Tender For Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At Zone A Under Ge (Navy) Chennai.
Tender Value
9 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
3 days left
EMD
18000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At Zone A Under Ge (Navy) Chennai.
BOQ
| Sl. No. | Item Description |
| 1 | Checking and testing of window and split AC of any capacity including Leak arresting, cleaning etc all as directed by Engr in Charge . |
| 2 | Material and labour for Spray painting to the whole unit of window type air conditioner 1.5/2.0 Ton by two coats of synthetic enamel paint after cleaning the unit assembly with castic soda wash complete all as specified and directed. |
| 3 | Dismantling the unserviceable uncut rotary compressor from the split type AC unit and replacement with new rotary compressor 1.5 Ton capacity including servicing the entire unit complete all as specified and directed. |
| 4 | All as per Sl item No 3 herein before but suitable for split type AC unit OF 2.0 Ton capacity.Note for item 2 : Gas shall be measured and paid separately. |
| 5 | Replacement of Unserviceable remote control suitable for 1.5/2.00 ton capacity Split type AC of any make complete all as specified and directed. |
| 6 | All as per Sl item No 5 herein before but Electronic PCB board any type. |
| 7 | All as per Sl item No 5 herein before but fan motor of 1.5/2 ton capacity AC. |
| 8 | All as per Sl item No 5 herein before but Condenser coil and including servicing the entire unit. |
| 9 | All as per Sl item No 5 herein before but suction valve, |
| 10 | All as per Sl item No 5 herein before but discharge valve |
| 11 | All as per Sl item No 5 herein before but Indoor unit blower motor of 1.5/2.0 ton capactiy |
| 12 | All as per Sl item No 5 herein before but PVC drain pipe flexible type of suitable size |
| 13 | All as per Sl itemNo 5 herein before but fan blade set |
| 14 | Replacement of new indoor unit for split type AC 1.5 ton capactiy and including servicing the entire unit of any make complete all as specified and directed as per the existing make and model. |
| 15 | Material and labour for Spray painting to the whole out door unit of split type air conditioner 1.5/2.0 Ton with two coats of synthetic enamel paint after cleaning the unit assembly with castic soda wash complete and including servicing the entire unit all as specified and directed. |
| 16 | Shifting of split type Air conditioner any capacity including supply & fixing of factory fabricated metal support suitable to mount out door unit (one pair per AC) and duly making holes into wall for insertion of copper pipe,drain pipe and 3 core cable,and making good the distrubed surfaces complete and including servicing the entire unit all as specified and directed. |
| 17 | Dismantling the unserviceable uncut hermitically sealed compressor from the water cooler unit and replacing with factory re-conditioned hermitically sealed compressor for water cooler of any make, 40/ 80 liters capacity and including servicing the entire unit complete all as specified and directed. Note :Gas shall be measured and paid separately . |
| 18 | Supply and fix Starting relay for 40 to 150 liters water cooler including dismantiling the old unserviceable one and servicing the entire unit complete all as specified and directed. |
| 19 | All as per Sl item No 18 herein before but over load protection. |
| 20 | All as per Sl item No 18 herein before but thermostat. |
| 21 | All as per Sl item No 18 herein before but Fan blade assembly suitable. |
| 22 | All as per Sl item No 18 herein before but push cock brass chromium plated of size 15mm. |
| 23 | All as per Sl item No 18 herein before but branded new fan motor with base for suitable capacity |
| 24 | All as per Sl item No 18 herein before but top lid gasket for 80/120 Ltr capacity |
| 25 | All as per Sl item No 18 herein before but drain stainless steel tray with drain elbow and connector |
| 26 | All as per Sl item No 18 herein before but Gate valve brass screwed both ends of size 15mm bore |
| 27 | All as per Sl item No 18 herein before but Float valves brass with PVC ball complete suitable for 15mm bore, ISI marked |
| 28 | All as per Sl item No 18 herein before but PVC hose connection pipe with both ends having brass coupling threaded for 15mm GI tubing of standard length |
| 29 | Material and labour for spray painting of water cooler with two coats of pastel blue paint to the external surfaces of water cooler and Two coats of anticorrosive black paint over a coat of red oxide primer upto 15 cm height from the base allround including legs for inside of water cooler, of any capacity and including servicing the entire unit all as specified and directed. |
| 30 | Dismantling the unserviceable uncut hermitically sealed compressor from the Refrigerator unit and replacing with factory re-conditioned hermitically sealed compressor for refrigerator any make 210 liters to 310 ltr capacity and including servicing the entire unit all as specified and directed. |
| 31 | All as per Sl item No 30 herein before but for 165 to 200 liters refrigerator. |
| 32 | Supply and fix of relay for 165 to 310 liters Refrigerator including dismantling the old unserviceable one complete all as specified and directed. |
| 33 | All as per Sl item No 32 herein before but over load protector 1/6 HP |
| 34 | All as per Sl item No 32 herein before but bulb pin/screw type 10/15 W capacity. |
| 35 | All as per Sl item No 32 herein before but thermostat defrosting type. |
| 36 | All as per Sl item No 32 herein before but cooling coil. |
| 37 | All as per Sl item No 32 herein before but condenser coil. |
| 38 | All as per Sl item No 32 herein before but freezer door. |
| 39 | Material and labour for two coats of duco paint on exterior face of the refrigerator of any capacity by spray painting including removing the dent etc., complete all as specified and directed. |
| 40 | Dismantling the unserviceable uncut hermitically sealed compressor from the deep freezer unit and replaced with factory re-conditioned hermitically sealed compressor for deep freezer any make up to 425 ltr capacity complete all as specified and directed. Note :Gas shall be measured and paid separately . |
| 41 | Supply and fix of relay box type deep freezer including dismantling the old unserviceable items complete all as specified and directed. |
| 42 | All as per Sl item No 41 herein before but overload protector 1/6HP. |
| 43 | All as per Sl item No 41 herein before but door magnetic gasket. |
| 44 | All as per Sl item No 41 herein before but condenser coil. |
| 45 | All as per Sl item No 41 herein before but brand new fan motor with base 1/10HP |
| 46 | Material and labour for two coats of duco paint on exterior face of the deep freezer of any capacity by spray painting including removing the dent etc complete all as specified and directed. |
| 47 | Taking out the voltage stablizer of any make and of capacity 4/5 KVA from site and transporting to servicing centre to detect /identify the nature of defects/repairs and reassembling after repair/servicing and commissioning at site including testing the same to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. |
| 48 | All as per Sl item No 47 herein before but capactity upto 3 KVA. |
| 49 | Dismantling the burnt out transformer from the 5 KVA capacity stablizer of any make and rewinding the same with supper enameled copper wire includinguding provision of all materials and refixing into the stablizer and testing to the entire satisfaction of Engineer-in-Charge and testing complete all as specified and directed. |
| 50 | All as per Sl item No 49 herein before but capactity 4 KVA. |
| 51 | Supply and fixing relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed. |
| 52 | All as per Sl item No 51 here-in- before but PCB (printed circuit board). |
| 53 | Supply and fix copper pipe 1/2\\" dia for all summer appliances of any capacity including dismantling the unserviceable pipe complete all as specified and directed. |
| 54 | All as per Sl item No 53 herein before but size 1/4\\" dia |
| 55 | Supply and fix two pin sheet metal earth plug top and metal clad socket 20 Amps capacity complete all as specified and directed. |
| 56 | Supply only Refrigerant Gas R-22 all as specifed and directed. |
| 57 | Supply only Refrigerant Gas R-410A/ R32 all as specified and directed. |
| 58 | Supply only capacitor 40/50 mfd all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer