Project Description

Tender for Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At Zone A Under Ge (Navy) Chennai.

BOQ

Name of Work:- REPAIR /MAINTENANCE OF ACs, COOLING APPLIANCES AND VOLTAGE STABILIZERS AT ZONE A UNDER GE (NAVY) CHENNAI.
Sl. No. Item Description
1Checking and testing of window and split AC of any capacity including Leak arresting, cleaning etc all as directed by Engr in Charge .
2Material and labour for Spray painting to the whole unit of window type air conditioner 1.5/2.0 Ton by two coats of synthetic enamel paint after cleaning the unit assembly with castic soda wash complete all as specified and directed.
3Dismantling the unserviceable uncut rotary compressor from the split type AC unit and replacement with new rotary compressor 1.5 Ton capacity including servicing the entire unit complete all as specified and directed.
4All as per Sl item No 3 herein before but suitable for split type AC unit OF 2.0 Ton capacity.Note for item 2 : Gas shall be measured and paid separately.
5Replacement of Unserviceable remote control suitable for 1.5/2.00 ton capacity Split type AC of any make complete all as specified and directed.
6All as per Sl item No 5 herein before but Electronic PCB board any type.
7All as per Sl item No 5 herein before but fan motor of 1.5/2 ton capacity AC.
8All as per Sl item No 5 herein before but Condenser coil and including servicing the entire unit.
9All as per Sl item No 5 herein before but suction valve,
10All as per Sl item No 5 herein before but discharge valve
11All as per Sl item No 5 herein before but Indoor unit blower motor of 1.5/2.0 ton capactiy
12All as per Sl item No 5 herein before but PVC drain pipe flexible type of suitable size
13All as per Sl itemNo 5 herein before but fan blade set
14Replacement of new indoor unit for split type AC 1.5 ton capactiy and including servicing the entire unit of any make complete all as specified and directed as per the existing make and model.
15Material and labour for Spray painting to the whole out door unit of split type air conditioner 1.5/2.0 Ton with two coats of synthetic enamel paint after cleaning the unit assembly with castic soda wash complete and including servicing the entire unit all as specified and directed.
16Shifting of split type Air conditioner any capacity including supply & fixing of factory fabricated metal support suitable to mount out door unit (one pair per AC) and duly making holes into wall for insertion of copper pipe,drain pipe and 3 core cable,and making good the distrubed surfaces complete and including servicing the entire unit all as specified and directed.
17Dismantling the unserviceable uncut hermitically sealed compressor from the water cooler unit and replacing with factory re-conditioned hermitically sealed compressor for water cooler of any make, 40/ 80 liters capacity and including servicing the entire unit complete all as specified and directed. Note :Gas shall be measured and paid separately .
18Supply and fix Starting relay for 40 to 150 liters water cooler including dismantiling the old unserviceable one and servicing the entire unit complete all as specified and directed.
19All as per Sl item No 18 herein before but over load protection.
20All as per Sl item No 18 herein before but thermostat.
21All as per Sl item No 18 herein before but Fan blade assembly suitable.
22All as per Sl item No 18 herein before but push cock brass chromium plated of size 15mm.
23All as per Sl item No 18 herein before but branded new fan motor with base for suitable capacity
24All as per Sl item No 18 herein before but top lid gasket for 80/120 Ltr capacity
25All as per Sl item No 18 herein before but drain stainless steel tray with drain elbow and connector
26All as per Sl item No 18 herein before but Gate valve brass screwed both ends of size 15mm bore
27All as per Sl item No 18 herein before but Float valves brass with PVC ball complete suitable for 15mm bore, ISI marked
28All as per Sl item No 18 herein before but PVC hose connection pipe with both ends having brass coupling threaded for 15mm GI tubing of standard length
29Material and labour for spray painting of water cooler with two coats of pastel blue paint to the external surfaces of water cooler and Two coats of anticorrosive black paint over a coat of red oxide primer upto 15 cm height from the base allround including legs for inside of water cooler, of any capacity and including servicing the entire unit all as specified and directed.
30Dismantling the unserviceable uncut hermitically sealed compressor from the Refrigerator unit and replacing with factory re-conditioned hermitically sealed compressor for refrigerator any make 210 liters to 310 ltr capacity and including servicing the entire unit all as specified and directed.
31All as per Sl item No 30 herein before but for 165 to 200 liters refrigerator.
32Supply and fix of relay for 165 to 310 liters Refrigerator including dismantling the old unserviceable one complete all as specified and directed.
33All as per Sl item No 32 herein before but over load protector 1/6 HP
34All as per Sl item No 32 herein before but bulb pin/screw type 10/15 W capacity.
35All as per Sl item No 32 herein before but thermostat defrosting type.
36All as per Sl item No 32 herein before but cooling coil.
37All as per Sl item No 32 herein before but condenser coil.
38All as per Sl item No 32 herein before but freezer door.
39Material and labour for two coats of duco paint on exterior face of the refrigerator of any capacity by spray painting including removing the dent etc., complete all as specified and directed.
40Dismantling the unserviceable uncut hermitically sealed compressor from the deep freezer unit and replaced with factory re-conditioned hermitically sealed compressor for deep freezer any make up to 425 ltr capacity complete all as specified and directed. Note :Gas shall be measured and paid separately .
41Supply and fix of relay box type deep freezer including dismantling the old unserviceable items complete all as specified and directed.
42All as per Sl item No 41 herein before but overload protector 1/6HP.
43All as per Sl item No 41 herein before but door magnetic gasket.
44All as per Sl item No 41 herein before but condenser coil.
45All as per Sl item No 41 herein before but brand new fan motor with base 1/10HP
46Material and labour for two coats of duco paint on exterior face of the deep freezer of any capacity by spray painting including removing the dent etc complete all as specified and directed.
47Taking out the voltage stablizer of any make and of capacity 4/5 KVA from site and transporting to servicing centre to detect /identify the nature of defects/repairs and reassembling after repair/servicing and commissioning at site including testing the same to the entire satisfaction of Engineer-in-Charge complete all as specified and directed.
48All as per Sl item No 47 herein before but capactity upto 3 KVA.
49Dismantling the burnt out transformer from the 5 KVA capacity stablizer of any make and rewinding the same with supper enameled copper wire includinguding provision of all materials and refixing into the stablizer and testing to the entire satisfaction of Engineer-in-Charge and testing complete all as specified and directed.
50All as per Sl item No 49 herein before but capactity 4 KVA.
51Supply and fixing relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed.
52All as per Sl item No 51 here-in- before but PCB (printed circuit board).
53Supply and fix copper pipe 1/2\\" dia for all summer appliances of any capacity including dismantling the unserviceable pipe complete all as specified and directed.
54All as per Sl item No 53 herein before but size 1/4\\" dia
55Supply and fix two pin sheet metal earth plug top and metal clad socket 20 Amps capacity complete all as specified and directed.
56Supply only Refrigerant Gas R-22 all as specifed and directed.
57Supply only Refrigerant Gas R-410A/ R32 all as specified and directed.
58Supply only capacitor 40/50 mfd all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57612197
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At Zone A Under Ge (Navy) Chennai.
Basic Detail
Tender No 8837/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 19 Sep 2026
Submission Date 30 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value 9 Lakhs
Tender Fee 500
EMD 18000
Exemption Available
Document List
5bafa94c-b189-454a-b246-c8f2e7d5ab64.html
8837GENERALPAGES.pdf
8837PS.pdf
BOQ_885897.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

5bafa94c-b189-454a-b246-c8f2e7d5ab64.html

pdf

8837GENERALPAGES.pdf

pdf

8837PS.pdf

xls

BOQ_885897.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders