey Bee hives shall be the responsibility of the contractor. No delay, No additional charges shall be considered on this account rates quoted against the item shall include the said element.(b) Contractor is responsible for making all safety arrangments, scaffolding/ jhulla for carrying out the above job with due care at a height of approx 22 MtrNote (i) The cost of required T&P, machine, motor, scaffolding shuttering shall be arranged by the contractor at own cost.
54Cleaning of overhead water storage tank of capacity 75,000 gallons (337500Ltr Cap) by scraping internal and external surface of tank with brush and removing all scale / dirt / deposited silt including washed to internal surface of tank with solution of bleaching powder and applying Two coat of cement base paint to internal and external surfaces of wall, top and bottom of tank, pillars/ beams/ pipes etc after preperation of surface of OHT and providing one coat of synthetic enamelled paint with colour code on inlet/ outlet/ washout/ over flow pipes surfaces as per existing with writting the cleaning date with white colour on black base all as specified and as directed.Note : (a) Removing/ Cleaning of Honey Bee hives shall be the responsibility of the contractor. No delay, No additional charges shall be considered on this account rates quoted against the item shall include the said element.(b) Contractor is responsible for making all safety arrangments, scaffolding/ jhulla for carrying out the above job with due care at a height of approx 22 MtrNote :- (i) The cost of required T&P, machine, motor, scaffolding shuttering shall be arranged by the contractor at own cost.
55Cleaning of overhead water storage tank of capacity 50,000 gallons (225000Ltr Cap) by scraping internal and external surface of tank with brush and removing all scale/ dirt/ deposited silt including washed to internal surface of tank with solution of bleaching powder and applying Two coat of cement base paint to internal and external surfaces of wall, top and bottom of tank, pillars/ beams/ pipes etc after preperation of surface of OHT and providing one coat of synthetic enamelled paint with colour code on inlet/ outlet/ washout/ over flow pipes surfaces as per existing with writting the cleaning date with white colour on black base all as specified and as directed.Note : (a) Removing/ Cleaning of Honey Bee hives shall be the responsibility of the contractor. No delay, No additional charges shall be considered on this account rates quoted against the item shall include the said element.(b) Contractor is responsible for making all safety arrangments, scaffolding/ jhulla for carrying out the above job with due care at a height of approx 22 MtrNote :- (i) The cost of required T&P, machine, motor, scaffolding shuttering shall be arranged by the contractor at own cost.
56Cleaning of semi under ground water storage tank of 15000 gallons by scraping internal and external surface of tank with brush and removing all scale / dirt / deposited silt including washed to internal surface of tank with solution of bleaching powder and applying Two coat of cement base paint to internal and external surfaces of wall, top and bottom of tank, pillars/ beams/ pipes etc after preperation of surface of OHT and providing one coat of synthetic enamelled paint with colour code on inlet/ outlet/ washout/ over flow pipes surfaces as per existing with writting the cleaning date with white colour on black base all as specified and as directed.Note : (a) Removing/ Cleaning of Honey Bee hives shall be the responsibility of the contractor. No delay, No additional charges shall be considered on this account rates quoted against the item shall include the said element.(b) Contractor is responsible for making all safety arrangments, scaffolding/ jhulla for carrying out the above job with due care at a height of approx 22 MtrNote :- (i) The cost of required T&P, machine, motor, scaffolding shuttering shall be arranged by the contractor at own cost.
57Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5M in depth for taking out/for laying under ground pipes etc and getting out in Soft/loose soil complete all as specified and as directed.
58Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cms in soft/ loose soil complete all as specified and as directed.
59Removing excavated soil to a distance n-exc 50mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and as directed.
60Plain cement concrete 1:2:4 type B-1using 20mm graded stone aggregate as in coping including framed work weathering, slightly rounded or chamfered angle and throating as directed including necessary form work complete all as specifed and directed.
61Disconnection and removing of gate valve 20 mm bore ISI marked and Supply and fixing Gun metal gate or globe valves heavy duty quarter turn type, full way openig with iron wheel head screwed with both end of GI tubing 20 mm bore ISI marked complete all as specified and directed.
62Disconnection and removing of gate valve 25 mm bore ISI marked and Supply and fixing Gun metal gate or globe valves heavy duty quarter turn type, full way openig with iron wheel head screwed with both end of GI tubing 25 mm bore ISI marked complete all as specified and directed.
63Disconnection and removing of gate valve 40 mm bore ISI marked and Supply and fixing Gun metal gate or globe valves heavy duty quarter turn type, full way openig with iron wheel head screwed with both end of GI tubing 40 mm bore ISI marked complete all as specified and directed.
64Disconnection and removing of gate valve 50 mm bore ISI marked and Supply and fixing Gun metal gate or globe valves heavy duty quarter turn type, full way openig with iron wheel head screwed with both end of GI tubing 50 mm bore ISI marked complete all as specified and directed.
65Disconnecting and removing the unserviceable/ broken Spindle Steel with the check nuts & gate from sluice valve of 100 mm dia and Material and labour for new stainless steel with brass check nuts including polishing, machining, threading and neccesary lathe work complete all as specified and directed.
66Disconnecting and removing the unserviceable/ broken Spindle Steel with the check nuts & gate from sluice valve of 150 mm dia and Material and labour for new stainless steel with brass check nuts including polishing, machining, threading and neccesary lathe work complete all as specified and directed.
67Disconnection and removing cast iron Non return valve 150 mm bore and Supply and fixing cast iron Non return valve 150 mm bore (ISI marked) with brass flap and seat without by pass arrangement, flanged both ends, including jointing materials such as nuts, bolts, washers and rubber gasket etc.all as specified and directed.
68Disconnection and removing cast iron Non return valve 100 mm bore and Supply and fixing cast iron Non return valve 100 mm bore (ISI marked) with brass flap and seat without by pass arrangement, flanged both ends, including jointing materials such as nuts, bolts, washers and rubber gasket etc.all as specified and directed.
69Disconnection and removing cast iron Non return valve 80 mm bore and Supply and fixing cast iron Non return valve 80 mm bore (ISI marked) with brass flap and seat without by pass arrangement, flanged both ends, including jointing materials such as nuts, bolts, washers and rubber gasket etc.all as specified and directed.
70Supply and fixing Air Release valve double chamber, IS-14845 of size 100 mm dia of size with all fittings complete all as specified and directed.
71Supply and fixing Air Release valve double chamber, IS-14845 of size 150 mm dia of size with all fittings complete all as specified and directed.
72Disconnection and removing cast iron sluice valve 80mm nominal bore pipe/ fitting and Supply and fixing cast iron sluice valve class PN1.6, ISI Marked, confirming to 14846 (2000) with flanged and drilled ends suitable for 80mm nominal bore pipe/ fitting with iron wheel high tensile steel spindie with & including rubbered gasket, nuts, bolts and wahsers complete all as specified and directed.
73Disconnection and removing cast iron sluice valve 100 mm nominal bore pipe/ fitting and Supply and fixing cast iron sluice valve class PN1.6, ISI Marked, confirming to 14846 (2000) with flanged and drilled ends suitable for 100mm nominal bore pipe/ fitting with iron wheel high tensile steel spindie with & including rubbered gasket, nuts, bolts and wahsers complete all as specified and directed.
74Disconnection and removing cast iron sluice valve 150 mm nominal bore pipe/ fitting and Supply and fixing cast iron sluice valve class PN1.6, ISI Marked, confirming to 14846 (2000) with flanged and drilled ends suitable for 150mm nominal bore pipe/ fitting with iron wheel high tensile steel spindie with & including rubbered gasket, nuts, bolts and wahsers complete all as specified and directed.
75Disconnection and removing cast iron sluice valve 200 mm nominal bore pipe/ fitting and Supply and fixing cast iron sluice valve class PN1.6, ISI Marked, confirming to 14846 (2000) with flanged and drilled ends suitable for 200mm nominal bore pipe/ fitting with iron wheel high tensile steel spindie with & including rubbered gasket, nuts, bolts and wahsers complete all as specified and directed.
76Bends any materials (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 200mm bore complete all as spfd and as directed.
77Supply and fixing 80 mm column pipe mild steel water pipe Heavy duty both end flangd as column pipe (each length of column pipe 3metre) long as IN REPAIR complete all as directed by Engineer-in-charge.
78Supply and fixing 100 mm column pipe mild steel water pipe Heavy duty both end flangd as column pipe (each length of column pipe 3metre) long as IN REPAIR complete all as directed by Engineer-in-charge.
79Supply and fixing 150 mm column pipe mild steel water pipe Heavy duty both end flangd as column pipe (each length of column pipe 3metre) long as IN REPAIR complete all as directed by Engineer-in-charge.
80Replacement of rubber gasket for column pipe (80/100/125 bore) complete all as specified and as directed by Engineer-in-Charge.
81Nut, Bolt & Washers machine made suitable for jointing of column pipe fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
82Construction of brick masonary valve pits as in repairs of internal size 120cm x120cm x120cm (depath of chamber to be recokoned from the top of PCC in foundation to top of MS cover) of chamber with and including MS sheet over fabricated from 11 gauge MS sheet and frame of angle from 40mm x 40mm x 5mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil , returining, filling in approved soil, disposal of surplus soiol to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation brick work in cement mortar 1:6, 15mm plastering in cement mortar 1:4 both internally and externally 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified.
83Construction of brick masonary valve pits as in repairs of internal size 90cm x90cm x90cm (depath of chamber to be recokoned from the top of PCC in foundation to top of MS cover) of chamber with and including MS sheet over fabricated from 11 gauge MS sheet and frame of angle from 40mm x 40mm x 5mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil , returining, filling in approved soil, disposal of surplus soiol to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation brick work in cement mortar 1:6, 15mm plastering in cement mortar 1:4 both internally and externally 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified.
84Supply and replacement of glen dori as per site required for sluice valve fittings for any size complete all as specified..
85Earthing complete with galvanized steel earth plate electrode 600x600x6mm surrounded by mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less 2.25mtr below ground level with top edge of earth plate at a depth of not less than 1.50mtrs below ground level connected with and including 32x6mm galvanized iron strip as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanized iron, 20mm dia medium grade GI pipes for watering with funnel, wire mesh and 40mm GI light grade protection pipe for GI strip and including necessary excavation, earth work, PCC 1:3:6 type C-2 concrete pit and RCC pit cover charcoal and common salt filling in alternate layers complete all as specified and directed by Engineer-in-Charge on electrical plate no-3 of SSR Par-I of 2009.Note:(i) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (ii) The result sheet of earthing may submit to sub division level by contractor.(iii) The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level.
86Test point terminal block made out of gun metal or phosphorus bronzed size 75 x 75 x 25mm, drilled and screwed including 03 nos 8mm dia 25mm long hexagonal head screw all as specified and directed.
87Supply and fix as in repair including testing and commissioning of chlorine tablets contained (REFILL) in plastic cylindrival sealed disposable sanitiserefil for disinfection of drinking water with arrangement for controlled release of disinfectant in water suitable for operation through recommended dosing system all as specified and directed bu Engineer-in-ChargeMake: Decibac technologies pvt Ltd (item NR-SP11AE, Stequa 411AE refill for upgraded version model of ADS_PRO. Please Enable Macros to View BoQ information
88Supply and fix as in repair including testing and commissioning of chlorine tablets contained (REFILL) in plastic cylindrival sealed disposable sanitiserefil for disinfection of drinking water with arrangement for controlled release of disinfectant in water suitable for operation through recommended dosing system all as specified and directed bu Engineer-in-ChargeMake: Decibac technologies pvt Ltd (item NR-SP11AE, Stequa 411AE refill for upgraded version model of ADS_PRO. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57612198
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 10-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Chlorination Of Water & Repair To Chlorination Injecting Pump Sets, Ci/Di/Gi Distribution Line, Sluice Valve, Valve Pit Of Pumping And Supply Main Etc K Area Under Ge Chandigarh.
Basic Detail
Tender No GE/CHD/T-61/2026-27
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 19 Sep 2026
Submission Date 10 Oct 2026
Open Date 12 Oct 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
b3d94260-3275-4f5a-b3be-1b94d5b8c6e4.html
BOQ_885860.xls
tendercomplete.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

b3d94260-3275-4f5a-b3be-1b94d5b8c6e4.html

xls

BOQ_885860.xls

pdf

tendercomplete.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders